Keysight 6800B Series
AC Power Source/Analyzers, 375-1750 VA, GPIB
An integrated AC power solution
Data Sheet
Provides a complete AC and DC power and measurement solution
Protect valuable DUTs with extensive protection features
Easy to use graphical user interface (GUI)
The Complete AC Power Test Solution
Keysight Technologies, Inc., AC power source/analyzers provide a complete AC test solution. As AC sourc-
es, they combine the capabilities of a power amplier and an arbitrary waveform generator. This allows you
to simulate normal waveforms and many types of distorted power waveforms. The built in power analyzer
combines the capabilities of a multimeter, oscilloscope, harmonic analyzer and power analyzer. These instru-
ments may also be used to produce DC power, either alone or as a DC offset to an AC waveform.
Since your product will have to operate in the real world of unpredictable AC power, you need to design and
verify its correct operation under a wide range of AC power inputs. Brownouts, dropouts, sags, and other
irregularities are not unusual in many communities today. Keysight AC power source/analyzers have the
features needed to easily accomplish this test goal either in an R&D environment or on the manufacturing
test oor. If you plan to sell your products in a worldwide market, you will also need to test them at the line
voltages and frequencies for which they will eventually operate. There is also additional testing needed to
meet regulatory requirements for sale into some countries.
Keysight AC power source/analyzers offer a complete solution for AC power testing, helping you to simplify
this important task. These instruments combine the features of a power amplier and arbitrary waveform
generator to give you the ability to do all of the tests that you need. There are many standard prepro-
grammed waveforms, or you can use the transient generation system to simulate sophisticated and repeat-
able AC line disturbances. DC power can also be generated, either as a DC offset or as a pure DC signal.
03 | Keysight | 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB - Data Sheet
Powerful Built-in Measurement Capabilities
Keysight AC power source/analyzers have extensive 16-bit precision measurement
capabilities which would normally require a number of complex measurement in-
struments, including a DMM (digital multimeter), oscillo-scope, power analyzer, and
harmonic analyzer. The precision measurements include:
rms, DC, AC + DC voltage and current
Peak voltage and current
Real, apparent, and reactive power
Harmonic analysis of voltage and current waveforms providing amplitude and phase
up to the 50th harmonic
THD (total harmonic distortion)
Triggered acquisition of digitized voltage and current
Using the measurement capabilities of a Keysight AC power source/analyzer simplies
your test setups and helps you obtain accurate data quickly.
Dual power analyzer Option 020
The powerful built-in power meter/ analyzer in Keysight AC power source/analyzers pro-
vides everything that you need to make AC measurements at the AC input to your DUT.
For many test scenarios, this is the extent of the AC analysis required.
Some test scenarios, however, require AC measurements to be made at both the AC
input and the AC output of the DUT. Option 020 provides an additional power analyzer,
complete with a precision current shunt, which can be connected anywhere you need it.
This second analyzer can even be used for tests where the AC power source/analyzer is
not providing power, thus expanding the usefulness of this instrument to many more test
congurations. The additional analyzer is equivalent in specications and capabilities to
the standard analyzer.
Using the dual power analyzer option instead of an additional power analyzer instrument
externally is more than just convenient. Measurements on all four measurement channels
(AC source output voltage and current, and dual power analyzer voltage and current in-
puts) are inherently synchronized with the AC power source/analyzers output waveform.
This precision would be difcult to achieve using separate measurement instruments.
Examples dual power analyzer applications
Complete testing of uninterruptible power sources (UPS)
Efciency testing of DC power supplies
Efciency testing of AC power sources
Efciency testing of transformers
Safety testing of transformers
Line disturbance and brownout
testing of DC power supplies
Line disturbance and brownout
testing of AC power sources
Sleep mode current monitoring
Independent power analyzer
04 | Keysight | 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB - Data Sheet
Sleep mode current monitoring
Many electronic products have power-saving or sleep modes. In this mode, the device
draws only enough power to be able to recognize a “wake-up” signal, and then execute
a smooth “wake-up”. The power drawn in this mode is a critical parameter, and the
ability to accurately monitor it is important. The accessory precision current shunt that
is supplied with option 020 is mounted in such a way to make it easy for you to replace
it with a precision resistor of your choice. By doing this, you can congure the system to
accurately monitor extremely low currents. This provides an easy way for you to prole
the current draw in all modes of your product’s operation. Since Keysight 6811B-6813B
AC power source/analyzers produce DC power as well as AC power, portable battery
operated products can also be tested with this conguration.
UPS (uninterruptible power source) testing
The dual power analyzer option provides many important benets for UPS testing. Since
the key to correct UPS operation is having the output react properly to changes on the
input, being able to monitor the output relative to the input simplies testing. For exam-
ple, commands are available to enable calculation of UPS transfer time, and the phase
difference between the UPS input and output voltage. Keysight AC power source/ana-
lyzers also have programmable output impedance, enabling the UPS designer to verify
product stability over a wide range of AC line impedance.
Graphical user interface (GUI)
When you need to run a variety of tests, study the results carefully, and then run more
tests with slightly varied conditions, writing computer programs using the extensive SCPI
command set may seem burdensome. This is when you should download the latest copy
of the Keysight AC power source/analyzer graphical user interface from
www.keysight.com/nd/6800.
The AC power source/analyzer GUI makes it quick and easy to set the output of your AC
power source/analyzer, be it from a stored waveform or with a waveform that you create
using your mouse. The GUI also allows you to see the output of the AC power source/
analyzer in graphical form, save the results, or dump them directly into a Microsoft Excel
le.
Microsoft Excel link
The direct Excel link feature was recently added to meet the current needs of R&D
engineers. It makes it easy to keep the results of many tests, and makes them easily re-
trievable. With it, the test records resulting from changing conditions can be kept in one
place and easily compared.
Access to raw data often helps in fully understanding test results. For example, small
local peaks may not be evident in processed data. V, I and phase results from harmonic
measurements are particularly susceptible to not showing the complete story in a graph-
ical representation.
Microsoft Excel offers a wide variety of data manipulation and graphical capabilities that
can help an engineer gain the fullest understanding from the test data.
Test suite for avionics equipment
Keysight AC power source/analyzers are well suited for testing equipment intended
for use in the avionics industry which operate at nominally 400 Hz. One of the special
requirements that many manufacturers in this industry must concern themselves with is
testing to meet RTCA DO-160 standards.
05 | Keysight | 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB - Data Sheet
These standards involve both AC and DC immunity tests. The AC power source/analyzer
GUI includes a section devoted to these tests. By using this tool, you can quickly step
through the required set-ups with condence.
Extensive protection to prevent load damage
In addition to overcurrent, overvoltage, overpower and overtemperature protection,
the 6800 series offers output disconnect relays and remote inhibit capability (quickly
disabling the output of the AC power source/analyzers via a TTL signal) to protect the
device under test.
Application information
The 6800 series can help you test and improve your products. You can easily perform:
Static testing–generating and measuring voltage, frequency, and line current for
meeting worldwide specications.
Dynamic testing–generating AC line transients for limit testing and design
verication.
Specialty testing–measuring current harmonic content and creating custom AC
power waveforms (such as a combined AC + DC signal to simulate a telephone ring).
Precompliance regulatory testing —measuring current harmonics, voltage
uctuations and icker emissions and generating voltage and frequency
disturbances and interharmonics to determine product immunity.
Development engineers and test professionals in a wide variety of industries use AC
power source/analyzers. Here are a few examples:
Avionics – Instrumentation, ATE test stations
Computer products – Computers, monitors, peripherals
Consumer products – Home appliances, audio and video equipment, heating/cooling
controls
Electrical products – Relays, transformers, power components, re alarms
Lighting products – Electronic ballasts, compact uorescent bulbs, timers
Motors – AC motors, electronic controllers
Power products – AC/DC adapters, AC/DC power supplies, PBX power supplies,
uninterruptible power supplies
Telecom products – RF ampliers, CATV devices, MUX’s, routers, switches
Dual power
analyzer input
(for V and I)
Keysight supplied
cable
(for V and I)
AC in Output
Line Load
Keysight
supplied
shunt
AC
source
output
Load
Shunt
AC line
cables
(customer supplied)
Equipment
under test
Keysight AC power source/analyzer
with dual power analyzer option
(side view)
Test configuration of efficiency measurement using an Keysight AC source with the 020 dual power analyzer option.
Only need a basic AC source?
The AC6800 Series of basic AC
sources offer models up to 4000 VA
with LAN/LXI Core, USB and optional
GPIB. For more information, see
www.keysight.com/nd/ACSources
Figure 1. Test conguration of efciency measurement using an Keysight AC source with the 020 dual power analyzer option.
06 | Keysight | 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB - Data Sheet
AC Power Source/Analyzer Graphical User Interface
Figure 2. Inrush current measurement
Figure 4. Voltage slew control (brownout)
Figure 6. User dened waveform: noise with spikes Figure 7. Testing of UPS input and output using dual power analyzer - Option 020
Figure 3. Ringer voltage (DC + AC) generation
Figure 5. One cycle AC mains dropout
07 | Keysight | 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB - Data Sheet
Specications
Specications
(at 0 ° to 40 °C unless otherwise specied) 6811B 6812B 6813B
Number of phases 1 1 1
Output ratings (Maximum)
Power 375 VA 750 VA 1750 VA
rms voltage 300 V 300 V 300 V
rms current 3.25 A 6.5 A 13 A
Repetitive & non-repetitive peak current 40 A 40 A 80 A
Crest factor 12 6 6
Load power factor capability 0 to 1 0 to 1 0 to 1
DC power 285 W 575 W 1350 W
DC voltage ± 425 VA ± 425 V ± 425 V
DC current 2.5 A 5.0 A 10.0 A
Output frequency range1DC; 45 Hz to 1 kHz DC; 45 Hz to 1 kHz DC; 45 Hz to 1 kHz
Constant voltage ripple and noise
(20 kHz to 10 MHz)
–60 dB
(relative to full scale)
–60 dB
(relative to full scale)
–60 dB
(relative to full scale)
Line regulation (% of full scale) 0.1% 0.1% 0.1%
Load regulation (% of full scale) 0.5% 0.5% 0.5%
Maximum total harmonic distortion 0.25% at 50/60 Hz 0.25% at 50/60 Hz 0.25% at 50/60 Hz
1% worst case 1% worst case 1% worst case
45 to 1 kHz 45 to 1 kHz 45 to 1 kHz
Programming accuracy (at 25 ° ± 5 °C) 6811B 6812B 6813B
RMS voltage (% of output + offset) 0.15% + 0.3 V
(45 to 100 Hz)
0.15% + 0.3 V
(45 to 100 Hz)
0.15% + 0.3 V
(45 to 100 Hz)
0.5% + 0.3 V
(> 100 to 500 Hz)
0.5% + 0.3 V
(> 100 to 500 Hz)
0.5% + 0.3 V
(> 100 to 500 Hz)
1% + 0.3 V
(> 500 to 1000 Hz)
1% + 0.3 V
(> 500 to 1000 Hz)
1% + 0.3 V
(> 500 to 1000 Hz)
DC voltage 0.1% + 0.5 V 0.1% + 0.5 V 0.5% + 0.3 V
Frequency 0.01% + 10 μHz 0.01% + 10 μHz 0.01% + 10 μHz
For a sine wave with a resistive load at 0 ° to 40 °C, within an output frequency range of 45 Hz to 1000 Hz,
and in AC coupled mode after a 30 minute warm-up unless otherwise noted.
1. Product may be operated between DC and 45 Hz subject to certain deratings. Measurements may be extended to 4.5 Hz at full accuracy
only by selecting a digitization rate of 250 μs per point. Frequency content of the measured signal must be limited to 4 kHz or less to avoid
aliasing effects.
08 | Keysight | 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB - Data Sheet
Specications, continued
1. Product may be operated between DC and 45 Hz subject to certain deratings. Measurements may be extended to 4.5 Hz at full accuracy
only by selecting a digitization rate of 250 μ seconds per point. Frequency content of the measured signal must be limited to 4 kHz or less to
avoid aliasing effects.
2. Select low measurement range for improved accuracy (10:1) for lower power measurements.
Measurement accuracy (at 25 ° ± 55 °C) 6811B 6812B 6813B
Rms. voltage (45 - 100 Hz) 0.03% + 100 mV10.03% + 100 mV10.03% + 100 mV1
DC voltage 0.05% + 150 mV10.05% + 150 mV10.05% + 150 mV1
RMS current (45 - 100 Hz)2
High range 0.05% + 10 mA 0.05% + 10 mA 0.05% + 10 mA
Low range 0.05% + 1.5 mA 0.05% + 1.5 mA 0.05% + 1.5 mA
Power (VA) (45-100 Hz)2
High range 0.1% + 1.5 VA + 12 mVA/V 0.1% + 1.5 VA + 12 mVA/V 0.1% + 1.5 VA + 12 mVA/V
Low range 0.1% + 1.5 VA + 1.2 mVA/V 0.1% + 1.5 VA + 1.2 mVA/V 0.1% + 1.5 VA + 1.2 mVA/V
Power (watts) (45-100 Hz)2
High range 0.1% + 0.3 W + 12 mW/V 0.1% + 0.3 W + 12 mW/V 0.1% + 0.3 W + 12 mW/V
Low range 0.1% + 0.3 W + 1.2 mW/V 0.1% + 0.3 W + 1.2 mW/V 0.1% + 0.3 W + 1.2 mW/V
Frequency 0.01% + 0.01 Hz 0.01% + 0.01 Hz 0.01% + 0.01 Hz
Power factor 0.01 0.01 0.01
Current magnitude (low range)
Fundamental 0.03% + 1.5 mA 0.03% + 1.5 mA 0.03% + 1.5 mA
Harmonics 2-49 0.03% + 1 mA + 0.2%/kHz 0.03% + 1 mA + 0.2%/kHz 0.03% + 1 mA + 0.2%/kHz
Current magnitude (high range)
Fundamental 0.05% + 5 mA 0.05% + 5 mA 0.05% + 5 mA
Harmonics 2-49 0.05% + 3 mA + 0.2%/kHz 0.05% + 3 mA + 0.2%/kHz 0.05% + 3 mA + 0.2%/kHz
Supplemental characteristics
(Non-warranted characteristics determined
by design and useful in applying the product)
6811B 6812B 6813B
Average programming accuracy
(% of output + offset) rms current 1.2% + 50 mA 1.2% + 50 mA 1.2% + 50 mA
Average programming resolution
rms voltage 125 mV 125 mV 125 mV
DC voltage 250 mV 250 mV 250 mV
Overvoltage programming (OVP) 2 V peak 2 V peak 2 V peak
rms current 2 mA 4 mA 4 mA
Peak current 1.25 mA 25 mA 25 mA
Output frequency 10 μHz 10 μHz 10 μHz
Phase N/A N/A N/A
For a sine wave with a resistive load at 0 ° to 40 °C, within an output frequency range of 45 Hz to 1000 Hz, and in AC
coupled mode after a 30 minute warm-up unless otherwise noted.
09 | Keysight | 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB - Data Sheet
Specications, continued
Supplemental characteristics
(Non-warranted characteristics determined
by design and useful in applying the product)
6811B 6812B 6813B
Average measurement resolution
rms voltage 10 mV 10 mV 10 mV
rms current 2 mA 2 mA 2 mA
Programmable output impedance
Resistance 0 – 1 Ω 0 – 1 Ω 0 – 1 Ω
Inductance 20 μh – 1 mh 20 μh – 1 mh 20 μh – 1 mh
Remote sense capability Up to 1 Vrms can be
dropped across each load
lead
Up to 1 Vrms can be
dropped across each load
lead
Up to 1 Vrms can be
dropped across each load
lead
Isolation to ground 300 Vrms/425 VDC 300 Vrms/425 VDC 300 Vrms/425 VDC
Net weight 28.2 kg (62 lb) 28.2 kg (62 lb) 32.7 kg (72 lb)
Shipping weight 31.8 kg (70 lb) 31.8 kg (70 lb) 36.4 kg (80 lb)
AC input ratings 6811B 6812B 6813B
Voltage range (VAC)
*default factory setting 87 to 106 VAC
*104 to 127 VAC
87 to 106 VAC
*104 to 127 VAC
174 to 220 VAC
*191 to 254 VAC
174 to 220 VAC 174 to 220 VAC
191 to 254 VAC 191 to 254 VAC
Maximum input current (rms)
(Measured at low line)
12 A (100 VAC) 28 A (100 VAC) 22 A (200/208 VAC)
10 A (120 VAC) 24 A (120 VAC)
7.5 A (200/208 VAC) 15 A (200/208 VAC) 20 A (230 VAC)
6.5 A (230 VAC) 13 A (230 VAC)
Input power (max)
(Measured at high line)
1000 VA/700 W 2500 VA/1400 W 3800 VA/2600 W
Input frequency 47 to 63 Hz 47 to 63 Hz 47 to 63 Hz
For a sine wave with a resistive load at 0 ° to 40 °C, within an output frequency range of 45 Hz to 1000 Hz, and in AC
coupled mode after a 30 minute warm-up unless otherwise noted.
Supplemental characteristics for all model numbers
Software driver: VXIplug&play
Size: 425.5 mm W x 88.1 mm H x 396 mm D (16.75 in x 3.5 in x 13.7 in )
Warranty: Three years
10 | Keysight | 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB - Data Sheet
The 6800 Series AC power source/analyzers come with full documentation on CD-ROM. The CD-ROM includes user’s guide,
programming guide, GUI quick reference guide, service manual, quick start guide, and application notes.
Opt 019 Output raised to 2000VA, frequency reduced to 100Hz (6813B only)
Opt 020 Dual power analyzer option
Opt 026 26 Volt, 0.1 A auxiliary 45 to 100 Hz only, reference output (6812B and 6813B)
Opt 0B3 Printed service manual
Opt 0L1 Printed users, programming, and quick start guides; printed reference card
Opt 100 (6811B and 6812B only) 87 to 106 VAC (100 VAC nominal), 47-63 Hz, Japan only
Opt 120 104-127 VAC (120 VAC nominal), 47-63 Hz
Opt 200 (6813B only) 174-220 VAC (200 VAC nominal), 47-63 Hz, Japan only
Opt 208 (6811B and 6812B only) 174 to 220 VAC (208 VAC nominal), 47-63 Hz
Opt 230 191 to 254 VAC (230 VAC nominal), 24-63 Hz
Opt 831 12 AWG, 200 to 240 VAC, unterminated (6812B, 6813B only)
Opt 832 4 mm2 wire size, (unterminated (6813B only)
Opt 833 1.5 mm2 wire size, 200 to 240 VAC, unterminated (6812B only)
Opt 834 10 AWG, 100 to 120 VAC, unterminated (6812B only)
Opt 841 Line cord with NEMA L6-20P; 20 A, 250 V plug (6812B only)
Opt 842 Line cord with IEC 309; 32 A, 220 V plug (6813B only)
Opt 844 Line cord with NEMA L6-30P; 30 A, 250 V locking plug (6813B only)
Opt 845 Line cord with IEC 309; 16 A, 220 V plug (6812B only)
Opt 846 Line cord with NEMA L6-30P; 30 A, 120 V plug (6812B only)
Opt 847 Line cord with CEE 7/7; 16 A, 220 V plug (6812B only)
Opt 848 Line cord with BS 546; 15 A, 240 V plug (6812B only)
Accessories
1CM003A1 Rack mount ange kit 132.6 mm H (3U) – two ange brackets
1CP002A1 Rack mount ange and handle kit 132.6 mm H (3U) – two brackets and front handles
E3663AC Support rails for Keysight rack cabinets
1. Support rails required.
Ordering Information
11 | Keysight | 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB - Data Sheet
Application Notes
Keysight 6800 Series AC Power Source/Analyzer - Application Note
http://literature.cdn.keysight.com/litweb/pdf/5963-7044E.pdf
5963-7044E
Testing Uninterruptible Power Supplies Using Keysight 6800 Series AC Power Source/Analyzers - Application Note
http://literature.cdn.keysight.com/litweb/pdf/5967-6056E.pdf
5967-6056E
Simplify your Avionics Testing with a 400 Hz Single Phase Power Source that Includes a Built-in 26 V Reference
Signal - Application Note
http://literature.cdn.keysight.com/litweb/pdf/5989-3700EN.pdf
5989-3700EN
Figure 8. Keysight models: 6811B, 6812B, 6813B
574.7 mm
22.63"
425.5 mm
16.75"
12.7 mm
0.5"
50.8 mm
2.0"
128 mm
5.04"
Terminal strip
Screw size: 6-32
132.6 mm
5.2"
Rear
Top
Side
Top
Side
Rear
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty
Keysight’s commitment to superior product quality and lower total cost
of ownership. The only test and measurement company with three-year
warranty standard on all instruments, worldwide.
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to five years of protection and no budgetary surprises to ensure your
instruments are operating to specification so you can rely on accurate
measurements.
www.keysight.com/go/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2008
Quality Management System
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and product
breadth, combined with channel partner convenience.
Unlocking Measurement Insights
For more than 75 years we have been helping you unlock measure-
ment insights, rst as the electronic measurement businesses of
Hewlett-Packard and Agilent Technologies, and now, as Keysight
Technologies. Our unique combination of hardware, software and
people can help you see what others can’t, so you can reach your
next breakthrough.
www.keysight.com/find/ACSources
This information is subject to change without notice.
© Keysight Technologies, 2012 - 2015
Published in USA, March 12, 2015
5990-9309EN
www.keysight.com
12 | Keysight | 6800B Series AC Power Source/Analyzers, 375-1750 VA, GPIB - Data Sheet
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada (877) 894 4414
Brazil 55 11 3351 7010
Mexico 001 800 254 2440
United States (800) 829 4444
Asia Pacic
Australia 1 800 629 485
China 800 810 0189
Hong Kong 800 938 693
India 0124 229 2010
Japan 0120 (421) 345
Korea 080 769 0800
Malaysia 1 800 888 848
Singapore 1 800 375 8100
Taiwan 0800 047 866
Other AP Countries (65) 6375 8100
Europe & Middle East
Austria 0800 001122
Belgium 0800 58580
Finland 0800 523252
France 0805 980333
Germany 0800 6270999
Ireland 1800 832700
Israel 1 809 343051
Italy 800 599100
Luxembourg +32 800 58580
Netherlands 0800 0233200
Russia 8800 5009286
Spain 800 000154
Sweden 0200 882255
Switzerland 0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
United Kingdom 0800 0260637
For other unlisted countries:
www.keysight.com/find/contactus
(BP-02-06-15)