786 Series www.murata-ps.com General Purpose Pulse Transformers n Industry standard pinout n Surface mount option n UL 94 V-0 package materials n Low profile n Toroidal construction n Fully encapsulated DESCRIPTION The 786 series is a comprehensive range of general purpose pulse transformers. Common applications include line coupling, matching or isolating. The devices can also be used in small isolated power supplies and also as commonmode chokes in filtering applications. Surface-mount parts The surface-mount (M suffix) products are not recommended for new designs. For existing designs, however, Murata Power Solutions will continue to manufacture and fully support these parts. For recommended alternatives please refer to the 786J Series datasheet. H Vs H pF Vrms 67 200 500 1000 2000 4000 10000 67 200 500 1000 2000 4000 10000 67 200 500 1000 2000 4000 10000 67 200 500 1000 2000 4000 10000 67 200 500 1000 2000 4000 10000 4 6 10 15 20 28 56 4 6 10 15 20 28 56 4 6 10 15 20 28 56 4 6 10 15 20 28 56 4 6 10 15 20 28 56 0.19 0.20 0.25 0.29 0.47 0.47 0.86 0.11 0.17 0.27 0.35 0.60 0.71 0.71 0.41 0.49 0.65 0.76 0.99 1.61 1.64 0.30 0.65 1.07 1.13 1.53 1.98 3.83 1.21 3.64 6.86 11.9 16.0 37.7 44.5 8 14 22 35 49 78 121 12 19 32 47 72 116 167 4 9 13 20 29 50 72 7 12 20 35 47 64 72 3 5 7 10 16 20 19 0.17 0.25 0.34 0.45 0.60 0.84 1.30 0.18 0.24 0.34 0.46 0.66 0.92 1.34 0.18 0.25 0.34 0.46 0.60 0.85 1.23 0.20 0.25 0.36 0.48 0.63 0.88 1.33 0.17 0.24 0.34 0.45 0.60 0.87 1.33 Winding Configuration Isolation Voltage n 1kVrms isolation Max. DC Resistance n Primary inductance to 10mH 1:1 1:1 1:1 1:1 1:1 1:1 1:1 1:1:1 1:1:1 1:1:1 1:1:1 1:1:1 1:1:1 1:1:1 2:1 2:1 2:1 2:1 2:1 2:1 2:1 1CT:1 1CT:1 1CT:1 1CT:1 1CT:1 1CT:1 1CT:1 1CT:1CT 1CT:1CT 1CT:1CT 1CT:1CT 1CT:1CT 1CT:1CT 1CT:1CT Typ. Interwinding Capacitance n 4 Configurations 78601/4C 78601/3C 78601/2C 78601/8C 78601/1C 78601/16C 78601/9C 78602/4C 78602/3C 78602/2C 78602/8C 78602/1C 78602/16C 78602/9C 78604/4C 78604/3C 78604/2C 78604/8C 78604/1C 78604/16C 78604/9C 78613/4C 78613/3C 78613/2C 78613/8C 78613/1C 78613/16C 78613/9C 78615/4C 78615/3C 78615/2C 78615/8C 78615/1C 78615/16C 78615/9C Typ. Leakage Inductance n RoHS compliant Turns Ratio Primary Min. Volt-time Product, Et FEATURES Order Code Min. Primary Inductance SELECTION GUIDE 1000 1 1000 2 1000 1 1000 3 1000 4 ORDER CODE DETAILS Order Code 786XX/XC 786XX/XMC 786XX/XMC-R Package Type 6 Pin DIL 6 Pin SM 6 Pin SM Packaging Type Tube Tube Tape & Reel Quantity 50 50 500 ABSOLUTE MAXIMUM RATINGS Operating free air temperature range Storage temperature range 0C to 70C -60C to 125C SOLDERING INFORMATION1 Pin finish Peak wave solder temperature Peak reflow temperature2 For full details go to For full details go to www.cd4power.com/rohs www.murata-ps.com/rohs Matte tin 300C for 10 seconds 220C All specifications typical at TA=25C 1 For further information, please visit www.murata-ps.com/rohs 2 For higher temperature reflow variants see 786J series datasheet www.murata-ps.com/support KMP_786C_B07 Page 1 of 4 786 Series General Purpose Pulse Transformers PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS 6 Pin SMD Package Style 6 Pin DIL Package Style 12.70 (0.5) 9.52 (0.375) Max. 9.0 (0.354) Max. 9.52 (0.375) Max. 9.0 (0.354) 78601/1C 78601/1MC XYYWW XYYWW 6.35 (0.25) 6.35 (0.25) 3.440.50 (0.1350.02) 0.30 (0.012) 0.20 (0.007) 0.30 (0.012) 0.20 (0.008) 10.16 (0.4) 5.08 (0.2) 0.63 (0.025) 0.53 (0.021) 0.90 (0.04) 2.54 (0.1) 0.63 (0.025) 0.53 (0.021) Unless otherwise stated all dimensions in mm (inches) 0.25 (0.01). All pins on a 2.54 (0.1) pitch and within 0.25 (0.01) of true position. Package Weight: 1.1g Typ. RECOMMENDED FOOTPRINT DETAILS 6 Pin DIL 6 Pin SM (0.10) 2.542.54 (0.10) 1.601.60 (0.06) (0.06) 2.54 2.54 (0.10)(0.10) 2.542.54 (0.10) (0.10) +0.15 (0.006) +0.15 (0.006) O1.20 (0.05) O1.20 (0.05) -0.00 (0.000) -0.000 (0.00) 1.001.00 (0.04) (0.04) 11.50 11.50 (0.45) (0.45) Unless otherwise stated all dimensions in mm (inches) 0.25 (0.01). All pins on a 2.54 (0.1) pitch and within 0.25 (0.01) of true position. WINDING CONFIGURATION - 6 PIN DIL/SMD (TOP VIEW) 1 1 2* Pri 3 3 2 Sec 6 5* 4 1 2 3 Pri Sec 1 Sec 2 6 5 4 1 2 3 4 Pri Sec 6 5* 4 1 2 3 Pri Sec 6 5 4 * Pins only fitted on 786XX/XMC and 786XX/XMC-R variants. www.murata-ps.com/support KMP_786C_B07 Page 2 of 4 786 Series General Purpose Pulse Transformers TAPE & REEL SPECIFICATIONS REEL OUTLINE DIMENSIONS 60 (2.36) Min. O382 (15.039) Min. 23.9-27.4 (0.94-1.08)* O 13.50 (0.53) 12.80 (0.50) Leader section 400 (15.7) Min. 100 (3.9) Min. 1.50 (0.059) Min. 30.4 (1.20) Max. Goods enclosure section 24.4 (0.96) 26.4 (1.04) Trailer section 160 (6.3) Min. Unless otherwise stated all dimensions in mm (inches) 0.25 (0.01). O 20.20 (0.80) Min. * Includes flange distortion at outer edge. Measured at hub. TAPE OUTLINE DIMENSIONS 11.50 (0.453) 4.00 (0.157) +0.004 +0.10 1.50 -0.00 (0.059 -0.000 ) 2.00 (0.079) XYYWW 78601/1C +0.012 24.00 +0.30 -0.10 (0.945 -0.004 ) 1.75 (0.069) Cover tape 7.20 (0.283) 9.37 (0.369) 12.00 (0.472) 0.60 (0.024) Max. Direction of unreeling Unless otherwise stated all dimensions in mm (inches) 0.25 (0.01). www.murata-ps.com/support KMP_786C_B07 Page 3 of 4 786 Series General Purpose Pulse Transformers TECHNICAL NOTES TUBE OUTLINE DIMENSIONS ISOLATION VOLTAGE 10.95 (0.43) 4.00 (0.16) 0.600.15 (0.0230.005) 12.95 (0.51) 5.50 (0.22) 3.80 (0.15) 15.70 (0.62) Tube length: 4652 (18.30.08). Tube quantity: 50. Tube material: Antistatic coated clear pvc. Unless otherwise stated all dimensions in mm (inches) 0.25 (0.01). Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED `Hi Pot Test', `Flash Tested', `Withstand Voltage', `Proof Voltage', `Dielectric Withstand Voltage' & `Isolation Test Voltage' are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. All products in this series are 100% production tested at their stated isolation voltage. A question commonly asked is, "What is the continuous voltage that can be applied across the part in normal operation?" For a part holding no specific agency approvals both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. This series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2011 Murata Power Solutions, Inc. www.murata-ps.com/support KMP_786C_B07 Page 4 of 4