BULLETIN PT-6
Model KS Sanitary
Pressure Transmitter
The Ashcroft trade name has
been synonymous with pres-
sure for over 150 years. Since
1987, the Transducer Operation
of Dresser Instrument Division
has been manufacturing quality
industrial pressure transducers
serving a multitude of markets.
Whatever your application, we
have the technology to provide
either standard or customized
designs to fit your requirements.
Each pressure transducer is
100% tested and calibrated in
our ISO-9001 certified facility in
Milford, Connecticut. The com-
mitment of our engineering
staff, direct sales force and dis-
tribution network ensure that
the service and application
expertise you need to maintain
safety and performance in your
application is always available
when and where you need it.
The people of Dresser
Instrument Division are here to
provide the best quality prod-
ucts and service best suited to
our customer’s needs.
The KS sanitary pressure
transmitter combines a
pro ven thin film sensor tech-
nology and 3A standards f or
sanitary applications.
• Dairy
• Food processing
Pharmaceutical
• Biotech
TRANSDUCER OPERATIONS
ELECTRICAL SPECIFICATIONS
Output Signal: Supply Voltage:
4-20mA (2 wire) 10-36 Vdc
1-5 Vdc (3 wire) 10-36 Vdc
1-6 Vdc (3 wire) 10-36 Vdc
2mV/V ratiometric 5-10 Vdc regulated
3mV/V ratiometric 5-10 Vdc regulated
10mV/V ratiometric 5-10 Vdc regulated
20mV/V ratiometric 5-10 Vdc regulated
Reverse polarity protected
Supply Current: Less than 3mA for voltage
output
Circuit to Case Insulation Resistance:
100 M ohms @ 50 Vdc
PHYSICAL SPECIFICATIONS
Standard Process Connections:
(316L stainless steel)
Tri-Clamp®style 112,˝ 2˝.
Enclosure: NEMA 4X, (NEMA 1 only if <500
psig and electrical termination is Bendix®or
Hirschmann®).
Case: 300 series stainless steel
Cable: No. 24 AWG, 36˝ PVC, shielded,
vented, UL approved.
Diaphragm: 316L stainless steel electro-
polished
Fill: USP grade 99.5% glycerin fill, contact
factory for other fill fluids.
W eight: 13.5 oz. (approx. without cable)
Consult factory for pricing, availability and
required minimums for non-standard
products.
WARNING! Sensitive diaphragm! Do not
touch! Remove protective-cap just before
installation!
Bendix®is registered trademark of Amphenol Corp.
Hirschmann®is registered trademark of Richard Hirschmann
of America Inc.
Tri-Clamp®is a registered trademark of Tri-Clover, Inc.
PERFORMANCE CHARACTERISTICS
Accuracy Class (F.S.): 1.0%
Nonlinearity
Terminal Point* ± 0.7%
B.F.S.L. ±0.4%
Hysteresis ±0.2%
Nonrepeatability ±0.07%
*Including hysteresis
Standard Ranges (psi):
0/30*† 0/300† Vac/30†
0/60*† 0/500 Vac/60†
0/100† 0/750 Vac/100†
0/150† 0/1000
0/200†
Consult factory for non-standard ranges.
*T/C multiply by 1.5 times
†NEMA 4X only with F2 and C1 electrical connections.
Stability: ±1% F.S./year
Durability: 107cycles 20/80% F.S. with
negligible performance change
Response Time: Less than 5m sec.
ENVIRONMENTAL SPECIFICATIONS
Temperature Limits:
Storage –65/+250°F
Operating –20/+180°F
Compensated +30/+130°F
Thermal Coefficients (68°F ref.):
Zero ± 0.04% F.S./°F
Span ±0.04% F.S./°F
Humidity: No performance effect at 95%
relative humidity-noncondensing
FUNCTIONAL SPECIFICATIONS
Overpressure (F.S.):
Proof 200%
Burst 800%
Vibration Sweep:
Less than ± 0.1% F.S. effect for 0-2000 Hz at
20 g's in any axis
Shock: Less than ±0.05% F.S. effect for
100 g's, 20 ms shock in any axis
Position Effect: Less than 0.1% F.S.
Model KS Pressure Transducer/Transmitter
Dimensions
Vmin = 10V+ (.022A x RL)
RL= RS+ RW
RL= Loop Resistance (ohms)
RS= Sense Resistance (ohms)
RW= Wire Resistance (ohms)
D
A
C
B
MODEL ABCD
S15 0.8 4.7 0.9 2.0
S20 0.8 4.7 0.9 2.5
1000
750
500
250
0
0362010
1182
30
Load Limitations 4-20mA Output Only
(R
LOOP )
38 WELLINGTON ROAD
MILFORD, CT. 06460
(203) 783-6650 Customer Service
(203) 783-6659 FAX
www.dresser.com/instruments
All specifications are subject to change without notice. All sales subject to standard terms and conditions. © Dresser Instrument Division 11/97 20MCP 1P 1/94 6P 11/97
How To Order KS #
7
Type Configuration
(KS) Sanitary Seal
(S15) 112˝ Sanitary Connection
(S20) 2˝ Sanitary Connection
Electrical Termination
(F2) 36˝ Cable, Shielded, PVC Sheathing
(B6) Bendix 6-pin #PTO2A-10-6P*
(B9) WP Bendix 6-pin #PTO2H-10-6P*
(B4) Bendix 4-pin #PTO2A-8-4P*
(B8) WP Bendix 4-pin #PTO2H-8-4P*
(C1) 12NPT-M Conduit and 36˝ Cable
(HM) Hirschmann Miniature
Accuracy
(7) 1.0%, ±0.040%/°F Output Signal
(42) 4-20mA
(16) 1-6 Vdc
(15) 1-5 Vdc
(02) 2mV/V
(03) 3mV/V
(10) 10mV/V
(20) 20mV/V
Pressure Range
(30) 30 psi
(60) 60 psi
(100) 100 psi
(150) 150 psi
(200) 200 psi
(300) 300 psi
(500) 500 psi
(750) 750 psi
(1000) 1000 psi
(Vac/30) Vac/30
(Vac/60) Vac/60
(Vac/100) Vac/100
*Mating connector available as option