65W Quad Output Switching Power Supply RQ-65 series @ Features : * Universal AC input / Full range Protections:Short circuit / Overload / Over voltage Cooling by free air convection LED indicator for power on 100% full load burn-in test All using 105C long life electrolytic capacitors Withstand 300VAC surge input for 5 second High operating temperature up to 70C Withstand 5G vibration test High efficiency, long life and high reliability 3 years warranty (A) [CE SPECIFICATION coven 368-1 1EC62368-1 TPTC004 MODEL RQ-65B RQ-65C RQ-65D OUTPUT NUMBER CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4 DC VOLTAGE 5V 12V -5V -12V 5V 15V -5V -15V 5V 12V 24V -12V RATED CURRENT 6A 2A 0.5A 0.5A 5A 2A 0.5A 0.5A 4A 1.5A 1A 0.5A CURRENT RANGE Note.6}0~8A |0~3A |0~1A |0~1A |0~8A |0~3A |0~1A |0~1A |0~8A |0~3A_ |0~1.5A |0~1A RATED POWER Note.6 | 62.5W 65W 68W OUTPUT [RIPPLE & NOISE (max.) Note.2| 80mVp-p [120mVp-p| 80mVp-p | 80mVp-p | 80mVp-p | 120mVp-p| 80mVp-p | 80mVp-p | 80mVp-p | 120mVp-p| 180mVp-p| 80mVp-p VOLTAGE ADJ. RANGE CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V CH1: 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3}+2.0% | +9,-5% |+5.0% /+5.0% [|+2.0% |+10,-4% |+5.0% |+5.0% |+2.0% | +6,-10% |+6,-10% | +5.0% LINE REGULATION Note.4) +0.5% [|+1.5% |+0.5% | 40.5% |+0.5% [+1.5% |+0.5% |+0.5% |+0.5% |+1.5% |+2.0% | +0.5% LOAD REGULATION Note.5}+0.5% | 43.0% [41.0% [+1.0% {40.5% |+4.0% [41.0% [+1.0% |+40.5% (43.0% [|+5.0% | +1.0% SETUP, RISE TIME 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 60ms/230VAC 14ms/115VAC at full load VOLTAGE RANGE 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) FREQUENCY RANGE 47 ~ 63Hz INPUT _ [EFFICIENCY (Typ.) 75% [ 75% | 77% AC CURRENT (Typ.) 2A/115VAC 1.2A/230VAC INRUSH CURRENT (Typ.) COLD START 50A/230VAC LEAKAGE CURRENT <2mA/ 240VAC 110 ~ 150% rated output power PROTECTION OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1: 5.75 ~ 6.75V OVER VOLTAGE Protection type : Hiccup mode, recovers automatically after fault condition is removed WORKING TEMP. -25 ~ +70C (Refer to "Derating Curve") WORKING HUMIDITY 20 ~ 90% RH non-condensing ENVIRONMENT | STORAGE TEMP., HUMIDITY | -40 ~ +85C, 10 ~ 95% RH TEMP. COEFFICIENT +0.03%/C (0 ~ 50C)on +5V output VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL62368-1, TUV EN62368-1, EAC TP TC 004 approved SAFETY & | WITHSTAND VOLTAGE \/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC EMC ISOLATION RESISTANCE \/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25C/ 70% RH (Note 7) EMC EMISSION Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteriaA, EAC TP TC 020 MTBF 245.5Khrs min. | MIL-HDBK-217F (25C) OTHERS | DIMENSION 129*98*38mm (L*W*H) PACKING 0.44Kg; 30pces/13.2Kg/0.72CUFT NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25C of ambient temperature. . Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. . Tolerance : includes set up tolerance, line regulation and load regulation. . Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load. . Each output can work within current range. But total output power can't exceed rated output power. 2 3 4. Line regulation is measured from low line to high line at rated load. 5 6 7 . The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http:/Awww.meanwell.com) 8. The ambient temperature derating of 3.5C/1000m with fanless models and of 5C/1000m with fan models for operating altitude higher than 2000m(6500ft) File Name:RQ-65-SPEC 2019-07-11MW MEAN WELL 65W Quad Output Switching Power Supply RQ-65N series i Mechanical Specification Case No. 903 Unit:mm 4 Hi Derating Curve CONTROL LOAD (%) -25 0 AMBIENT TEMPERATURE (C) 70 (VERTICAL) Hi Output Derating VS Input Voltage LOAD (%) 122.5 . rit = (T] os Woe, * TADS 2 ig W'S | | Hor 5 meu, 3 oS TASS Ws, 4 hor 3 2 2 LI < |. co That LI & |. maar st WS ls | g38O im em =) 4.5 [ 73.5 129 6.5 120 Terminal Pin No. Assignment oo == Pin No. Assignment Pin No. Assignment & | 12 ~o 1 ACIL 5 DC OUTPUT V3 oe 16 dy, | 2 | 19] ya | ~ 2 2 ACIN 6 | DC OUTPUT +V2 S = 6 3 FG = 7 | DCOUTPUTCOM > 4 DC OUTPUT -V4 8 | DCOUTPUT+V1 | 32 77 ; RECTIFIERS Hi Block Diagram EY eter o +V4 fosc : 6(0KHz : RECTIFIERS | & +V3 FILTER E RECTIFIERS _| & o +V2 FILTER UP o EMI RECTIFIERS POWER | RECTIFIERS o +4V1 FILTER FILTER SWITCHING FILTER com 1 | 100 F 90 80 70 40 4 1 L 1 1 L 1 1 L 1 L L 88 95 100 15 120 140 160 INPUT VOLTAGE (VAC) 60Hz 180 200 220 240 264 File Name:RQ-65-SPEC 2019-07-11