G3VM-61BR1/ER1 MOS FET Relays DIP Higher power, 3-A switching with a 60-V load voltage, DIP package. Low 40 m ON Resistance. * Continuous load current of 3 A. (Connection C: 6 A) * Switches minute analog signals. G3VM-61BR1/ER1 * Dielectric strength of 2,500 Vrms between I/O. RoHS compliant Note: The actual product is marked differently from the image shown here. Application Examples Terminal Arrangement/Internal Connections 6 * Communication equipment 5 4 * Test & Measurement equipment OMRON logo Model name * Security equipment 932 Pin 1 mark Lot No. * Factory Automation equipment 1 * Power circuit 3 2 Note: The actual product is marked differently from the image shown here. List of Models Package type Contact form DIP6 1a (SPST-NO) Load voltage (peak value) * Terminals PCB terminals Minimum package quantity Model Number per stick Number per tape and reel G3VM-61BR1 60 V Surface-mounting terminals G3VM-61ER1 G3VM-61ER1 (TR) 50 --- --- 1,500 * The AC peak and DC value are given for the load voltage. Absolute Maximum Ratings (Ta = 25C) Input Item LED forward current Repetitive peak LED forward current LED forward current reduction rate LED reverse voltage Connection temperature Load voltage (AC peak/DC) Connection A Continuous Connection B load current Connection C Connection A ON current Connection B reduction rate Connection C Pulse ON current Connection temperature Dielectric strength between I/O (See note 1.) Operating temperature Storage temperature Output Soldering temperature Symbol IF IFP IF/C VR TJ VOFF IO IO/C Iop TJ VI-O Ta Tstg --- Rating 30 1 -0.3 5 125 60 3 3 6 -30 -30 -60 9 125 2500 -40 to +85 -55 to +125 260 Unit mA A mA/C V C V A mA/C A C Vrms C C C Measurement conditions Note: 100 s pulses, 100 pps Ta 25C 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. Connection Diagram Connection A: AC peak/DC Connection B and C: DC Ta 25C Connection A Connection B t = 100 ms, Duty = 1/10 AC for 1 min With no icing or condensation With no icing or condensation Connection C 10 s 1 6 2 5 3 4 1 6 2 5 3 4 1 6 2 5 3 4 Electrical Characteristics (Ta = 25C) Input Item Symbol Minimum Typical Maximum LED forward voltage VF 1.18 1.33 1.48 Reverse current IR ----10 Capacity between terminals CT --70 --Trigger LED forward current IFT --0.5 3 Connection A --40 70 Maximum resistance with Connection B RON --20 --output ON Connection C --10 --Current leakage when the relay is open ILEAK ----1.0 Capacity between terminals COFF --1000 --Capacity between I/O terminals CI-O --0.8 --Insulation resistance between I/O terminals RI-O 1000 ----Turn-ON time tON --2 5 Turn-OFF time tOFF --0.1 1 Output 1 Unit V A pF mA m m m A pF pF M ms ms Measurement conditions IF = 10 mA VR = 5 V V = 0, f = 1 MHz Note: IO = 1 A IF = 5 mA, IO = 2 A, t < 1s IF = 5 mA, IO = 2 A, t < 1s IF = 5 mA, IO = 4 A, t < 1s VOFF = 60 V V = 0, f = 1 MHz f = 1 MHz, VS = 0 V VI-O = 500 VDC, ROH 60% IF = 5 mA, RL = 200 , VDD = 20 V (See note 2.) 2. Turn-ON and Turn-OFF Times IF 1 6 2 4 RL VDD VOUT IF VOUT 10% t ON 90% t OFF Load AC or DC Load DC Load DC G3VM-61BR1/ER1 MOS FET Relays Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Load voltage (AC peak/DC) Typical Maximum Unit --- --- 48 V IF 5 10 25 mA Continuous load current (AC peak/DC) IO --- --- 3 A Operating temperature Ta -20 --- 65 C DIP VDD Operating LED forward current Engineering Data Continuous load current vs. Ambient temperature LED forward current vs. LED forward voltage IO - Ta 40 30 20 IF - VF 10 LED forward current IF (mA) Continuous load current IO (A) LED forward current IF (mA) IF - Ta 50 G3VM-61BR1/ER1 LED forward current vs. Ambient temperature Connection C 5 Connection A, Connection B 100 Ta = 25C 10 1 0.1 10 0 0 -40 -20 0 20 40 60 80 0.01 -40 100 -20 0 20 Ambient temperature Ta (C) Continuous load current vs. On-state voltage 80 100 0 0.5 1 IF = 5mA Connection A 2 1 0 -1 IFT - Ta 100 IO = 2A IF = 5mA, t < 1s 80 2 Trigger LED forward current vs. Ambient temperature Trigger LED forward current IFT (mA) On-state resistance RON (m) Ta = 25C 1.5 LED forward voltage VF (V) RON - Ta IO - VON Continuous load current IO (A) 60 On-state resistance vs. Ambient temperature 4 3 40 Ambient temperature Ta (C) Connection A 60 40 -2 20 2 IO = 1A t < 1s Connection A 1 -3 -4 0 -0.1 0 0.1 0 -40 0.2 -20 0 20 On-state voltage VON (V) Turn ON, Turn OFF time vs. LED forward current tON, tOFF - IF 80 100 VDD = 20V RL = 200 Ta = 25C 10 1 t on t off 0.01 -20 0 VDD = 20V RL = 200 IF = 5mA t on 1 t off 0.1 10 100 40 60 80 100 Ambient temperature Ta (C) ILEAK - Ta 100 10 20 Current leakage vs. Ambient temperature 100 VOFF = 60V 10 1 0.1 0.01 1 -40 tON, tOFF - Ta Turn ON, Turn OFF time tON, tOFF (ms) Turn ON, Turn OFF time tON, tOFF (ms) 60 Turn ON, Turn OFF time vs. Ambient temperature 100 0.1 40 Ambient temperature Ta (C) Current leakage ILEAK (nA) -0.2 0.01 -40 -20 LED forward current IF (mA) 0 20 40 60 80 100 Ambient temperature Ta (C) -40 -20 0 20 40 60 80 100 Ambient temperature Ta (C) Safety Precautions * Refer to "Common Precautions" for all G3VM models. 2 Appearance/Dimensions DIP6 Appearance DIP (Dual Inline Package) DIP6 OMRON logo Model name 932 Pin 1 mark Lot No. Note: The actual product is marked differently from the image shown here. Dimensions (Unit: mm) PCB Terminals Surface-mounting Terminals Weight: 0.4 g PCB Dimensions (Bottom View) Weight: 0.4 g Six, 0.8-dia. holes 2.54 (0.61) 2.54 7.120.25 7.120.25 6.40.25 (0.61) (1.52) (1.52) 6.40.25 Actual Mounting Pad Dimensions 7.620.25 0.80.25 7.620.25 (Recommended Value, Top View) 3.65+0.15 -0.25 0.25+0.1 -0.05 2.5 min. 1.20.15 0.50.1 2.540.25 3.65+0.15 -0.25 4.0+0.25 -0.2 2.54 2.54 1.0 min. 7.85 to 8.80 1.20.15 2.540.25 Note: The actual product is marked differently from the 1.0 min. 8.3 to 8.8 10.0 max. 1.3 image shown here. 1.5 * Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. * Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. K140-E1-02 0412(0412)(O) Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: G3VM-61BR1 G3VM-61ER1 G3VM-61ER1(TR) G3VM-61BR1#S