D5XB40 ........ D5XB100
Maximum Ratings and Electrical Characteristics at 25 ºC
Current
5.0 A
Voltage
400 V to 1000 V
Electrical Characteristics at Tamb = 25 °C
MECHANICAL DATA
IN LINE BIG

Ideal for printed circuit board
UL recognition file number
E320541
High case dielectric strength of 2500 Vrms
5.0 Amp. Glass Passivated Single Phase In Line Bridge Rectifier
TYPICAL APPLICATIONS
Used in ac-to-dc bridge full wave rectification for monitor,
TV, printer, switching mode power supply, adapter, audio
equipment, and home appliances applications.
FEATURES
High surge current capability
Solder dip 260ºC, 10s
Component in accordance to RoHS 2002/95/EC
and WEEE 2002/96/EC
~
~
~~
V
RRM
Peak recurrent reverse voltage (V)
Maximum RMS Voltage (V)
I
FSM
Peak forward surge current 8.3ms single half
sine-wave superimposed on rated load
(Jedec Method)
180 A
V
RMS
T
j
Operating temperature range -40 to +150 °C
I
F(AV)
Max. Average forward current
T
stg
Storage temperature range -40 to +150 °C
400
280
600
420
800
560
D5XB40 D5XB60 D5XB80
I2tI
2
t value for fusing (t = 10 ms)
120 A
2sec
1000
700
D5XB100
VDIS
Dielectric strength (terminals to case, AC 1 min.)
2500 V
5.0 A at Tc: 100 °C
2.8 A at 25 °C
D5XB40 D5XB60 D5XB80 D5XB100
Marking Code
1.00 V
V
F
Max. forward voltage drop per diode at IF = 3.0 A
I
R
Max. instantaneous reverse current at VRRM
5 µA
Junction-case
3.4 °C/W
Rth (j-c)
Rth (j-a)
22 °C/W
Junction-Ambient
Typical Thermal Resistance
(Note 2)
(Note 1)
(Note 2)
(Note 1)
www.fagorelectronica.com
Document Name: d5xb Version: Nov-11
Page Number: 1/4

Case: IN LINE BIG. Epoxy meets UL 94V-0 flammability rating.

Polarity:
As marked on body

Mounting Torque:
10cm-kg (8.8 in.- Ibs.) Max.

Recommended Torque:
5.5cm-kg (5 in.- Ibs.)

Terminals:
Matte tin plated leads, solderable per
MIL-STD-750 Method 2026, J-STD-002 and JESD22-B102.
Consumer grade, meets JESD 201 class 1A whisker test
Notes: 1. Unit case mounted on aluminum plate heatsink
2. Units mounted on P.C.B. without heatsink
D5XB60 TY
Package Outline Dimensions
:
(mm) IN LINE BIG
D5XB40 ........ D5XB100
5.0 Amp. Glass Passivated Single Phase In Line Bridge Rectifier
Ordering information
TY PAPER TRAY 40 7
www.fagorelectronica.com
Document Name: d5xb Version: Nov-11
Page Number: 2/4
PREFERRED P/N PACKAGE CODE DELIVERY MODE BASE QUANTITY UNIT WEIGHT (g)
4.8
9.8
30.3
29.7
10.2
2.7
2.3
2.4
2.0
1.1
0.9
18.0
17.0
4.2
3.8
7.7 7.7
7.3 7.3
4.8
20.3
19.7
0.8
0.6
2.9
2.5
3.4
3.1
3.8
3.4
4.4
11.2
10.8
Marking code
5.0
C.118(3.0)
x45°
MC
Week code
Year code
WWY
D5XB40 ........ D5XB100
Ratings and Characteristics (Ta 25 ºC unless otherwise noted)
5.0 Amp. Glass Passivated Single Phase In Line Bridge Rectifier
VF, instantaneous forward voltage (V)
IF, instantaneous forward current (A)
IF (AV), average forward rectified current (A)
TYPICAL FORWARD CHARACTERISTIC
Tamb, ambient temperature (°C)
FORWARD CURRENT DERATING CURVE
0
1.0
10
0.1
0.6 1.0 1.40
5
3
2
1
0
0 50 100 150 17512525 75
MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
Number of cycles at 50 Hz.
200
150
100
50
0
10 1001
IFSM, peak forward surge current (A)
4
www.fagorelectronica.com
Document Name: d5xb Version: Nov-11
Page Number: 3/4
heatsink
Tc Tc
sine wave
R-load
on heatsink
+
-~~
Tamb = 25 °C
on glass-epoxi substrate
P. C . B.
soldering land 5 mm ø
sine wave
R-load
free in air
+
-~~
D5XB40 ........ D5XB100
Disclaimer
5.0 Amp. Glass Passivated Single Phase In Line Bridge Rectifier
www.fagorelectronica.com
Document Name: d5xb Version: Nov-11
Page Number: 4/4
All product, product specifications and data are subject to change without notice to improve reliability,
function or design or otherwise.
Fagor Electrónica, S.Coop., its affiliates, agents, and employees, and all persons acting on its or their
behalf (collectively, "Fagor"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained
in any datasheet or in any other disclosure relating to any product.
Fagor makes no warranty, representation or guarantee regarding the suitability of the products for any particular
purpose or the continuing production of any product. To the maximum extent permitted by applicable law,
Fagor disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all
liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied
warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Fagor's knowledge
of typical requirements that are often placed on Fagor products in generic applications. Such statements are not
binding statements about the suitability of products for a particular application. It is the customer's responsibility
to validate that a particular product with the properties described in the product specification is suitable for use in a
particular application. Parameters provided in datasheets and/or specifications may vary in different applications
and performance may vary over time. All operating parameters, including typical parameters, must be validated
for each customer application by the customer's technical experts. Product specifications do not expand or
otherwise modify Fagor's terms and conditions of purchase, including but nos limited to the warranty expressed
therein.
Except as expressly indicated in writing. Fagor products are not designed for use in medical, life-saving, or
life-sustaining applications or for any other application in which the failure of the Fagor product could result in
personal injury or death. Customers using or selling Fagor products not expressly indicated for use in such
applications do so at their own risk and agree to fully indemnify and hold Fagor and its distributors harmless from
and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use
or sale, including attomeys fees, even if such claim alleges that Fagor or its distributor was negligent regarding
the design or manufacture of the part. Please contact authorized Fagor personnel to obtain written terms and
conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Fagor, Product names and markings noted herein may be trademarks of their
respective owners.