G5Q PCB Power Relay A Miniature Power Relay with 1-pole 10A Switching Capacity * Compact single pole relay. * Excellent switching performance for a variety of loads. * Small, yet provide 8-kV impulse withstand voltage (between coil and contacts). RoHS Compliant Model Number Legend Application Examples G 5 Q -@ @ @ ------ 1 2 3 1. Number of Poles 1: 1-pole * Ideal for output applications of control equipments. 2. Contact Form None : SPDT (1c) A : SPST-NO (1a) 3. Enclosure rating None : Flux protection 4 : Fully-sealed G 5 Q Ordering Information Terminal Shape Classification Enclosure rating Contact form SPST-NO (1a) PCB terminals Flux protection Model G5Q-1A Standard SPDT (1c) G5Q-1 Fully-sealed Rated coil voltage 5 VDC 9 VDC 12 VDC 24 VDC 5 VDC 9 VDC 12 VDC 24 VDC Model G5Q-1A4 G5Q-14 Rated coil voltage 5 VDC 9 VDC 12 VDC 24 VDC 5 VDC 9 VDC 12 VDC 24 VDC Minimum packing unit 40 pcs/ tube Note. When ordering, add the rated coil voltage to the model number. Example: G5Q-1A 5 VDC Rated coil voltage Ratings Coil Contact form Rated voltage Rated current (mA) Coil resistance () Must operate voltage (V) Must release voltage (V) % of rated voltage 5 VDC 125 40 9 VDC 405 22.2 SPST-NO (1a) 12 VDC 720 16.7 24 VDC 2880 8.3 75% max. 5% min. 5 VDC 63 80 9 VDC 202 44.4 SPDT (1c) 12 VDC 360 33.3 24 VDC 1440 16.7 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. Note 2. The operating characteristics are measured at a coil temperature of 23C. Note 3. The "Max. voltage" is the maximum voltage that can be applied to the relay coil. Max. voltage (V) Power consumption (mW) Approx. 200 190% (at 23C) Approx. 400 Contacts Load Item SPST-NO (1a) Contact Type Single Contact material Ag-Alloy (Cd free) Rated load (resistive) Rated carry current Max. switching voltage Max. switching current 10 A at 125 VAC 3 A at 125 VAC 3 A at 250 VAC 5 A at 30 VDC Resistive load SPDT (1c) 10 A at 125 VAC (NO) 3 A at 125 VAC (NO) 3 A at 250 VAC (NO) 5 A at 30 VDC (NO) 3 A at 125 VAC (NC) 3 A at 250 VAC (NC) 3 A at 30 VDC (NC) 10 A (NO)/3 A (NC) 277 VAC, 30 VDC AC: 10 A (NO)/3 A (NC) DC: 5 A (NO)/3 A (NC) 1 G5Q PCB Power Relay Characteristics Item Classification 100 m max. Operate time 10 ms max. Release time 5 ms max. Insulation resistance *2 Dielectric strength 1,000 M min. Between coil and contacts 4,000 VAC, 50/60 Hz for 1 min Between contacts of the same polarity 1,000 VAC, 50/60 Hz for 1 min Impulse withstand voltage (between coil and contacts) 8 kV (1.2 x 50 s) Vibration resistance Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Shock resistance Destruction 1,000 m/s2 Malfunction 100 m/s2 Durability Mechanical 10,000,000 operations (18,000 operations per hour) Electrical * NO 50,000 operations: 10 A at 125 VAC resistive load (operation: ON for 1 sec, OFF for 3 sec) 200,000 operations: 3 A at 125 VAC resistive load (operation: ON for 1 sec, OFF for 1 sec) 100,000 operations: 3 A at 250 VAC resistive load (operation: ON for 1 sec, OFF for 1 sec) 100,000 operations: 5 A at 30 VDC resistive load (operation: ON for 1 sec, OFF for 1 sec) * NC 200,000 operations: 3 A at 125 VAC resistive load (operation: ON for 1 sec, OFF for 1 sec) 100,000 operations: 3 A at 250 VAC resistive load (operation: ON for 1 sec, OFF for 1 sec) 100,000 operations: 3 A at 30 VDC resistive load (operation: ON for 1 sec, OFF for 1 sec) Failure rate (P level) (reference *3) 10 mA at 5 VDC Ambient operating temperature -40C to 85C (with no icing or condensation) Ambient operating humidity 5% to 85% Weight Approx. 6.5 g Note. The data shown above are initial values. *1. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method. *2. Testing conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured. *3. This value was measured at a switching frequency of 120 operations/min. Engineering Data Ambient Temperature VS. Maximum Coil Voltage 100 AC resistive load (NO) 10 DC resistive load (NO) AC resistive load (NC) Maximum coil voltage (% of rated) Maximum Switching Capacity Switching current (A) G 5 Q Standard model Contact resistance *1 Shock Malfunction Y 200 1,000 180 160 X 1,000 140 Z 1,000 120 NC NO Contact 300 Contact 100 80 1,000 Z' 60 300 1,000 X' 40 DC resistive load (NC) 1 1 10 100 1000 Switching voltgate (V) 2 1,000 Y' 20 0 -40 -20 0 20 23 40 60 80 85 100 120 Ambient temperature (C) Unit: m/s2 Shock direction Sample: G5Q-14 12 VDC X X' Number of Relays: 5 pcs Y Test conditions: Shock is applied Z in X, Y, and Z directions three Z' times each with without energizing the Relays to check Y' the number of malfunctions. Requirement: None malfuction 100 m/s2 G5Q PCB Power Relay Dimensions (Unit: mm) G5Q-1A G5Q-1A4 PCB Mounting Holes (Bottom View) Tolerance: 0.1 mm 10.3MAX (10.0)* 20.3MAX (20.0)* . .1 (1.18) 3 -1. 0 dia Terminal Arrangement/ Internal Connections (Bottom View) 4 (1.19) 1 2 3 7.620.1 15.8MAX (15.5)* 5 (No coil polarity) 7.620.1 0.4 0.27 MAX 3.4 10.160.1 1 0.4 x 0.4 7.62 10.16 * Average value 7.62 G5Q-1 G5Q-14 PCB Mounting Holes (Bottom View) Tolerance: 0.1 mm 10.3MAX (10.0)* 20.3MAX (20.0)* (1.18) . . 5-1 0.1 3 (1.19) 15.8MAX (15.5)* d ia Terminal Arrangement/ Internal Connections (Bottom View) 1 2 3 7.620.1 5 0.4 0.27 MAX 3.4 0.4 x 0.4 2.540.1 1 5.08 (No coil polarity) 5.080.1 7.62 10.16 4 2.54 10.160.1 G 5 Q * Average value Approved Standards UL Recognized: CSA Certified: Model (File No. E41515) (File No. LR31928) Contact form Coil ratings Contact ratings 10 A 250 VAC N.O. only (Resistive) 40*C 10 A 30 VDC N.O. only (Resistive) 40*C G5Q SPST-NO (1a) SPDT (1c) 5 to 48 VDC 4 A 120 VAC N.O. only (Resistive) 40*C 3 A 250 VAC N.C. only (Resistive) 40*C 3 A 30 VDC N.C. only (Resistive) 40*C EC/IEC, VDE Number of test operations 6,000 100,000 6,000 (Certified/No.40009467) Model Contact form Coil ratings G5Q SPST-NO (1a) SPDT (1c) 5, 9, 12, 24 VDC Contact ratings 10 A 250 VAC (cos=1) (N.O.) 105*C 5 A 30 VDC (0 ms) (N.O.) 105*C 3 A 30 VDC (0 ms) (N.C.) 105*C Number of test operations 10,000 Precautions Please refer to "PCB Relays Common Precautions" for correct use. 3 G5Q PCB Power Relay G 5 Q * Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. * Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company 4 Contact: www.omron.com/ecb Cat. No. J155-E1-03 0812(0207)(O)