Proximity Sensor with All-stainless Housing E2FM CSM_E2FM_DS_E_3_1 Highly Durable Proximity Sensor for Tough Environments * Completely stainless-steel housing * Aluminum chip immunity * Embedding installation to metal (steel) fittings * Chemical resistance certified by Ecolab Europe * Lineup includes pre-wire models and DC 3-wire NPN output models with fluororesin coating. * Be sure to read Safety Precautions on page 9. * Excluding DC 3-wire M8 pre-wired models (E2FM-X1R5B@/-X1R5C@). Note: Models with a fluororesin coating also use vinyl chloride for the cable material and require separate protection. Features One-piece completely stainless-steel housing with a face thickness of 0.8 mm The face thickness is approximately 4 times that of previous models (E2ES) to enable sensing in even more severe conditions than ever. Brush Test 0.8 mm Continuous Impact Test Chemical and Detergent Proof The one-piece completely stainlesssteel housing of the sensing section withstands the following chemicals better. After 3 Minutes E2ES E2FM E2EQ (Spatter-resistant) The stainless-steel head means almost no wear when cleaned with a metal brush. The E2ES with a top wall thickness of 0.2 mm was penetrated after 10,000 impacts. E2FM The E2FM was not penetrated after 250,000 impacts (depth: 0.26 mm). * Sodium chloride * Gasoline * Dilute sodium hydroxide * Dilute hydrochloric acid * Mineral oil * Barium hydroxide Any many others Note: Cannot be used for explosion-proof applications. More than 20 times the durability of the E2ES! 1 E2FM Built-in Chip Immunity Chip immunity performance has been provided to greatly reduce false signals caused by spatter accumulation and other causes, almost eliminating the needs for cleaning, e.g., with metal brushes. Flush Mounting E2ES Not influenced by surrounding installation environment. Workpiece Workpiece Extension distance E2FM Note: When mounted in steel. Main Performance Comparison to Previous OMRON Products Face thickness E2FM 0.4 mm 0.8 mm 0.8 mm 0.8 mm M8 M12 M18 M30 Sensing distance E2ES ----0.2 mm 0.2 mm E2FM 1.5 mm 2.0 mm 5.0 mm 10.0 mm M8 M12 M18 M30 Response frequency E2ES ----4.0 mm 8.0 mm M8 M12 M18 M30 E2FM 200 Hz 100 Hz 100 Hz 50 Hz E2ES ----12 Hz 8 Hz Ambient operating temperature E2FM -25 to 70C E2ES 0 to 50C The chemical resistance has been certified by Ecolab Europe Ecolab GmbH & Co. OHG P.O. Box 13 04 06 D-40551 Dusseldorf This certificate is based on: documented test procedures (test no.: F&E/P3-E Nr. 40-1) according to material resistance defined product descriptions standardized cleaning procedure certifies that for OMRON Manufacturing of Germany GmbH Carl-Benz-Strasse 4 71154 Nufringen Test procedure Ecolab-test F&E Nr. 40-1 Dipping test: * Complete immersion in solutions/liquid Test period: * 14 days material resistance tests were performed with cleaning substances P3-topax 56, P3-topax 66, P3-topax 91 and demineralized water as a zero reference factor. The material resistance of the tested series Temperature: * room temperature (constant) Analysis: Visual judgement like swelling, brittleness, discoloring compared to zero-reference factor (demineralized water) Photometric documentation Product specifications: P3-topax 56: Acid foam cleaning substance for food and beverage industry P3-topax 66: Alkaline foam cleaning detergent with active chlorine for machine cleaning in food and beverage industry P3-topax 91: Neutral disinfection agent based on quaternary ammonium compounds (QAV) for the food industry Inductive Proximity Sensor E2FM to the P3 products used in the test can be considered to be positive according to the cleaning procedure mentioned overleaf. Cleaning plan for food and beverage industry* Rinsing with water 40 - 50C Rinsing with low pressure. Rinsing from top to bottom in the direction of the drains. Cleaning of the drains. Dusseldorf, 14th February 2006 Foaming from bottom to top alkaline: P3-topax 66 2 - 5 % acid: P3-topax 56 2 % temperature: cold up to 40C contact time: 15 min. recommended Ecolab GmbH & Co. OHG i.V. i. V. Thomas Tyborski Reimund Laaff daily on demand Rinsing with water 40 - 50C Rinsing from top to bottom with low pressure Spray disinfection P3-topax 91 1-2 %, 30 -60 minutes *short description 2 E2FM Ordering Information Sensors [Refer to Dimensions on page 10.] DC 2-Wire, Pre-wired Models Size Shielded Sensing distance M8 1.5 mm M12 2 mm M18 5 mm M30 Output Operation mode DC 2-Wire (polarity) NO Model E2FM-X1R5D1 2M * E2FM-X2D1 2M * E2FM-X5D1 2M * E2FM-X10D1 2M * 10 mm * Fluororesin-coated models are also available. The model numbers are E2FM-QX@D. The cable material, however, is vinyl chloride and requires separate protection. DC 2-wire Pre-wired Smartclick Connector Models Size Sensing distance M8 1.5 mm M12 2 mm Shielded M18 Output Polarity Pin allocations: 1-4 Operation mode Polarity Pin allocations: 1-4 E2FM-X2D1-M1TGJ 0.3M No polarity Pin allocations: 3-4 E2FM-X2D1-M1TGJ-T 0.3M NO Polarity Pin allocations: 1-4 5 mm M30 10 mm Model E2FM-X1R5D1-M1TGJ 0.3M E2FM-X5D1-M1TGJ 0.3M No polarity Pin allocations: 3-4 E2FM-X5D1-M1TGJ-T 0.3M Polarity Pin allocations: 1-4 E2FM-X10D1-M1TGJ 0.3M No polarity Pin allocations: 3-4 E2FM-X10D1-M1TGJ-T 0.3M DC 2-Wire, Pre-wired Connector Models Size Sensing distance M8 1.5 mm M12 2 mm Shielded M18 Output Polarity Pin allocations: 1-4 Operation mode Polarity Pin allocations: 1-4 Polarity Pin allocations: 1-4 M30 E2FM-X2D1-M1GJ 0.3M * No polarity Pin allocations: 3-4 5 mm 10 mm Model E2FM-X1R5D1-M1GJ 0.3M * E2FM-X2D1-M1GJ-T 0.3M * NO E2FM-X5D1-M1GJ 0.3M * No polarity Pin allocations: 3-4 E2FM-X5D1-M1GJ-T 0.3M * Polarity Pin allocations: 1-4 E2FM-X10D1-M1GJ 0.3M * No polarity Pin allocations: 3-4 E2FM-X10D1-M1GJ-T 0.3M * * Fluororesin-coated models are also available. The model numbers are E2FM-QX@D1-M1GJ@. The cable material, however, is vinyl chloride and requires separate protection. DC 3-Wire, Pre-wired Models Size Shielded Sensing distance Model M8 1.5 mm Output configuration: NPN NO E2FM-X1R5C1 2M M12 2 mm E2FM-X2C1 2M E2FM-X2B1 2M E2FM-X5C1 2M E2FM-X5B1 2M E2FM-X10C1 2M E2FM-X10B1 2M M18 5 mm M30 10 mm Output configuration: PNP NO E2FM-X1R5B1 2M DC 3-Wire, M12 Connector Models Size Shielded Sensing distance Model M8 1.5 mm Output configuration: NPN NO E2FM-X1R5C1-M1 M12 2 mm E2FM-X2C1-M1 M18 M30 5 mm 10 mm Output configuration: PNP NO E2FM-X1R5B1-M1 * E2FM-X2B1-M1 * E2FM-X5C1-M1 E2FM-X5B1-M1 * E2FM-X10C1-M1 E2FM-X10B1-M1 * * Fluororesin-coated models are also available. The model numbers are E2FM-QX@B1-M1. The cable material, however, is vinyl chloride and requires separate protection. 3 E2FM Accessories (Order Separately) Sensor I/O Connectors [Refer to XS2.] Appearance Cable length Straight Sensor I/O Connector model number 2m XS2F-D421-DD0 5m XS2F-D421-GD0 2m XS2F-D422-DD0 5m XS2F-D422-GD0 2m XS2F-D421-DA0-A 5m XS2F-D421-GA0-A 2m XS2F-D422-DA0-A 5m XS2F-D422-GA0-A 2m XS2F-D421-DC0-A 5m XS2F-D421-GC0-A 2m XS2F-D422-DC0-A 5m XS2F-D422-GC0-A Applicable Proximity Sensor model number E2FM-X@D1-M1GJ-T L-shape Straight E2FM-X@D1-M1GJ L-shape Straight L-shape E2FM-X@C1-M1 E2FM-X@B1-M1 Note: Refer to Introduction to Sensor I/O Connectors for details. Ratings and Specifications DC 2-Wire (E2FM-X@D@) Size M8 M12 M18 M30 Shielded Model E2FM-X1R5D1-@ E2FM-X2D1-@ E2FM-X5D1-@ E2FM-X10D1-@ Item M12 M18 M30 E2FM-X2D1 -M1GJ-T E2FM-X5D1 -M1GJ-T E2FM-X10D1 -M1GJ-T Shielded Sensing distance 1.5 mm10% 2 mm10% 5 mm10% 10 mm10% 2 mm10% 5 mm10% 10 mm10% Set distance 0 to 1.05 mm 0 to 1.4 mm 0 to 3.5 mm 0 to 7 mm 0 to 1.4 mm 0 to 3.5 mm 0 to 7 mm Differential travel 15% max. of sensing distance Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 7.) Standard sensing object Iron, 8 x 8 x 1 mm Iron, Iron, Iron, Iron, Iron, Iron, 12 x 12 x 1 mm 30 x 30 x 1 mm 54 x 54 x 1 mm 12 x 12 x 1 mm 30 x 30 x 1 mm 54 x 54 x 1 mm Response frequency *1 200 Hz 100 Hz Power supply voltage (operating voltage range) 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. Leakage current 0.8 mA max. Output configuration With polarity Control output 100 Hz Switching capacity 3 to 100 mA Residual voltage 3 V max. (Load current: 100 mA max., Cable length: 2 m) 50 Hz 100 Hz 100 Hz 50 Hz Without polarity 5 V max. (Load current: 100 mA max., Cable length: 2 m) Indicators Operation indicator (red LED), Setting/Operation indicator (green LED) Operation mode (with sensing object approaching) NO *2 Protection circuits Surge suppressor, Load short-circuit protection Ambient temperature range Operating/Storage: -25 to 70C (with no icing or condensation) Ambient humidity range Operating/Storage: 35% to 95% (with no condensation) Temperature influence 20% max. of sensing distance at 23C in the temperature range of -25 to 70C. Voltage influence 1% max. of sensing distance at rated voltage in the rated voltage 15% range 4 E2FM Size M8 M12 M18 Shielded M30 M18 M30 E2FM-X2D1 -M1GJ-T E2FM-X5D1 -M1GJ-T E2FM-X10D1 -M1GJ-T Shielded Model E2FM-X1R5D1-@ E2FM-X2D1-@ E2FM-X5D1-@ E2FM-X10D1-@ Item M12 Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 500 m/s2 10 times each in X, Y, and Z directions Degree of protection IEC 60529 IP67 Connection method Unmarked: Pre-wired Models (Standard cable length: 2 m) Models ending with -M1GJ-@: Pre-wired Connector Models (Standard cable length: 300 mm) Pre-wired Approx. 105 g Weight Models (2 m) (packed Pre-wired state) Connector Approx. 65 g Models Case Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions Approx. 190 g Approx. 215 g Approx. 295 g --- --- --- Approx. 85 g Approx. 110 g Approx. 190 g Approx. 85 g Approx. 110 g Approx. 190 g Stainless steel (SUS303) Sensing surStainless steel (SUS303) face Materials (thickness) (0.4 mm) Clamping nuts Stainless steel (SUS303) Cable PVC (flame retardant) Toothed washer Zinc-plated iron Accessories (0.8 mm) (0.8 mm) Instruction manual *1. The response frequency of the DC switching section is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. *2. NC (normally closed) models are also available. Contact your OMRON representative. 5 E2FM DC 3-Wire (E2FM-X@C@, E2FM-X@B@) Size M8 M12 E2FM-X1R5@ E2FM-X2@ Shielded Item M18 M30 E2FM-X5@ E2FM-X10@ Shielded Model Sensing distance 1.5 mm10% 2 mm10% 5 mm10% 10 mm10% Set distance 0 to 1.05 mm 0 to 1.4 mm 0 to 3.5 mm 0 to 7 mm Differential travel 15% max. of sensing distance Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 7.) Standard sensing object Iron, 8 x 8 x 1 mm Iron, 12 x 12 x 1 mm Iron, 30 x 30 x 1 mm Iron, 54 x 54 x 1 mm Response frequency *1 200 Hz 100 Hz 100 Hz 50 Hz Power supply voltage (operating voltage range) 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. Current consumption 10 mA max. Output configuration PNP open collector output Control output Switching ca200 mA max. pacity Residual voltage 2 V max. (Load current: 200 mA, Cable length: 2 m) Indicators Operation indicator (yellow LED) Operation mode (with sensing object approaching) C1 Models: NPN open collector, NO (normally open) *2 B1 Models: PNP open collector, NO (normally open) *2 Protection circuits Reversed power supply polarity protection, Surge suppressor, Load short-circuit protection, and Reversed output polarity protection (except the E2FM-X1R5B1-M1) Ambient temperature range Operating/Storage: -25 to 70C (with no icing or condensation) Ambient humidity range Operating/Storage: 35% to 95% (with no condensation) Temperature influence 20% max. of sensing distance at 23C in the temperature range of -25 to 70C. Voltage influence 1% max. of sensing distance in the rated voltage 15% range (using the sensing distance at the rated voltage as standard) Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance Destruction: 500 m/s2 10 times each in X, Y, and Z Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions directions Degree of protection IEC 60529 IP67 Connection method Unmarked: Pre-wired Models (Standard cable length: 2 m) Models ending with -M1: Connector Models Weight (packed state) Materials Pre-wired Models (2 m) --- Approx. 170 g Approx. 190 g Approx. 275 g Pre-wired Connector Models Approx. 45 g Approx. 55 g Approx. 75 g Approx. 160 g Case Stainless steel (SUS303) Sensing surface Stainless steel (SUS303) (thickness) (0.4 mm) Clamping nuts Stainless steel (SUS303) Toothed washer Zinc-plated iron Accessories (0.8 mm) Instruction manual *1. The response frequency of the DC switching section is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. *2. NC (normally closed) models are also available. Contact your OMRON representative. 6 E2FM Engineering Data (Typical) Influence of Sensing Object Size and Material E2FM-X@ E2FM-X1R5@ E2FM-X10@ 10 8 E2FM-X2@ 2.5 Distance X (mm) 12 Distance X (mm) Distance X (mm) Sensing Area 2.0 Iron 3.0 2.5 Iron 2.0 1.5 E2FM-X5@ 6 1.5 1.0 4 Stainless steel (SUS304) Brass E2FM-X2D@ E2FM-X1R5@ 0.5 2 Stainless steel (SUS304) Aluminum 1.0 Brass 0.5 Aluminum Copper 0 -25 -20 -15 -10 -5 0 5 10 15 20 25 Distance Y (mm) Copper 0.0 0.0 0 5 10 15 20 25 Side length of sensing object: d (mm) 0 5 10 15 20 25 30 35 Side length of sensing object: d (mm) Leakage Current E2FM-X@D1-M1GJ(-T) Leakage current (mA) E2FM-X10@ Distance X (mm) Distance X (mm) E2FM-X5@ 12 7 6 Iron 10 Iron 5 8 Stainless steel (SUS304) 4 6 3 Stainless steel (SUS304) 2 1.0 E2FM-X1R5D1-M1GJ 0.8 E2FM-X10D1-M1GJ(-T) 0.6 E2FM-X5D1-M1GJ(-T) 0.4 4 E2FM-X2D1-M1GJ(-T) Brass Brass 0.2 2 1 Aluminum Aluminum Copper 0 0 20 Copper 0 0 40 60 80 Side length of sensing object: d (mm) 10 20 30 40 50 60 70 80 90 Side length of sensing object: d (mm) 0.0 0 5 10 15 20 25 30 Power supply voltage (V) Residual Output Voltage E2FM-X@D1-M1GJ(-T) Residual output voltage (V) Residual output voltage (V) E2FM-X@C@/B@ 2 1.5 E2FM-X2@ E2FM-X5@ 1 E2FM-X10@ 5 4 E2FM-X@D1-M1GJ-T 3 E2FM-X@D1-@ 2 0.5 1 E2FM-X1R5@ 0 0 1 10 50 100 200 1,000 Load current (mA) 1 3 5 10 30 50 100 Load current (mA) 7 E2FM I/O Circuit Diagrams DC 2-Wire Models Operation mode Model Timing chart Output circuit 1 Set position E2FMX@D1-@ Non-sensing area Unstable sensing area Connector Pin Arrangement Load 12 to 24 VDC Proximity sensor main circuit Stable sensing area Proximity sensor 4 0V Sensing object Note: The load can be connected to either the +V or 0 V side. (%) NO 100 Rated sensing distance 70 (TYP) Note: Pins 2 and 3 are not used. 0 Setting indicator (green) ON OFF OFF ON Control output OFF Connector Pin Arrangement Load 12 to 24 VDC (0 V) Proximity sensor main circuit Operation indicator (red) ON E2FMX@D1M1GJ-T 4 3 Note: Pins 1 and 2 are not used. Note 1. The load can be connected to either the +V or 0 V side. 2. The E2FM-X@@1-M1GJ-T has no polarity. There is no need to be concerned about the polarity of pins 3 and 4. 0 V (12 to 24 VDC) DC 3-Wire Models Operation mode Output configuration Model E2FMX1R5C@ E2FMNPN open- X2C@ collector E2FMmodel X5C@ E2FMX10C@ Timing chart Output circuit Brown +V Load Sensing area Non-sensing area Proximity sensor Connector Pin Arrangement * Black Sensing object Blue Note: For Connector Models, the connection between pins 1, 4 and 3 uses an NO contact, and the connection between pins 1, 2 and 3 * There is no reversed output polarity protection diode. uses an NC contact. 0V (%) 100 0 NO E2FMX1R5B@ E2FMPNP open- X2B@ collector E2FMmodel X5B@ E2FMX10B@ Proximity sensor main circuit Rated sensing distance Brown DC12 to 24VDC Operation indicator OFF (yellow) ON ON OFF Proximity sensor main circuit * Connector Pin Arrangement Black Control output Load Note: For Connector Models, the connection between pins 1, 4 and 3 uses an NO contact, and the connection between pins 1, 2 and 3 * There is no reversed output polarity protection diode. uses an NC contact. Blue 0V 8 E2FM Safety Precautions (Unit: mm) WARNING Item This product is not designed or rated for ensuring safety of persons. Do not use it for such purposes. Model E2FM-X1R5@ Never use this product with an AC power supply. Otherwise, explosion may result. E2FM-X2@ Precautions for Safe Use E2FM-X5@ The following precautions must be observed to ensure safe operation. 1. Do not use the Sensor in an environment where inflammable or explosive gas is present. 2. Do not attempt to disassemble, repair, or modify any Sensors. 3. Power Supply Voltage Do not use a voltage that exceeds the rated operating voltage range. Applying a voltage that is higher than the operating voltage range may result in explosion or fire. 4. Incorrect Wiring Be sure that the power supply polarity and other wiring is correct. Incorrect wiring may cause explosion or fire. 5. Connection without a Load If the power supply is connected directly without a load, the internal elements may explode or burn. Be sure to insert a load when connecting the power supply. E2FM-X10@ Embedding material l d D m n Iron 0 8 0 4.5 30 Aluminum 10 50 10 4.5 50 Iron 0 12 0 8 40 Aluminum 16 70 16 8 70 Iron 0 18 0 20 60 Aluminum 16 80 16 20 80 Iron 0 30 0 40 100 Aluminum 24 120 24 40 120 Note: The influence from other non-magnetic surrounding metals is nearly the same as that from aluminum. Mutual Interference When installing two or more Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained. (Unit: mm) Model A B E2FM-X1R5@ Item 35 30 E2FM-X2@ 40 35 Precautions for Correct Use E2FM-X5@ 65 60 Do not use the Sensor under ambient conditions that exceed the ratings. 1. Do not use the Sensor in the following locations. (1) Outdoor locations directly subject to sunlight, rain, snow, or water droplets (2) Locations subject to atmospheres with chemical vapors, in particular solvents and acids (3) Locations subject to corrosive gas 2. The Sensor may malfunction if used near ultrasonic cleaning equipment, high-frequency equipment, transceivers, cellular phones, inverters, or other devices that generate a high-frequency electric field. Refer to the Technical Guide Photoelectric Sensors for typical measures. 3. Laying the Sensor wiring in the same conduit or duct as highvoltage wires or power lines may result in incorrect operation and damage due to induction. Wire the Sensor using a separate conduit or independent conduit. 4. Cleaning Never use thinner or other solvents. Otherwise, the Sensor surface may be dissolved. E2FM-X10@ 110 100 A B Chips from Cutting Aluminum Normally, chips from cutting aluminum or cast iron will not cause a detection signal to be output even if it adheres to or accumulates on the detection surface. In the following cases, however, a detection signal may be output. Remove the cutting chips in these cases. 2 1. If d 3 D at the center of the detection surface where d is the cutting chip size and D is the detection surface size Model Dimension (mm) E2FM-X1R5@ E2FM-X2@ E2FM-X5@ E2FM-X10@ Cutting chip D Detection surface D 6 10 16 28 2. If the cutting chips are pressed down Design Influence of Surrounding Metal d Pressed down Cutting chips When the Proximity Sensor is embedded in metal, make sure that the clearances given in the following table are maintained. The values depend on the type of nuts used for mounting. Be sure to use the supplied nuts (SUS303). Mounting d dia. n m D l l Do not tighten the nut with excessive force. A washer must be used with the nut. Do not use tightening force that exceeds the values in the following table. Model E2FM-X1R5@ E2FM-X2@ E2FM-X5@ E2FM-X10@ Torque 9 N*m 30 N*m 70 N*m 180 N*m 9 E2FM (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Sensors Pre-wired Models E2FM-X1R5@ E2FM-X2@ 53 49 39 30 25 15 dia. 4 5 Two clamping nuts M8 x 1 13 4-dia. vinyl-insulated round cable (flame retardant), Standard length; 2 m * Operation indicators 33 6-dia. vinyl-insulated round cable (flame retardant), Standard length; 2 m * Two clamping Operation indicators nuts M12 x 1 17 Toothed washer 7 4 21 dia. Toothed washer * 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.4 mm) 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.2 mm) * 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.75 mm) 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.75 mm) E2FM-X10@ E2FM-X5@ 63.5 49 43 42 dia. 56 10 5 42 36 10 4 29 dia. 6-dia. vinyl-insulated round cable (flame retardant), Standard length; 2 m * 6-dia. vinyl-insulated round cable (flame retardant), Standard length; 2 m * 24 Two clamping Operation indicators nuts M18 x 1 36 Operation indicators M30 x 1.5 Two clamping nuts Toothed washer Toothed washer * 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.75 mm) 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.75 mm) * 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.75 mm) 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.75 mm) Pre-wired Connector Models E2FM-X1R5D@-M1GJ-@ E2FM-X2D@-M1GJ-@ 53 49 30 25 15 dia. 13 M12 x 1 4 21 dia. 5 Two clamping nuts Indicator *2 M8 x 1 39 33 *1 17 Toothed washer 4 M12 x 1 7 Two clamping nuts Indicator *2 M12 x 1 Toothed washer *1. 4-dia. vinyl-insulated round cable (flame retardant), Standard length; 300 mm *2. Operation indicator (red/green) Setting indicator (green) E2FM-X5D@-M1GJ-@ *1 *1. 6-dia. vinyl-insulated round cable (flame retardant), Standard length; 300 mm *2. Operation indicator (red/green) Setting indicator (green) E2FM-X10D@-M1GJ-@ 63.5 49 43 56 42 36 29 dia. 24 4 M18 x 1 42 dia. 10 5 10 M12 x 1 M12 x 1 Two clamping nuts Toothed washer Indicator *2 *1 *1. 6-dia. vinyl-insulated round cable (flame retardant), Standard length; 300 mm *2. Operation indicator (red/green) Setting indicator (green) 36 M30 x 1.5 Two clamping nuts Toothed washer *1 Indicator *2 *1. 6-dia. vinyl-insulated round cable (flame retardant), Standard length; 300 mm *2. Operation indicator (red/green) Setting indicator (green) 10 E2FM M12 Connector Models E2FM-X1R5@@-M1 E2FM-X2@@-M1 53 53.5 39 34.5 33 30 25 4 15 dia. 13 21 dia. 7 4 5 M8 x 1 Toothed washer Two clamping M12 x 1 nuts Four operation indicators (yellow) 17 Two clamping nuts M12 x 1 E2FM-X5@@-M1 M12 x 1 Four operation indicators (yellow) Toothed washer E2FM-X10@@-M1 63.5 49 56 43 42 36 29 dia. 4 42 dia. 10 5 10 M12 x 1 24 M18 x 1 Two clamping nuts Toothed washer M12 x 1 Four operation indicators (yellow) 36 M30 x 1.5 Two clamping nuts Four operation indicators (yellow) Toothed washer Mounting Hole Dimensions Dimension F (mm) M8 8.5 +0.5 dia. 0 M12 12.5 +0.5 dia. 0 M18 18.5 +0.5 dia. 0 M30 30.5 +0.5 dia. 0 F 11 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2008.11 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2008 All Right Reserved.