Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 6502GE Multi-Conductor - Commercial Applications For more Information please call 1-800-Belden1 General Description: Security & Alarm Cable, Plenum-CMP, 1-22 AWG stranded bare copper pair with Flamarrest(R) insulation and Beldfoil(R) shield, 2-22 AWG stranded bare copper condcutors with insulation, Overall Flamarrest(R) jacket with ripcord Physical Characteristics (Overall) Conductor AWG: # Conductors # Pairs AWG Stranding Conductor Material 2 1 22 7 BC - Bare Copper Total Number of Conductors: 4 Insulation Insulation Material: Insulation Trade Name Insulation Material Flamarrest(R) Wall Thickness (in.) LS PVC - Low Smoke Polyvinyl Chloride 0.009 Inner Shield Inner Shield Material: Inner Shield Trade Name Type Inner Shield Material Beldfoil(R) Coverage (%) Tape Aluminum Foil-Polyester Tape 100.000 Inner Shield Drain Wire AWG: AWG 24 Inner Shield Drain Wire Stranding: 7 Inner Shield Drain Wire Conductor Material: TC - Tinned Copper Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Flamarrest(R) Nom. Wall Thickness (in.) LS PVC - Low Smoke Polyvinyl Chloride .015 Outer Jacket Ripcord: Yes Overall Cable Overall Cabling Color Code Chart: Color Black and Red (shielded pair) White Green Overall Nominal Diameter: 0.180 in. Pair Pair Lay Length & Direction: Lay Length (in.) Twists (twist/ft) 1.500 8.000 Mechanical Characteristics (Overall) Bulk Cable Weight: 19.300 lbs/1000 ft. Max. Recommended Pulling Tension: 42 lbs. Min. Bend Radius/Minor Axis: 1.800 in. Page 1 of 3 09-11-2017 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 6502GE Multi-Conductor - Commercial Applications Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMP CEC/C(UL) Specification: CMP EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: NFPA 262 C(UL) Flame Test: FT6 Plenum/Non-Plenum Plenum (Y/N): Yes Non-Plenum Number: 5502GE Electrical Characteristics (Overall) Nom. Inductance: Inductance (H/ft) .17 Nom. Capacitance Conductor to Conductor: Capacitance (pF/ft) 55 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/ft) 99 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/1000 ft) 16.4 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 2.2 Amps per conductor @ 25C Put Ups and Colors: Item # Putup Ship Weight Color 6502GE 008U1000 1,000 FT 21.000 LB GRAY Notes Item Desc 1 FSPR + 2 CDR #22 FLRST FLRST 6502GE 009C100 100 FT 1.900 LB WHITE 1 FSPR + 2 CDR #22 FLRST FLRST 6502GE 009U1000 1,000 FT 21.000 LB WHITE 1 FSPR + 2 CDR #22 FLRST FLRST 6502GE 009U250 250 FT 6.000 LB WHITE 1 FSPR + 2 CDR #22 FLRST FLRST 6502GE 010C100 100 FT 1.700 LB BLACK 1 FSPR + 2 CDR #22 FLRST FLRST 6502GE 010U1000 1,000 FT 21.000 LB BLACK 1 FSPR + 2 CDR #22 FLRST FLRST 6502GE 010U250 250 FT 6.000 LB BLACK 1 FSPR + 2 CDR #22 FLRST FLRST 6502GE 877U1000 1,000 FT 21.000 LB NATURAL 6502GE 8771000 1,000 FT 21.000 LB NATURAL 1FSPR+2CDR#22 FLRSTFLRST C 1FSPR+2CDR#22 FLRSTFLRST Notes: C = CRATE REEL PUT-UP. Page 2 of 3 09-11-2017 Detailed Specifications & Technical Data ENGLISH MEASUREMENT VERSION 6502GE Multi-Conductor - Commercial Applications Revision Number: 1 Revision Date: 02-27-2015 (c) 2017 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 2014/35/EU). Page 3 of 3 09-11-2017 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Belden Wire & Cable: 6502GE 877U1000 6502GE 8771000 6502GE 008U1000 6502GE 009U1000 6502GE 010U1000