PpSsPp- 5- 50000s esrei er ise s 500W with PFC and Parallel Function 5 0 0 W w i t h P F C and Parallel Function SPECIFICATION MODEL OUTPUT PSP-500-5 PSP-500-12 PSP-500-13.5 PSP-500-15 PSP-500-24 PSP-500-27 PSP-500-48 DC VOLTAGE 5V 12V 13.5V 15V 24V 27V 48V RATED CURRENT 80A 41.5A 37A 33A 20.8A 18.5A 10.5A CURRENT RANGE 0 ~ 80A 0 ~ 41.5A 0 ~ 37A 0 ~ 33A 0 ~ 20.8A 0 ~ 18.5A 0 ~ 10.5A RATED POWER 400W 498W 499.5W 495W 499.2W 499.5W 504W RIPPLE & NOISE (max.) Note.2 100mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p VOLTAGE ADJ. RANGE 10 ~ 13.2V 1.0% 12 ~ 15V 1.0% 13.5 ~ 18V 1.0% 20 ~ 26.4V 1.0% 24 ~ 30V 1.0% 41 ~ 56V 1.0% 4.75 ~ 5.5V VOLTAGE TOLERANCE Note.3 2.0% LINE REGULATION 0.5% 0.3% 0.3% 0.3% 0.2% 0.2% 0.2% LOAD REGULATION 2.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 1500ms, 50ms at full load SETUP, RISE TIME 24ms at full load HOLD TIME (Typ.) VOLTAGE RANGE INPUT Note.6 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) 0.95/230VAC EFFICIENCY (Typ.) 76% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 7A/115AVC 20A/115VAC 0.98/100VAC at full load 82% 82% 82% 84% 84% <1mA / 240VAC OVER LOAD 110 ~ 125% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed OVER TEMPERATURE REMOTE CONTROL WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 86% 3.5A/230VAC 40A/230VAC LEAKAGE CURRENT PROTECTION OVER VOLTAGE FUNCTION 127 ~ 370VDC 5.75 ~ 6.75V 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V 27.6 ~ 32.4V 31 ~ 36.5V 57.6 ~ 67.2V Protection type : Shut down o/p voltage, re-power on to recover RTH2 95 Detect on heatsink of Q1,Q7 power transistor & L3 output choke Protection type : Shut down o/p voltage, recovers automatically after temperature goes down RC+/RC-: 0 ~ 0.8V=power on ; 4 ~ 10V=power off sink current <4 ~ 10mA -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH with 30CFM forced air non-condensing -20 ~ +85 0.03%/ , 10 ~ 95% RH (0 ~ 50 VIBRATION SAFETY STANDARDS 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B EMC (Note 4) HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS DIMENSION PACKING NOTE Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A 130.1K hrs min. MIL-HDBK-217F (25 278*129*63.5mm (L*W*H) 2.6Kg; 6pcs/15.7Kg/0.89CUFT ) FileName:PSP-500-SPEC2005-09-13 WWW.ASTRODYNE.COM 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 PpSsPp--550000 s se er irei se s 5 0 0 W w i t h P F C500W and with Parallel Function PFC and Parallel Function Mechanical Specification Case No. 919A 220 Unit:mm 16 127 113 7 5 30 20 4-M3 4-M3 4-M3 O/P 13 7 5 240 251 278 LED ADJ. CONTROL 34.5 20 63.5 4-M3 240 51 62 73 84 7 1 2 3 10 I/P 10 1 2 3 4 5 6 113 127 Air flow direction BOTTOM VIEW 15 220 TOP VIEW AC Input Terminal Pin. No. Assignment Pin No. 1 2 3 Assignment AC/L AC/N FG DC Output Terminal Pin. No Assignment Pin No. 1~3 4~6 Control Pin. No Assignment : MOLEX 5559-NP uses 5558 male crimp terminal Pin No. Assignment Pin No. Assignment Mating connector Terminal 1 5 P(Current share) NC MOLEX 5556 2 6 -S PF(Power fail signal) MOLEX 5557-NR Female crimp Terminal G +S 3 7 receptacle RCRC+ 4 8 Assignment DC OUTPUT +V DC OUTPUT -V Derating Curve Output Derating VS Input Voltage 12 ~ 48V 100 100 90 80 80 70 5V LOAD(%) LOAD (%) 60 40 20 -10 0 10 20 30 40 AMBIENT TEMPERATURE ( 50 ) 60 60 50 40 90 115 135 180 230 264 INPUT VOLTAGE (V) 60Hz FileName:PSP-500-SPEC2005-09-13 WWW.ASTRODYNE.COM 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 PpSsPp--550000 sseer irei es s 5 0 0 W w i t h P F C500W and with Parallel Function PFC and Parallel Function Control terminal instruction manual PF G +5V RC- RC+ RC- RC+ RC- RC+ G +S G +S G -S PF -S PF -S PF P NC P NC P NC -V -V -V +V +V -V -V -V -V +V LOAD + +V LOAD + +V +V LOAD + +V +V +V Remote Sensing Power Fail Signal DC 0~15V -V -V POWER SIGNAL +S Remote Control Power ON: When V RC+ , RC- =0 ~ 0.8V or Open Power OFF: When V RC+ , RC- =4 ~ 10V PF Signal is the voltage difference between "G" and "PF" pin output Parallel Operation RC- RC+ -V RC- RC+ RC- RC+ G +S G +S G -S PF -S PF -S PF P NC P NC P NC -V -V -V -V -V -V -V -V +V +V +V +V +V +V +V +V +V +S LOAD + Parallel Operation With Remote Sensing RC- RC+ -V -V RC- RC+ RC- RC+ G +S G +S G -S PF -S PF -S PF P NC P NC P NC -V -V -V -V -V -V -V +V +V +V +V +V +V +V +V +V +S DC 0~15V LOAD + Parallel Operation With Remote Control WWW.ASTRODYNE.COM 300 Myles StandishFileName:PSP-500-SPEC2005-09-13 Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181