IBEK 3 Watt DC-DC-Converter Family IPS3
www.ibek.ch
15.12.2008 More power with IBEK!Page 6
Single, double, dual & triple outputs
Input to output isolated
Dual & triple outputs: Output1 to output2(3) isolated
Ultra wide 1:4 input voltage ranges
Shutdown input
Very high efficiency up to 83%
High reliability
Continuous no-load and short-circuit proof
Extended ambient temperature range -40…+85‚C
No derating
Made in Switzerland, accordingly ISO 9001:2000
2 yearswarranty
Electromagnetic emission EN 55022 < BStandard Types 2Input voltage Output 1Output 2
Conducted and radiated emissions VDC VDC mA VDC mA
(Triple outputs upon request) Single output
xx IPS3-05-T RoHS 4.75…16 5500 - -
5 IPS 24 IPS 48 IPS xx IPS3-12-T RoHS (nominal 5) 12 250 - -
No load input current 25 5 3 mA typ. xx IPS3-15-T RoHS 15 200 - -
Input current in shutdown condition 1.3 mA typ. Double output 39…36
Switching frequency 130 kHz typ. xx IPS3-0505-T RoHS (nominal 24) 5250 - -
Output voltage accuracy 2% max. xx IPS3-1212-T RoHS 12 125 - -
Static line regulation 15 mV typ. xx IPS3-1515-T RoHS 15 100 - -
Static load regulation FL to L0…2%; 5 VDC outputs 0…5% typ. Dual output
45 V for 10 ms
repetition rate 10 s
Output voltage noise (20 MHz BW) 100 mVpp typ. xx IPS3-05-05-T RoHS 18…75 5250 5250
Efficiency 79% to 83% typ. xx IPS3-05-12-T RoHS (nominal 48) 5250 12 125
I/O Electric strength test voltage 1500 VDC xx IPS3-05-15-T RoHS 5250 15 100
O/O Electric strength test voltage 700 VDC xx IPS3-12-12-T RoHS 12 125 12 125
Coupling capacitance 300 pF xx IPS3-15-15-T RoHS 15 100 15 100
Shutdown input (SD) Triple output 4
xx IPS3-05-1212-T RoHS 5300 12 62
Apply -0.3…+1.35 VDC / 100…200 A 1to
shut down (switch off) the output voltage(s).
Normal operation with open pin. xx IPS3-05-1515-T RoHS 5300 15 50
Ambient temperature range -T: -25…+71ƒC; -S: -40…+85ƒC
Case temperature range -T: -25…+95ƒC; -S: -40…+105ƒC
Storage temperature range -T: -55…+105ƒC; -S: -55…+105ƒC
Case material Non-conductive plastic, UL94 V-0 rated
2.200.000 hours
MTBF, GB @ 40ƒC case
(MIL-HDBK-217F, Notice 2)
15 IPS3-types: -0.3…+0.6 VDC / 500…700 A
2To complete type number replace "xx" by the required nominal input
voltage, e.g. 5 IPS3-05-12-T RoHS.
3 Double outputs should have symmetrical load conditions to comply
with the specifications listed on the left side.
4Not available with input voltage range 4.75…16 VDC.
Extended temperature range -S is available for all types.
Replace -T by -S on type number, e.g. 24 IPS3-05-1515-S RoHS.
Modifications and customs are available upon request.
Pin Configuration
Pin Single
output
Double
output
Dual
output
Triple
output
1+Vi +Vi +Vi +Vi
2+Vi +Vi +Vi +Vi
9No Pin No Pin -Go1 No Pin
10 No Pin Go No Pin Go1
11 No Pin Go No Pin No Pin
12 -Go No Pin +Vo1 Vo1
13 +Vo -Vo +Vo2 +Vo2
15 No Pin +Vo No Pin Go2
16 No Pin No Pin -Go2 No Pin
17 No Pin No Pin No Pin -Vo2
20 SD SD SD SD
23 -Gi -Gi -Gi -Gi
Dimensions in mm (inches)
24 -Gi -Gi -Gi -Gi
Specifications subject to change without notice