High efficiency topology, 92% typical at 5V
Industry standard footprint
Wide operating temperature, -40˚C to +85˚C (natural convection)
80% to 110% output trim
No minimum load
Overvoltage and overtemperature protection
Remote on/off
Remote sense
Approvals to EN60950 and UL/cUL1950
Complies with ETS 300 019-1-3/2-3
Complies with ETS 300 132-2 input voltage and current requirements
Complies with ETS 300 386-1
The EXB30 is a new high efficiency single
output open frame isolated 30 Watt
converter series in an industry standard
footprint. The first five models in the series
feature a 2:1 input voltage range of 36 to
75VDC and are available in output voltages
of 12V, 5V, 3.3V, 2.5V and 2V. The output
voltage is trimmable from 80 to 110%
except the 12V model which has a wider
trim range of 60 to 110%. The sub 5V
models have an output current rating of 8A.
Typical efficiencies for the models are 92%
for the 5V, 90% for the 3.3V and 12V, 88%
for the 2.5V and 87% for the 2V version.
The EXB30 series offers remote on/off and
remote sense compensation to correct for
voltage drops at the load. Overcurrent,
overvoltage and overtemperature protection
features are included as standard.
With full international safety approval
including EN60950 and cUL1950, the
EXB30 reduces compliance costs and time
to market.
The series complies with ETS 300 386-1
EMC requirements, ETS 300 132-2
concerning the power supply interface at
the input to telecommunications equipment
and ETS 300 019-1-3 concerning
environmental conditions. The EXB30 single
is primarily targeted at the networking,
telecom and wireless markets.
EXB30 48V SERIES
Single output
EXB30 Series | 30W
DC/DC
Isolated DC/DC converters
1
[ 2 YEAR WARRANTY ]
Absolute Maximum Ratings
Input Characteristics
Turn On/Off
SXA10 Series | 1
0W DC/DC
EXB30 Series | 30W
DC/DC
Isolated DC/DC converters
2
Characteristic Symbol Min Typ Max Units Notes and Conditions
Input voltage - turn on Vin (on) 33.8 36 VDC
Input voltage - turn off Vin (off) 29.9 31.7 VDC
Hysteresis 2.1 VDC
Tur n on delay - enabled, Tdelay 30 50 msec With the enable signal asserted,
then power applied (power) this is the time from when the
input voltage reaches the
minimum specified operating
voltage until the output voltage
is within the total regulation
band
Tur n on delay - power Tdelay 30 50 msec Vin = Vin (nom), then enabled.
applied, then enabled (enable) This is the time taken until the
output voltage is within the total
error band
Rise time Trise - 25 45 msec From 10% to 90%; full resistive
load, no external capacitance
Characteristic Symbol Min Typ Max Units Notes and Conditions
Input voltage - operating Vin (oper) 36 48 75 VDC
Input current - no load lin 50 mADC Vin (min) - Vin (max), enabled
Input current - Quiescent lin (off) 2 5 mADC Converter disabled
Input voltage rise/fall time dv/dt 5 V/ms As per ETS300 132 Part 4.4
Inrush current (i2t or peak) linrush 0.003 A2s As per ETS300 132 Part 4.7 with
recommended LISN
Input ripple rejection 60 - dB Frequency <1 kHz
Input fuse 2 A Slow blow/anti-surge, HRC
recommended, 200 V rated
Stresses in excess of the maximum ratings can cause permanent damage to the device. Operation of the device is not implied at these or any
other conditions in excess of those given in the specification. Exposure to absolute maximum ratings can adversely affect device reliability.
All specifications are typical at nominal input Vin = 48V, full load under any resistive load combination at 25˚C unless otherwise specified.
Characteristic Symbol Min Typ Max Units Notes and Conditions
Input voltage - continuous Vin (cont) -0.3 80 VDC Vin(+) - Vin(-)
Input voltage - peak/surge Vin (peak) -0.3 100 VDC 2s max. non repetitive
or standard/level
Input voltage remote pin Vrem (peak) -0.3 75 VDC Peaks of any duration
Operating temperature Top -40 +120 ˚C Measured at thermal reference
points, see Note 1
Storage temperature Tstorage -40 +125 ˚C
Ambient temperature Tambient -40 +85 ˚C See Note 6 and Figure 1
EXB30 Series | 30W
DC/DC
Isolated DC/DC converters
3www.artesyn.com
Signal Electrical Interface
Common Protection/Control
Reliability and Service Life
Isolation
Characteristic Symbol Min Typ Max Units Notes and Conditions
Input to output test voltage 1500 VDC Test duration 1s
Input to output capacitance 2200 pF
Input to output resistance 100 MMeasured with 500 VDC
Input to output insulation Basic
system
Characteristic Symbol Min Typ Max Units Notes and Conditions
Mean time between failure MTBF 300,000 Hours MIL-HDBK-217F,
Vin = Vin (nom); Iout = Iout
(max); ambient 25˚C;
ground benign environment
Mean time between failure MTBF TBD Hours Demonstrated
Characteristic Symbol Min Typ Max Units Notes and Conditions
Overtemperature shutdown Tots 125 ˚C PCB temperature at SRs,
threshold (singles) non-latching shutdown
protection
Overtemperature shutdown - - 5 - ˚C
- restart hysteresis
Remote sense compensation 10 % Compensation includes trim
Characteristic - Signal Name Symbol Min Typ Max Units Notes and Conditions
At remote/control ON/OFF pin See Notes 2 and 3
Control pin open circuit voltage Vih 3 4 5 V Iih = 0µA; open circuit voltage
High level input voltage Vih 2 V Converter guaranteed on
when control pin is
greater than Vih (min)
High level input current Iih 10 µA Current flowing into control pin
when pin is pulled high
(max. at Vih = 75V)
Acceptable high level Iih (leakage) -50 µA Acceptable leakage current from
leakage current signal pin into the open collector
driver (neg = from converter)
Low level input voltage ViI 0 1.2 V Converter guaranteed off
when control pin is
less than Vil (max)
Low level input current IiI -100 µA Vil = 0.4 V
Low level input current Iil (max) -100 µA ViI = 0.0 V; maximum source
current from converter with
short circuit
SXA10 Series | 1
0W DC/DC
EXB30 Series | 30W
DC/DC
Isolated DC/DC converters
4
Other Specifications
Characteristic Symbol Min Typ Max Units Notes and Conditions
Switching frequency Fsw - 300 - kHz Fixed frequency
Weight - 40 g
Environmental Requirements
EMC
Electromagnetic Compatibility
Referenced ETSI standards:
ETS 300 019: Environmental conditions and environmental tests for telecommunications equipment
ETS 300 019: Part 1-3 (1997) Classification of environmental conditions stationary use at weather protected locations
ETS 300 019: Part 2-3 (1997) Specification of environmental tests stationary use at weather protected locations
Phenomenon Port Standard Test level Criteria Notes and conditions
Immunity:
ESD Enclosure EN61000-4-2 6kV cont NP As per ETS 300 386-1 table 5
8kV air NP
8kV cont RP
15kV air RP
EFT DC Power EN61000-4-4 2kV NP As per ETS 300 386-1 table 5
4kV LFS
Signal EN61000-4-4 1kV NP As per ETS 300 386-1 table 5
2kVr LFS
Radiated field Enclosure EN61000-4-3 10V/m NP As per ETS 300 386-1 table 5
Conducted DC power EN61000-4-6 10V NP As per ETS 300 386-1 table 5
Signal EN61000-4-6 10V NP
Input transients DC power ETS 300 132, ETR 283
Characteristic Symbol Min Typ Max Units Notes and Conditions
Thermal performance -40 +85 ˚C See Notes 1, 5 and
Figures 1, 2 and 8
Altitude 3,000 m Derate total max. output
9,864 ft current by 20%
10,000 m Derate total max. output
32,821 ft current by 50%
Characteristic Parameter Reference Test Level Notes and Conditions
Air temperature Low IEC 68-2-1 -40˚C
All characteristics and parameters
High IEC 68-2-2 +70˚C extracted from ETS 300 019
Change IEC 68-2-14 -40˚C to +70˚C classes 3.1, 3.2, 3.3, 3.4 and 3.5
Relative humidity Low - 10%
High IEC 68-2-56 100%
Condensation IEC 68-2-30 90 to 100%
Vibration IEC class 3M5 Displacement IEC 68-2-6 5-9Hz 5mm/s
Acceleration IEC 68-2-6 9-200Hz 1g
MIL-STD-202F Method 204D cond. A
Shocks IEC class 3M5 Acceleration IEC 68-2-29 10g
MIL-STD-202F Method 213B cond. A
Model Input Output Overvoltage Output Current Typical Max. Load
Number Voltage Voltage Protection (Max.) Efficiency Regulation
EXB30-48S05 36-75 VDC 5.0V 5.65 6A 92% ±0.2%
EXB30-48S3V3 36-75 VDC 3.3V 3.80 8A 90% ±0.2%
EXB30-48S2V5 36-75 VDC 2.5V 3.0 8A 88% ±0.2%
EXB30-48S2V0 36-75 VDC 2.0V 2.3 8A 87% ±0.2%
EXB30-48S12 36-75 VDC 12.0V 14.2 3A 90% ±0.2%
EXB30 Series | 30W
DC/DC
Isolated DC/DC converters
5www.artesyn.com
EMC
Electromagnetic Compatibility
Phenomenon Port Standard Test level Criteria Notes and conditions
Emission:
Conducted DC power EN55022 Level A See recommended external filter for
compliance bandwidth 20 kHz to 30 MHz,
as per ETS 300 386-1
EN55022 Level B See recommended external filter for
compliance bandwidth 20 kHz to 30 MHz,
as per ETS 300 386-1
Signal EN55022 Level B Bandwidth 150kHz to 30MHz,
as per ETS 300 386-1
Radiated EN55022 Level B Bandwidth 30 MHz to 1 GHz, as per
ETS 300 386-1, with Cu ground plane
Material Ratings
Model Numbers
Safety Agency Approvals
Characteristic
UL/cUL 1950 File Number E136005
VDE File Number 10401-3336-0157/31HJK
VDE License Number Approval number pending
Standards Compliance List
Standard Category
EN60950
UL/cUL1950 3rd edition
VDE EN60950 (VDE0805) : 1997 + A11
Characteristic - Signal Name Notes and Conditions
Flammability rating UL94V-0
Material type FR4 PCB
Performance criteria:
NP: Normal Performance: EUT shall withstand applied test and operate within relevant limits as specified without damage.
RP: Reduced Performance: EUT shall withstand applied test. Reduced performance is permitted within specified limits, resumption to
normal performance shall occur at the cessation of the test.
LFS: Loss of Function (self recovery): EUT shall withstand applied test without damage, temporary loss of function permitted during test.
Unit will self recover to normal performance after test.
Referenced ETSI standards:
ETS 300 386-1 table 5 (1997): Public telecommunication network equipment, EMC requirements
ETS 300 132-2 (1996): Power supply interface at the input to telecommunication equipment: Part 2 operated by direct current (DC)
ETR 283 (1997): Transient voltages at interface A on telecommunications direct current (DC) power distributions
SXA10 Series | 1
0W DC/DC
EXB30 Series | 30W
DC/DC
Isolated DC/DC converters
6
Input Characteristics
EXB30-48S05 Model
Electrical Characteristics - O/P
EXB30-48S05 Model
Characteristic Symbol Min Typ Max Units Notes and Conditions
Nominal set-point voltage Vout (nom) 4.925 5.00 5.075 VDC Vin = Vin (Nom);
Iout = Iout (nom); T = 25˚C
Total regulation band Vout 4.85 - 5.15 VDC For all line, static load and
temperature until end of life.
Line regulation - 0.05 0.10 % Vin (min) - Vin (max)
Load regulation - 0.10 0.20 % Iout (min) - Iout (max)
Temperature regulation - 0.01 0.02 ±%/˚C Vin = Vin (Nom),
Iout = Iout (nom)
Output current continuous Iout 0.00 6.00 ADC
Output current - short circuit Isc 11.00 A RMS Continuous, unit auto recovers
from short, Vout < 100mV
Output voltage - noise Vp-p 80 150 mV pk-pk Measurement bandwidth 20 MHz
Vrms 10 20 mV RMS Measurement bandwidth 20 MHz
See Application Note for Set-up
Characteristic Symbol Min Typ Max Units Notes and Conditions
Input current - operating Iin 0.68 0.69 ADC Vin = Vin (nom); Iout = Iout
(max.); Vo = Vo (nom)
Input current - maximum Iin (max.) 0.91 0.92 ADC Vin = Vin (min); Iout = Iout
(max.); Vo = nom
Reflected ripple current Iin (ripple) 10 mA RMS Iout - Iout (max.), measured with
Class A filter. See Apps Note
Reflected ripple current Iin (ripple) 5 mA pk-pk Iout - Iout (max.), measured with
Class A filter. See Apps Note
Input capacitance - internal Cinput 1.5 µF Internal to converter
filter (ceramic)
EXB30 Series | 30W
DC/DC
7www.artesyn.com
Isolated DC/DC converters
Protection and Control Features
EXB30-48S05 Model
Efficiency
EXB30-48S05 Model
Characteristic Symbol Min Typ Max Units Notes and Conditions
Overvoltage clamp voltage Vov 5.55 5.65 6.50 VDC Non-latching.
Refer to Application Note
Overcurrent limit inception Ioc 7.5 ADC Vout = 90% of Vout (nom)
Output voltage trim range 10 % Trim up
20 % Trim down
Open sense voltage 5.65 VDC
Characteristic Symbol Min Typ Max Units Notes and Conditions
Efficiency η91.0 92.0 % Iout = 100% Iout (max),
Vin = Vin (nom)
Efficiency η89.5 90.5 % Iout = 50% Iout (max),
Vin = Vin (nom)
Electrical Characteristics - O/P
EXB30-48S05 Model
Characteristic Symbol Min Typ Max Units Notes and Conditions
Load transient response - Vdynamic 2.0 % Peak deviation for 50% to 75%
peak deviation step load, di/dt = 100 mA/µsec
Load transient response - Trecovery 300 µsec Settling time to within 1% of
recovery output set point voltage for 50%
to 75% step load
External load capacitance Cext 0 10,000 µF Operation with more than the
max. value is possible, but
please consult Artesyn before
doing so
SXA10 Series | 1
0W DC/DC
EXB30 Series | 30W
DC/DC
Isolated DC/DC converters
8
Input Characteristics
EXB30-48S3V3 Model
Electrical Characteristics - O/P
EXB30-48S3V3 Model
Characteristic Symbol Min Typ Max Units Notes and Conditions
Input current - operating Iin 0.61 0.62 ADC Vin = Vin (nom); Iout = Iout
(max.); Vo = Vo (nom)
Input current - maximum Iin (max.) 0.82 0.83 ADC Vin = Vin (min); Iout = Iout
(max.); Vo = nom
Reflected ripple current Iin (ripple) 10 mA RMS Iout - Iout (max.), measured with
Class A filter. See Apps Note
Reflected ripple current Iin (ripple) 35 mA pk-pk Iout - Iout (max.), measured with
Class A filter. See Apps Note
Input capacitance - internal Cinput 1.5 µF Internal to converter
filter (ceramic)
Characteristic Symbol Min Typ Max Units Notes and Conditions
Nominal set-point voltage Vout (nom) 3.25 3.30 3.35 VDC Vin = Vin (Nom);
Iout = Iout (nom); T = 25˚C
Total regulation band Vout 3.20 3.40 VDC For all line, static load and
temperature until end of life
Line regulation 0.05 0.10 % Vin (min) - Vin (max)
Load regulation 0.10 0.20 % Iout (min) - Iout (max)
Temperature regulation 0.01 0.02 ±%/˚C Vin = Vin (nom), Iout = Iout (nom)
Output current continuous Iout 0 8.00 ADC
Output current - short circuit Isc 13.00 A RMS Continuous, unit auto recovers
from short, Vout < 100mV
Output voltage - noise Vp-p 100 150 mV pk-pk Measurement bandwidth:
20 MHz; See Application Note
for measurement set-up details
Vrms 10 20 mV RMS Measurement bandwidth 20 MHz
See Application Note for set-up
EXB30 Series | 30W
DC/DC
9www.artesyn.com
Isolated DC/DC converters
Protection and Control Features
EXB30-48S3V3 Model
Efficiency
EXB30-48S3V3 Model
Characteristic Symbol Min Typ Max Units Notes and Conditions
Overvoltage clamp voltage Vov 3.66 3.80 4.29 VDC Non-latching
Refer to Application Note
Overcurrent limit inception Ioc 9.2 ADC Vout = 90% of Vout (nom)
Output voltage trim range 10 % Trim up
20 % Trim down
Open sense voltage 3.8 VDC
Characteristic Symbol Min Typ Max Units Notes and Conditions
Efficiency η88.5 90.0 % Iout = 100% Iout (max),
Vin = Vin (nom)
Efficiency η87.0 88.0 % Iout = 50% Iout (max),
Vin = Vin (nom)
Electrical Characteristics - O/P
EXB30-48S3V3 Model
Characteristic Symbol Min Typ Max Units Notes and Conditions
Load transient response - Vdynamic 2.0 % Peak deviation for 50% to 75%
peak deviation step load, di/dt = 100 mA/µsec
Load transient response - Trecovery 300 µsec Settling time to within 1% of
recovery output set point voltage for 50%
to 75% step load
External load capacitance Cext 0 10,000 µF Operation with more than the
maximum value is possible, but
please consult Artesyn before
doing so
SXA10 Series | 1
0W DC/DC
EXB30 Series | 30W
DC/DC
Isolated DC/DC converters
10
Input Characteristics
EXB30-48S2V5 Model
Electrical Characteristics - O/P
EXB30-48S2V5 Model
Characteristic Symbol Min Typ Max Units Notes and Conditions
Nominal set-point voltage Vout (nom.) 2.462 2.50 2.537 VDC Vin = Vin (Nom);
Iout = Iout (nom); T = 25˚C
Total regulation band Vout 2.425 2.575 VDC For all line, static load and
temperature until end of life
Line regulation 0.05 0.10 % Vin (nom) - Vin (max)
Load regulation (all models) 0.10 0.20 % Iout (min) - Iout (max)
Temperature regulation 0.01 0.02 ±%/˚C Vin = Vin (nom), Iout = Iout (nom)
(all models)
Output current continuous Iout 0.00 8.00 ADC
Output current - short circuit Isc 13.0 A RMS Continuous, unit auto recovers
from short, Vout < 100mV
Output voltage - noise Vp-p 80 150 mV pk-pk Measurement bandwidth 20 MHz
Vrms 12 20 mV RMS Measurement bandwidth 20 MHz
See Application Note for set-up
Characteristic Symbol Min Typ Max Units Notes and Conditions
Input current - operating Iin 0.48 0.485 ADC Vin = Vin (nom);
Iout = Iout (max.); Vo = Vo (nom)
Input current - maximum Iin (max.) 0.635 0.64 ADC Vin = Vin (min);
Iout = Iout (max.); Vo = nom
Reflected ripple current Iin (ripple) 10 mA RMS Iout - Iout (max.), measured with
Class A filter. See Apps Note
Reflected ripple current Iin (ripple) 35 mA pk-pk Iout - Iout (max.), measured with
Class A filter. See Apps Note
Input capacitance - internal Cinput 1.5 µF Internal to converter (ceramic)
filter
EXB30 Series | 30W
DC/DC
11 www.artesyn.com
Protection and Control Features
EXB30-48S2V5 Model
Efficiency
EXB30-48S2V5 Model
Isolated DC/DC converters
Characteristic Symbol Min Typ Max Units Notes and Conditions
Efficiency η87.0 88.0 % Iout = 100% Iout (max),
Vin = Vin (nom)
Efficiency η86.0 87.2 % Iout = 50% Iout (max),
Vin = Vin (nom)
Electrical Characteristics - O/P
EXB30-48S2V5 Model
Characteristic Symbol Min Typ Max Units Notes and Conditions
Load transient response - Vdynamic 5 % Peak deviation for 50% to 75%
peak deviation step load, di/dt = 100 mA/µsec
Load transient response - Trecovery 300 µsec Settling time to within 1% of
recovery output set point voltage for 50%
to 75% step load
External load capacitance Cext 0 10,000 µF Operation with more than the
max. value is possible, but
please consult Artesyn before
doing so
Characteristic Symbol Min Typ Max Units Notes and Conditions
Overvoltage clamp voltage Vov 2.78 2.90 3.25 VDC Non-latching
Refer to Application Note
Overcurrent limit inception Ioc 9.2 ADC Vout = 90% of Vout (nom)
Output voltage trim range 10 % Trim up
20 % Trim down
Open sense voltage 2.9 VDC
SXA10 Series | 1
0W DC/DC
EXB30 Series | 30W
DC/DC
Isolated DC/DC converters
112
Input Characteristics
EXB30-48S2V0 Model
Electrical Characteristics - O/P
EXB30-48S2V0 Model
Characteristic Symbol Min Typ Max Units Notes and Conditions
Input current - operating Iin 0.39 0.40 ADC Vin = Vin (nom);
Iout = Iout (max.);
Vo = Vo (nom)
Input current - maximum Iin (max.) 0.52 0.53 ADC Vin = Vin (min);
Iout = Iout (max.);
Vo = nom
Reflected ripple current Iin (ripple) 10 mA RMS Iout - Iout (max.), measured with
Class A filter. See Apps Note
Reflected ripple current Iin (ripple) 35 mA pk-pk Iout - Iout (max.), measured with
Class A filter. See Apps Note
Input capacitance - internal Cinput 1.5 µF Internal to converter (ceramic)
filter
Characteristic Symbol Min Typ Max Units Notes and Conditions
Nominal set-point voltage Vout 1.97 2.00 2.03 VDC Vin = Vin (Nom);
Iout = Iout (nom); T = 25˚C
Total regulation band Vout (1) 1.94 2.06 VDC For all line, static load and
temperature until end of life.
Does not include cross
regulation
Line regulation Vout 0.05 0.10 % Iout = Iout (nom);
Vin (min) to Vin (max);
Load regulation Vout 0.10 0.20 % Vin = Vin (nom),
Iout (min) to Iout (max)
Temperature regulation 0.01 0.02 ±%/˚C Vin = Vin (nom), Iout = Iout (nom)
Output current continuous Iout 0.00 8.00 ADC
EXB30 Series | 30W
DC/DC
13 www.artesyn.com
Isolated DC/DC converters
Protection and Control Features
EXB30-48S2V0 Model
Efficiency
EXB30-48S2V0 Model
Characteristic Symbol Min Typ Max Units Notes and Conditions
Efficiency η85.5 86.5 % Iout = 100% Iout (max),
Vin = Vin (nom)
Efficiency η84.5 85.5 % Iout = 50% Iout (max),
Vin = Vin (nom)
Electrical Characteristics - O/P
EXB30-48S2V0 Model
Characteristic Symbol Min Typ Max Units Notes and Conditions
Output current - short circuit Isc 13.0 A RMS Continuous, unit auto recovers
from short, Vout = 100mV
Output voltage - noise Vp-p 80 150 mV pk-pk
Measurement bandwidth: 20 MHz
See application Note for set-up
Vrms 12 20 mV RMS
Measurement bandwidth: 20 MHz
Load transient response - Vdynamic 5.0 % Peak deviation for 50% to 75%
peak deviation Step load, di/dt = 100 mA/µsec
Load transient response - Trecovery 300 µsec Settling time to within 1% of
recovery output set point voltage for
50% to 75% step load
External load capacitance Cext 0 10,000 µF Operation with more than the
max. value is possible, but
please consult Artesyn before
doing so. Unit spec. compliant
with no external output
capacitance
Characteristic Symbol Min Typ Max Units Notes and Conditions
Overvoltage clamp voltage Vov 2.22 2.3 2.60 VDC Non-latching, refer to
Application Note
Overcurrent limit inception Ioc 9.2 ADC Vout = 90% of Vout (nom),
Output voltage trim range 10 % Trim up
20 % Trim down
Open sense voltage 2.3 VDC
SXA10 Series | 1
0W DC/DC
EXB30 Series | 30W
DC/DC
Isolated DC/DC converters
Input Characteristics
EXB30-48S12 Model
Electrical Characteristics - O/P
EXB30-48S12 Model
Characteristic Symbol Min Typ Max Units Notes and Conditions
Nominal set-point voltage Vout (nom) 11.82 12.00 12.18 VDC Vin = Vin (Nom);
Iout = Iout (nom); T = 25˚C
Total regulation band Vout 11.64 - 12.36 VDC For all line, static load and
temperature until end of life.
Line regulation - 0.05 0.10 % Vin (min) - Vin (max)
Load regulation - 0.10 0.20 % Iout (min) - Iout (max)
Temperature regulation - 0.01 0.02 ±%/˚C Vin = Vin (Nom),
Iout = Iout (nom)
Output current continuous Iout 0.00 3.00 ADC
Output current - short circuit Isc 5.00 A RMS Continuous, unit auto recovers
from short, Vout < 100mV
Output voltage - noise Vp-p 80 150 mV pk-pk Measurement bandwidth 20 MHz
Vrms 10 20 mV RMS Measurement bandwidth 20 MHz
See Application Note for Set-up
Characteristic Symbol Min Typ Max Units Notes and Conditions
Input current - operating Iin 0.84 0.86 ADC Vin = Vin (nom); Iout = Iout
(max.); Vo = Vo (nom)
Input current - maximum Iin (max.) 1.12 1.14 ADC Vin = Vin (min); Iout = Iout
(max.); Vo = nom
Reflected ripple current Iin (ripple) 10 mA RMS Iout - Iout (max.), measured with
Class A filter. See App Note
Reflected ripple current Iin (ripple) 5 mA pk-pk Iout - Iout (max.), measured with
Class A filter. See App Note
Input capacitance - internal Cinput 1.5 µF Internal to converter
filter (ceramic)
114
EXB30 Series | 30W
DC/DC
Isolated DC/DC converters
Protection and Control Features
EXB30-48S12 Model
Efficiency
EXB30-48S12 Model
Characteristic Symbol Min Typ Max Units Notes and Conditions
Overvoltage clamp voltage Vov VDC Non-latching.
Refer to Application Note
Overcurrent limit inception Ioc 3.5 ADC Vout = 90% of Vout (nom)
Output voltage trim range 10 % Trim up
40 % Trim down
Open sense voltage 12.63 VDC
Characteristic Symbol Min Typ Max Units Notes and Conditions
Efficiency η89.0 90.0 % Iout = 100% Iout (max),
Vin = Vin (nom)
Efficiency η89.0 90.0 % Iout = 50% Iout (max),
Vin = Vin (nom)
Electrical Characteristics - O/P
EXB30-48S12 Model
Characteristic Symbol Min Typ Max Units Notes and Conditions
Load transient response - Vdynamic 2.0 % Peak deviation for 50% to 75%
peak deviation step load, di/dt = 100 mA/µsec
Load transient response - Trecovery 300 µsec Settling time to within 1% of
recovery output set point voltage for 50%
to 75% step load
External load capacitance Cext 0 2,000 µF Operation with more than the
max. value is possible, but
please consult Artesyn before
doing so
15 www.artesyn.com
SXA10 Series | 1
0W DC/DC
EXB30 Series | 30W
DC/DC
Isolated DC/DC converters
16
Figure 1: Derating Curve Output Current vs Temperature S3V3
Natural Convection (<0.1m/s airflow) for S05, S3V3, S2V5 and
S2V0 models
Figure 2: Typical Efficiency vs Vin Figure 3: Typical Efficiency vs Ambient Temperature
Figure 4: Typical Power-up Characteristic S05
(Ch1 : Input V, Ch2 : Vout), Vin = 48V, Load = 6A
Figure 5: Control On/Off Characteristic S05
(Ch1 : Vout, Ch2 : Control), Vin = 48V, Load = 6A
-40˚C
0%
20%
40%
60%
80%
100%
Ambient Temperature
Rated Output Current
-20˚C 20˚C 40˚C 60˚C 80˚C 100˚C
85˚C
Efficiency Vs. Vin
Efficiency
75%
77%
79%
81%
83%
85%
87%
89%
91%
93%
36V 40V 45V 50V 55V 60V 65V 70V 75V
48S2V0
48S2V5
48S3V3
48S05
Efficiency Vs. Temperature
Efficiency
75%
77%
79%
81%
83%
85%
87%
89%
91%
93%
-35˚C -25˚C -15˚C-5˚C5˚C15˚C25˚C35˚C45˚C55˚C65˚C75˚C85˚C
2V0
2V5
3V3
5V
Figure 1B: Derating Curve Output Current vs Temperature
Natural Convection (<0.1m/s airflow) for S12 model
100% (3A)
-40°C
0%
80°C90°C
Rated Output Current
Ambient Temperature
Natural Convection (<0.1 m/s)
50% (1.5A)
83% (2.5A)
85°C
EXB30 Series | 30W
DC/DC
Isolated DC/DC converters
17 www.artesyn.com
Figure 7.1: Typical Ripple and Noise S05 on
Test Card at Nominal Conditions
Figure 6.3: Typical Transient Response of S2V5
(Ch1 : Vout, Ch2 : Iout), Vin = 48V, Iout = 4A to 6A Figure 6.4: Typical Transient Response of S2V0
(Ch1 : Vout, Ch2 : Iout), Vin = 48V, Iout = 4A to 6A
Figure 6.1: Typical Transient Response of S05
(Ch1 : Iout, Ch2 : Vout), Vin = 48V, Iout = 3A to 4.5A Figure 6.2: Typical Transient Response of S3V3
(Ch1 : Vout, Ch2 : Iout), Vin = 48V, Iout = 4A to 6A
Figure 6.5: Typical Transient Response on S12
(Ch1 : Vout, Ch2 : Iout) Vin = 48V, Iout = 1.5A to 2.25A
SXA10 Series | 1
0W DC/DC
EXB30 Series | 30W
DC/DC
Isolated DC/DC converters
18
Figure 8A: Hot Spot Locations on S05, S3V3, S2V5 and S2V0
Figure 7.4: Typical Ripple and Noise S2V0 on
Test Card at Nominal Conditions
Figure 8B: Hot Spot Locations on S12
Figure 7.5 Typical Ripple and Noise on S12 on Test Card at
Nominal Conditions
Figure 7.3: Typical Ripple and Noise S2V5 on
Test Card at Nominal Conditions
Figure 7.2: Typical Ripple and Noise S3V3 on
Test Card at Nominal Conditions
EXB30 Series | 30W
DC/DC
Isolated DC/DC converters
19 www.artesyn.com
Figure 9: Dimensions and Pinout
0.43 ±0.02
(10.90 ±0.5)
0.138 ±0.02
(3.50±0.5)
0.02
(0.50)
0.20
(5.08)
2.00
(50.80)
1.40
(35.56)
1.00
(25.40)
0.40
(10.16)
0.70
(17.78)
1.00
(25.40)
1.40
(35.56)
2.40 ±0.02
(60.96 ±0.5)
1.90
(48.26) 0.19
(4.83)
2.28 ±0.02
(57.91 ±0.5)
ALL DIMENSIONS IN INCHES (mm)
General Tolerance ±0.010 (0.25)
(unless otherwise specified)
0.50
(12.70)
OPEN-FRAME
HEIGHT
ø0.040 ±0.002
(ø1.02 ± 0.05)
STAND-OFFS
4 PLACES
BOTTOM
VIEW
1
3
4
9
5
6
7
8
Pin Connections
Pin No. Function
1 Vin -
2 No Pin
3 Remote On/Off
4 Vin +
5Vo +
6 Vsense +
7Trim
8 Vsense -
9Vo -
Note 1
Hot spot temperature is defined as the highest temperature
measured at any one of the specified temperature hotspot
checkpoints. See Figure 8: Hotspot temperature check points.
Note 2
The control pin is referenced to Vin-.
Note 3
The EXB30 is supplied as standard with active high logic.
Control input pulled low: unit disabled.
Control input floating: unit enabled.
The unit can be supplied with active low logic.
Note 4
The outputs of these converters should not be connected in
parallel.
Note 5
Thermal reference set up: Unit mounted centrally on a 200mm x
240 mm testboard. Testboard is mounted vertically in a fully
enclosed 300mm x 300mm x 300mm testbox. Ambient
temperature measur ed at the bottom of the textbox. Altitude sea
level.
Note 6
12V model is rated at 30W and 36W for maximum ambient
temperatures of 85˚C and 80˚C respectively.
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is accessible only to trained personnel. The user
must provide the recommended fusing in order to comply with
safety approvals.
EXB30 Series | 30W
DC/DC
Isolated DC/DC converters
20
DS_EXB30S48_20020115.PDF
Data Sheet Artesyn Technologies® 2002
The information and specifications contained in this data sheet are
believed to be correct at time of publication. However, Artesyn
Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to
change without notice. No rights under any patent accompany the
sale of any such product(s) or information contained herein.
EXB30 Series | 30W
DC/DC