HBD DC-DC Series Data Sheet 30 to 60-Watt, Dual Output Description HBD dual output, dc-dc converters feature high efficiency, 1500 VDC isolation, and open-frame packaging. The HBD family allows board designers to deliver any combination of power from either output, up to each model's maximum rating. The HBD is available in 5V/3.3V or 3.3V/2.5V combinations in either a 24 V or 48 V input version. The HBD uses planar magnetics and has an MTBF of over a million hours. Features * Standard configurations are RoHS compliant with Pb solder exemption (2) * Independent dual outputs * Flexible load sharing * High efficiency topology * Open-frame design * Planar magnetics * Independent trim for each output * 1500 V Isolation * 100 C baseplate operation Efficiency vs. Load (24V Input) 85 80 75 Technical Specifications HBD060YGE-A Input Voltage Range 24 VDC Nominal 48 VDC Nominal Reflected Ripple Input Reverse Voltage Protection 70 18.00 - 36.00 VDC 34.00 - 75.00 VDC 80 mA Shunt Diode EFF. (18V) EFF. (24V) 65 EFF. (36V) 60 10 20 30 40 50 60 70 80 90 100 LOAD % Output Load Regulation Iout Min. - Iout Max., Vin Nom., Output2 Minimum Output Current Dynamic Regulation, Loadstep Pk Deviation Settling Time Voltage Trim Range (5V/3.3V Units) Power Limit Threshold Range, % of Iout Rated OVP Trip Range (Main Ouput) Efficiency vs. Load (48V Input) 1% 0.2% Vout 1.0% Vout 0.5% Vout 1.0% Vout 10% Iout Rated 25% Iout 4% Vout 500 s 10% 110 - 140% 115 - 140% Vout Nom. 85 80 75 EFFICIENCY % Setpoint Accuracy Line Regulation Vin Min. - Vin Max., Iout Rated, Output 1 Line Regulation Vin Min. - Vin Max., Iout Rated, Output 2 Load Regulation Iout Min. - Iout Max., Vin Nom., Output 1 70 HBD060ZGE-A 65 60 HBD040ZGE-A 55 HBD0X0ZED-A 50 10 20 30 40 50 60 70 80 90 100 LOAD % General Turn-On Time Remote Shutdown Switching Frequency Isolation Input - Output Input - Case Output - Case Temperature Coefficient Case Temperature Operating Range Storage Range Thermal Shutdown Range Humidity Max., Non-Condensing Vibration, 3 Axes, 5 Min Each MTBF (Bellcore TR-NWT-000332) Safety Weight (approx.) REV. FEB 03, 2006 10 ms Positive Logic 500 kHz 1500 VDC 1050 VDC 500 VDC 0.03%/C -40 To +100 C -40 To +125 C 105 To 115 C 95% 5g 6 1.3 x 10 Hrs UL, cUL, VDE 2.4 oz Page 1 of 3 Notes (1) For negative logic, add suffix "N" to model number. (2) The solder exemption is for customers choosing to use the exemptions for lead in solders for servers, storage and storage array systems, and network infrastructure equipment for switching, signaling, transmission, and network management for telecommunications. MTBF predictions may vary slightly from model to model. Specifications typically at 25 C, normal line, and full load, unless otherwise stated. Soldering Conditions: I/O pins, 260 C, ten seconds; fully compatible with commercial wave-soldering equipment. Safety: Agency approvals may vary from model to model. Please consult factory for specific model information. Units are water-washable and fully compatible with commercial spray or immersion post wave-solder washing equipment. www.power-one.com HBD DC-DC Series Data Sheet 30 to 60-Watt, Dual Output Model Selection MODEL INPUT VOLTAGE (VOLTS) INPUT VOLTAGE RANGE (VOLTS) MAXIMUM INPUT CURRENT (AMPS)* OUTPUT VOLTAGE (VOLTS) 24 24 24 48 48 48 48 18-36 18-36 18-36 34-75 34-75 34-75 34-75 2.89 4.54 3.02 1.50 1.51 1.62 2.27 3.3/2.5 5.0/3.3 5.0/3.3 3.3/2.5 5.0/3.3 3.3/2.5 5.0/3.3 HBD040YED-A HBD060YGE-A HBD040YGE-A HBD030ZED-A HBD040ZGE-A HBD040ZED-A HBD060ZGE-A NOTES: * ** *** && RATED OUTPUT CURRENT (AMPS)&& 12/15 12/15 8/12 9/12*** 8/12 12/15 12/15 RIPPLE & NOISE pk-pk (mV) TYPICAL EFFICIENCY** 75/75 100/75 100/75 75/75 100/75 75/75 75/75 75% 78% 80% 75% 80% 75% 75% Maximum input current at minimum input voltage, maximum rated output power. At nominal Vin, rated output. Total output power to be restricted to 30 Watts. Current can be drawn from either output to its maximum value, or from both outputs to a combined total of 15A. Model numbers highlighted in yellow or shaded are not recommended for new designs. Mechanical Drawing 0.18" (4.6mm) 2.28" (57.9mm) MOUNTING INSERTS M3X.5 THROUGH 4PL 1.700"(43.2mm) 1.400"(35.6mm) 1 1.000"(25.4mm) 2 BOTTOM VIEW (PIN SIDE) 0.400"(10.2mm) 5 1.500"(38.1mm) 6 1.200"(30.5mm) 7 0.900"(22.9mm) DIA 0.040" (1.0mm) 2.40" (61.0mm) 8 0.500"(12.7mm) 9 0.200"(5.1mm) 10 -0.100"(-2.5mm) 3 0 4 -0.300"(-7.6mm) -0.50"(-12.7mm) -0.19" (-4.8mm) 0 .025" REF. (0.6mm) 1.900" (48.3mm) 0.50" (12.7mm) SIDE VIEW Thermal Impedance Natural Convection 100 LFM 200 LFM 300 LFM 400 LFM 6.6 C/W 5.7 C/W 4.2 C/W 3.1 C/W 2.6 C/W Note: Thermal impedance data is dependent on many environmental factors. The exact thermal performance should be validated for specific application. REV. FEB 03, 2006 Pin Function 1 -Vin 2 3 4 Case On/Off +Vin 5 +Vout 2 6 - Vout 2 7 8 9 Trim 2 +Vout 1 -Vout 1 10 Trim 1 Page 2 of 3 Tolerances Inches: .XX 0.020 .XXX 0.010 Pin: 0.002 (Millimeters) .X 0.5 .XX 0.25 0.05 (Dimensions as listed unless otherwise specified.) www.power-one.com OPTIONS Ordering Information Suffix Code Identification: Series Applicability: HAS, HBD, HBS, HES, QBS, QES, TES, TQD Features & Options Descriptions Suffix Code Remote ON/OFF Positive Logic Negative Logic None N Trim Standard Power-One (Negative) Industry-standard (Positive) None T Pin Length 0.18" (4.6mm), standard model length None 0.145" (3.68mm) 7 0.110" (2.8mm) 8 Special Options Customer-specific models S# NOTE: Contact factory for availability of specific options. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. REV. FEB 03, 2006 Page 3 of 3 www.power-one.com