Automotive brushless DC fans Climate control for commercial vehicles The engineer's choice Version 2012-09 Automotive brushless DC fans Our automotive brushless DC (BL-DC) axial fans and BL-DC dual centrifugal blowers set the trend in commercial vehicle climate control. They not only fulfil today's increased expectations for comfort, for example in buses, they also work without wear - because they are brushless - for over 40,000 hours. No extra maintenance, no additional service required. That is the reliability you expect from ebm-papst. Advantages and characteristics in a glance - Over 40,000 operating hours - Continuous speed control - High efficiency - Low noise emission due to aerodynamically optimised impellers - Increased reliability due to high integration density of the electronics - Can be retrofitted to existing systems - Meet the highest EMC requirements - Control characteristic can be parameterised - Optimised voltage independence - Extended temperature range - Durable ball bearings 2 Table of contents GreenTech: The Green Company 4 Ideas for technological change in commercial vehicles 6 EC dual centrifugal blowers with brushless DC motor 9 "Premium" EC dual centrifugal blowers with brushless DC motor 19 "Basic" EC axial fans with brushless DC motor 25 EC centrifugal fans - RadiCal, backward curved 43 Accessories 50 - Temperature control module, temperature sensor - Connection leads Electrical connections 53 Technical parameters & scope 58 ebm-papst representatives & subsidiaries 62 3 Sustainability is at the Centre of Our Thoughts and Actions. Out of Conviction! Eco-friendliness and sustainability have always been at the core of our thoughts and actions. For decades, we have worked according to the simple but strict creed of our co-founder Gerhard Sturm: "Each new product we develop has to be better than the last one in terms of economy and ecology." GreenTech is the ultimate expression of our corporate philosophy. GreenTech is pro-active development. GreenTech is acknowledged and certified. Even in the design phase, the materials and processes we use are optimi- Every step in our chain of production meets the stringent standards of sed for the greatest possible eco-friendliness, energy balance and - environmental specialists and the public. The 2008 Environmental Prize wherever possible - recyclability. We continually improve the material of Baden-Wuerttemberg, the Green Award 2009, the Energy Efficiency and performance of our products, as well as the flow and noise charac- Award 2009 of the dena - to give just a few examples - testify to this. teristics. At the same time, we significantly reduce energy consumption. The environmental advantage gained in the performance of the products Close cooperation with universities and scientific institutes and the pro- developed from our GreenTech philosophy can also be measured in the fessorship we endow in the area of power engineering and regenerative fulfilment of the most stringent energy and environmental standards. energies allows us to profit from the latest research findings in these In many instances, our products are already well below the thresholds fields - and at the same time ensure highly qualified young academics. energy legislation will impose a few years from now - several times over. GreenTech is ecofriendly production. Our customers profit from this every day. GreenTech also stands for maximum energy efficiency in our production The heart of GreenTech is future-oriented EC technology from ebm- processes. There, the intelligent use of industrial waste heat and ground- papst. The EC technology at the core of our most efficient motors and water cooling, photovoltaics and, of course, our own cooling and venti - fans allows efficiency of up to 90%, saves energy at a very high level, lation technology are of the utmost importance. Our most modern plant, significantly extends service life and makes our products maintenance- for instance, consumes 91% less energy than currently specified and free. These values pay off not only for the environment, but every cent al- required. In this way, our products contribute to protecting the environ- so pays off for the user! All ebm-papst products - even those for which ment, from their origin to their recyclable packaging. GreenTech EC technology does not (yet) make sense from an application viewpoint - feature the greatest possible connection of economy and ecology. 5 Ideas for technological change in commercial vehicles EC dual centrifugal blowers: for maximum performance with the smallest installation space; easy to control and extremely quiet. A comfortable environment in commercial vehicles is by no means just a matter of amenities. Both passenger transportation in buses and coaches along with trucking that is as free of stress and fatigue as possible place high demands on vehicle technology, particularly climate control, ventilation and air-conditioning. For many years, renowned bus manufacturers have installed air-conditioning systems with brushless and wear-free centrifugal blowers and axial fans from ebm-papst. These products have also come to be used widely for climate control and ventilation of driver's cabs in trucks, tractors and construction equipment as well as in transport refrigeration systems. A wide variety of climate control system manufacturers rely the experience and excellent skills of ebm-papst in our core competencies of motor development, aerodynamics and electronics. 6 Fans and blowers: for commercial vehicle climate control and cooling of individual components.. Meeting high demands with new technology EC motors are energy-efficient, since the integrated electronics use con- In modern commercial vehicles, EC technology has now become the stan- tinuous closed loop speed control to draw from the vehicle electrical sys- dard. Our new second-generation EC axial fans and EC dual centrifugal tem only the energy actually required. In commercial vehicle applications, blowers set the trend in commercial vehicle climate control around the it is also important that fans withstand environmental influences wich are world. Our EC fans demonstrate their clear superiority even in hot climates constantly fluctuating. Standard products would provide less than satis- and tropical regions, where they have also already proven their excellent factory results in these situations. Therefore, ebm-papst automotive prod- performance. ucts also feature reliable protection against load dump, reverse polarity, But customers rely on ebm-papst products not only in the area of climate shock and vibration as well as damage from moisture and dirt in a wide control. Increasingly, EC fans are also finding application in the cooling of temperature range. This requires exceptional effort when selecting materi- heat exchangers in the engine compartment of vehicles. als and testing the products. We use extreme tests, which we have designed together with market-leading OEMs, based on real-world condi- In comparison: tions (such as salt spray fog, vibration and temperature change tests) to In commutator motors from other manufac- ensure the performance of the fans. turers, the commutator performs the task of distributing current to the coils. The commutator consists of copper segments embedded in an insulating compound. Mechanical springs press the integrated carbon brushes onto the commutator. The friction between these two mechanical components is the weak point of conventional DC motors. After a running time of approximately 5,000 hours, the carbon brushes and the commutator are worn out. As a result, the entire blower needs In addition to the significantly longer service life, our intelligent EC fans to be replaced. Furthermore, open loop speed guarantee extended open and closed loop control options. The function of control is possible only with external electron- the fans can be determined at any time via a diagnostic output. Moreover, ics. they have an excellent electromagnetic compatibility and operate extremely quietly. This is not true of brushless DC motors from ebm-papst. An electronic control integrated directly into these motors assumes the task of current But ebm-papst offers even more: distribution. No brushes means no parts to wear out. This increases the If you are ever unable to find a solution with our products, contact us. As a operating time of these motors to more than 40,000 hours. As a result, highly competent consultant and practically oriented implementer, we will the user not only saves on spare parts and repair costs, but also avoids certainly be able to identify a solution in your case using our in-depth unproductive downtimes and potential damage to reputation. knowledge gained from many applications. 7 8 EC dual centrifugal blowers with brushless DC motor "Premium" 9 EC dual centrifugal blowers with brushless DC motor, O 097 Flow rate speed/rpm Input power Current draw Min. back pressure Sound pressure level Perm. amb. temp. Mass Nominal data Type Motor VDC m3/h rpm W A Pa dB(A) C kg K3G 097-AK32 -42(1) M3G074-CF A 13 9-15 750 3630 195 15,0 300 63 -40..+85(2) 2,3 K3G 097-AK36 -55(1) M3G074-CF A B 13 9-15 1180 3740 385 29,5 0 69 -40..+85(2) 2,6 (1) A subject to alterations (2) 12-volt variant at free air not recommended for long-term operation at 85 C Air performance measured 2 Pa in H O Curves as per: ISO 5801, 4,0 in ebm-papst scroll housing Suction-side noise levels: LpA measured at 1 m distance to fan axis 800 3,0 B The acoustic values given are only valid under the measur- 4 ment conditions listed and 600 may vary depending on the 3 2,0 A installation situation. 4 With any deviation to the stan2 3 400 dard setup, the specific values have to be checked and reviewed once installed or fitted! 1,0 2 For detailed information 200 see page 58 ff. pfs 0 qV 10 100 200 200 300 400 400 600 500 800 600 1 cfm 1000 m 3/h n rpm Ped W I A L pA dB(A) A 1 --- --- --- --- A 2 3630 195 15,0 63 A 3 3875 177 13,5 64 A 4 4135 143 11,0 65 B 1 3740 385 29,5 69 B 2 4400 344 26,4 68 B 3 4775 309 23,8 69 B 4 4970 234 18,0 70 Installation category A, 1000 Electr. connection Nominal voltage range VDC Curve Nominal voltage - Material: Housing: PP plastic, coloured black (conforms to UL 94 HB) Impeller: PA plastic - Type of protection: IP 24 KM (without plug) - Insulation class: "B" in accordance with EN 60335-1 - Mounting position: Any - Mode of operation: Continuous operation (S1) - Bearings: Maintenance-free ball bearings on both sides - Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection, load dump protection, under-voltage detection - EMC requirements: VDE 0879-2, interference suppression grade 5 60 11 2.5 10 104 60 18 10 139.5 170.5 136 64.5 45 90 101 351 335 100 75.5 Direction of rotation O 4.5 217.5 View lead connection (K3G097-AK32-42) UN black PWM/LIN yellow GND brown 450+20 as of housing 8 View lead connection (K3G097-AK36-55) UN black PWM/LIN yellow GND brown 450+20 as of housing 6 Core-end sleeve tin-plated 11 Temp. control mod. p. 50 f. Connection leads p. 52 Electr. connection p. 53 EC dual centrifugal blowers with brushless DC motor, O 097 subject to alterations Perm. amb. temp. Mass rpm W A dB(A) C kg 690 26,5 75 -40..+60(3) 2,4 VDC VDC m3/h 26 16-32 1560 4600 24-volt variant (2) housing/impeller also available in V0 material (3) 2 Pa in H O Air performance measured as per: ISO 5801, 1200 4,0 Suction-side noise levels: LpA measured at 1 m distance 4 The acoustic values given are 3,2 800 to fan axis only valid under the measur- 3 ment conditions listed and 2,4 may vary depending on the 600 installation situation. With any deviation to the stan- 2 dard setup, the specific values 1,6 400 have to be checked and reviewed once installed or fitted! 0,8 qV 12 For detailed information see page 58 ff. 0 pfs 200 200 200 400 400 600 600 800 1000 800 1200 1400 1 cfm m 3/h n rpm Ped W I A L pA dB(A) A 1 4600 690 26,5 75 A 2 5095 604 23,2 74 A 3 5435 526 20,2 74 A 4 5720 365 14,0 74 Installation category A, in ebm-papst scroll housing 1000 G short-term operation at up to 85 C possible Curves A Electr. connection Sound pressure level A (1) Current draw M3G074-CF Input power K3G 097-AK68 -85(1)(2) speed/rpm Motor Flow rate Type Nominal voltage range Nominal data Nominal voltage Curve - Material: Housing: PP plastic, coloured black (conforms to UL 94 HB) Impeller: PA plastic - Type of protection: IP 24 KM (without plug) - Insulation class: "B" in accordance with EN 60335-1 - Mounting position: Any - Mode of operation: Continuous operation (S1) - Bearings: Maintenance-free ball bearings on both sides - Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection, load dump protection, under-voltage detection - EMC requirements: VDE 0879-2, interference suppression grade 3 60 11 2.5 10 104 60 18 10 139.5 170.5 136 64.5 45 90 101 351 335 100 75.5 Direction of rotation O 4.5 217.5 View connector plug 4-pole lead connection (450 mm) with plug Delphi Metri-Pack 280 Socket on customer side: Housing: Delphi 12129565 Secondary lock: Delphi 15300016 (TPA lock) Terminals: Delphi 12077411 Delphi 12077413 Seals: Delphi 15324981 Delphi 15324985 +20 D (GND) brown C (Diagnosis) white A (+UB) black B (PWM/LIN) yellow 1 kHz ... 50 kHz 0 V ... 10 V 450 0 13 Temp. control mod. p. 50 f. Electr. connection p. 55 EC dual centrifugal blowers with brushless DC motor, O 097 subject to alterations Sound pressure level Perm. amb. temp. Mass VDC VDC m3/h rpm W A Pa dB(A) C kg 16-32 1240 3730 390 15,0 0 70 26 (2) 24-volt variant Pa 4,0 in H2O Air performance measured as per: ISO 5801, Suction-side noise levels: 3,2 LpA measured at 1 m distance to fan axis 4 The acoustic values given are 2,4 only valid under the measur- 600 ment conditions listed and may vary depending on the installation situation. 3 With any deviation to the stan- 1,6 400 dard setup, the specific values have to be checked and reviewed once installed or fitted! 0,8 2 200 For detailed information see page 58 ff. pfs 1 0 qV 14 100 200 200 300 400 400 600 500 800 D 600 1000 700 cfm 1200 m3/h n rpm Ped W I A L pA dB(A) A 1 3730 390 15,0 70 A 2 4125 363 13,9 69 A 3 4490 309 11,9 69 A 4 4985 245 9,4 70 Installation category A, in ebm-papst scroll housing 800 -40..+85(2) 2,0 over + 70 C with power derating Curves 1000 Electr. connection Min. back pressure A (1) Current draw M3G084-BF Input power K3G 097-AF24 -01(1) speed/rpm Motor Flow rate Type Nominal voltage range Nominal data Nominal voltage Curve - Material: Housing: PP plastic, coloured black (conforms to UL 94 HB) Impeller: PA plastic - Type of protection: IP 24 KM, Electronics: IP 66 / 69 K - Insulation class: "B" in accordance with EN 60335-1 - Mounting position: Any - Mode of operation: Continuous operation (S1) - Bearings: Maintenance-free ball bearings on both sides - Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection, load dump protection, under-voltage detection - EMC requirements: VDE 0879-2, interference suppression grade 5 139.5 351 60 335 11 217.5 2.5 10 O 4.5 104 60 View connector plug 1 = UN black 2 = GND brown 3 = PWM/LIN yellow 4 = INVLIN orange 5 = LOWER blue 6 = Diagnostic output white AMP Junior Power Timer, 6-pole, coded; connection lead (460 mm) with mating plug Part no. 02001-4-1021 (not included in delivery) 170.5 136 45 64.5 90 101 18 10 100 75.5 5 3 6 1 2 4 15 Temp. control mod. p. 50 f. Connection leads p. 52 Electr. connection p. 54 EC dual centrifugal blowers with brushless DC motor, O 097 subject to alterations Sound pressure level Perm. amb. temp. Mass VDC VDC m3/h rpm W A Pa dB(A) C kg 16-32 1150 3960 375 14,4 0 70 26 (2) 24-volt variant Pa 4,0 in H2O Air performance measured as per: ISO 5801, Suction-side noise levels: 3,2 LpA measured at 1 m distance to fan axis 4 The acoustic values given are 2,4 only valid under the measur- 600 ment conditions listed and may vary depending on the installation situation. 3 With any deviation to the stan- 1,6 400 dard setup, the specific values have to be checked and reviewed once installed or fitted! 0,8 2 200 For detailed information see page 58 ff. pfs 1 0 qV 16 100 200 200 300 400 400 600 500 800 D 600 1000 700 cfm 1200 m3/h n rpm Ped W I A L pA dB(A) A 1 3960 375 14,4 70 A 2 4265 345 13,3 69 A 3 4535 309 11,9 69 A 4 5090 223 8,6 71 Installation category A, in ebm-papst scroll housing 800 -40..+85(2) 2,0 over + 70 C with power derating Curves 1000 Electr. connection Min. back pressure A (1) Current draw M3G084-BF Input power K3G 097-BF24 -01(1) speed/rpm Motor Flow rate Type Nominal voltage range Nominal data Nominal voltage Curve - Material: Housing: PP plastic, coloured black (conforms to UL 94 HB) Impeller: PA plastic - Type of protection: IP 24 KM, Electronics: IP 66 / 69 K - Insulation class: "B" in accordance with EN 60335-1 - Mounting position: Any - Mode of operation: Continuous operation (S1) - Bearings: Maintenance-free ball bearings on both sides - Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection, load dump protection, under-voltage detection - EMC requirements: VDE 0879-2, interference suppression grade 5 335 325 144.5 196 67 65 8.5 3 14.65 163.5 129 92 55 4.8 113.5 70 50 50 33.8 217.5 View connector plug 1 = UN black 2 = GND brown 3 = PWM/LIN yellow 4 = INVLIN orange 5 = LOWER blue 6 = Diagnostic output white AMP Junior Power Timer, 6-pole, coded; connection lead (460 mm) with mating plug Part no. 02001-4-1021 (not included in delivery) 5 3 6 1 2 4 17 Temp. control mod. p. 50 f. Connection leads p. 52 Electr. connection p. 54 18 EC dual centrifugal blowers with brushless DC motor Basic" 19 EC dual centrifugal blowers with brushless DC motor, O 097 Flow rate speed/rpm Input power Current draw Sound pressure level Perm. amb. temp. Mass Nominal data Type Motor VDC m3/h rpm W A dB(A) C kg K3G 097-AK34 -65(1) M3G074-CF 26 16-32 1290 3830 394 15,2 72 -40..+85(2) 2,0 A (1) subject to alterations 24-volt variant (2) 2 Pa in H O A Air performance measured 3830 394 15,2 72 4100 347 13,3 69 A 3 4380 285 10,9 68 A 4 4630 238 9,1 68 Suction-side noise levels: A 5 3150 215 8,3 68 LpA measured at 1 m distance A 6 3330 185 7,1 65 A 7 3510 149 5,7 63 The acoustic values given are A 8 3660 120 4,6 62 only valid under the measur- A 9 2240 79 3,1 59 A 10 2340 67 2,6 56 A 11 2430 53 2,0 54 A 12 4480 43 1,7 53 2,8 2,4 ment conditions listed and 3 may vary depending on the 80 % 1,6 400 installation situation. 8 With any deviation to the stan- 1,2 300 dard setup, the specific values 7 have to be checked and re2 0,8 200 viewed once installed or fitted! 60 % For detailed information 6 12 11 see page 58 ff. 0,4 100 10 9 pfs 0 qV 20 100 200 200 300 400 400 600 500 800 5 600 1000 1 700 cfm 1200 m 3/h L pA dB(A) 2 to fan axis 2,0 500 I A 1 in ebm-papst scroll housing 4 Ped W A Installation category A, 100 % n rpm A as per: ISO 5801, 800 600 F at free air not recommended for long-term operation at 85 C Curves 700 Electr. connection Nominal voltage range VDC Curve Nominal voltage - Material: Housing: PP plastic, coloured black (conforms to UL 94 HB) Impeller: PA plastic - Type of protection: IP 24 KM (without plug) - Insulation class: "B" in accordance with EN 60335-1 - Mounting position: Any - Mode of operation: Continuous operation (S1) - Bearings: Maintenance-free ball bearings on both sides - Motor protection: Overtemperature protection, locked-rotor protection, load dump protection, under-voltage detection - EMC requirements: e1 approval in accordance with 2006/28/EC 139.5 60 11 2.5 10 104 60 18 10 170.5 136 64.5 45 90 101 351 335 100 75.5 Direction of rotation O 4.5 217.5 Speed setting Pin 60% 5 4 3 H NC NC 80% NC H NC NC = not assigned 100% NC NC H H = UN (26 V) View connector plug 1 = + UB 2 = GND 3 = PWM/LIN, 100 % Speed 4 = 80 % Speed 5 = 60 % Speed 6 = NC (not assigned) AMP Junior Power Timer, 6-pole, coded; connection lead (460 mm) with mating plug; part no. 02001-4-1021 (not included in delivery) 5 3 1 2 4 6 21 Temp. control mod. p. 50 f. Connection leads p. 52 Electr. connection p. 55 EC dual centrifugal blowers with brushless DC motor, O 097 (1) subject to alterations Perm. amb. temp. Mass VDC VDC m3/h rpm W A dB(A) C kg 26 16-32 1110 4040 344 13,3 70 -40..+85(2) 2,0 (2) 24-volt variant 2 Air performance measured 3,2 2,4 600 4 4040 344 13,3 70 4210 325 12,5 69 A 3 4380 279 10,6 68 A 4 4630 242 9,2 68 Suction-side noise levels: A 5 3310 186 7,2 66 LpA measured at 1 m distance A 6 3390 171 6,6 64 A 7 3520 145 5,5 63 The acoustic values given are A 8 3650 121 4,6 62 only valid under the measur- A 9 2330 67 2,6 57 A 10 2360 62 2,4 55 A 11 2410 53 2,0 54 A 12 2480 42 1,6 400 53 2,0 ment conditions listed and installation situation. 3 80 % With any deviation to the standard setup, the specific values 1,2 8 300 have to be checked and re- 7 viewed once installed or fitted! 60 % 0,8 200 2 For detailed information 12 0,4 100 see page 58 ff. 6 11 10 pfs qV 22 100 200 200 300 400 400 600 1 5 9 0 500 800 600 1000 cfm m 3/h L pA dB(A) 2 may vary depending on the 1,6 500 I A 1 to fan axis 100 % Ped W A Installation category A, 2,8 700 n rpm A as per: ISO 5801, 3,6 Pa in H O A in ebm-papst scroll housing 800 F at free air not recommended for long-term operation at 85 C Curves 900 Electr. connection Sound pressure level A Current draw M3G074-CF Input power K3G 097-BK34 -65(1) speed/rpm Motor Flow rate Type Nominal voltage range Nominal data Nominal voltage Curve - Material: Housing: PP plastic, coloured black (conforms to UL 94 HB) Impeller: PA plastic - Type of protection: IP 24 KM (without plug) - Insulation class: "B" in accordance with EN 60335-1 - Mounting position: Any - Mode of operation: Continuous operation (S1) - Bearings: Maintenance-free ball bearings on both sides - Motor protection: Overtemperature protection, locked-rotor protection, load dump protection, under-voltage detection - EMC requirements: e1 approval in accordance with 2006/28/EC 335 8.5 144.5 113.5 65 163.5 129 70 92 55 4.8 50 325 67 50 3 Direction of rotation 196 217.5 Speed setting Pin 60% 5 4 3 H NC NC 80% NC H NC NC = not assigned 100% NC NC H H = UN (26 V) View connector plug 1 = + UB 2 = GND 3 = PWM/LIN, 100 % Speed 4 = 80 % Speed 5 = 60 % Speed 6 = NC (not assigned) AMP Junior Power Timer, 6-pole, coded; connection lead (460 mm) with mating plug; part no. 02001-4-1021 (not included in delivery) 5 3 1 2 4 6 23 Temp. control mod. p. 50 f. Connection leads p. 52 Electr. connection p. 55 24 EC axial fans with brushless DC motor Premium" and Power" 25 EC axial fans with brushless DC motor, O 280 subject to alterations Perm. amb. temp. Mass VDC VDC m3/h rpm W A dB(A) C kg 16-32 2400 3100 200 7,5 72 -40..+85(2) 2,4 26 (2) 24-volt variant 2 Pa in H O A Air performance measured as per: ISO 5801, 1,5 without protection against accidental contact Suction-side noise levels: LpA measured at 1 m distance 300 to fan axis 1,0 The acoustic values given are only valid under the measur4 ment conditions listed and may vary depending on the 200 installation situation. With any deviation to the stan3 0,5 dard setup, the specific values have to be checked and re- 100 viewed once installed or fitted! 2 For detailed information see page 58 ff. pfs qV 26 400 500 800 750 1200 1000 1600 1250 2000 1 cfm m 3/h n rpm Ped W I A L pA dB(A) A 1 3100 200 7,5 72 A 2 3085 197 7,6 72 A 3 3090 192 7,3 74 A 4 3105 213 8,2 76 Installation category A, 400 250 D at free air not recommended for long-term operation at 85 C Curves 0 Electr. connection Sound pressure level A (1) Current draw M3G074-CF Input power W3G280-EQ20 -43(1) speed/rpm Motor Flow rate Type Nominal voltage range Nominal data Nominal voltage Curve - Material: Wall ring: PP plastic, coloured black Impeller: PBT plastic, coloured black (conforms to UL 94 HB) - Direction of rotation: Clockwise, seen on rotor - Direction of air flow: "V", exhaust over struts - Type of protection: IP 24 KM - Insulation class: "B" in accordance with EN 60335-1 - Mounting position: Any - Mode of operation: Continuous operation (S1) - Bearings: Maintenance-free ball bearings - Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection, load dump protection, under-voltage detection - EMC requirements: VDE 0879-2, interference suppression grade 5 O292 O125 298 4.3 O294 8 172 1.5 21 .7 18 325 +20 8.5 X 57 O303 94+2 "V" 5 4 6 1 2 3 View X 1 = UN black 2 = GND brown 3 = PWM/LIN yellow 4 = INVLIN orange 5 = LOWER blue 6 = Diagnostic output white AMP Junior Power Timer, 6-pole, coded; connection lead (460 mm) with mating plug Part no. 02002-4-1021 (not included in delivery) 27 Temp. control mod. p. 50 f. Connection leads p. 52 Electr. connection p. 54 EC axial fans with brushless DC motor, O 300 (1) subject to alterations Perm. amb. temp. Mass VDC VDC m3/h rpm W A dB(A) C kg 13 9-16 2610 3200 220 16,7 (2) 12-volt variant 75 -40..+105(2) 2,0 2 Pa in H O A Air performance measured as per: ISO 5801, without protection against 1,2 accidental contact Suction-side noise levels: LpA measured at 1 m distance to fan axis 1,0 4 The acoustic values given are 0,8 only valid under the measur- 200 ment conditions listed and 3 may vary depending on the 0,6 installation situation. 150 With any deviation to the stan- 0,4 dard setup, the specific values 100 have to be checked and re- 2 viewed once installed or fitted! For detailed information 0,2 50 see page 58 ff. pfs 0 qV 28 250 400 500 800 750 1200 1000 1600 1250 2000 1 1500 2400 cfm m 3/h n rpm Ped W I A L pA dB(A) A 1 3200 220 16,7 75 A 2 3140 235 18,1 75 A 3 2960 247 18,9 73 A 4 2840 248 19,0 75 Installation category A, 350 250 K over + 85 C with power derating Curves 300 Electr. connection Sound pressure level A Current draw M3G084-BF Input power W3G300-BV12 -41(1) speed/rpm Motor Flow rate Type Nominal voltage range Nominal data Nominal voltage Curve - Material: Wall ring: PA plastic, coloured black Impeller: PA plastic, coloured black (conforms to UL 94 HB) - Direction of rotation: Clockwise, seen on rotor - Direction of air flow: "V", exhaust over struts - Type of protection: Motor: IP 24 KM, Electronics: IP 66 / 69 K - Insulation class: "B" in accordance with EN 60335-1 - Mounting position: Any - Mode of operation: Continuous operation (S1) - Bearings: Maintenance-free ball bearings - Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection, load dump protection, under-voltage detection - EMC requirements: VDE 0879-2, interference suppression grade 5 - Qualified to: DIN ISO 16750 +2 76.5 0 +2 54 0 9. 5 16 330 O318 0 +1 4x9 0 5 7. O34 0 O3 37 24 X +20 300 0 "V" 5 4 6 1 2 3 View X 1 = + UB black 2 = GND brown 3 = PWM/LIN* yellow 4 = NC (not assigned) 5 = LOWER blue 6 = Diagnostic output white AMP Junior Power Timer, 6-pole, coded; connection lead (460 mm) with mating plug Part no. 02002-4-1021 (not included in delivery) * optionally LIN-BUS 29 Temp. control mod. p. 50 f. Connection leads p. 52 Electr. connection p. 56 EC axial fans with brushless DC motor, O 300 Perm. amb. temp. Mass VDC m3/h rpm W A dB(A) C kg 16-32 2570 3160 205 (2) 24-volt variant 7,90 74 -40..+110(2) 2,0 2 Pa in H O A Air performance measured as per: ISO 5801, without protection against 1,2 accidental contact Suction-side noise levels: LpA measured at 1 m distance 1,0 to fan axis 4 The acoustic values given are 0,8 only valid under the measur- 200 ment conditions listed and may vary depending on the installation situation. 150 0,6 3 With any deviation to the standard setup, the specific values have to be checked and re- 0,4 100 viewed once installed or fitted! 2 For detailed information 0,2 50 see page 58 ff. pfs 0 qV 30 250 400 500 800 750 1200 1000 1600 1250 2000 1 1500 2400 cfm m 3/h n rpm Ped W I A L pA dB(A) A 1 3160 205 7,90 74 A 2 3150 216 8,30 73 A 3 3085 240 9,20 73 A 4 2965 244 9,40 73 Installation category A, 350 250 H over + 95 C with power derating Curves 300 Electr. connection Sound pressure level VDC 26 A (1) subject to alterations Current draw M3G084-BF Input power W3G300-BV24 -01(1) speed/rpm Motor Flow rate Type Nominal voltage range Nominal data Nominal voltage Curve - Material: Wall ring: PA plastic, coloured black Impeller: PA plastic, coloured black (conforms to UL 94 HB) - Direction of rotation: Clockwise, seen on rotor - Direction of air flow: "V", exhaust over struts - Type of protection: Motor: IP 24 KM, Electronics: IP 66 / 69 K - Insulation class: "B" in accordance with EN 60335-1 - Mounting position: Any - Mode of operation: Continuous operation (S1) - Bearings: Maintenance-free ball bearings - Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection, load dump protection, under-voltage detection - EMC requirements: VDE 0879-2, interference suppression grade 5 - Qualified to: DIN ISO 16750 +2 76.5 0 +2 54 0 9. 5 16 330 O318 0 +1 4x9 0 5 7. O34 0 O3 37 24 X +20 300 0 "V" 5 4 6 1 2 3 View X 1 = + UB black 2 = GND brown 3 = PWM/LIN* yellow 4 = INVLIN orange 5 = LOWER blue 6 = Diagnostic output white AMP Junior Power Timer, 6-pole, coded; connection lead (460 mm) with mating plug Part no. 02002-4-1021 (not included in delivery) * optionally LIN-BUS 31 Temp. control mod. p. 50 f. Connection leads p. 52 Electr. connection p. 56 EC axial fans with brushless DC motor, O 300 Perm. amb. temp. Mass VDC m3/h rpm W A dB(A) C kg 16-32 3225 3940 380 14,6 24-volt variant (2) 79 -40..+110(2) 2,0 2 Pa 2,4 in H O A Air performance measured as per: ISO 5801, 2,0 accidental contact Suction-side noise levels: LpA measured at 1 m distance 4 400 1,6 to fan axis The acoustic values given are only valid under the measurment conditions listed and 300 1,2 3 may vary depending on the installation situation. 0,8 With any deviation to the stan- 200 dard setup, the specific values have to be checked and re- 2 100 0,4 viewed once installed or fitted! For detailed information see page 58 ff. 1 pfs 0 qV 32 250 500 500 750 1000 1000 1500 1250 2000 cfm 1500 2500 3000 m 3/h n rpm Ped W I A L pA dB(A) A 1 3940 380 14,6 79 A 2 3815 408 15,7 79 A 3 3715 462 17,7 78 A 4 3630 495 19,0 81 Installation category A, without protection against 500 H over + 85 C with power derating Curves 600 Electr. connection Sound pressure level VDC 26 A (1) subject to alterations Current draw M3G084-BF Input power W3G300-BV25 -21(1) speed/rpm Motor Flow rate Type Nominal voltage range Nominal data Nominal voltage Curve - Material: Wall ring: PA plastic, coloured black Impeller: PA plastic, coloured black (conforms to UL 94 HB) - Direction of rotation: Clockwise, seen on rotor - Direction of air flow: "V", exhaust over struts - Type of protection: Motor: IP 24 KM, Electronics: IP 66 / 69 K - Insulation class: "B" in accordance with EN 60335-1 - Mounting position: Any - Mode of operation: Continuous operation (S1) - Bearings: Maintenance-free ball bearings - Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection, load dump protection, under-voltage detection - EMC requirements: VDE 0879-2, interference suppression grade 5 - Qualified to: DIN ISO 16750 +2 76.5 0 +2 54 0 9. 5 16 330 O318 0 +1 4x9 0 5 7. O34 0 O3 37 24 X +20 300 0 "V" 5 4 6 1 2 3 View X 1 = + UB black 2 = GND brown 3 = PWM/LIN* yellow 4 = INVLIN orange 5 = LOWER blue 6 = Diagnostic output white AMP Junior Power Timer, 6-pole, coded; connection lead (460 mm) with mating plug Part no. 02002-4-1021 (not included in delivery) * optionally LIN-BUS 33 Temp. control mod. p. 50 f. Connection leads p. 52 Electr. connection p. 56 EC axial fans with brushless DC motor, O 300 (1) subject to alterations Max. back pressure Perm. amb. temp. Mass VDC VDC m3/h rpm W A dB(A) Pa C kg 27,5 16-32 3135 3320 335 12,2 87 24-volt variant (2) 275 -40..+85(2) 2 Pa in H O A Air performance measured as per: ISO 5801, 1,5 without protection against accidental contact Suction-side noise levels: LpA measured at 1 m distance 300 to fan axis 1,0 The acoustic values given are only valid under the measur3 ment conditions listed and may vary depending on the 200 installation situation. With any deviation to the stan0,5 dard setup, the specific values have to be checked and re2 100 viewed once installed or fitted! For detailed information see page 58 ff. 1 pfs qV 34 500 500 1000 750 1000 1500 1250 2000 C cfm 1500 2500 3000 m 3/h n rpm Ped W I A L pA dB(A) A 1 3320 335 12,2 87 A 2 3295 354 12,8 85 A 3 3255 367 13,3 86 Installation category A, 400 250 2,5 at free air not recommended for long-term operation at 85 C Curves 0 Electr. connection Sound pressure level A Current draw M3G074-CF Input power W3G300-ER38 -45(1) speed/rpm Motor Flow rate Type Nominal voltage range Nominal data Nominal voltage Curve - Material: Wall ring: PP plastic, coloured black Impeller: PBT plastic, coloured black (conforms to UL 94 HB) - Direction of rotation: Clockwise, seen on rotor - Direction of air flow: "A", intake over struts - Type of protection: IP 24 KM - Insulation class: "B" in accordance with EN 60335-1 - Mounting position: Any - Mode of operation: Continuous operation (S1) - Bearings: Maintenance-free ball bearings - Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection, load dump protection, under-voltage detection - EMC requirements: VDE 0879-2, interference suppression grade 5 7 O3 40 37 O3 3.5 O318 +1 1.5 O323 O315 O125 O330 4x90 4.3 2.5 3.5 O6.8 6 15 0' 64 X 57 360 +20 94+2 Bushing on customer side: Housing: Packard 12015797 Pins: Packard 12089188 Packard 12124580 Sealings: Packard 15324982 Packard 15324983 A B C View X A = UN B = LIN C = CGND D = GND "A" rde blue white black D 35 Temp. control mod. p. 50 f. Electr. connection p. 54 EC axial fans with brushless DC motor, O 385 (1) subject to alterations Perm. amb. temp. Mass VDC VDC m3/h rpm W A dB(A) C kg 13 9-16 4110 3100 445 34,0 (2) 12-volt variant 81 -40..+105(2) 3,3 2 Pa in H O A Air performance measured as per: ISO 5801, 2,0 without protection against accidental contact Suction-side noise levels: 4 1,6 LpA measured at 1 m distance to fan axis The acoustic values given are 1,2 only valid under the measur- 300 ment conditions listed and 3 may vary depending on the installation situation. With any deviation to the stan- 0,8 200 dard setup, the specific values 2 have to be checked and re- 0,4 viewed once installed or fitted! 100 For detailed information see page 58 ff. 1 pfs 0 qV 36 500 500 1000 1000 1500 1500 2000 2500 cfm 2000 3000 3500 4000 m 3/h n rpm Ped W I A L pA dB(A) A 1 3100 445 34,0 81 A 2 3000 487 37,6 80 A 3 2930 544 41,9 78 A 4 2815 590 45,6 81 Installation category A, 400 L over + 70 C with power derating Curves 500 Electr. connection Sound pressure level A Current draw M3G084-CF Input power W3G385-CT53 -61(1) speed/rpm Motor Flow rate Type Nominal voltage range Nominal data Nominal voltage Curve - Material: Wall ring: PA plastic, coloured black Impeller: PA plastic, coloured black (conforms to UL 94 HB) - Direction of rotation: Clockwise, seen on rotor - Direction of air flow: "V", exhaust over struts - Type of protection: Motor: IP 24 KM, Electronics: IP 66 / 69 K - Insulation class: "B" in accordance with EN 60335-1 - Mounting position: Any - Mode of operation: Continuous operation (S1) - Bearings: Maintenance-free ball bearings - Motor protection: Overtemperature protection, locked-rotor protection, load dump protection, under-voltage detection - EMC requirements: VDE 0879-2, interference suppression grade 5 - Qualified to: DIN ISO 16750 +2 5 89.5 0 9. +2 55 0 16 4x9 0 5 7. 399 O396 0 +2 17 1 O41 4 O4 22 24 X +20 0 270 "V" Bushing on customer side: Housing: FCI 30432101 Pins: 9,5 mm FCI 60070461 4,8 mm FCI 60040431 Sealings: FCI 60993301 FCI 60992607 4 2 3 View X 1 = + UB 2 = Diagnostic output* 3 = PWM/LIN 4 = GND black white yellow brown 1 * optionally LIN-BUS 37 Temp. control mod. p. 50 f. Electr. connection p. 53 EC axial fans with brushless DC motor, O 385 Perm. amb. temp. Mass VDC m3/h rpm W A dB(A) C kg 16-32 3425 2600 260 10,0 24-volt variant (2) 76 -40..+110(2) 2,7 2 Pa in H O A Air performance measured as per: ISO 5801, 1,4 without protection against 1,2 accidental contact Suction-side noise levels: LpA measured at 1 m distance 1,0 250 to fan axis 4 The acoustic values given are 0,8 only valid under the measur- 200 ment conditions listed and 3 may vary depending on the 0,6 installation situation. 150 With any deviation to the stan- 0,4 dard setup, the specific values 100 have to be checked and re- 2 viewed once installed or fitted! For detailed information 0,2 50 see page 58 ff. pfs 0 qV 38 250 500 500 750 1000 1000 1500 1250 2000 1 cfm 1500 2500 3000 m 3/h n rpm Ped W I A L pA dB(A) A 1 2600 260 10,0 76 A 2 2505 272 10,5 74 A 3 2325 273 10,5 73 A 4 2215 274 10,5 74 Installation category A, 300 H over + 95 C with power derating Curves 350 Electr. connection Sound pressure level VDC 26 A (1) subject to alterations Current draw M3G084-BF Input power W3G385-BV44 -01(1) speed/rpm Motor Flow rate Type Nominal voltage range Nominal data Nominal voltage Curve - Material: Wall ring: PA plastic, coloured black Impeller: PA plastic, coloured black (conforms to UL 94 HB) - Direction of rotation: Clockwise, seen on rotor - Direction of air flow: "V", exhaust over struts - Type of protection: Motor: IP 24 KM, Electronics: IP 66 / 69 K - Insulation class: "B" in accordance with EN 60335-1 - Mounting position: Any - Mode of operation: Continuous operation (S1) - Bearings: Maintenance-free ball bearings - Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection, load dump protection, under-voltage detection - EMC requirements: VDE 0879-2, interference suppression grade 5 - Qualified to: DIN ISO 16750 +2 79.5 0 9. 5 +2 55 0 16 399 O396 0 +2 4x9 0 5 7. O41 4 O4 22 24 X +20 270 0 "V" 5 4 6 1 2 3 View X 1 = + UB black 2 = GND brown 3 = PWM/LIN* yellow 4 = INVLIN orange 5 = LOWER blue 6 = Diagnostic output white AMP Junior Power Timer, 6-pole, coded; connection lead (460 mm) with mating plug Part no. 02002-4-1021 (not included in delivery) * optionally LIN-BUS 39 Temp. control mod. p. 50 f. Connection leads p. 52 Electr. connection p. 56 EC axial fans with brushless DC motor, O 385 Perm. amb. temp. Mass VDC m3/h rpm W A dB(A) C kg 16-32 4375 3300 525 20,0 (2) 24-volt variant 83 -40..+110(2) 3,1 2 Pa 2,4 in H O A Air performance measured as per: ISO 5801, 2,0 accidental contact Suction-side noise levels: LpA measured at 1 m distance 4 1,6 400 to fan axis The acoustic values given are 3 only valid under the measur- 1,2 ment conditions listed and 300 may vary depending on the installation situation. 2 0,8 With any deviation to the stan- 200 dard setup, the specific values have to be checked and re- 0,4 viewed once installed or fitted! 100 For detailed information see page 58 ff. pfs 500 qV 40 500 1000 1000 1500 1500 2000 2500 1 cfm 2000 3000 3500 4000 m 3/h n rpm Ped W I A L pA dB(A) A 1 3300 525 20,0 83 A 2 3180 615 23,7 81 A 3 3050 610 23,5 80 A 4 2920 610 23,6 80 Installation category A, without protection against 500 L over + 85 C with power derating Curves 600 Electr. connection Sound pressure level VDC 26 A (1) subject to alterations Current draw M3G084-CF Input power W3G385-CT65 -21(1) speed/rpm Motor Flow rate Type Nominal voltage range Nominal data Nominal voltage Curve - Material: Wall ring: PA plastic, coloured black Impeller: PA plastic, coloured black (conforms to UL 94 HB) - Direction of rotation: Clockwise, seen on rotor - Direction of air flow: "V", exhaust over struts - Type of protection: Motor: IP 24 KM, Electronics: IP 66 / 69 K - Insulation class: "B" in accordance with EN 60335-1 - Mounting position: Any - Mode of operation: Continuous operation (S1) - Bearings: Maintenance-free ball bearings - Motor protection: Overtemperature protection, locked-rotor protection, load dump protection, under-voltage detection - EMC requirements: VDE 0879-2, interference suppression grade 5 - Qualified to: DIN ISO 16750 +2 5 89.5 0 9. +2 55 0 16 4x9 0 5 7. 399 O396 0 +2 17 1 O41 4 O4 22 24 X +20 0 270 "V" Bushing on customer side: Housing: FCI 30432101 Pins: 9,5 mm FCI 60070461 4,8 mm FCI 60040431 Sealings: FCI 60993301 FCI 60992607 4 2 3 View X 1 = + UB 2 = Diagnostic output* 3 = PWM/LIN 4 = GND black white yellow brown 1 * optionally LIN-BUS 41 Temp. control mod. p. 50 f. Electr. connection p. 53 42 EC centrifugal fans - RadiCal backward curved 43 EC centrifugal fan RadiCal backward curved, O 220 Perm. amb. temp. Mass VDC VDC m3/h rpm W A dB(A) C kg 24 16-28 1030 2975 104 5,0 --- -40..+60 1,4 Pa in H2O Air performance measured as per: ISO 5801, in ebm-papst full nozzle 2,4 and without protection against accidental contact 2,0 Suction-side noise levels: 500 LpA measured at 1 m distance to fan axis 4 The acoustic values given are 1,6 400 only valid under the measurment conditions listed and may vary depending on the 1,2 300 installation situation. 3 0,8 With any deviation to the stan- 200 dard setup, the specific values have to be checked and re- 2 0,4 viewed once installed or fitted! 100 For detailed information see page 58 ff. pfs 1 0 qV 44 100 200 200 300 400 400 600 500 800 600 cfm 1000 m3/h n rpm Ped W I A L pA dB(A) A 1 2975 104 5,0 --- A 2 2890 105 5,1 --- A 3 2775 108 5,1 --- A 4 2920 106 5,1 --- Installation category A, 600 E Also possible as 12-volt variant Curves 700 Electr. connection Sound pressure level A (1) Current draw M1G074-BF subject to alterations Input power R1G 220-RD02 -02(1) speed/rpm Motor Flow rate Type Nominal voltage range Nominal data Nominal voltage Curve - Material: Impeller: Plastic PA 6.6 GV, coloured black Electronics housing: Die-cast aluminium, coated in black - Direction of rotation: Clockwise, seen on rotor - Type of protection: Motor: IP 24, Electronics: IP 66 / 69 K - Insulation class: "B" in accordance with EN 60335-1 - Mounting position/condensate discharges: Rotor on bottom with condensate discharge holes is standard - Mode of operation: Continuous operation (S1) - Bearings: Maintenance-free ball bearings - Motor protection: reverse polarity and locked-rotor protection - Technical features: Control input 0-10 VDC / PWM, tach output - Mounting situation: The parameters of the specific installation situation must be co-ordinated with ebm-papst! Type Inlet nozzle R1G 220-RD02 -02 09609-2-4013 Accessory part: Inlet nozzle not included in the standard scope of delivery 73.2 711 45 63.7 Depth of screw max. 6 mm R2 M4 (4x) O252 0.8 450+20 6 85 10 O155 O220 4x90 O1610.2 1.8 O88 O580.15 21 Number of blades = 7 2 2 Insulating sleeve with single strands 4x 0,75 mm , 4 x brass lead tips crimped. Cable assignment UB red Lin/PWM yellow Tach output white GND blue 45 Temp. control mod. p. 50 f. Electr. connection p. 55 EC centrifugal fan RadiCal backward curved, O 250 Perm. amb. temp. Mass VDC VDC m3/h rpm W A dB(A) C kg 24 16-28 1280 2440 105 4,9 --- -40..+60 1,9 Pa in H2O Air performance measured as per: ISO 5801, 2,4 in ebm-papst full nozzle and without protection against 2,0 accidental contact Suction-side noise levels: LpA measured at 1 m distance 4 400 1,6 to fan axis The acoustic values given are only valid under the measur1,2 300 ment conditions listed and 3 may vary depending on the installation situation. With any deviation to the stan- 0,8 200 dard setup, the specific values have to be checked and re- 2 0,4 viewed once installed or fitted! 100 For detailed information see page 58 ff. pfs 1 0 qV 46 100 200 200 300 400 400 600 500 800 600 1000 700 cfm 1200 m3/h n rpm Ped W I A L pA dB(A) A 1 2440 105 4,9 --- A 2 2275 108 5,2 --- A 3 2255 110 5,2 --- A 4 2425 105 4,9 --- Installation category A, 500 E Also possible as 12-volt variant Curves 600 Electr. connection Sound pressure level A (1) Current draw M1G074-CF subject to alterations Input power R1G 250-RC69 -02(1) speed/rpm Motor Flow rate Type Nominal voltage range Nominal data Nominal voltage Curve - Material: Impeller: Plastic PA 6.6 GV, coloured black Electronics housing: Die-cast aluminium, coated in black - Direction of rotation: Clockwise, seen on rotor - Type of protection: Motor: IP 24, Electronics: IP 66 / 69 K - Insulation class: "B" in accordance with EN 60335-1 - Mounting position/condensate discharges: Rotor on bottom with condensate discharge holes is standard - Mode of operation: Continuous operation (S1) - Bearings: Maintenance-free ball bearings - Motor protection: reverse polarity and locked-rotor protection - Technical features: Control input 0-10 VDC / PWM, tach output - Mounting situation: The parameters of the specific installation situation must be co-ordinated with ebm-papst! Type Inlet nozzle R1G 250-RC69 -02 96359-2-4013 Accessory part: Inlet nozzle not included in the standard scope of delivery O580.15 O4.5(4x) 891 85 Depth of screw max. 6 mm 45 M4 (4x) R2 1.5 6 31 450+20 8510 O255 O240 O164.5 O250 O172.5+0.3 -0.5 4x 90 O88 8 Number of blades = 7 2 2 Insulating sleeve with single strands 4x 0,75 mm , 4 x brass lead tips crimped. Cable assignment UB red Lin/PWM yellow Tach output white GND blue 47 Temp. control mod. p. 50 f. Electr. connection p. 55 EC centrifugal fan RadiCal backward curved, O 280 Perm. amb. temp. Mass VDC VDC m3/h rpm W A dB(A) C kg 26 16-32 2750 2350 252 10,5 72 -40..+60 2,8 Electr. connection Sound pressure level A Current draw M3G084-CF Input power R3G 280-RU26 -81 speed/rpm Motor Flow rate Type Nominal voltage range Nominal data Nominal voltage Curve - Material: Impeller: Plastic PA, coloured black (conforms to UL 94 V0) Rotor: Coated in black Electronics housing: Die-cast aluminium, coated in black - Direction of rotation: Clockwise, seen on rotor - Type of protection: Motor: IP 24 KM, Electronics: IP 66 / 69 K - Insulation class: "B" in accordance with EN 60335-1 - Mounting position: Any - Mode of operation: Continuous operation (S1) - Bearings: Maintenance-free ball bearings - Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection, load dump protection, under-voltage detection - Qualified to: DIN ISO 16750 H subject to alterations Air performance measured in H2O Pa Curves as per: ISO 5801, 2,4 in ebm-papst full nozzle and without protection against accidental contact 500 2,0 4 Suction-side noise levels: LpA measured at 1 m distance 400 1,6 to fan axis 3 The acoustic values given are only valid under the measur1,2 ment conditions listed and 300 may vary depending on the 200 0,8 installation situation. With any deviation to the stan- 2 dard setup, the specific values have to be checked and re0,4 viewed once installed or fitted! 100 For detailed information pfs see page 58 ff. 0 qV 48 200 400 400 600 800 800 1200 1000 1600 1200 2000 1400 2400 1 1600 cfm 2800 m3/h Ped W I A L pA dB(A) A 1 2350 252 10,5 72 A 2 2300 300 12,5 68 A 3 2265 328 13,7 68 A 4 2315 298 12,4 69 Installation category A, 600 n rpm Type Inlet nozzle R3G 280-RU26 -81 28000-2-4013 Depth of screw max. 8 mm (core removing hole prepared for self-tapping screw) Accessory part: Inlet nozzle not included in the standard scope of delivery Depth of screw max. 10 mm (core removing hole prepared for self-tapping screw) Depth of screw max. 12 mm (core removing hole prepared for self-tapping screw) 14 O4.5(x4) 148,5 1 127 M6 1.25 46 X 5 4 6 1 2 3 8 46 0+ 20 11 2 144 O260 O280 O182 O176.7 O102.2 O187.5 0.3 O294 4x9 0 Number of blades = 6 M5 M4 O58 0.2 O75 0.2 O115 0.2 View X 1 = + UB black 2 = GND brown 3 = PWM/LIN* yellow orange 4 = INVLIN 5 = LOWER blue 6 = Diagnostic output white AMP Junior Power Timer, 6-pole, coded; connection lead (460 mm) with mating plug Part no. 02002-4-1021 (not included in delivery) * optionally LIN-BUS 49 Temp. control mod. p. 50 f. Electr. connection p. 53 Temperature control module Nominal voltage Current draw Output voltage Output current Output impedance Temperature control range Mass - Type of protection: IP42 VDC mA VDC mA k C kg 50002-1-0174 18-60 10 2-10 0,1 6,8 +30..+55 0,02 50003-1-0174 18-60 10 0-10 0,1 6,8 +10..+45 0,02 Nominal data Part no. subject to alterations - Electr. connection: O4,9 84,7 yellow 2-10 VDC or 0-10 VDC output 45 37,5 6,5 Maximum ripple 3.5 % yellow Control input 0 - 10 VDC 47 K Counter Isink max. 10 mA Controller 5 white Output (yellow) + (red) - (blue) Core-end sleeve Speed display 450 +20 38,5 680 Tach output, pulses per revolution Alarm 6,9 13 red red 18-60 VDC 47 K 10,1 2,5 O7 +0,5 O3,5 8 3,3 3 +0,2 47 V blue blue GND 6 85 Temperature control module Connection Fans - Control function: Both designs have "cooling" as control function U/V U/V 10 10 2 1 0 30 55 50002-1-0174 Tolerance 3 K 50 Temp. C 0 6 10 45 50003-1-0174 Temp. C Temperature sensor Output current Output impedance Temperature measuring range Mass 50005-1-0174 Output voltage Part no. Current draw Nominal data Nominal voltage - Type of protection: IP42 VDC mA VDC mA k C kg 15-30 10 0-10 1,0 1,1 -20..+80 0,02 subject to alterations 10,1 2,5 O7 +0,5 - Electr. connection: O4,9 O3,5 red 15-30 VDC 8 3,3 3 +0,2 84,7 yellow 0-10 VDC output 45 37,5 38,5 Output (yellow) + (red) - (blue) Core-end sleeve 450 +20 6,9 5 13 6,5 blue 6 85 Temperature sensor - Output voltage depending on temperature: U/V 10 0 -20 80 Temp. C Tolerance 3 K 51 Accessories 460 25 8 02001-4-1021 Core-end sleeve 60 460 25 8 02002-4-1021 60 Connection leads Part no. Application 02001-4-1021 EC dual centrifugal blower 02002-4-1021 EC axial fan subject to alterations 52 Core-end sleeve Electrical connections A) 13 VDC electrical connection (EC dual centrifugal blowers "Premium") Notes on various control possibilities and their applications 33 k 1 (black) 2 (yellow) UN +13 VDC 1k PWM/LIN RE typ. 75 k 0 V to 10 V PWM + U 4 12 V Speed setting PWM 1 kHz - 50 kHz 100 % PWM -> n=max 10 % PWM -> n=min 0 % PWM -> Standby 3 - 10 k Speed setting with potentiometer Full speed GND (brown) Speed setting 0 V - 10 V 10 V -> n=max 1 V -> n=min 0 V -> Standby Customer circuit Connection Fan L) 13 VDC electrical connection (EC axial fans Power") Notes on various control possibilities and their applications 1 (black) 3 (yellow) UB +13 VDC 1k PWM/LIN RE typ. 44 k 0 V to 10 V + PWM U - 10 k 12 V Speed setting PWM 5 Hz - 100 kHz 100 % PWM -> n=max 15 % PWM -> n=min 0 % PWM -> Standby Speed setting with potentiometer Full speed Diagnostic output Operation: output level low (U = 0 V) Rotor locked or overtemperature or overvoltage/undervoltage: output level high (U = UB - 2 V) Imax = 50 mA Collective fault signal possible Customer circuit Speed setting 0 V - 10 V 10 V -> n=max 1,5 V -> n=min 0 V -> Standby 2 (white) Diagnostic output 4 (brown) GND Connection 0.05 k Fan 53 Electrical connections C) 27.5 VDC electrical connection Notes on various control possibilities and their applications A (red) UN +27.5 VDC B (blue) LIN C (white) CGND D (black) GND nmax nmin RE typ. 17 k + 0.75 V U 5V - Speed setting 5 V -> n=max 0.75 V -> n=min 0 V -> Standby max. permitted offset voltage 1.5 V Customer circuit Connection Fan D) 26 VDC electrical connection Notes on various control possibilities and their applications 1 (black) 3 (yellow) UN +26 VDC 4.7 k PWM/LIN RE typ. 75 k 0 V to 10 V + PWM U - 10 k The blower speed is determined by the input (pin 3, 4) that gives the higher speed. 12 V Speed setting PWM 5 Hz - 100 kHz 100 % PWM -> n=max 15 % PWM -> n=min 0 % PWM -> Standby Speed setting with potentiometer Full speed Speed setting 0 V - 10 V 10 V -> n=max 1,5 V -> n=min 0 V -> Standby U Standby threshold UB 32 V Switch on: typ. 1.5 V off: typ. 1 V 21 V Full speed (orange) INVLIN RE typ. 100 k 6 (white) Diagnostic output 0.05 k 5 (blue) LOWER 47 k 2 (brown) + U Motor stops Switch-on threshold Motor turns UB 21 V 32 V Speed setting: 21 V -> n=min 0 V -> n=max UB -> Standby Diagnostic output Operation: output level low (U = 0 V) Rotor locked or overtemperature: output level high (U = UB - 2 V) Imax = 50 mA Collective fault signal possible Customer circuit 54 4 Standby Speed - lower Input UB -> n/2 open -> n Connection GND Fan E) 24 VDC electrical connection Notes on various control possibilities and their applications Maximum ripple 3.5% red 33 K 4.7 K Lin/PWM control input 0-10 VDC / PWM RE > 100 k yellow Counter Isink max. 10 mA Tach output pulses per revolution Controller U PWM white 10 K 680 Alarm Speed display 12 V 47 V Temperature control module Speed setting Speed setting with potentiometer PWM 1 kHz - 50 kHz 50002-1-0174 50003-1-0174 Full speed GND blue Speed setting 1 V - 10 V 100% PWM -> n=max approx. 10% PWM -> n=min < 10% PWM -> n=0 10 V -> n=max approx. 1 V -> n=min < 1 V -> n=0 Safe start at UNom -30 % from 40 % PWM Safe start at UNom -30 % from 4 V Ucontr Customer circuit Connection Fan F) 26 VDC electrical connection (EC dual centrifugal blowers "Basic") Notes on various control possibilities and their applications 1 UN +26 VDC 4.7 k 3 RE typ. 75 k PWM/LIN 0 V to 10 V (100 %) 4 + PWM RE typ. 75 k U (80 %) - 10 k RE typ. 75 k 5 (60 %) 12 V 6 2 Speed setting PWM 1 kHz - 50 kHz 10 V -> n=max 1 V -> n=min 0 V -> Standby Speed setting with potentiometer Speed setting 0 V - 10 V 10 V -> n=max 1 V -> n=min 0 V -> Standby Full speed 80 % speed Customer circuit GND 60 % speed Connection Fan G) 26 VDC electrical connection (EC dual centrifugal blowers Premium/Power") Notes on various control possibilities and their applications 1 (black) 2 (yellow) UN +26 VDC 4,7 k PWM/LIN RE typ 75 k 0 V .. 10 V 22 k + PWM 3 U 4 Speed setting with potentiometer DU 3 k Imax=10mA 12 V Speed setting PWM 1 kHz - 50 kHz 100 % PWM->n=max 10 % PWM->n=min 0 % PWM->Standby (white) - 10 k Full speed Customer circuit Speed setting 0 V - 10 V 10 V -> n=max 1 V -> n=min 0 V -> Standby Temperature control module 50002-1-0174 50003-1-0174 (brown) GND Diagnostic output Operation: output level high (U = UB - 2 V) Rotor locked or overtemperature: output level low (U = 0 V) Imax = 10 mA Collective fault signal possible Connection Fan 55 Electrical connections K) 13 VDC electrical connection (EC axial fans Premium") Notes on various control possibilities and their applications 1 (black) 3 (yellow) UB +13 VDC 1k PWM/LIN RE typ. 44 k 0 V to 10 V + PWM U - 10 k The blower speed is determined by the input (pin 3, 4) that gives the higher speed. 12 V Speed setting PWM 5 Hz - 100 kHz 100 % PWM -> n=max 15 % PWM -> n=min 0 % PWM -> Standby Speed setting with potentiometer Full speed Speed setting 0 V - 10 V 10 V -> n=max 1,5 V -> n=min 0 V -> Standby Diagnostic output Operation: output level low (U = 0 V) Rotor locked or overtemperature or overvoltage/undervoltage: output level high (U = UB - 2 V) Imax = 50 mA Collective fault signal possible Speed - lower Input UB -> n/2 open -> n Customer circuit 4 NC 6 (white) Diagnostic output 0.05 k 5 (blue) LOWER 47 k 2 (brown) GND Connection Fan H) 26 VDC electrical connection (EC axial fans Premium/Power") Notes on various control possibilities and their applications 1 (black) 3 (yellow) UB +26 VDC 4.7 k PWM/LIN RE typ. 44 k 0 V to 10 V + PWM U - 10 k The blower speed is determined by the input (pin 3, 4) that gives the higher speed. 12 V Speed setting PWM 5 Hz - 100 kHz 100 % PWM -> n=max 15 % PWM -> n=min 0 % PWM -> Standby Speed setting with potentiometer Full speed Speed setting 0 V - 10 V 10 V -> n=max 1,5 V -> n=min 0 V -> Standby U Standby threshold UB 32 V Switch on: typ. 1.5 V off: typ. 1 V Full speed 21 V (orange) INVLIN RE typ. 100 k 6 (white) Diagnostic output 0.05 k 5 (blue) LOWER 47 k 2 (brown) + UB Diagnostic output Operation: output level low (U = 0 V) Rotor locked or overtemperature or overvoltage/undervoltage: output level high (U = UB - 2 V) Imax = 50 mA Collective fault signal possible Customer circuit U Motor stops Switch-on threshold Motor turns 21 V 56 4 Standby 32 V Speed setting: 21 V -> n=min 0 V -> n=max UB -> Standby Speed - lower Input UB -> n/2 open -> n Connection GND Fan 57 Technical parameters & scope High standards for all ebm-papst products Here at ebm-papst, we constantly strive to further improve our products in order to be able to offer you the best possible product for your application. Careful monitoring of the market ensures that technical innovations are reflected in the improvements of our products. Based on the technical parameters listed below and the ambience you want our product to operate in, we here at ebm-papst can always work out the best solution for your specific application. General performance parameters Service life Any deviations from the technical data and parameters described here The service life of ebm-papst automotive products depends on: are listed on the product-specific data sheet. - The service life of the bearing system Type of protection The service life of the bearing system depends mainly on the thermal load The type of protection is specified in the product-specific data sheets. on the bearing. Insulation class The majority of our products use maintenance-free ball bearings for The insulation class is specified in the product-specific data sheets. any mounting position possible. Mounting position The service life L10 of the ball bearings can be taken as approx. 40,000 The mounting position is specified in the product-specific data sheets. operating hours at an ambient temperature of 40 C, yet this estimate can vary according to the actual ambient conditions. Condensate discharge holes Information on the condensate discharge holes is provided in the We will gladly provide you with a lifetime calculation taking into account product-specific data sheets. your specific operating conditions. Mode of operation Motor protection / thermal protection The mode of operation is specified in the product-specific data sheets. Information on motor protection and thermal protection is provided in the product-specific data sheets. Protection class The protection class is specified in the product-specific data sheets. Depending on motor type and field of application, the following protective features are realised: - Thermal overload protection (TOP), in-circuit - PTC/NTC with electronic diagnostics - Current limitation via electronics 58 Left: Endurance test room Middle: Shock test Right: Chamber test rig Mechanical strain / performance parameters Legal and normative directives All ebm-papst products are subjected to comprehensive tests complying The products described in this catalogue are designed, developed and with the normative specifications. In addition to this, the tests also reflect produced in keeping with the standards in place for the relevant product the vast experience and expertise of ebm-papst. and, if known, the conditions governing the relevant fields of application. Vibration test Standards Vibration tests are carried out in compliance with Information on standards is provided in the product-specific data sheets. - Vibration test in operation according to DIN IEC 68, parts 2-6 - Vibration test at standstill according to DIN IEC 68, parts 2-6 EMC Information on EMC standards is provided in the product-specific data Shock load sheets. Shock load tests are carried out in compliance with Complying with the EMC standards has to be established on the final - Shock load according to DIN IEC 68, parts 2-27 appliance, as different mounting situations can result in changed EMC properties. Balancing quality Testing the balancing quality is carried out in compliance with Approvals - Residual imbalance according to DIN ISO 1940 In case you require a specific approval for your ebm-papst automotive - Standard balancing quality level G 6.3 product (e1, UL, etc.) please let us know. Should you require a higher balancing quality level for your specific Most of our products can be supplied with the relevant approval. application, please let us know and specify this when ordering your Information on existing approvals is provided in the product-specific product. data sheets. Chemo-physical strain / performance parameters Air performance measurements Should you have questions about chemo-physical strain, please direct All air performance measurements are carried out on suction side and on them to your ebm-papst contact. chamber test beds conforming to the specifications as per ISO 5801 and DIN 24163. The fans under test are installed in the measuring chamber at Fields of application, industries and applications free air intake and exhaust (installation category A) and are operated at Our products are used in various industries and applications: nominal voltage, with AC also at nominal frequency, and without any Ventilation, air-conditioning and refrigeration technology, clean room additional components such as guard grilles. technology, automotive and rail technology, medical and laboratory tech- As required by the standard, the air performance curves correspond to nology, electronics, computer and office technology, telecommunications, an air density of 1.2 kg/m3. household appliances, heating, machines and plants, drive engineering. Our products are not designed for use in the aviation and aerospace industry! 59 Room for precision noise measuring Measurement conditions for air and noise measurement ebm-papst products are measured under the following conditions: - Axial and diagonal fans in direction of rotation "V" in full nozzle and without guard grille - Backward curved centrifugal fans, free-running and with inlet nozzle - Forward curved single and dual inlet centrifugal fans with housing Noise measurements All noise measurements are carried out in low-reflective test rooms with reverberant floor. Thus the ebm-papst acoustic test chambers meet the requirements of precision class 1 according to DIN EN ISO 3745. For noise measurement, the fans being tested are placed in a reverberant wall and operated at nominal voltage (for AC, also at nominal frequency) without additional attachments such as the guard grille. Sound pressure level and sound level All acoustic values are established according to ISO 13347, DIN 45635 and ISO 3744/3745 to accuracy class 2 and given in A-rated form. When the sound pressure level (Lp) is measured, the microphone is on the intake side of the fan being tested, usually at a distance of 1 m on the fan axis. To measure the sound power level (Lw), 10 microphones are distributed over an enveloping surface on the intake side of the fan being tested (see graphic). The sound power level measured can be roughly calculated 1,5d from the sound pressure level by adding 7 dB. D Measuring configuration as per ISO 13347-3 respectively DIN 45635-38: 10 measuring points dD h = 1,5d ... 4,5d h 3d Measurement area S = 6d2 + 7d (h + 1,5d) 2d 60 pressure level of a fan is approximately 75 dB(A). The level increase measured from the diagram is 9 dB. Thus the overall sound level of the installation can be expected to be 84 dB(A). 15 10 9 Example: 8 A3G800 axial fans are on a condenser. According to the data sheet, the sound 5 the noise values specified in the data sheet. This is shown in the diagram opposite. 0 The noise characteristics of multiple identical fans can be determined in advance based on [dB] [dB(A)] Adding 2 noise sources with the same level results in a level increase of approx. 3 dB. Increase in sound pressure / sound power level Combined level of multiple same-level sound sources 1 2 3 4 5 6 7 8 9 10 15 20 25 ating point and an axial fan A3G710 with 71 dB(A) in a ventilation unit. The level difference is 4 dB. The level increase can now be read in the diagram as approx. 1.5 dB. This means that the overall sound level of the unit can be expected to be 76.5 dB(A). 3 2 1,5 Example: There is an axial fan A3G800 with a sound pressure level of 75 dB(A) at the oper- 1 levels given in the data sheet. This is shown in the diagram opposite. 0 The acoustic performance of two different fans can be predetermined based on the sound Increase in sound pressure / sound power level Combined level of two different-level sound sources [dB] [dB(A)] Number of sources of sound with identical level 0 4 8 12 16 20 Sound power level is independent of distance to the sound source. In contrast to this, sound -10 pressure level decreases the further away the noise source is. The adjacent diagram shows 0 [dB] [dB(A)] Distance laws 24 [dB] [dB(A)] Difference in level with two sources of sound the decrease in level under far sound field conditions. Far sound field conditions apply when- decreases by 6 dB. In the near field of the fan, other correlations apply and the decrease in levels can be considerably smaller. The following example only applies to far sound field conditions and can vary strongly depending on the installation effects: With an axial fan A3G300, a sound pressure level of 65 dB(A) was measured at a distance of 1 m. According to the adjacent diagram, at a distance of 20 m we would get a reduction by -20 -26 -30 vant literature on this complex topic. Per doubling of distance, the level in the far sound field -40 wavelength to be considered. For more information on far sound field, please consult the rele- Decrease in sound pressure level ever the distance between microphone and fan is big when compared to fan diameter and 1 Distance 2 5 10 20 50 100 [m] 26 dB, i.e. a sound pressure level of 39 dB(A). 61 fan agent compact fan agent ebm-papst in Germany motor specialist motor agent Germany ebm-papst Mulfingen GmbH & Co. KG ebm-papst St. Georgen GmbH & Co. KG ebm-papst Landshut GmbH Bachmuhle 2 D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com Hermann-Papst-Strae 1 D-78112 St. Georgen Phone +49 7724 81-0 Fax +49 7724 81-1309 info2@de.ebmpapst.com Hofmark-Aich-Strae 25 D-84030 Landshut Phone +49 871 707-0 Fax +49 871 707-465 info3@de.ebmpapst.com www.ebmpapst.com www.ebmpapst.com www.ebmpapst.com 62 Berlin Dipl.-Ing. (TH) Jens Duchow Handelstrae 7 D-16341 Panketal Phone +49 30 944149-62 Fax +49 30 944149-63 Jens.Duchow@de.ebmpapst.com Heilbronn / Heidelberg Dipl.-Ing. Mark Gartner Gehrweg 12 D-74199 Unterheinriet Phone +49 7130 404569-1 Fax +49 7130 404569-2 Mark.Gartner@de.ebmpapst.com Bielefeld Dipl.-Ing. (FH) Wolf-Jurgen Weber Niehausweg 13 D-33739 Bielefeld Phone +49 5206 91732-31 Fax +49 5206 91732-35 Wolf-Juergen.Weber@de.ebmpapst.com Kassel Dipl.-Ing. (FH) Ralph Bruck Hoherainstrae 3 b D-35075 Gladenbach Phone +49 6462 4071-10 Fax +49 6462 4071-11 Ralph.Brueck@de.ebmpapst.com Dortmund Dipl.-Ing. (FH) Hans-Joachim Pundt Auf den Steinern 3 D-59519 Mohnesee-Vollinghausen Phone +49 2925 800-407 Fax +49 2925 800-408 Hans-Joachim.Pundt@de.ebmpapst.com Koblenz Winfried Schaefer Hinter der Kirch 10 D-56767 Uersfeld Phone +49 2657 16-96 Fax +49 2657 16-76 Winfried.Schaefer@de.ebmpapst.com Frankfurt Dipl.-Ing. Christian Kleffmann Dr.-Hermann-Krause-Strae 23 D-63452 Hanau Phone +49 6181 1898-12 Fax +49 6181 1898-13 Christian.Kleffmann@de.ebmpapst.com Munich Dipl.-Wirt.-Ing. (FH) Jens Peter Landsbergerstrae 14 D-86932 Purgen Phone +49 8196 99877-54 Fax +49 8196 99877-55 Jens.Peter@de.ebmpapst.com Halle Dipl.-Ing. (TU) Michael Hanning Lercheneck 4 D-06198 Salzatal / OT Lieskau Phone +49 345 55124-56 Fax +49 345 55124-57 Michael.Hanning@de.ebmpapst.com Nuremberg Dipl.-Wirt.-Ing. (FH) Axel Resch Steinsfeldstrae 80 D-74626 Bretzfeld Phone +49 7946 94401-02 Fax +49 7946 94401-03 Axel.Resch@de.ebmpapst.com Hamburg Ingenieurburo Breuell GmbH Ing. Dirk Kahl Elektroingenieur Grutzmuhlenweg 48 D-22339 Hamburg Phone +49 40 538092-19 Fax +49 40 538092-84 Dirk.Kahl@de.ebmpapst.com Offenburg Dipl.-Ing. (FH) Ralf Braun Hubeneck 21 D-77704 Oberkirch Phone +49 7802 9822-52 Fax +49 7802 9822-53 Ralf.Braun@de.ebmpapst.com Stuttgart Dipl.-Ing. (FH) Rudi Weinmann Hindenburgstrae 100/1 D-73207 Plochingen Phone +49 7153 9289-80 Fax +49 7153 9289-81 Rudi.Weinmann@de.ebmpapst.com Ulm M.Sc. Reinhard Sommerreier Am Silbermannpark 10 D-86161 Augsburg Phone +49 821 6610-7023 Fax +49 821 6610-7024 Reinhard.Sommerreisser@de.ebmpapst.com Distributors Frankfurt R.E.D. Handelsgesellschaft mbH Gutenbergstrae 3 D-63110 Rodgau - Jugesheim Phone +49 6106 841-0 Fax +49 6106 841-111 info@red-elektromechanik.de www.red-elektromechanik.de Hamburg Breuell + Hilgenfeldt GmbH Grutzmuhlenweg 48 D-22339 Hamburg Phone +49 40 538092-20 Fax +49 40 538092-84 info@breuell-hilgenfeldt.de Munich A. Schweiger GmbH Ohmstrae 1 D-82054 Sauerlach Phone +49 8104 897-0 Fax +49 8104 897-90 info@schweiger-gmbh.de www.schweiger-gmbh.com (1 to 5 pieces) North Breuell + Hilgenfeldt GmbH Grutzmuhlenweg 48 D-22339 Hamburg Phone +49 40 538092-20 Fax +49 40 538092-84 ebmpapst@breuell-hilgenfeldt.de South HDS Ventilatoren Vertriebs GmbH Glaswiesenstrae 1 D-74677 Dorzbach Phone +49 7937 80355-20 Fax +49 7937 80355-25 info@hds-gmbh.net www.hds-gmbh.net ebm-papst in Europe Europe Austria ebm-papst Motoren & Ventilatoren GmbH Straubingstrae 17 A-4030 Linz Phone +43 732 321150-0 Fax +43 732 321150-20 info@at.ebmpapst.com www.ebmpapst.at Belarus ebm-papst Bel AgmbH P.O. Box 117 BY-220138 Minsk Phone +375 17 3851556 Fax +375 17 3851556 info@by.ebmpapst.com www.ebmpapst.by Belgium ebm-papst Benelux B.V. Sales office Belgium-Luxemburg Romeinsestraat 6/0101 Research Park Haasrode B-3001 Heverlee-Leuven Phone +32 16 396-200 Fax +32 16 396-220 info@be.ebmpapst.com www.ebmpapst.be Bulgaria ebm-papst Romania S.R.L. Str. Tarnavei No. 20 RO-500327 Brasov Phone +40 268 331859 Fax +40 268 312805 dudasludovic@xnet.ro Croatia ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 office@hu.ebmpapst.com Czech Republic / Slovakia ebm-papst CZ s.r.o. Katanova 34a CZ-620 00 Brno Phone +420 544 502-411 Fax +420 547 232-622 info@ebmpapst.cz www.ebmpapst.cz Denmark ebm-papst Denmark ApS Vallensbaekvej 21 DK-2605 Brondby Phone +45 43 631111 Fax +45 43 630505 mail@dk.ebmpapst.com www.ebmpapst.dk Estonia ebm-papst Oy, Eesti Filiaal Kesk tee 13 Aaviku kula, Juri Tehnopark EST-75301 Rae Vald, Harjumaa Phone +372 65569-78 Fax +372 65569-79 www.ebmpapst.ee Finland ebm-papst Oy Puistotie 1 FIN-02760 Espoo Phone +358 9 887022-0 Fax +358 9 887022-13 mailbox@ebmpapst.fi www.ebmpapst.fi France ebm-papst sarl ZI Nord - rue A. Mohler BP 62 F-67212 Obernai Cedex Phone +33 820 326266 Fax +33 3 88673883 info@ebmpapst.fr www.ebmpapst.fr Greece Helcoma Th. Rotas & Co OE Davaki 65 GR-17672 Kallithea-Attiki Phone +30 210 9513-705 Fax +30 210 9513-490 contact@helcoma.gr www.helcoma.gr Hungary ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 office@hu.ebmpapst.com Iceland RJ Engineers Stangarhyl 1a IS-110 Reykjavik Phone +354 567 8030 Fax +354 567 8015 rj@rj.is www.rj.is Ireland ebm-papst UK Ltd. Chelmsford Business Park GB-Chelmsford Essex CM2 5EZ Phone +44 1245 468555 Fax +44 1245 466336 sales@uk.ebmpapst.com www.ebmpapst.co.uk AuBren Limited Portlaoise Business & Technology Park Mountrath Road IRL-Portlaoise, Co. Laois Phone +353 57 8664343 Fax +353 57 8664346 sales@ie.aubren.com www.aubren.com Italy ebm-papst Srl Via Cornaggia 108 I-22076 Mozzate (Co) Phone +39 0331 836201 Fax +39 0331 821510 info@it.ebmpapst.com www.ebmpapst.it Macedonia ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 office@hu.ebmpapst.com 63 fan agent compact fan agent ebm-papst in Europe motor specialist motor agent Netherlands ebm-papst Benelux B.V. Engelseweg 127 NL-5705 AC Helmond Phone +31 492 502-900 Fax +31 492 502-950 verkoop@nl.ebmpapst.com www.ebmpapst.nl Russia ebm-papst Ural GmbH Posadskaja-Strasse, 23(E), 3 RU-620102 Ekaterinburg Phone +7 343 2338000 Fax +7 343 2337788 Konstantin.Molokov@ru.ebmpapst.com www.ebmpapst.ur.ru Switzerland ebm-papst AG Rutisbergstrasse 1 CH-8156 Oberhasli Phone +41 44 73220-70 Fax +41 44 73220-77 verkauf@ebmpapst.ch www.ebmpapst.ch Norway ebm-papst AS P.B. 173 Holmlia N-1203 Oslo Phone +47 22 763340 Fax +47 22 619173 mailbox@ebmpapst.no www.ebmpapst.no ebm-papst Rus GmbH proezd 4529, vladenie 5, stroenie 1 RU-141000 Mytistschi, Oblast Moskau Phone +7 495 9807524 Fax +7 495 5140924 info@ebmpapst.ru www.ebmpapst.ru Turkey Akantel Elektronik San. Tic. LTD. Sti. Ataturk Organize Sanayi Bolgesi 10007 SK. No.:6 TR-35620 Cigli-Izmir Phone +90 232 3282090 Fax +90 232 3280270 akantel@akantel.com.tr www.ebmpapst.com.tr Poland ebm-papst Polska Sp. z o.o. ul. Annopol 4A PL-03236 Warszawa Phone +48 22 6757819 Fax +48 22 6769587 office@ebmpapst.pl www.ebmpapst.pl Portugal ebm-papst (Portugal), Lda. Centro Empresarial de Alverca Rua de Adarse, Vale D'Ervas Corpo D / Fraccao 3 P-2615-178 Alverca do Ribatejo Phone +351 218 394 880 Fax +351 218 394 759 info@pt.ebmpapst.com www.ebmpapst.pt Romania ebm-papst Romania S.R.L. Str. Tarnavei Nr. 20 RO-500327 Brasov Phone +40 268 331859 Fax +40 268 312805 dudasludovic@xnet.ro 64 Serbia & Montenegro ebm-papst Industries Kft. Ezred u. 2. H-1044 Budapest Phone +36 1 8722-190 Fax +36 1 8722-194 office@hu.ebmpapst.com Spain ebm-papst Iberica S.L. Avda. del Sistema Solar, 29 E-28830 San Fernando de Henares (Madrid) Phone +34 91 6780894 Fax +34 91 6781530 ventas@ebmpapst.es www.ebmpapst.es Sweden ebm-papst AB Aggelundavagen 2 S-17562 Jarfalla Phone +46 10 4544400 Fax +46 8 362306 info@ebmpapst.se www.ebmpapst.se Ukraine ebm-papst Ukraine LLC Lepse Boulevard, 4, Building 21 UA-03067 Kiev Phone +38 044 2063091 Fax +38 044 2063091 mail@ebmpapst.ua www.ebmpapst.ua United Kingdom ebm-papst UK Ltd. Chelmsford Business Park GB-Chelmsford Essex CM2 5EZ Phone +44 1245 468555 Fax +44 1245 466336 sales@uk.ebmpapst.com www.ebmpapst.co.uk ebm-papst Automotive & Drives (UK) Ltd. The Smithy Fidlers Lane GB-East Ilsley, Berkshire RG20 7LG Phone +44 1635 2811-11 Fax +44 1635 2811-61 A&Dsales@uk.ebmpapst.com www.ebmpapst-ad.com ebm-papst in America and Africa America Argentina ebm-papst de Argentina S.A. Hernandarias 148 Lomas del Mirador Pcia. de Buenos Aires (1752) Phone +54 11 46576135 Fax +54 11 46572092 ventas@ar.ebmpapst.com www.ebmpapst.com.ar Brazil ebm-papst Motores Ventiladores Ltda. Av. Jose Giorgi, 301 Galpoes B6+B7 Condominio Logical Center BR-06707-100 Cotia - Sao Paulo Phone +55 11 4613-8700 Fax +55 11 4777-1456 vendas@br.ebmpapst.com www.ebmpapst.com.br USA ebm-papst Inc. P.O. Box 4009 100 Hyde Road USA-Farmington, CT 06034 Phone +1 860 674-1515 Fax +1 860 674-8536 sales@us.ebmpapst.com www.ebmpapst.us ebm-papst Automotive & Drives, Inc. 3200 Greenfield, Suite 255 USA-Dearborn, MI 48120 Phone +1 313 406-8080 Fax +1 313 406-8081 automotive@us.ebmpapst.com www.ebmpapst-automotive.us Africa South Africa ebm-papst South Africa (Pty) Ltd. P.O. Box 3124 1119 Yacht Avenue ZA-2040 Honeydew Phone +27 11 794-3434 Fax +27 11 794-5020 info@za.ebmpapst.com www.ebmpapst.co.za Canada ebm-papst Canada Inc. 1800 Ironstone Manor, Unit 2 CDN-Pickering, Ontario, L1W3J9 Phone +1 905 420-3533 Fax +1 905 420-3772 sales@ca.ebmpapst.com www.ebmpapst.ca Mexico ebm Industrial S. de R.L. de C.V. Paseo de Tamarindos 400-A-5to Piso Col. Bosques de las Lomas MEX-Mexico 05120, D.F. Phone +52 55 3300-5144 Fax +52 55 3300-5243 sales@mx.ebmpapst.com www.ebmpapst.com.mx 65 fan agent compact fan agent ebm-papst in Asia and Australia motor specialist motor agent Asia China ebm-papst Ventilator (Shanghai) Co., Ltd. No. 418, Huajing Road WaiGaoQiao Free Trade Zone No. 2001, Yang Gao (N) Road VRC-200131 Shanghai, P.R. of China Phone +86 21 5046-0183 Fax +86 21 5046-1119 sales@cn.ebmpapst.com www.ebmpapst.com.cn Hong Kong ebm-papst Hong Kong Ltd. Unit No. 13,9 / F Technology Park, 18 On Lai Street Siu Lek Yuen, Shatin N.T. Hong Kong - P.R. of China Phone +852 2145-8678 Fax +852 2145-7678 info@hk.ebmpapst.com India ebm-papst India Pvt. Ltd. 26/3, G.N.T. Road, Erukkencherry IND-Chennai-600118 Phone +91 44 25372556 Fax +91 44 25371149 sales@in.ebmpapst.com www.ebmpapst.in Indonesia ebm-papst Indonesia Representative Office German Centre, 4th Floor, Suite 4470 Jl. Kapt. Subijono Dj. Bumi Serpong Damai RI-15321 Tangerang Phone +62 21 5376250 Fax +62 21 5388305 salesdept@id.ebmpapst.com Israel Polak Bros. Import Agencies Ltd. 9 Hamefalsim Street IL-Kiryat Arie, Petach-Tikva 49514 Phone +972 3 9100300 Fax +972 3 5796679 polak@polak.co.il www.polak.co.il 66 Japan ebm-papst Industries Japan K.K. 12th Floor, Benex S-3 Bldg. 3-20-8 Shinyokohama, Kohoku-ku J-222-0033 Yokohama Phone +81 45 47057-51 Fax +81 45 47057-52 info@jp.ebmpapst.com www.ebmpapst.jp Thailand ebm-papst Thailand Co., Ltd. 99/9 Moo 2, Central Chaengwattana Tower 14th Floor, Room 1402 Chaengwattana Road Bangtarad, Pakkret THA-11120 Nonthaburi Phone +66 2 8353785-7 Fax +66 2 8353788 salesdept@th.ebmpapst.com Korea ebm-papst Korea Co. Ltd. 6F, Trutec Bldg. B 6-2, Digital Media City (DMC) Sangam-Dong, Mapo-Gu ROK-Seoul 121-270 Phone +82 2 366213-24 Fax +82 2 366213-26 info@kr.ebmpapst.com www.ebmpapst.co.kr United Arab Emirates ebm-papst Middle East FZE PO Box 17755 Jebel Ali Free Zone / FZS1 / AP05 UAE-Dubai Phone +971 4 88608-26 Fax +971 4 88608-27 info@ae.ebmpapst.com www.ebmpapst.ae Malaysia ebm-papst Malaysia Representative Office Unit 12-2, Jalan USJ Sentral 3 Persiaran Subang, Selangor Darul Ehsan MAL-47600 Subang Jaya Phone +60 3 8024-1680 Fax +60 3 8024-8718 salesdept@my.ebmpapst.com Singapore ebm-papst SEA Pte. Ltd. No. 23 Ubi Road 4 #06-00 Olympia Industrial Building SGP-Singapore 408620 Phone +65 65513789 Fax +65 68428439 salesdept@sg.ebmpapst.com Taiwan ETECO Engineering & Trading Corp. 10F-I, No. 92, Teh-Wei Str. RC-Tsow-Inn District, Kaohsiung Phone +886 7 557-4268 Fax +886 7 557-2788 eteco@ms22.hinet.net www.ebmpapst.com.tw Vietnam ebm-papst Vietnam Representative Office Room #102, 25 Nguyen Van Thu Street District 1 VN-Ho Chi Minh City Phone +84 8 39104099 Fax +84 8 39103970 linh.nguyen@vn.ebmpapst.com Australia Australia ebm-papst A&NZ Pty Ltd. 10 Oxford Road AUS-Laverton North, Victoria, 3026 Phone +61 3 9360-6400 Fax +61 3 9360-6464 sales@ebmpapst.com.au www.ebmpapst.com.au New Zealand ebm-papst A&NZ Pty Ltd. 102 Henderson Valley Road NZ-Henderson, Auckland 1230 Phone +64 9 837-1884 Fax +64 9 837-1899 sales@ebmpapst.com.au www.ebmpapst.com.au 67 37659-7-8811 * 2012-09 * KD-1' Printed in Germany ebm-papst Mulfingen GmbH & Co. KG Bachmuhle 2 D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com