PolySwitch(R) PTC Devices PRODUCT: TRF600-160-1 DOCUMENT: SCD26322 REV LETTER: E REV DATE: JULY 26, 2016 PAGE NO.: 1 OF 2 Overcurrent Protection Device Specification Status: Released Maximum Operating Voltage: 250VDC Fault Ratings at 20C: 250VRMS, 3A, 10 applications 600VRMS, 60A, 1 application Additional Info at 20C: * Resistance matched: N/A * Lightning withstand: GR-10891.0 kV, 10/1000s, with 13 ohm load * Helps equipment comply to Telcordia GR-1089 Lead Material: 22 AWG Sn-Plated Copper (0.64 mm [0.025"] nominal diameter) External Coating Material: Cured, flame retardant epoxy polymer, meeting UL94 V-0 requirements Marking: TABLE I. DIMENSIONS: A B MIN MAX MIN MAX mm: -16.0 -12.6 in*: -(0.63) -(0.50) * Rounded off approximation C MIN --- D MAX 6.0 (0.24) MIN 19.0 (0.75) MAX --- E NOM 5.0 (0.20) F MAX 10.0 (0.39) TABLE II. PERFORMANCE RATINGS @ 20C (as measured in Loranger P/N 02901-032-6218A): HOLD TRIP CURRENT CURRENT (A) (A) RESISTANCE () R MIN R MAX R1 MAX* 0.160 0.320 4.0 10.0 18.0 *Post Trip Resistance measured after one hour. TIME TO TRIP(Sec) @ 1A TYP 7.5 MAX 18.0 OPERATING TEMPERATURE (C) MIN MAX -40 85 TRIPPED POWER DISSIPATION (W) @ 250VDC TYP MAX 1.7 2.2 TABLE III. APPLICABLE PART DESCRIPTIONS: PART DESCRIPTION TRF600-160-1 Agency Recognitions: Reference Documents: Precedence: Effectivity: CAUTION: PACKAGING TYPE Bulk NOTE N/A UL (File #E74889), CSA (File #1026908), TUV PS300, Telcordia GR-1089 This specification takes precedence over documents referenced herein. Reference documents shall be the issue in effect on the date of invitation for bid. Operation beyond the rated voltage or current may result in rupture, electrical arcing or flame. Materials Information ROHS Compliant ELV Compliant (c) 2016 Littelfuse,Inc Specifications are subject to change without notice. Revised July 26, 2016 Pb-Free Littelfuse.com PolySwitch(R) PTC Devices Overcurrent Protection Device PRODUCT: TRF600-160-1 DOCUMENT: SCD26322 REV LETTER: E REV DATE: JULY 26, 2016 PAGE NO.: 2 OF 2 Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability of and test each product selected for their own applications. Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, military, aerospace, medical, lifesaving, life-sustaining or nuclear facility applications, devices intended for surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse product documentation. Warranties granted by Littelfuse shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse documentation. Littelfuse shall not be liable for any claims or damages arising out of products used in applications not expressly intended by Littelfuse as set forth in applicable Littelfuse documentation. The sale and use of Littelfuse products is subject to Littelfuse Terms and Conditions of Sale, unless otherwise agreed by Littelfuse. (c) 2016 Littelfuse,Inc Specifications are subject to change without notice. Revised July 26, 2016 Littelfuse.com