Data Sheet
10/15-4.01 EN
Field
Multi Vision®
Four-wire add on unit for Pressure transmitter
Serie 2000T
IT
2-wire transmitter with integrated power supply
Output signal 0...20 mA or 4...20 mA
Power supply: 24 V or 230 V
HART® communication at the transmitter is also
possible
2
Multi Vision®10/15-4.01 EN
Four-wire add on unit for Pressure transmitter Serie 2000T
The four-wire add-on unit for pressure transmitter 2000T
provides a power supply device that is built right onto the
transmitter. This unit is equipped with a separator between
power supply and output signal. This construction enables using
the two-wire transmitter as a four-wire transmitter with the option
of either 24 V or 230 V power supplies. Output signal can be
selected: 0...20 mA or 4...20 mA. HART communication direct to
the transmitter is possible. The add-on unit is mounted to the
transmitter at the factory.
Technical data
Input
4...20 mA
Supply voltage
min. 14V at 20 mA
Output
0(4)...20 mA (selectable)
Characteristic
increasing, linear
Current limitation
approx. 25 mA
Maximum load
750 W
Ripple
max. 1 % v. input at max. load
Power supply
AC 230V (+6 % / -10 %):
47 ... 63 Hz;
max. power consumption: 6 VA
DC 24 V (18 ... 32 V):Allowable ripple is 2.5 Vpp within
above-mentioned limits;
max. power consumption:
3 W
Deviation from characteristics
max. 0.15 % v. input
Time constant t90
max. 30 ms
Influence due to
Ambient temperature 0.1% / 10K
Load 0.1%
when changing from 0 % to 100 %
Power supply 0.1% during a 10% change
Galvanic separation between
power supply and input
power supply and output
Insulation voltage according to DIN EN 61 010
AC 250 V
Pollution degree
2
Overvoltage category
II.
Test voltage
UC: 1.5 kV
AC: 2.3 kV
EMC tested according to
DIN EN 61 326
Ambient conditions
Operating temperature -20 °C - +80 °C
Storage temperature -50 °C - +85 °C
Condensation allowed
Housing
Protection class (DIN40040) IP54
Material Cast aluminium,
epoxy resin coat
Dimensions H x W x D: 125 x 80 x 60 mm
Weight
approx. 0.7 kg
Colour
RAL 7032,
Smooth surface
3
Multi Vision®10/15-4.01 EN
Four-wire add on unit for Pressure transmitter Serie 2000T
Dimensional drawings
~58
124
~125
~30
~125
~85
a
b
125
30
173
85
125
58
35 108
Dimensions „a“ and „b“ are dependent on range and process
connection:
Process connection
Ranges:
60 mbar
400 mbar
Ranges:
2.5 bar
abab
1/2-14NPT male thread 142 168 147 173
1/2-14NPT female thread
with a range of 600 bar
132 158 143
146
169
172
Spigot DIN EN 837-1 G 1/2 B 141 167 147 173
Spigot DIN EN 837-1 G 1/2 B
(HP) for convex seal 152 178 157 183
Front bonded diaphragm −−147 172
For ball valve connection −−244 270
1 Transmitter
2 Electrical connection
3 Four-wire add-on unit
A radius of 70 mm free
space is required to swing
open the local key unit cover
A radius of 70 mm free
space is required to swing
open the local key unit cover
3
1
2
2
3
1
10/15-4.01 EN Rev A
The IndustrialIT wordmark and all mentioned
product names in the form XXXXXXIT are registered
or pending trademarks of ABB.
ABB has Sales & Customer Support
expertise in over 100 countries worldwide.
www.abb.com
ABB Ltd.
Howard Road, St. Neots
Cambridgeshire, PE19 8EU
UK
Phone: +44(0)1480 475321
Fax: +44(0)1480 217948
The Company’s policy is one of continuous product
improvement and the right is reserved to modify the
information contained herein without notice.
Printed in the Fed. Rep. of Germany (01.03)
© ABB 2003
ABB Inc.
125 E. County Line Road
Warminster, PA 18974
USA
Phone: +1 215 674 6000
Fax: +1 215 674 7183
ABB Automation Products GmbH
Schillerstraße 72
32425 Minden
GERMANY
Phone: +49 571 830-0
Fax: +49 571 830-1470
Ordering information
The following catalog numbers are appended to the catalog
number of each respective transmitter. The transmitter 2010TD/
TA fitted with the four-wire add-on unit must use the DIN housing
with electr. connection M 20x1.5 (amplifier housing ordering
code M). The transmitter 2020TG/TA must use the barrel type
housing with electr. connection M 20x1.5 (amplifier housing
ordering code E).
1) see ordering no. of amplifier housing on the transmitter
2) When plug connection on add-on unit required, please use
code no. 273.
It is also necessary to specify the plug connector on the
transmitter.
Ordering information for four-wire add-on unit
Ordering number EUR LZ
Amplifier housing accessories
Power supply / output signal
DC 24 V / 0…20 mA
DC 24 V / 4…20 mA
AC 230 V / 0…20 mA
AC 230 V / 4…20 mA
5D1
5D3
5D2
5D4
Electrical connection of the add-on unit
Threaded cable gland M 20x1.51)
Plug Han 8U (only in conjunction with DC 24 V power supply) 1)
Plug Han 7D (only in conjunction with DC 24 V power supply) 2) 273