ECI motor. ECl-63.XX-K1 - Highly dynamic 3-phase internal rotor motor with EC technology - Low cogging torque - Robust, noise-optimized ball bearing system for a long service life - High efficiency and high power density realized in a compact design - Basic motor with electronic module K1 for operation with external control electronics - Mechanical design and interfaces designed for modular flexibility - Protection class IP 40 / IP 54 and connection by connector system Nominal data Type Nominal voltage (UJ voe Nominal speed (n,r rpm 24 48 24 48 48 4 000 Nominal torque (M,)** mNm 360 360 670 670 800 880 Nominal current (I,)** A 8.50 4.50 14.0 6.50 17.6 8.50 Nominal output power (P,)** w Starting torque (M..,) mNm 150 150 280 280 335 370 1 800 1 800 3 300 3 300 5 300 4 400 Permissible peak current (lmJ*** A 55 30 95 45 150 57 Speed at no-load operation (n,) rpm 5 800 6 800 5 900 5 900 6100 6 000 No-load current (I,) A 0.50 0.30 0.70 0.32 1.30 0.45 Recommended speed control range rpm Rotor moment of inertia (J,) kgm' x1o-' 19 19 38 38 57 57 Motor constant (KJ mVs/rad 41.4 73.3 40.4 83.8 40.4 83.8 Connection resistance (f\) fl 0.14 0.42 0.08 0.24 0.04 0.15 Connection inductance (L,,) mH 0.26 0.88 0.14 0.57 0.09 0.33 0 ... 5 000 To be implemented via the control electronics Overload protection :g 24 Permissible ambient temperature range (Tu) oc Weight kg Order no. (wire interface)* IP 40 9326320103 9326320105 9326340103 9326340105 9326360106 9326360108 Order No. (connector interface)* IP 54 9326320100 9326320102 9326340100 9326340102 9326360102 Subject to alterations Classification of protection class refers to installed state wtth sealing on the flange side Toe wave geometry for the IP54 version differs from the illustrated drawing ** AtTu max. 40 C *** Penmissible time for peak current max. 1 sec. - to be repeated only after complete cool down 16 . 0 ... +40 0.90 0.90 1.20 1.20 1.50 1.50 ebmpapst Crown gearheads. EtaCrown (R) 75 - Maximum safety in design and operation, as well as optimal vandalism protection; no automatic lock due to high efficiency of the crown wheel technology - Space-saving installation due to zero offset axle and symmetrical structure - Flexible application possibilities with various optional shaft outlets and available shaft geometries - Wide reduction range by means of upstream / downstream planetary stage - High radial loads due to double ball bearing in the output shaft Image of 2-stage gearhead Nominal data Gearheads Reduction ratio No. of stages - 4.10 Short-term torque (M""") rpm Nm Nm Gear play Permissible operating temperature (T0) oc Rated output torque (M.,,) Operating mode 6.00 15.0 kg Shaft load radial/ axial N Service life h 0.90 6 000 5.00 12.5 0.55 ... 1.1 -20 ... +80 S1 IP 50 Protection class Weight 6.70 10.1 20.3 33.3 60.0 113 10.0 25.0 10.0 25.0 2 Efficiency Max. input speed (n,) EtaCrown" 75.2 EtaCrown" 75.1 150/500 Lubrication Installation position 0.9 250/500 5 000 0.81 6 000 2.43 6.08 10.0 25.0 10.0 25.0 0.55 ... 1.1 -20 ... +80 S1 IP 50 1.3 1 100/500 400/500 550/500 800/500 5 000 Maintenance-free grease lubrication for life any 1 300/500 Subject to alterations on request :g 66 ebmpapst