Switches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
RV8H and RV8S Relays & Sockets
840 www.IDEC.com 1705151135
6mm and 14mm Slim Interface Relay
Key features:
Class I, Division 2 and Class I, Zone 2
Hazardous Location options (electromechanical relays only)
Solid State relay versions available
(6mm only)
Only 70mm in height from DIN rail
Gold-plated contacts
(electrical mechanical relays only)
Pre-assembled relay and DIN mount socket
Universal screw terminals (at and phillips) or spring clamp terminals
Universal AC/DC socket with built-in surge suppression and green LED
6A-16A contact rating
(electromechanical relays only)
Lever for easy locking and removal of relay
Operating temperature of -40ºC ~ +70°C (-20°C ~ +60°C for SSR)
RoHS compliant
Electromechanical Screw Terminal Solid State Spring Clamp Terminal
6mm wide 6mm wide
General Specications
Electromechanical Standard/
Hazardous Location C1D2 Solid State
Ratings
Class I, Division 2, Groups A, B, C, D, T4A
Class I, Zone 2 AEx nA nC IIC T4
Class I, Zone 2 Ex nA nC IIC T4 X Gc
UL/c-UL Listed
UL/c-UL Listed,
Number of Poles 1 Pole 1 Pole
Contact Conguration 1C (SPDT) 1A (SPST)
Contact Material AgNi (Au plating) MOSFET, Transistor or Triac
Degree of Protection IP20 IP20
Dielectric
Strength
Between Contact
and Coil 4,000V AC for 1 minute 2,500V AC for 1 minute
Between Pole 1,000V AC for 1 minute -
Vibration
Resistance
Operating Extremes Frequency 10 to 55Hz,
Amplitude 0.5mm (NO contact),
0.2mm (NC contact)
Frequency 10 to 55Hz,
Amplitude 1.0mm
Damage Limits
Shock
Resistance
Operating Extremes NO: 49m/s²
NC: 29.4m/s² 980m/s2
Damage Limits 980m/
Mechanical Life
(no load)
Over 10,000,000 operations
(operation frequency 18,000
operations per hour) -
Operating Temperature -40 to +70°C no freezing
(-40 to +55°C for AD110 and AD220 coil voltages) -20 to +60°C
Operating Humidity 5 to 85% (no condensation) 5 to 85% (no condensation)
Weight (approx.) Screw Terminal: 30g,
Spring Clamp Terminal: 26g
Screw Terminal: 30g,
Spring Clamp Terminal: 26g
Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
841
800-262-IDEC (4332) USA & Canada
RV8H and RV8S
Relays & Sockets
1705151135
RV8 Series 14mm Width
Top View
with
Marking
Plate Screw Terminal Spring Clamp Terminal
Key features:
Class I, Division 2 and Class I, Zone 2 Hazardous Location options
Space-saving 14mm width.
Universal AC/DC socket with surge suppression and green LED Indicator
Gold plated contacts (2-pole model only)
Pre-assembled relay and DIN mount socket
Universal screw terminals (at and Philips) or spring clamp terminals
Only 70 mm in height from DIN rail
Release lever for easy locking and removal of relay
Wide input voltage range: 6 to 240V
High dielectric strength and impulse withstand voltages.
Reverse polarity protected
RoHS compliant
Specications
Number of Poles 1 Pole 2 Pole
Ratings
Class I, Division 2, Groups A, B, C, D, T4
Class I, Zone 2 AEx nA nC IIC T4
Class I, Zone 2 Ex nA nC IIC T4 X Gc
UL/c-UL Listed
Contact Conguration 1C (SPDT) 2C (DPDT)
Contact Material AgNi AgNi (Au-plated)
Degree of Protection IP20 IP20
Dielectric
strength
Between contact and coil 5,000V AC for 1 minute
Between contacts of the
same pole 1,000V AC for 1 minute
Between contact sets -2,500V AC for 1 minute
Vibration
Resistance
Operating extremes Frequency 10 to 55Hz,
Amplitude 0.75mm (NO contact), 0.175mm (NC contact)
Frequency 10 to 55Hz,
Amplitude 0.75mm (NO contact), 0.1mm (NC contact)
Damage limits
Shock
Resistance
Operating extremes NO: 98m/s² NC: 24.5m/s²
Damage limits 980m/s² 980m/s²
Electrical Life - Screw terminal AC load:30,000 operations minimum
(250V AC, 16A resistive load, operation frequency 360 operation per
hour)
AC load:100,000 operations minimum
(250V AC, 8A resistive load, ozperation frequency 360
operation per hour)
Electrical Life - Spring Clamp terminal AC load:30,000 operations minimum
(250V AC, 12A resistive load, operation frequency 360 operation per
hour)
AC load:100,000 operations minimum
(250V AC, 6A resistive load, operation frequency 360
operation per hour)
Mechanical Life (no load) Over 10,000,000 operations
(Operation frequency 18,000 operations per hour)
Over 10,000,000 operations
(Operation frequency 18,000 operations per hour)
Operating Temperature
RV8H-1L1-D6, D9, D12, D18, D24, AD12, AD18, AD24, AD48, AD60,
AD110
: -40 to +70°C (Contact current 12A max, 6A per terminal) no freezing
: -40 to +55°C (Contact current 16A max, 8A per terminal) no freezing
RV8H-2L-D6, D9, D12, D18, D24, AD12, AD18, AD24, AD48,
AD60, AD110
: -40 to +70°C (Contact current 6A max) no freezing
: -40 to +55°C (Contact current 8A max) no freezing
RV8H-1L1- AD220
: -40 to +55°C (Contact current 16A max, 8A per terminal) no freezing
RV8H-2L- AD220
: -40 to +55°C (Contact current 8A max) no freezing
RV8H-1S1-D6, D9, D12, D18, D24, AD12, AD18, AD24, AD48, AD60,
AD110
: -40 to +70°C (Contact current 12A max, 6A per terminal) no freezing
RV8H-2S-D6, D9, D12, D18, D24, AD12, AD18, AD24, AD48,
AD60, AD110
: -40 to +70°C (Contact current 6A max) no freezing
RV8H-1S1- AD220
: -40 to +55°C (Contact current 12A max, 6A per terminal) no freezing
RV8H-2S- AD220
: -40 to +55°C (Contact current 6A max) no freezing
Operating Humidity 5 to 85% (no condensation)
Weight (approx.) Screw Terminal: 52g
Spring Clamp Terminal: 49g
Screw Terminal: 52g
Spring Clamp Terminal: 49g
Switches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
RV8H and RV8S Relays & Sockets
842 www.IDEC.com 1705151135
Part Numbers
6mm Electromechanical Relay
Screw Terminal Spring Clamp Terminal
Input Voltage General Purpose Hazardous Location (C1D2) General Purpose Hazardous Location
(C1D2)
DC
6V RV8H-L-D6 RV8H-L-D6-C1D2 RV8H-S-D6z RV8H-S-D6-C1D2
9V RV8H-L-D9 RV8H-L-D9-C1D2 RV8H-S-D9 RV8H-S-D9-C1D2
12V RV8H-L-D12 RV8H-L-D12-C1D2 RV8H-S-D12 RV8H-S-D12-C1D2
18V RV8H-L-D18 RV8H-L-D18-C1D2 RV8H-S-D18 RV8H-S-D18-C1D2
24V RV8H-L-D24 RV8H-L-D24-C1D2 RV8H-S-D24 RV8H-S-D24-C1D2
AC/
DC
12V RV8H-L-AD12 RV8H-L-AD12-C1D2 RV8H-S-AD12 RV8H-S-AD12-C1D2
18V RV8H-L-AD18 RV8H-L-AD18-C1D2 RV8H-S-AD18 RV8H-S-AD18-C1D2
24V RV8H-L-AD24 RV8H-L-AD24-C1D2 RV8H-S-AD24 RV8H-S-AD24-C1D2
48V RV8H-L-AD48 RV8H-L-AD48-C1D2 RV8H-S-AD48 RV8H-S-AD48-C1D2
60V RV8H-L-AD60 RV8H-L-AD60-C1D2 RV8H-S-AD60 RV8H-S-AD60-C1D2
110V - 125V RV8H-L-AD110 RV8H-L-AD110-C1D2 RV8H-S-AD110 RV8H-S-AD110-C1D2
220V - 240V RV8H-L-AD220 RV8H-L-AD220-C1D2 RV8H-S-AD220 RV8H-S-AD220-C1D2
6mm Solid State Relay
Screw Terminal Spring Clamp Terminal
Input Voltage Output Voltage Part Number Part Number
DC
6V
24V DC, 3.5A RV8S-L-D24-D6 RV8S-S-D24-D6
48V DC, 0.1A RV8S-L-D48-D6 RV8S-S-D48-D6
240V AC, 2A zero cross RV8S-L-A240Z-D6 RV8S-S-A240Z-D6
240V AC, 2A random RV8S-L-A240-D6 RV8S-S-A240-D6
24V
24V DC, 3.5A RV8S-L-D24-D24 RV8S-S-D24-D24
48V DC, 0.1A RV8S-L-D48-D24 RV8S-S-D48-D24
240V AC, 2A zero cross RV8S-L-A240Z-D24 RV8S-S-A240Z-D24
240V AC, 2A random RV8S-L-A240-D24 RV8S-S-A240-D24
AC
120V
24V DC, 3.5A RV8S-L-D24-A120 RV8S-S-D24-A120
48V DC, 0.1A RV8S-L-D48-A120 RV8S-S-D48-A120
240V AC, 2A zero cross RV8S-L-A240Z-A120 RV8S-S-A240Z-A120
240V AC, 2A random RV8S-L-A240-A120 RV8S-S-A240-A120
240V
24V DC, 3.5A RV8S-L-D24-A240 RV8S-S-D24-A240
48V DC, 0.1A RV8S-L-D48-A240 RV8S-S-D48-A240
240V AC, 2A zero cross RV8S-L-A240Z-A240 RV8S-S-A240Z-A240
240V AC, 2A random RV8S-L-A240-A240 RV8S-S-A240-A240
Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
843
800-262-IDEC (4332) USA & Canada
RV8H and RV8S
Relays & Sockets
1705151135
14 mm Electromechanical Relay
Screw Terminal Spring Clamp Terminal
General Purpose Hazardous Location (C1D2) General Purpose Hazardous Location (C1D2)
Input
voltage 1 Pole 2 Pole 1 Pole 2 Pole 1 Pole 2 Pole 1 Pole 2 Pole
DC
6V RV8H-1L1-D6 RV8H-2L-D6 RV8H-1L1-D6-C1D2 RV8H-2L-D6-
C1D2 RV8H-1S1-D6 RV8H-2S-D6 RV8H-1S1-D6-C1D2 RV8H-2S-D6-
C1D2
9V RV8H-1L1-D9 RV8H-2L-D9 RV8H-1L1-D9-C1D2 RV8H-2L-D9-
C1D2 RV8H-1S1-D9 RV8H-2S-D9 RV8H-1S1-D9-C1D2 RV8H-2S-D9-
C1D2
12V RV8H-1L1-D12 RV8H-2L-D12 RV8H-1L1-D12-C1D2 RV8H-2L-D12-
C1D2 RV8H-1S1-D12 RV8H-2S-D12 RV8H-1S1-D12-C1D2 RV8H-2S-D12-
C1D2
18V RV8H-1L1-D18 RV8H-2L-D18 RV8H-1L1-D18-C1D2 RV8H-2L-D18-
C1D2 RV8H-1S1-D18 RV8H-2S-D18 RV8H-1S1-D18-C1D2 RV8H-2S-D18-
C1D2
24V RV8H-1L1-D24 RV8H-2L-D24 RV8H-1L1-D24-C1D2 RV8H-2L-D24-
C1D2 RV8H-1S1-D24 RV8H-2S-D24 RV8H-1S1-D24-C1D2 RV8H-2S-D24-
C1D2
AC/
DC
12V RV8H-1L1-AD12 RV8H-2L-AD12 RV8H-1L1-AD12-C1D2 RV8H-2L-AD12-
C1D2 RV8H-1S1-AD12 RV8H-2S-AD12 RV8H-1S1-AD12-
C1D2
RV8H-2S-AD12-
C1D2
18V RV8H-1L1-AD18 RV8H-2L-AD18 RV8H-1L1-AD18-C1D2 RV8H-2L-AD18-
C1D2 RV8H-1S1-AD18 RV8H-2S-AD18 RV8H-1S1-AD18-
C1D2
RV8H-2S-AD18-
C1D2
24V RV8H-1L1-AD24 RV8H-2L-AD24 RV8H-1L1-AD24-
C1D2 RV8H-2L-AD24-
C1D2 RV8H-1S1-AD24 RV8H-2S-AD24 RV8H-1S1-AD24-
C1D2
RV8H-2S-AD24-
C1D2
48V RV8H-1L1-AD48 RV8H-2L-AD48 RV8H-1L1-AD48-
C1D2 RV8H-2L-AD48-
C1D2 RV8H-1S1-AD48 RV8H-2S-AD48 RV8H-1S1-AD48-
C1D2
RV8H-2S-AD48-
C1D2
60V RV8H-1L1-AD60 RV8H-2L-AD60 RV8H-1L1-AD60-
C1D2 RV8H-2L-AD60-
C1D2 RV8H-1S1-AD60 RV8H-2S-AD60 RV8H-1S1-AD60-
C1D2
RV8H-2S-AD60-
C1D2
110V - 125V RV8H-1L1-AD110 RV8H-2L-AD110 RV8H-1L1-AD110-
C1D2 RV8H-2L-AD110-
C1D2 RV8H-1S1-AD110 RV8H-2S-AD110 RV8H-1S1-AD110-
C1D2
RV8H-2S-AD110-
C1D2
220V - 240V RV8H-1L1-AD220 RV8H-2L-
AD220 RV8H-1L1-AD220-
C1D2 RV8H-2L-AD220-
C1D2 RV8H-1S1-
AD220 RV8H-2S-AD220 RV8H-1S1-AD220-
C1D2
RV8H-2S-AD220-
C1D2
Switches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
RV8H and RV8S Relays & Sockets
844 www.IDEC.com 1705151135
Ratings
6mm Electromechanical Coil Ratings
Rated Voltage
Rated Current
±15% (mA)1
(at 23°C)
Circuit AC Resis-
tance
±15% (Ω)1
(at 23°C)
Circuit DC Resis-
tance
±15% (Ω)1
(at 23°C)
Operating Characteristics Power
Consumption
(W)
Pickup Voltage
(at 23°C)
Dropout
Voltage
(at 23°C)
Maximum
Allowable Voltage
(at 23°C)
DC
6V 35 - 170
90% max 7% min 110%
0.21
9V 18.6 - 485 0.2
12V 14.6 - 820 0.2
18V 11.6 - 1550 0.2
24V 10.6 - 2270 0.25
AC/
DC
12V 15.5 755 800
90% max 7% min 110%
0.2
18V 13.3 1365 1345 0.25
24V 13.7 1730 1790 0.33
48V 4 11880 12230 0.2
60V 3.4 17600 17910 0.2
110V - 125V 3.4 - 3.9 31790 - 31890 32450 - 32900 0.5
220V - 240V 3.3 - 3.6 65670 - 66070 65940 - 68570 0.85
Note 1 ±10% for 6V, 9V and 12V
6mm Electromechanical Contact Ratings
Allowable Contact Power Resistive Load 1500VA, 180W DC
Rated Load Resistive Load 250V AC 6A, 30V DC 6A
Allowable Switching Current 6A
Allowable Switching Voltage 400V AC, 125V DC
Allowable Switching Power 1500VA, 180W DC
Minimum Applicable Load 6V DC/10mA
6mm Solid State Input Ratings
Type Control Voltage
Range
Output / Input
Voltage Pickup Voltage Dropout Voltage Input Current Maximum
Operation Time
Maximum Release
Time
4.5-12V DC 24V DC / 6V DC 4.5V DC 1.5V DC 10mA±10%(±6VDC) 12s 200μs
19.6-30V DC 24V DC / 24V DC 19.6V DC 5V DC 9mA±10%(±24VDC) 350μs 200μs
96-132V AC 24V DC / 120V AC 96V AC 12V AC 10mA±10%(±120VAC) 11ms 14ms
192-264V AC 24V DC / 240V AC 192V AC 24V AC 10mA±10%(±240VAC) 11ms 14ms
4.5-12V DC 48V DC / 6V DC 4.5V DC 1.5V DC 6mA±10%(±6VDC) 40μs 300μs
19.6-30V DC 48V DC / 24V DC 19.6V DC 5V DC 7mA±10%(±24VDC) 40μs 300μs
96-132V AC 48V DC / 120V AC 96V AC 12V AC 10mA±10%(±120VAC) 8ms 14ms
192-264V AC 48V DC / 240V AC 192V AC 24V AC 10mA±10%(±240VAC) 8ms 14ms
Zero
Crossing
4.5-12V DC 240V AC / 6V DC 4.5V DC 2V DC 15mA±10%(±6VDC) 10ms 10ms
19.6-30V DC 240V AC / 24V DC 19.6V DC 5V DC 7mA±10%(±24VDC) 10ms 10ms
96-132V AC 240V AC / 120V AC 96V AC 12V AC 10mA±10%(±120VAC) 16ms 20ms
192-264V AC 240V AC / 240V AC 192V AC 24V AC 10mA±10%(±240VAC) 16ms 20ms
Random
Crossing
4.5-12V DC 240V AC / 6V DC 4.5V DC 2V DC 15mA±10%(±6VDC) 300μs 10ms
19.6-30V DC 240V AC / 24V DC 19.6V DC 5V DC 7mA±10%(±24VDC) 300μs 10ms
96-132V AC 240V AC / 120V AC 96V AC 12V AC 10mA±10%(±120VAC) 8ms 20ms
192-264V AC 240V AC / 240V AC 192V AC 24V AC 10mA±10%(±240VAC) 8ms 20ms
Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
845
800-262-IDEC (4332) USA & Canada
RV8H and RV8S
Relays & Sockets
1705151135
6mm Solid State Output Ratings
Typical Input Voltage 24V DC 48V DC 240V AC
Output Device MOSFET Photo-transistor Triac
Operating Voltage Range 0-24V DC 0-48V DC 24-280V AC (47-63Hz)
Maximum Load Current 3.5A 100mA 2A
Minimum Load Current 1mA 1mA 70mA
Maximum Blocking Voltage 30V DC 60V DC 600V AC
Maximum Surge Current 9A (10ms) 300mA (10ms) 120A pk (16.6ms)
Maximum l2t for Fusing 60A² sec
Typical On-State Leakage Current 0.4V 1V 1.1V (peak)
Maximum Off-State Leakage Current 0.001mA 0.001mA 4mA
Switching Conguration Normally Open Normally Open Normally Open
14mm Electromechanical Coil Ratings
Rated Volt-
age
Rated Current
±15% (mA)1
(at 23°C)
Circuit AC Resistance
±15% (Ω)1
(at 23°C)
Operating Characteristics
(Against Rated Voltage) Opera-
tion and
release
time
Power Consumption (W)
DC AC
50Hz
AC
60Hz DC AC
50Hz
AC
60Hz
Pickup
Voltage
(at 23°C)
Dropout
Voltage
(at 23°C)
Maximum
Allowable
Voltage
(at 23°C)
Maximum
Allowable
Voltage2
DC AC
(50Hz)
AC
(60Hz)
DC
6V 75.0 80
80% max 7% min
120%
110%2 15ms max
0.45 --
9V 44.0 205 0.40 --
12V 32.0 375 0.38 --
18V 24.0 750 0.43 --
24V 20.0 1200 0.48 --
AC/
DC
12V 32.0 29.0 29.0 375 414 414
110%
0.38 0.35 0.35
18V 24.0 24.0 24.0 750 750 750 0.43 0.43 0.43
24V 20.0 21.0 21.0 1200 1143 1143 0.48 0.50 0.50
48V 7.6 9.0 9.0 6316 5333 5333 0.36 0.43 0.43
60V 7.6 9.0 9.0 7895 6667 6667 0.46 0.54 0.54
110V -
125V 4.4~5.1 5.3-5.8 5.3-5.8 24510 21552 21552 0.64 0.73 0.73
220V -
240V 4~4.6 4.5-5.2 4.8-5.5 52174 46154 43636 1.10 1.25 1.32
Note 1: Input voltages lower than 24V: ±10%
Note 2: At rated operating temperature
Switches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
RV8H and RV8S Relays & Sockets
846 www.IDEC.com 1705151135
14mm Contact Ratings
Screw Terminal Spring Clamp Terminal
Allowable contact power Resistive load 1 Pole 4,000VA 1 Pole 3,000VA
2 Pole 2,000VA 2 Pole 1,500VA
Inductive load B300 (pilot duty) B300 (pilot duty)
Rated Load Resitive load
1 Pole 250V AC, 16A (8A per terminal) at 5C, 12A (6A per terminal)
at 7C 1 Pole 250V AC, 12A (6A per terminal) at 70°C
2 Pole 250V AC, 8A at 55°C, 6A at 7C 2 Pole 250V AC, 6A at 70°C
Inductive load B300 (pilot duty) B300 (pilot duty)
Allowable
Switching Current
1 Pole 16A (8A per terminal) at 5C, 12A (6A per terminal) at 70°C 1 Pole 12A (6A per terminal) at 70°C
2 Pole 8A at 55°C, 6A at 70°C 2 Pole 6A at 70°C
Allowable
Switching Power
1 Pole 4,000VA 1 Pole 3,000VA
2 Pole 2,000VA 2 Pole 1,500VA
Minimum Applicable Load (reference value) 1 Pole 6VDC 100mA 1 Pole 6VDC 100mA
2 Pole 5VDC 10mA 2 Pole 5VDC 10mA
Accessories
Jumper, Spacer, and Screwdriver
6mm Color Part Number
Jumper for 6mm Relay
(20 combs) 1, 2, 6
Black SV9Z-J20B
Gray SV9Z-J20W
Blue SV9Z-J20S
14mm
Jumper for 14mm Relay
(32 combs, with 2 combs per relay,
or 16 discrete relays.) 3, 4, 6
Black SV9Z-J232B
Gray SV9Z-J232W
Blue SV9Z-J232S
Spacer (circuit separator) 5, 6
SV9Z-SA2W
Screwdriver
BC1S-SD0
1. Jumper combs come with 20 points for 6mm relays. If shorter lengths are needed,
simply cut off the excess points.
2. Ensure that the total current to the jumper does not exceed the overall rated current
(Rated current: 6A).
3. Jumper combs come with 16 pairs of combs for 14mm relays. If shorter lengths are
needed, simply cut off the excess points.
4. Ensure that the total current to the jumper does not exceed the overall rated current
(Rated current: 6A for spring-clamp terminals and 8A for screw type terminations).
5. Width of spacer: 2mm
6. When using a cut jumper, please use a spacer on the cut side. For additional information
see instruction sheet.
Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
847
800-262-IDEC (4332) USA & Canada
RV8H and RV8S
Relays & Sockets
1705151135
Marking Plate Part Numbers
6mm 14mm Part Number Engraving
Horizontal Orientation
Vertical Orientation
SV9Z-PW10 blank
SV9Z-PW10-1-10 1-10
SV9Z-PW10-11-20 11-20
SV9Z-PW10-21-30 21-30
SV9Z-PW10-31-40 31-40
SV9Z-PW10-41-50 41-50
SV9Z-PW10-51-60 51-60
SV9Z-PW10-61-70 61-70
SV9Z-PW10-71-80 71-80
SV9Z-PW10-81-90 81-90
SV9Z-PW10-91-100 91-100
SV9Z-PW10-A-J A-J
SV9Z-PW10-K-T K-T
SV9Z-PW10-U-Z U-Z
SV9Z-PW10-GROUND
SV9Z-PW10-AC
1. In place of insert orientation code: V=Vertical, H=Horizontal
2. Each unit has 10 pieces (marking plates).
Marking Plate Placement
Marking Plate
Insert
Locking Lever
Switches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
RV8H and RV8S Relays & Sockets
848 www.IDEC.com 1705151135
Dimensions (mm)
6mm Electromechanical and Solid State Relay
6mm Screw Terminal
88.0
35.0
74.2
69.6
6.1
6mm Spring Clamp Terminal
35.0
93.4
74.2
69.6
6.1
14mm Electromechanical Relay
14mm Screw Terminal 14mm Spring Clamp Terminal
74.2
88.0
35.0
69.6
14.0
35.0
93.4
69.6
74.2
14.0
Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
849
800-262-IDEC (4332) USA & Canada
RV8H and RV8S
Relays & Sockets
1705151135
Internal Connections
6mm Electromechanical Relay
PROTECTION
AND
INDICATION
CIRCUIT
11(13+)
14
12
A2
A1
AC/DC
PROTECTION
AND
INDICATION
CIRCUIT
11(13+)
14
12
A2-
A1+
DC
6mm Solid State Relay
PROTECTION
AND
INDICATION
CIRCUIT
13(13+)
14
A2
A1
OUTPUT : DC24V
INPUT : AC120V,AC240V
PROTECTION
AND
INDICATION
CIRCUIT
13(13+)
14
OUTPUT : DC24V
INPUT : DC6V,DC24V
A2-
A1+
PROTECTION
AND
INDICATION
CIRCUIT
13(13+)
14
A2
A1
OUTPUT : DC48V
INPUT : AC120V,AC240V
PROTECTION
AND
INDICATION
CIRCUIT
13(13+)
14
OUTPUT : DC48V
INPUT : DC6V,DC24V
A2-
A1+
PROTECTION
AND
INDICATION
CIRCUIT
13(13+)
14
A2
A1
OUTPUT : AC240V
INPUT : AC120V,AC240V
PROTECTION
AND
INDICATION
CIRCUIT
13(13+)
14
OUTPUT : AC240V
INPUT : DC6V,DC24V
A2-
A1+
14mm Electromechanical Relay 1 Pole
PROTECTION
AND
INDICATION
CIRCUIT
11/21
14/24
12/22
A2
A1
AC/DC
PROTECTION
AND
INDICATION
CIRCUIT
11/21
14/24
12/22
A2-
A1+
DC
14mm Electromechanical Relay 2 Pole
PROTECTION
AND
INDICATION
CIRCUIT
11
14
12
A2
A1
21
24
22
AC/DC
A2-
A1+
DC
PROTECTION
AND
INDICATION
CIRCUIT
11
14
12
21
24
22
Switches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
RV8H and RV8S Relays & Sockets
850 www.IDEC.com 1705151135
Accessories Dimensions
SV9Z-PW10* Marking Plate
86.5
6.0
10.5
16.5
Cut
1.0
3.0
*Available blank or pre-marked.
SV9Z-J20* Jumper for 6mm Relay
120.0
6.1
115.9
6.0
12.3
2.8
*Available in Black, Gray and Blue
SV9Z-SA2W Spacer for 6 and 14mm Relay
66.8
71.4
35.0
96.7 2.0
SV9Z-J232* Jumper for 14mm Relay
222.2
217.6
12.2
15-P 14.0
6.0
12.3
2.8
*Available in black, gray and blue.
Characteristics
6mm Electromechanical Relay
Maximum Switching Power AC Maximum Switching Power DC
Contact Current (A)
Contact Voltage (V)
AC Resistive load
AC Inductive load (p. f=0.35)
Contact Current (A)
Contact Voltage (V)
DC Resistive load
DC Inductive load
(L/R = 56ms)
Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
851
800-262-IDEC (4332) USA & Canada
RV8H and RV8S
Relays & Sockets
1705151135
6mm Solid State Continuous Load Current vs. Ambient Temperature Curves
24V DC 48V DC
*
0 10 20 30 40 50 60
2.3
240V AC Zero Cross
Load Current (Amperes)
Ambient Temperature (°C)
Air gap
6.2 mm
0.0
0.3
0.7
1.0
1.3
1.7
2.0
No air gap
0 10 20 30 40 50 60
0.0
0.6
1.2
1.8
2.4
3.0
3.5
4.0
24V DC
Load Current (Amperes)
Ambient Temperature (°C)
No air gap
Air gap
6.2 mm
0 10 20 30 40 50 60
0.00
48V DC
Load Current (Amperes)
Ambient Temperature (°C)
No minimum
air gap required
0.02
0.04
0.06
0.08
0.10
0.12
240V AC Random Cross
Load Current (Amperes)
Ambient Temperature (°C)
0 10 20 30 40 50 60
0.0
0.3
0.7
1.0
1.3
1.7
2.0
2.3
60
*
0 10 20 30 40 50 60
2.3
240V AC Zero Cross
Load Current (Amperes)
Ambient Temperature (°C)
Air gap
6.2 mm
0.0
0.3
0.7
1.0
1.3
1.7
2.0
No air gap
0 10 20 30 40 50 60
0.0
0.6
1.2
1.8
2.4
3.0
3.5
4.0
24V DC
Load Current (Amperes)
Ambient Temperature (°C)
No air gap
Air gap
6.2 mm
0 10 20 30 40 50 60
0.00
48V DC
Load Current (Amperes)
Ambient Temperature (°C)
No minimum
air gap required
0.02
0.04
0.06
0.08
0.10
0.12
240V AC Random Cross
Load Current (Amperes)
Ambient Temperature (°C)
0 10 20 30 40 50 60
0.0
0.3
0.7
1.0
1.3
1.7
2.0
2.3
60
240V AC Zero Cross 240V AC Random Cross
*
0 10 20 30 40 50 60
2.3
240V AC Zero Cross
Load Current (Amperes)
Ambient Temperature (°C)
Air gap
6.2 mm
0.0
0.3
0.7
1.0
1.3
1.7
2.0
No air gap
0 10 20 30 40 50 60
0.0
0.6
1.2
1.8
2.4
3.0
3.5
4.0
24V DC
Load Current (Amperes)
Ambient Temperature (°C)
No air gap
Air gap
6.2 mm
0 10 20 30 40 50 60
0.00
48V DC
Load Current (Amperes)
Ambient Temperature (°C)
No minimum
air gap required
0.02
0.04
0.06
0.08
0.10
0.12
240V AC Random Cross
Load Current (Amperes)
Ambient Temperature (°C)
0 10 20 30 40 50 60
0.0
0.3
0.7
1.0
1.3
1.7
2.0
2.3
60
*
0 10 20 30 40 50 60
2.3
240V AC Zero Cross
Load Current (Amperes)
Ambient Temperature (°C)
Air gap
6.2 mm
0.0
0.3
0.7
1.0
1.3
1.7
2.0
No air gap
0 10 20 30 40 50 60
0.0
0.6
1.2
1.8
2.4
3.0
3.5
4.0
24V DC
Load Current (Amperes)
Ambient Temperature (°C)
No air gap
Air gap
6.2 mm
0 10 20 30 40 50 60
0.00
48V DC
Load Current (Amperes)
Ambient Temperature (°C)
No minimum
air gap required
0.02
0.04
0.06
0.08
0.10
0.12
240V AC Random Cross
Load Current (Amperes)
Ambient Temperature (°C)
0 10 20 30 40 50 60
0.0
0.3
0.7
1.0
1.3
1.7
2.0
2.3
60
Legend
No spacing required between units. Spacing of 6.2mm minimum required between units Not Recommended
Switches & Pilot LightsSignaling LightsRelays & SocketsTimersContactorsTerminal BlocksCircuit Breakers
RV8H and RV8S Relays & Sockets
852 www.IDEC.com 1705151135
14mm Electromechanical Relays
14 mm Electrical Life Curve AC Load
2 Pole
1 Pole
Contact Current (A)
1000
100
10
10123 4 5 8 10 16
14mm Contact Ratings
AC
1 Pole
2 Pole
Contact Current (A)
Contact Voltage (V)
10 20 30 40 50 100 200 300 400 500
16
10
8
1
0.1
DC
1 Pole
2 Pole
Contact Current (A)
Contact Voltage (V)
10 20 30 40 50 100 200 300 400 500
16
10
8
1
0.1