MCC omponents 20736 Marilla Street Chatsworth !"# $ % !"# Features * * * * MUR105GP THRU MUR160GP 1.0 Amp Glass Passivated Super Fast Recovery Rectifier 50 to 600 Volts High Surge Capability Low Forward Voltage Drop High Current Capability Super Fast Switching Speed For High Efficiency Maximum Ratings * * Operating Temperature: -65C to +150C Storage Temperature: -65C to +150C MCC Part Number MUR105GP MUR110GP MUR115GP MUR120GP MUR140GP MUR160GP Maximum Recurrent Peak Reverse Voltage 50V 100V 150V 200V 400V 600V DO-41 Maximum RMS Voltage Maximum DC Blocking Voltage 35V 70V 105V 140V 280V 420V 50V 100V 150V 200V 400V 600V D Electrical Characteristics @ 25C Unless Otherwise Specified Average Forward IF(AV) 1.0A TA = 55C Current Peak Forward Surge IFSM 25A 8.3ms, half sine Current Maximum Instantaneous Forward Voltage VF IFM = 1.0A; MUR105GP-115GP .97V 1.35V TA = 25C MUR120GP-160GP Maximum DC 5.0A TA = 25C Reverse Current At IR Rated DC Blocking TA = 150C 50A Voltage Maximum Reverse Recovery Time Trr MUR105GP-140GP 45ns IF=0.5A, IR=1.0A, Irr=0.25A 60ns MUR160GP Typical Junction Capacitance CJ MUR105GP-115GP 15pF Measured at 10pF 1.0MHz, VR=4.0V MUR120GP-160GP *Pulse Test: Pulse Width 300sec, Duty Cycle 1% A Cathode Mark B D C DIMENSIONS INCHES DIM A B C D MIN .166 .080 .028 1.000 MAX .205 .107 .034 --- MM MIN 4.10 2.00 .70 25.40 MAX 5.20 2.70 .90 --- NOTE www.mccsemi.com Revision: 3 2003/04/30 MCC MUR105GP thru MUR160GP Figure 1 Typical Forward Characteristics 20 Figure 2 Forward Derating Curve 10 1.5 6 4 MUR105GP-115GP 1.25 2 25C Amps 1.0 1 .6 .75 Amps .4 .5 .2 MUR120GP-160GP .25 .1 .06 0 .04 Single Phase, Half Wave 60Hz Resistive or Inductive Load 0 50 75 100 125 150 175 C .02 .01 .7 .5 .9 1.1 1.3 Average Forward Rectified Current - Amperes versus Ambient Temperature - C 1.5 Volts Instantaneous Forward Current - Amperes versus Instantaneous Forward Voltage - Volts Figure 3 Junction Capacitance 100 MUR105GP-115GP 60 40 MUR120GP-160GP 20 pF TJ=25C 10 6 4 2 1 .1 .2 .4 1 Volts 2 4 10 20 40 100 200 400 1000 Junction Capacitance - pF versus Reverse Voltage - Volts www.mccsemi.com Revision: 3 2003/04/30 MCC MUR105GP thru MUR160GP Figure 4 Typical Reverse Characteristics Figure 5 Peak Forward Surge Current 100 30 60 40 TA=150C 20 20 10 6 Amps 4 10 2 TA=100C 0 Amps 1 1 4 2 .6 6 8 10 20 40 60 80 100 Cycles .4 Peak Forward Surge Current - Amperes versus Number Of Cycles At 60Hz - Cycles .2 TA=25C .1 .06 .04 .02 .01 2 60 4 80 100 120 140 Volts Instantaneous Reverse Leakage Current - MicroAmperes versus Percent Of Rated Peak Reverse Voltage - Volts Figure 6 Reverse Recovery Time Characteristic And Test Circuit Diagram 50 10 trr +0.5A 0 Pulse Generator Note 2 25Vdc 1 Notes: 1. Rise Time = 7ns max. Input impedance = 1 megohm, 22pF 2. Rise Time = 10ns max. Source impedance = 50 ohms 3. Resistors are non-inductive Oscilloscope Note 1 -0.25 -1.0 1cm Set Time Base for 20/100ns/cm www.mccsemi.com Revision: 3 2003/04/30