MUR105GP
THRU
MUR160GP
1.0 Amp Glass
Passivated Super Fast
Recovery Rectifier
50 to 600 Volts
Features
High Surge Capability
Low Forward Voltage Drop
High Current Capability
Super Fast Switching Speed For High Efficiency
Maximum Ratings
Operating Temperature: -65°C to +150°C
Storage Temperature: -65°C to +150°C
MCC
Part Number
Maximum
Recurrent
Peak Reverse
Voltage
Maximum
RMS Voltage
Maximum DC
Blocking
Voltage
MUR105GP
50V 35V 50V
MUR110GP
100V 70V 100V
MUR115GP
150V 105V 150V
MUR120GP
200V 140V 200V
MUR140GP
400V 280V 400V
MUR160GP
600V 420V 600V
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current IF(AV) 1.0A TA = 55°C
Peak Forward Surge
Current IFSM 25A 8.3ms, half sine
Maximum
Instantaneous
Forward Voltage
MUR105GP-115GP
MUR120GP-160GP
VF .97V
1.35V IFM = 1.0A;
TA = 25°C
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
IR 5.0µA
50µA TA = 25°C
TA = 150°C
Maximum Reverse
Recovery Time
MUR105GP-140GP
MUR160GP
Trr 45ns
60ns IF=0.5A, IR=1.0A,
Irr=0.25A
Typical Junction
Capacitance
MUR105GP-115GP
MUR120GP-160GP
CJ 15pF
10pF Measured at
1.0MHz, VR=4.0V
*Pulse Test: Pulse Width 300µsec, Duty Cycle 1%
DIMENSIONS
INCHES MM
DIM MIN MAX MIN MAX NOTE
A .166 .205 4.10 5.20
B .080 .107 2.00 2.70
C .028 .034 .70 .90
D 1.000 --- 25.40 ---
A
B
C
D
Cathode
Mark
DO-41
omponents
20736 Marilla Street Chatsworth

 !"#
$% !"#
MCC
www.mccsemi.com
Revision: 3 2003/04/30
Average Forward Rectified Current - Amperes versus
Ambient Temperature - °C
Figure 2
Forward Derating Curve
0
175
50
75
100
125
0
.25
.5
.75
Amps
°C
150
1.0
1.25
1.5
Junction Capacitance - pF versus
Reverse Voltage - Volts
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
4
6
20
10
Amps
.5
.7
.9
1.1
1.3
1.5
.01
.02
.04
.06
.1
.2
.4
.6
1
2
25°C
Volts
Figure 3
Junction Capacitance
.1
.2
1
.4
2
10
20
40
4
100
200
1
2
6
10
20
100
pF
Volts
60
40
4
400
1000
TJ=25°C
MUR105GP-115GP
MUR120GP-160GP
MUR105GP-115GP
MUR120GP-160GP
MUR105GP thru MUR160GP
Single Phase, Half Wave
60Hz Resistive or Inductive Load
www.mccsemi.com
MCC
Revision: 3 2003/04/30
trr
+0.5A
0
-0.25
-
1
.0
1cm
Set Time Base for 20/100ns/cm
25Vdc
1
50
10
Oscilloscope
Note 1
Pulse
Generator
Note 2
Notes:
1. Rise Time = 7ns max.
Input impedance = 1 megohm, 22pF
2. Rise Time = 10ns max.
Source impedance = 50 ohms
3. Resistors are non-inductive
Figure 6
Reverse Recovery Time Characteristic And Test Circuit Diagram
1
100
4
0
10
8
Figure 5
Peak Forward Surge Current
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
6
10
20
60
80
4
0
20
30
Figure 4
Typical Reverse Characteristics
Instantaneous Reverse Leakage Current - MicroAmperes versus
Percent Of Rated Peak Reverse Voltage - Volts
Volts
4
6
20
10
µAmps
2120
460
80
100
.01
.02
.
04
.06
.1
.2
.4
.6
1
2
TA=25°C
40
6
0
1
00
1
40
TA=100°C
TA=150°C
MUR105GP thru MUR160GP
www.mccsemi.com
MCC
Revision: 3 2003/04/30