120W Single Output Industrial DIN RAIL NDR-120 series Bauar t gepruft Sicherheit egel ma ge od o s be wac g www.tuv.com ID 2000000000 TPTC004 Features Universal AC input / Full range Protections: Short circuit / Overload / Over voltage / Over temperature Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 UL 508 (industrial control equipment) approved EN61000-6-2(EN50082-2) industrial immunity level 100% full load burn-in test 3 years warranty EN62368-1 IEC62368-1 Applications Industrial control system Semiconductor fabrication equipment Factory automation Electro-mechanical apparatus Description NDR-120 is one economical slim 120W DIN rail power supply series, adapt to be installed on TS-35/7.5 or TS-35/15 mounting rails. The body is designed 40mm in width, which allows space saving inside the c a b i n e t s . T h e e n t i r e s e r i e s a d o p t s th e f u l l r a n g e AC i n p u t f r o m 9 0 V A C t o 2 6 4 V A C a n d c o n f o r m s t o EN61000-3-2, the norm the European Union regulates for harmonic current. NDR-120 is designed with metal housing that enhances the unit's power dissipation. With working efficiency up to 89%, the entire series can operate at the ambient temperature between -20 and 70 under air convection. It is equipped with constant current mode for over-load protection, fitting various inductive or capacitive applications. The complete protection functions and relevant certificates for industrial control apparatus (UL508, TUV EN62368-1, and etc.) make NDR-120 a very competitive power supply solution for industrial applications. Model Encoding NDR - 120 - 12 Output voltage Output wattage Series name File Name:NDR-120-SPEC 2020-01-04 NDR-120 120W Single Output Industrial DIN RAIL series SPECIFICATION MODEL OUTPUT NDR-120-12 NDR-120-24 NDR-120-48 DC VOLTAGE 12V 24V 48V RATED CURRENT 10A 5A 2.5A CURRENT RANGE 0 ~ 10A 0 ~ 5A 0 ~ 2.5A RATED POWER 120W 120W 120W RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 150mVp-p VOLTAGE ADJ. RANGE 12 ~ 14V VOLTAGE TOLERANCE Note.3 2.0% 24 ~ 28V 1.0% 48 ~ 55V 1.0% LINE REGULATION 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% SETUP, RISE TIME 1200ms, 60ms/230VAC HOLD UP TIME (Typ.) 16ms/230VAC VOLTAGE RANGE INPUT Note.6 90 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 85.5% 2.25A/115VAC 20A/115VAC LEAKAGE CURRENT <1mA / 240VAC 105 ~ 130% rated output power (Note 4) OVER TEMPERATURE Shut down o/p voltage, re-power on to recover WORKING TEMP. -20 ~ +70 (Refer to "Derating Curve") 56 ~ 65V 20 ~ 95% RH non-condensing -40 ~ +85, 10 ~ 95% RH 0.03%/ (0 ~ 50) Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 UL508, TUV EN62368-1, EAC TP TC 004 approved;(meet EN60204-1) I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE EMC EMISSION I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3, EAC TP TC 020 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A, EAC TP TC 020 456.3K hrs min. MIL-HDBK-217F (25) 40*125.2*113.5mm (W*H*D) 0.6Kg; 20pcs/13Kg/1.16CUFT DIMENSION PACKING NOTE 89% Protection type : Constant current limiting, recovers automatically after fault condition is removed OVER VOLTAGE MTBF OTHERS 88% 1.3A/230VAC 35A/230VAC 14 ~ 17V 29 ~ 33V Protection type : Shut down o/p voltage, re-power on to recover WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)] AC CURRENT (Typ.) INRUSH CURRENT (Typ.) OVERLOAD PROTECTION 2500ms, 60ms/115VAC at full load 10ms/115VAC at full load 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended. 6. Derating may be needed under low input voltage. Please check the derating curve for more details. 7. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft). File Name:NDR-120-SPEC 2020-01-04 NDR-120 120W Single Output Industrial DIN RAIL series Block Diagram fosc : 70KHz EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING +V -V O.C.P. O.L.P. FG DETECTION CIRCUIT PWM CONTROL O.T.P. O.V.P. Derating Curve Static Characteristics 230VAC 100 12V,24V,48V 100 90 80 80 115VAC 50 LOAD (%) LOAD (%) 70 12V (115VAC only) 60 40 20 -20 -10 0 10 20 30 40 45 50 AMBIENT TEMPERATURE () 60 70 (VERTICAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE (V) 60Hz File Name:NDR-120-SPEC 2020-01-04 NDR-120 120W Single Output Industrial DIN RAIL series Mechanical Specification Case No.992D Unit:mm Top View 113.5 40 12 3 4 35 TB2 + 125.2 +V ADJ. DC OK TB1 1 2 3 Side View Front View Side View Terminal Pin No. Assignment (TB1) Pin No. 1 2 3 Assignment FG AC/N or DC AC/L or DC + Terminal Pin No. Assignment (TB2) Pin No. 1,2 3,4 Assignment DC OUTPUT -V DC OUTPUT+V Bottom View Installation Instruction 35 This series fits DIN rail TS35/7.5 or TS35/15. For installation details, please refer to the Instruction manual. ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15 (For reference only. Not included with unit.) Back View Installation Manual Please refer to : http://www.meanwell.com/manual.html File Name:NDR-120-SPEC 2020-01-04