150W 2” x 4” Open Frame Switching Power Supplies ASL150 series
ASTRODYNE USA: 1-800-823-8082
WWW.ASTRODYNETDI.COM ASTRODYNE PACIFIC: 886-2-26983458
INPUT SPECIFICATIONS
Input Voltage Range (AC / DC) 90-264 / 170-370
Input Current <2.5A @ 100VAC
Inrush Current 72A @ 115V; 144A @ 230V, typ.
Input Frequency 47-63Hz
Power Factor (90VAC) 0.98%
Harmonic Input Current Meets EN61000-3-2
Input Fuse 3A Internal Line & Neutral
Under Voltage Lockout 80VAC Auto Recover
Leakage Current (120V I/P) <275uA
OUTPUT SPECIFICATIONS
Setpoint Accuracy +/-1% Main Output V1
Overshoot during Power-on Out of regulation 50mS, max.
Voltage Adjust 5% Main Output V1
Load Regulation +/-1% V1; +/-20% V2
Line Regulation +/-0.1% 90-264VAC
Cross Regulation +/-1% V1; +/-15% V2
Transient Response
(50% Load Change) 10% Recover within 1mS
Start Up (HL; FL) 500mS
Rise / Hold Up Time 20mS / 16mS
Temperature Coefcient +/-0.25mV/°C
Ripple/Noise: 20Mhz BW, resistive load, with 22uF (tantalum) and
0.47uF (ceramic) parallel capacitors at POL
1% of Output (500mV, 12V aux.)
Over-voltage Protection 130% max.
Over Current Protection 130% max. Auto Recover*
Short Circuit and Over Temp Protection
Auto Recovery *
GENERAL SPECIFICATIONS
I/P-O/P Isolation 3000VAC for 1 Minute
I/P-Ground Isolation 1500VAC for 1 Minute
O/P-O/P Isolation 100VDC for 1 Minute
O/P-Ground Isolation 500VAC for 1 Minute
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature -20 to +50°C FL Derate Linearly to
50% Load at 70°C *
Cooling 200LFM >100W O/P Power
Relative Humidity 8-90% Non Cond (95% Non-Oper.)
Storage Temperature -40 to +80°C *
Operating Altitude 5000 ft Above Sea Level
Derate to 40°C ambient @ 10,000 ft
MTBF Convection Cooled: 150,000Hrs
Air Flow (200 CFM): 300,000 Hrs
EMC / CE Mark Requirements EN55024
Voltage Fluctuation EN61000-3-3
ESD 15KV Air, 8KV Contact
Radiated Field 3V/m, 80-1000MHz 80% Modulation
at distance of 3M
EFT ±2kV on AC power port for 1 minute;
±1kV on signal/ctrl lines
Surge ±1kV line to line/±2kV line to earth
on AC power port; ±0.5kV for outdoor
cables
Conducted RF 3V; 0.15-80MHz 80% Modulation
Voltage Variations >95% dip, 0.5 period; 30% dip, 25
periods; >95% reduction, 250 periods
Safety (c)UL: UL 60950-1, 2nd Edition, 03-27-2007
covering European Market
CB: IEC 60950-1
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
All specications are typical at nominal input, full load, and 25DegC unless
otherwise noted