Series AM15EW-Z 15 Watt | DC-DC Converter FEATURES: * * * * RoHS compliant Efficiency up to 86% Wide 4:1 input range Continuous Short Circuit Protection * * Low ripple and noise Remote on/off control Input/Output Isolation 1500VDC Operating temperature -40oC to + 85oC Models Single output Model AM15EW-2403SZ AM15EW-2405SZ AM15EW-2412SZ AM15EW-2415SZ AM15EW-4803SZ AM15EW-4805SZ AM15EW-4812SZ AM15EW-4815SZ Input Voltage (V) Output Voltage (V) 9-36 9-36 9-36 9-36 18-72 18-72 18-72 18-72 3.3 5 12 15 3.3 5 12 15 Input Voltage (V) Output Voltage (V) Output Current max (A) Capacitive load (F) Efficiency (%) 3300 3300 680 470 3300 3300 680 470 80 83 85 86 80 83 85 86 Capacitive load (F) Efficiency (%) 2200 470 330 2200 470 330 83 85 86 83 85 86 3 3 1.25 1 3 3 1.25 1 Models Dual output Model AM15EW-2405DZ AM15EW-2412DZ AM15EW-2415DZ AM15EW-4805DZ AM15EW-4812DZ AM15EW-4815DZ 9-36 9-36 9-36 18-72 18-72 18-72 Output Current max (A) 5 12 15 5 12 15 1.5 0.625 0.5 1.5 0.625 0.5 Input Specifications Parameters Voltage range Nominal Typical 24 48 9-36 18-72 (Pi) Network 2.5~5.5 or open circuit -0.7~ 0.8 or short circuit b/n pin 2 & 1 Filter Remote ON/OFF Control ON OFF Turn on Transient process time Start up time Absolute Maximum Rating Maximum VDC VDC 350 20 -0.7-40 -0.7-80 100 24 Vin 48 Vin Peak Input Voltage time Units ms ms VDC ms Isolation Specifications Parameters Tested I/O voltage Case/ Input & Output Resistance Capacitance Conditions 3 sec Typical Maximum Units VDC VDC MOhm pF Maximum Units 1500 1000 > 1000 1200 Output Specifications Parameters Voltage accuracy Voltage balance (Dual Output) www.aimtec.com F 051e R6.A Conditions Typical Balance Load 1 1 Tel: +1 514 620 2722 1 of 3 % % Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM15EW-Z 15 Watt | DC-DC Converter Output Specifications (continued) Parameters Short Circuit protection Short Circuit restart Current limiting Line voltage regulation Load voltage regulation Load voltage regulation Temperature coefficient Ripple & Noise Rising time Conditions Typical Maximum Units 140 % of Iout max % % % %/oC mV p-p ms Continuous Auto Recovery HL-LL 10-100% load below 10% load 0.5 0.5 1.0 0.02 75 10 At 20Mhz bandwidth General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum Case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Conditions 100% load Typical 300 Derating above 60C Maximum Units KHz o -40 to +85 -40 to +125 C C o C o 100 Free air convection % 95 Nickel coated copper g 30 2.00 x 1.00 x 0.40 inches 50.80 x 25.40 x 10.16 mm Tolerance 0.5mm >1 121 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) NOTE: All specifications in this datasheet are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Standards Safety Agency Approvals meets IEC 60950-1:2001 EN55022 Class A, EN55024 IEC61000-4-2, Perf. Criteria B IEC61000-4-3, Perf. Criteria A IEC61000-4-4, Perf. Criteria B IEC61000-4-6, Perf. Criteria A IEC61000-4-8, Perf. Criteria A Pin Out Specifications Pin Single Dual 1 2 3 4 5 6 On/Off Control -V Input +V Input -V Output No Pin +V Output On/Off Control -V Input +V Input -V Output Common +V Output www.aimtec.com F 051e R6.A Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM15EW-Z 15 Watt | DC-DC Converter Dimensions 1 15.24 (0.60) 4 20.32 (0.80) 15.24 (0.60) 10.16 (0.40) 5 Notes: All dimensions are typical in millimeters (inches). Tolerance 0.25 (0.01) 5.08 (0.20) Min 10.16 (0.40) Bottom View 2.54 (0.10) 2 10.16 (0.40) 3 7.62 5.08 (0.30) (0.20) 25.40 (1.00) 10.16 (0.40) 6 Built-in Stand-offs to ease PCB cleaning DIA 1.00 (0.04) 2.54 (0.10) 50.80 (2.00) Derating Test Circuit A Free Air 60 C B 100 LFM 75 C Conducted Emissions: B A Output Power (%) 100 80 60 Safe Operating Area 40 20 0 - 40 - 20 0 20 40 60 80 85 100 Ambient Temperature C NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 5. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. www.aimtec.com F 051e R6.A Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only