58
G6EG6E
Specifications
■Coil Ratings
Single-side Stable, Bifurcated Crossbar Contact Type
Single-winding Latching, Bifurcated Crossbar Contact Type
Double-winding Latching, Bifurcated Crossbar Contact Type
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
■Contact Ratings
Note: P level: λ60 = 0.1 x 10–6/operation
This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value
may vary depending on the operating environment. Always double-check relay suitability under actual operating conditions.
Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 48 VDC
Rated current 66.7 mA 40 mA 33.3 mA 22.2 mA 16.7 mA 8.3 mA 8.3 mA
Coil resistance 45 Ω125 Ω180 Ω405 Ω720 Ω2,880 Ω5,760 Ω
Coil inductance
(H) (ref. value)
Armature OFF 0.08 0.18 0.31 0.62 1.20 4.70 5.35
Armature ON 0.06 0.17 0.24 0.50 0.99 3.90 5.12
Must operate voltage 70% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 190% of rated voltage at 23°C 170% of rated voltage at
23°C
Power consumption Approx. 200 mW Approx. 400 mW
Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC
Rated current 66.7 mA 40 mA 33.3 mA 22.2 mA 16.7 mA 8.3 mA
Coil resistance 45 Ω125 Ω180 Ω405 Ω720 Ω2,880 Ω
Coil inductance
(H) (ref. value)
Armature OFF 0.05 0.13 0.19 0.45 0.84 3.56
Armature ON 0.04 0.12 0.17 0.40 0.79 3.10
Must set voltage 70% max. of rated voltage
Must reset voltage 70% max. of rated voltage
Max. voltage 190% of rated voltage at 23°C
Power consumption Approx. 200 mW
Rated voltage 3 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC
Set coil Rated current 66.7 mA 40 mA 33.3 mA 22.2 mA 16.7 mA 8.3 mA
Coil resistance 45 Ω125 Ω180 Ω405 Ω720 Ω2,880 Ω
Coil inductance
(H) (ref. value)
Armature OFF 0.03 0.09 0.12 0.25 0.44 1.66
Armature ON 0.03 0.08 0.11 0.22 0.41 1.62
Reset coil Rated current 66.7 mA 40 mA 33.3 mA 22.2 mA 16.7 mA 8.3 mA
Coil resistance 45 Ω125 Ω180 Ω405 Ω720 Ω2,880 Ω
Coil inductance
(H) (ref. value)
Armature OFF 0.03 0.09 0.12 0.25 0.44 1.66
Armature ON 0.03 0.08 0.11 0.22 0.41 1.62
Must set voltage 70% max. of rated voltage
Must reset voltage 70% max. of rated voltage
Max. voltage 190% of rated voltage at 23°C
Power consumption Set coil: Approx. 200 mW
Reset coil: Approx. 200 mW
Load Resistive load (cosφ = 1) Inductive load (cosφ = 0.4; L/R = 7 ms)
Rated load 0.4 A at 125 VAC; 2 A at 30 VDC 0.2 A at 125 VAC; 1 A at 30 VDC
Contact material Ag (Au-Alloy)
Rated carry current 3 A
Max. switching voltage 250 VAC, 220 VDC
Max. switching current 3 A 3 A
Max. switching power 50 VA, 60 W 25 VA, 30 W
Failure rate (reference value) (See note.) 10 µA at 10 mVDC