XTRA FLEX(R) System -- Conduit, Tubing, Fittings for Non-Metallic Liquidtight Conduit Specification Sheet -- Bullet(R) Liquidtight Fittings or Liquidtight Flexible Non-Metallic Conduit and Tubing Application A series of nonmetallic connectors designed to provide a liquidtight seal when terminating liquidtight nonmetallic conduit (UL Type B) or liquidtight nonmetallic tubing to a box or enclosure with knockout opening or a threaded hub. Box or Enclosure Wall Plastic Bullet(R) Liquidtight Fittings Features * Connector assembles to conduit without disassembly and is designed to be installed with a positive installation criteria gland bottoms on body shoulder Conduit or Tubing Suggested Specification: Where liquidtight flexible non-metallic conduit (UL Type B) or liquidtight flexible non-metallic tubing is terminated to a box or enclosure, the non-metallic connectors used shall be able to be installed without disassembly and provide a positive installation criteria. In the installed condition, the connector must provide a seal meeting watertight requirements of NEMA Type 4 and Type 6 enclosures. The performance of connectors shall be unaffected by exposure to detergents, sanitizers, cutting fluids, wire pulling compounds and oil base industrial paints. The connector must also be capable of withstanding Marine environment and cold impact simulating a hammer blow. Installed connectors shall be of the elongated gland type as manufactured by Thomas & Betts LT38P series. * Rugged low profile non-metallic body and gland construction (1); the connector is equipped with a steel locknut to firmly secure connector to box or an enclosure and a sealing O-Ring * Captivated sealing O-Ring (2) with predetermined compression for a reliable seal at enclosure Standard Material/Finish * Body Gland -- Weather stabilized thermoplastic (black) * O-Ring -- Nitrile (blue) * Locknut -- Steel/electro zinc plated * Material Temperature Rating -- thermoplastic -40 C to 105 C * Material Flammability Rating: UL 94-V2 Listed/Certified by * Connector ferrule designed to accept variations in conduit inside diameter and is tolerant of field conduit cuts (3) * The profile of ferrule is designed to reduce friction between conduit I.D. and ferrule, (4) enabling conduit to seat properly for an effective seal UL (File# E23018); CSA (File# LR52391) Conforms to * CSA 22.2 #227.2 & CSA 22.2 #227.3 * ANSI/U.L.514B-1988 * Outer surface of the clamping fingers provided with friction reducing ridges (5) for ease of installation; the inner surface is designed with conduit biting teeth to enhance clamping and sealing action (6) * Performance of connectors tested to simulate adverse installation conditions * Performance of connector unaffected by exposure to detergents, cleaners and sanitizers commonly encountered in food processing plants and typical industrial environment; also unaffected by cutting fluids, wiring pulling compounds and marine environment. The connector meets industry standards for cold impact and simulated hammer blow. * Watertight requirements of NEMA Type 4 and NEMA Type 6 enclosures * Federal Standard H28 (NPT threads) * Suitable for hazardous locations -- Class I Div. 2; Class II Div. 1 & 2; Groups E,F, & G; Class III per N.E.C.; Article 501-4, 502-4 and 503-3 * NEMA 6P * Provides a double sealing action (7) * Elongated gland nut profile (8) designed to provide additional strain relief for 90 pull and an easy hand grip. A-122 www.tnb.com United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 Canada Tel: 450.347.5318 Fax: 450.347.1976 Technical Services Tel: 888.862.3289 XTRA FLEX(R) System -- Conduit, Tubing, Fittings for Non-Metallic Liquidtight Conduit The BULLET(R) non-metallic liquidtight fitting -- easy to use, built to take it! Plastic Bullet(R) Liquidtight Fittings for T&B LTC Non-Metallic Liquidtight Conduit Type B and T&B EFC Flexible Tubing This engineering breakthrough meets the demand for a tough, reusable, non-metallic liquidtight fitting for use with XTRA FLEX(R) Type B conduit or flexible tubing. The BULLET(R) non-metallic fitting provides a reliable liquidtight seal that combines high pullout resistance and ease of installation. * Outside surface has frictionreducing ridges Corrosion resistant. Built to take it. * Inner surface teeth bite into conduit or tubing to enhance clamping and sealing action Engineered to meet your needs. * Fitting ferrule designed to accept variations in conduit sizes and field conduit cuts * Smooth ferrule profile reduces friction to ensure a tight conduit-to-fitting seal * Friction-reducing ridges and teeth provide a true double seal and high pullout resistance The BULLET(R) non-metallic fitting meets your performance requirements when terminating Type B liquidtight non-metallic conduit or flexible non-metallic tubing to a box or enclosure with knockout opening or threaded hub. Fittings meet the watertight requirements for NEMA Type 4 and Type 6 enclosures and conform to UL514B and CSA No. 22.2 #227.2 specifications. Installations can be performed quickly and easily because BULLET(R) liquidtight fittings can be installed without disassembly. BULLET(R) nonmetallic fittings are resistant to numerous caustics and solvents. * Rugged low-profile nonmetallic body and gland construction provides space savings * Captivated sealing O-Ring features predetermined compression to provide a reliable seal at enclosure * Steel locknut firmly secures fitting to box or enclosure F* C B* B* A E THREAD D A E THREAD D FIGURE 2 (45 DEGREE) FIGURE 1 (STRAIGHT) F* C B* E THREAD A D The BULLET(R) liquidtight fitting is manufactured from weather-resistant thermoplastic materials and is suitable for indoor or outdoor corrosive environments. The BULLET(R) fitting is resistant to detergents, cleaners, oils, sanitizers, paints, cutting fluids and wire pulling compounds -- just about any liquid usually found in industrial, plant or marine environments. It also surpasses industry standards for cold impact and simulated hammer blows. Ease of installation. * Elongated gland nut offers additional strain relief for 90 pull and easy hand grip C The BULLET(R) fitting is economical because it can be used over and over again without sacrificing the quality of the original seal. When used with the XTRA FLEX(R) raceway system, you can meet most machine or industrial requirements where liquidtight protection is needed. CAT. NO. FIG. LT38P LT438P LT938P LT50P LT450P LT950P LT75P LT475P LT975P LT100P LT4100P LT9100P LT125P LT4125P LT9125P LT150P LT4150P LT9150P LT200P LT4200P LT9200P 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 TRADE A .015 SIZE (.040) (IN.) (IN.) (MM) 8 .570 (14.48) 2 .570 (14.48) 4 .582 (14.78) 1 .726 (18.44) 114 .750 (19.05) 112 .767 (19.48) 2 .794 (20.17) 3 1 3 C .015 (0.40) MIN. ACROSS THROAT *B .035 (0.90) CORNERS DIA. D (IN.) (MM) (IN.) (MM) (IN.) (MM) 1.595 (40.51) 2.012 (51.10) 1.380 (35.05) 1.636 (41.55) 2.092 (53.14) 1.489 (37.82) 1.757 (44.63) 2.452 (62.28) 1.790 (45.47) 1.923 (48.84) 2.684 (68.17) 2.104 (53.44) 2.164 (54.97) 3.264 (82.91) 2.564 (65.13) 2.353 (59.77) 3.605 (91.57) 2.854 (72.49) 2.605 (66.17) 4.210 (106.93) 3.432 (87.17) E THREAD NPT (IN.) 1.354 (34.39) .417 (10.59) 1.448 (36.78) .550 (13.97) 1.740 (44.20) .740 (18.80) 2.068 (52.53) .940 (23.88) 1-1112 2.494 (63.35) 1.257 (31.93) 114-1112 2.784 (70.71) 1.453 (36.91) 112-1112 3.362 (85.39) 1.883 (47.83) 2-8 2-14 1 2-14 1 4-14 3 F* (IN.) (MM) APPROX. - 1.534 (38.95) 1.880 (47.75) - 1.590 (40.39) 1.986 (50.44) - 1.821 (46.25) 2.212 (56. ) - 2.034 (51.66) 2.508 (63.70) - 2.385 (60.58) 2.856 (72.54) - 2.604 (66.14) 3.144 (79.86) - 3.050 (77.47) 3.675 (93.34) * After Assembly UL File No. E-23018 CSA File No. 52391 FIGURE 3 (90 DEGREE) United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 Canada Tel: 450.347.5318 Fax: 450.347.1976 Technical Services Tel: 888.862.3289 www.tnb.com A-123 XTRA FLEX(R) System -- Conduit, Tubing, Fittings for Non-Metallic Liquidtight Conduit Table 1 -- Behavior of EMS20-1B.1 IN: Aqueous Solutions of Inorganic Salts at Room Temperature SALT SOLUTIONS 10% Ammonium Chloride 10% Aluminum Chloride 10% Sodium Hypochlorite (0.1% Cl 2) 10% Calcium Chloride 10% Chrome Alum 10% Ferric Chloride 5% Potassuim Dichromate 10% Potassium Nitrate 1% Potassium Permanganate 10% Copper Sulfate VISUAL CHANGE RATINGS* Unchanged Unchanged White coating after 18 days Unchanged Unchanged Unchanged yellowing Unchanged yellowing Unchanged Decomposed Unchanged F F G F G P P G NR G 10% Magnesium Chloride 10% Magnanese Sulfate 10% Sodium Sulfate 10% Sodium Bisulfite 5% Mercuric Chloride 10% Zinc Chloride VISUAL CHANGE RATINGS* Unchanged Unchanged Unchanged Unchanged Swelled Unchanged G G G G P F * These abbreviations are used for the ratings: E - Excellent P - Poor G - Good NR - Not Recommended F - Fair S - Solvent Table 2 -- Behavior of EMS20-1B.1 IN: Table 3 -- Behavior of EMS20-1B.1 IN: Acids, Bases, Halogens, etc. Organic Solvents at Room Temperature REAGENT Sulfuric Acid (Conc) Sulfuric Acid (Dilute) Hydrochloric Acid (Conc) Hydrochloric Acid (Dilute) Hydrochloric Acid (20-40%) Phosphoric Acid (Conc) Nitric Acid (Conc) Acetic Acid (Conc) Acetic Acid (Conc) Acetic Acid (Dilute) Formic Acid (Conc) Formic Acid (Dilute) Chlorine Bromine Phenol O-Chlorophenol m-Chlorophenol p-Chlorophenol Cresol Dimethylformamide gamma-Butyrolactone Xylenols Sodium Hydroxide (1%) Sodium Hydroxide (5%) Sodium Hydroxide (5%) Sodium Hydroxide (10%) Sodium Hydroxide (10%) Potassium Hydroxide (5%) Potassium Hydroxide (5%) Potassium Hydroxide (10%) Potassium Hydroxide (10%) Hydrogen Peroxide (0.5%) Hydrogen Peroxide (1%) Hydrogen Peroxide (3%) Hydrogen Peroxide (10%) Hydrogen Peroxide (30%) TEMP F VISUAL CHANGE 75 75 75 75 73 75 75 75 200 75 75 75 - - 75 75 75 75 75 75 75 75 73 73 158 73 158 73 158 73 158 73 73 73 73 73 Dissolves Partially dissolves Dissolves Partially dissolves Etched after 1 sec. Dissolves Dissolves Partially Dissolves Dissolves Etched Dissolves Partially Dissolves Strong Attack Strong Attack Dissolves Dissolves Dissolves Dissolves Dissolves Strong Attack Strong Attack Dissolves Unchanged Minimal effect Minimal effect Minimal effect Some "crazing" after 30 days Minimal effect Minimal effect Minimal effect Some "crazing" after 30 days Unchanged Brittle after 54 days Brittle after 54 days Degrades Degrades * These abbreviations are used for the ratings: E - Excellent P - Poor G - Good NR - Not Recommended F - Fair S - Solvent A-124 SALT SOLUTIONS www.tnb.com United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 RATINGS* S, NR P, NR S, NR P, NR P S, NR S, NR P, NR S, NR F, NR S, NR P, NR NR NR S, NR S, NR S, NR S, NR S, NR NR NR S, NR E E E E P E E E P G NR NR NR NR REAGENT Benzyl Alcohol Butyl Alcohol Ethyl Alcohol Isopropyl Alcohol Methyl Alcohol Butyl Acetate Ethyl Acetate Methyl Acetate Amyl Acetate Ether (Diethyl) Tetrahydrofuran Acetone Benzaldyhyde Cyclohexanone Dichlorethylene Trichlorethylene Perchlorethylene Dichlormethane Chloroform Carbon Tetrachloride Carbon Disulfide Pyridine Benzene Monochlorbenzene Toluene Xylene Kerosene Turpentine Tetralin Decalin Gasoline Petroleum Mineral Oil Resorcinol VISUAL CHANGE RATINGS* Coarse surface after 2 days Temporary loss of stiffness Temporary loss of stiffness Temporary loss of stiffness Temporary loss of stiffness Temporary loss of stiffness Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged Temporary loss of stiffness Temporary loss of stiffness Unchanged Temporary loss of stiffness Temporary loss of stiffness Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged Unchanged Dissolves NR G G G G G E E E E E E E E E G G E G G E E E E E E E E E E E E E NR * These abbreviations are used for the ratings: E - Excellent P - Poor G - Good NR - Not Recommended F - Fair S - Solvent Canada Tel: 450.347.5318 Fax: 450.347.1976 Technical Services Tel: 888.862.3289 XTRA FLEX(R) System -- Conduit, Tubing, Fittings for Non-Metallic Liquidtight Conduit Metallic Bullet(R) Liquidtight Connectors for T&B LTC Non-Metallic Liquidtight Conduit Type B and T&B EFC Flexible Tubing A B C Figure Figure 1 A CAT. NO. FIG. TRADE SIZE (IN.) LT38M LT438M LT938M LT50M LT450M LT950M LT75M LT475M LT975M LT100M LT4100M LT9100M LT125M LT4125M LT9125M LT150M LT4150M LT9150M LT200M LT4200M LT9200M 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 -- 3 8 -- -- 1 2 -- -- 3 4 -- -- 1 -- -- 114 -- -- 112 -- -- 2 -- A .030 (.80) (IN.) (MM) *B .060 (1.50) (IN.) (MM) C .045 (1.15) (IN.) (MM) D (IN.) (MM) 1.156 (29.4) -- 1.375 (34.9) -- 1.656 (42.1) -- 1.875 (47.6) -- 2.375 (60.3) -- 2.750 (69.8) -- 3.468 (88.1) -- 1.500 (38.1) 1.962 (49.8) 1.312 (33.3) 1.562 (39.7) 1.875 (47.6) 1.437 (36.5) 1.625 (41.2) 2.125 (54.0) 1.750 (44.4) 2.062 (52.4) 2.250 (57.1) 1.937 (49.2) 2.500 (63.5) 2.750 (69.8) 2.500 (63.5) 2.687 (68.2) 2.750 (69.8) 2.812 (71.4) 3.062 (77.8) 3.875 (98.4) 3.500 (88.9) 0.562 (14.3) 0.562 (14.3) 0.625 (15.9) 0.562 (14.3) 0.562 (14.3) 0.625 (15.9) 0.625 (15.9) 0.562 (14.3) 0.625 (15.9) 0.750 (19.0) 0.812 (20.6) 0.812 (20.6) 0.812 (20.6) 0.812 (20.6) 0.812 (20.6) 0.812 (20.6) 0.812 (20.6) 0.812 (20.6) 0.812 (20.6) 0.875 (22.2) 0.875 (22.2) -- -- 1.375 (34.9) -- -- 1.562 (39.7) -- -- 1.750 (44.4) -- -- 2.187 (55.5) -- -- 2.750 (69.8) -- -- 2.937 (74.6) -- -- 3.437 (87.3) THREAD NPT (IN.) 2-14 -- -- 1 2-14 1 -- 4-14 3 -- 1-1112 -- 114-1112 -- 112-1112 -- 2-1112 -- * After Assembly UL File No. E-23018 B CSA File No. 52391 Suggested Specification: C Where liquidtight flexible non-metallic conduit (UL Type B) or liquidtight flexible non-metallic tubing is terminated to a box or enclosure, the metallic connectors used shall be able to be installed without disassembly and provide a positive installation criteria. In the installed condition, the connector must provide a seal, meeting watertight requirements of NEMA Type 4 and Type 6 enclosures with conduit and NEMA Type 4 enclosures with tubing. Installed connectors shall be as manufactured by Thomas & Betts LT38M series. Figure 2 Figure D Material: Body/Gland -- Steel/MI Insert -- Nylon A B C NPT Thread NPT Thread Figure Figure 3 United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 Canada Tel: 450.347.5318 Fax: 450.347.1976 Technical Services Tel: 888.862.3289 www.tnb.com A-125 XTRA FLEX(R) System -- Conduit, Tubing, Fittings for Non-Metallic Liquidtight Conduit Material -- PVC When you have a conduit application in a liquidtight environment, it's time to load up the T&B Bullet(R). Thomas & Betts introduces the ISO Metric Bullet(R) liquidtight fittings for use with the 38", 12" and 34" XTRA FLEX(R) EFC and LTC non-metallic liquidtight conduit series. The T&B Bullet(R) liquidtight fitting and EFC non-metallic conduit are suited for OEM applications as in the machine tool industry where environments include continuous motion, vibration and exposure to moisture, oil, dirt and dust. The T&B Bullet(R) liquidtight fitting and LTC non-metallic conduit are also suitable for construction applications where ISO metric threading and liquidtight systems are installed. The XTRA FLEX(R) system offers a lightweight, liquidtight flexible conduit solution for industrial applications. The XTRA FLEX(R) system enables fast, easy installation and high performance in demanding industrial applications. ISO Metric Bullet(R) Liquidtight Fitting Non-Metallic CAT. NO. LT38P-ISO20 LT50P-ISO20 LT75P-ISO25 LT938P-ISO20 LT950P-ISO20 LT975M-ISO25 ANGLE OF FITTING Straight Straight Straight 90 90 90 CONDUIT SIZE 8" 2" 3 4" 3 8" 1 2" 3 4" KNOCKOUT SIZE UNIT PACKAGE STANDARD PACKAGE UPC NUMBER 2" 2" 3 4" 1 2" 1 2" 3 4" 25 25 25 25 25 10 100 100 50 50 50 50 786210-66444 786210-66613 786210-66443 786210-66612 786210-66640 786210-66611 3 1 1 1 *Testing: UL and CSA listed; NEMA 4, 6, 6P; IP 67 when used with LTC conduit or EFC tubing with installed T&B Bullet liquidtight fitting. A-126 www.tnb.com United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 Canada Tel: 450.347.5318 Fax: 450.347.1976 Technical Services Tel: 888.862.3289 XTRA FLEX(R) System -- Conduit, Tubing, Fittings for Non-Metallic Liquidtight Conduit Material -- PVC Maximum flexibility for tight applications! Corrugated Flexible Non-Metallic Tubing * OEM grade -- UL Recognized * PVC material Recommended industrial applications * Protection of fiber optic cable * Black color standard * Installation of instrumentation and control cable * Extremely fast installation * Indoor/outdoor lighting * Liquidtight with specified fittings * Packaging equipment * Good tensile strength provides excellent pullout protection * Marine and shipboard wiring * Smooth inner diameter allows easy wire pulling * Flexing component wiring protection on robots, graphic arts equipment, etc. * Broad operating temperature range: 18 C to +60 C (-2 F to +140 F). * Flammability Rating VW-1 (Vertical Wire) UL224 I.D. O.D. (R) CAT. NO. CONDUIT SIZE MIN. MAX. MIN. MAX. EFC025* EFC038 EFC050 EFC075 EFC100 EFC125 EFC150 EFC200 4" 8" 1 2" 3 4" 1" 114" 112" 2" .390 .484 .622 .820 1.041 1.380 1.575 2.020 .405 .504 .642 .840 1.066 1.410 1.600 2.045 .560 .690 .820 1.030 1.290 1.630 1.865 2.340 .575 .710 .840 1.050 1.315 1.660 1.900 2.375 1 3 * Not CSA Certified. Underwriters Recognized UL File No. 96548 I.D. (IN.) O.D. (IN.) CAT. NO. LTC - W/O SUFFIX -1 -2 AVAILABLE COLORS COLOR OF CONDUIT Black Orange Blue CSA File No. 067241 See technical data next page. Use with Bullet(R) Liquidtight Fittings. United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 Canada Tel: 450.347.5318 Fax: 450.347.1976 Technical Services Tel: 888.862.3289 www.tnb.com A-127 XTRA FLEX(R) System -- Conduit, Tubing, Fittings for Non-Metallic Liquidtight Conduit Material -- PVC NEW! Now available in reels. XTRA FLEX(R) Conduit The XTRA FLEX(R) system offers a lightweight, liquidtight flexible conduit solution for demanding applications. The XTRA FLEX(R) system ensures fast, easy installations and long-lasting, high performance in a variety of environments. Now, XTRA FLEX(R) Conduit is available on reels. Large users can save space and reduce waste, while taking advantage of the convenience of stocking bulk in lengths. Utilizing our new coupling design to connect 100-ft. lengths, Thomas & Betts now offers reel lengths up to 1,000 feet. * Fast installation -- even in tight, cramped spaces * Smooth inner diameter enables easy wire pulling * Smooth outer jacket -- approved for outdoor use, sunlight resistant and oil resistant * Tested to CSA and UL requirements * Lightweight and liquidtight * Marked at 1-foot intervals for fast, easy measuring . . . . . . . . . . . . Specifications . . . . . . . . . . . . * Material: PVC * Colors Available: Black, Gray * Temp. Range: -18 C to +105 C (-2 F to +221 F) Black -18 C to +80 C (-2 F to +176 F) Gray * Flammability Rating: UL 1660 * Listings: UL Listed, CSA Certified Please contact your Thomas & Betts sales representative regarding custom colors and combinations. (R) XTRA FLEX(R) Liquidtight Conduit/Reel Lengths CAT. NO. (R) SIZE DESCRIPTION MIN. I.D. MAX. I.D MIN. O.D MAX. O.D. REEL LENGTH MIN. ORDER 8" 1 2" 1 2" 1 2" 1" 1" Gray Type B LT Conduit Gray Type B LT Conduit Black Type B LT Conduit Gray Type B LT Conduit Gray Type B LT Conduit Black Type B LT Conduit .484" .622" .622" .622" 1.041" 1.041" .504" .642" .642" .642" 1.066" 1.066" .690" .820" .820" .820" 1.290" 1.290" .710" .840" .840" .840" 1.315" 1.315" 500 ft. 500 ft. 500 ft. 1,000 ft. 500 ft. 500 ft. 1,500 1,500 Stock 2,000 1,500 1,500 LTC038GY-500 LTC050GY-500 LTC050-500 LTC050GY-1000 LTC100GY-500 LTC100-500 3 UL Listed, UL File No. 95745 CSA Certified, CSA File No. LL 80349 A-128 www.tnb.com United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 Canada Tel: 450.347.5318 Fax: 450.347.1976 Technical Services Tel: 888.862.3289 XTRA FLEX(R) System -- Conduit, Tubing, Fittings for Non-Metallic Liquidtight Conduit Material -- PVC Smooth, sunlight- and oil-resistant outer jacket, approved for outdoor use! Smooth Liquidtight Non-Metallic Conduit Type B (R) (R) Industrial Grade * Industrial grade -- UL Listed/CSA Certified * PVC material * Liquidtight non-metallic conduit Type B * Black color standard * Fast installation -- even in tight, cramped spaces * Smooth inner diameter enables easy wire pulling CAT. NO. CONDUIT SIZE MIN. LTC038 LTC050 LTC075 LTC100 LTC125 LTC150 LTC200 8" 2" 3 4" 1" 114" 112" 2" .484 .622 .820 1.041 1.380 1.575 2.020 3 1 I.D. (IN.) MAX. O.D. (IN.) MIN. MAX. .504 .642 .840 1.066 1.410 1.600 2.045 .690 .820 1.030 1.290 1.630 1.865 2.340 .710 .840 1.050 1.315 1.660 1.900 2.375 * Tested to CSA and UL requirements * Lightweight and liquidtight (R) Commercial Grade * Temperature range of -18 C to +105 C (-2 F to +221 F) * UL1660 flammability rating CAT. NO. * Marked at 1-ft. intervals for fast, easy measuring and cutting LTC038GY LTC050GY LTC075GY LTC100GY LTC125GY LTC150GY LTC200GY Recommended industrial applications * Machine tools * Motor hookups * Food processing equipment * Extensions from wireways * Sensor and microswitch wiring in control consoles I.D. I.D. O.D. XTRA FLEX(R) Conduit and Tubing Technical Data* (R) CONDUIT SIZE MIN. 8" 2" 3 4" 1" 114" 112" 2" .484 .622 .820 1.041 1.380 1.575 2.020 3 1 I.D. (IN.) MAX. O.D. (IN.) MIN. MAX. .504 .642 .840 1.066 1.410 1.600 2.045 .690 .820 1.030 1.290 1.630 1.865 2.340 .710 .840 1.050 1.315 1.660 1.900 2.375 Rated at 600V UL Listed, UL File No. E95745 XTRA FLEX(R) Type B suitable for use in hazardous location (for LTC Series only) where general purpose equipment is specifically permitted by the NEC; Class I Div. 2; Class II, Div. 1 & 2; Class III, Div. 1 & 2, NEC 501-4(b); 502-4(a)(b); 5033(a)(b). CSA Certified, CSA File No. LL80349 See technical data below. Use with Bullet(R) Liquidtight Fittings. LTFNMC = Liquidtight flexible non-metallic conduit LTFNMT = Liquidtight flexible non-metallic tubing XTRA FLEX(R) CONDUIT & TUBING SIZE RANGE STYLE COLOR LTC038 Series UL Type B LTFNMC Black Black 3 8"-2" LTC038-1, -2 Series UL Type B LTFNMC Orange, Blue 1 2"-1" LTC038GY Series UL Type B LTFNMC Gray 3 8"-2" Black Orange, Blue 1 4"-2" 2"-1" EFC025 Series** LTFNMT EFC025-1, -2** LTFNMT Series 1 UL TEMP RATING CSA TEMP RATING 105 C Dry 75 C-18 C 60 C Wet -- 70 C Oil 105 C Dry -- 60 C Wet -- 70 C Oil 80 C Dry -- 60 C Wet -- 70 C Oil 105 C 75C-18 C 105 C -- VOLTAGE RATING UL OIL RESISTANT UL OUTDOOR UL DIRECT BURIAL 600V Yes Yes Yes 600V Yes No Yes 600V Yes Yes Yes 300V 300V Yes Yes Yes No No No AVAILABLE COLORS COLOR OF COLOR OF CONDUIT MARKING LTC - CAT. NO. W/O SUFFIX -1 -2 Black Orange Blue Orange Black Black * For a complete test report, contact Customer Service. ** UL Component Recognized United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 Canada Tel: 450.347.5318 Fax: 450.347.1976 Technical Services Tel: 888.862.3289 www.tnb.com A-129 XTRA FLEX(R) System -- Conduit, Tubing, Fittings for Non-Metallic Liquidtight Conduit Material -- PVC XTRA FLEX(R) Non-Metallic Conduit Type B and Flexible Tubing A = SATISFACTORY CHEMICAL B = BE EXPECTED TO CHANGE CHEMICAL C = NOT RECOMMENDED CHEMICAL Acetate Solvents . . . . . . . . . . . . . . . . . . . C Acetic Acid (10%). . . . . . . . . . . . . . . . . . A Acetic Acid (Glacial) . . . . . . . . . . . . . . . . B Acetone. . . . . . . . . . . . . . . . . . . . . . . . . . C Acrylonitrile. . . . . . . . . . . . . . . . . . . . . . . A Adipic Acid . . . . . . . . . . . . . . . . . . . . . . . A Alcohol Butyl. . . . . . . . . . . . . . . . . . . . . . A Alcohol Ethyl. . . . . . . . . . . . . . . . . . . . . . A Alcohol Isopropyl . . . . . . . . . . . . . . . . . . A Alcohol Methyl . . . . . . . . . . . . . . . . . . . . A Aluminum Acetate . . . . . . . . . . . . . . . . . . A Aluminum Chloride. . . . . . . . . . . . . . . . . A Aluminum Hydroxide . . . . . . . . . . . . . . . A Aluminum Sulfate . . . . . . . . . . . . . . . . . . A Aliyl Chloride . . . . . . . . . . . . . . . . . . . . . C Ammonia (0.88S.G.Aqueous) . . . . . . . . . A Ammonia (Dry Gas) . . . . . . . . . . . . . . . . A Ammonia (Liquid). . . . . . . . . . . . . . . . . . C Ammonium Chloride. . . . . . . . . . . . . . . . A Ammonium Hydroxide . . . . . . . . . . . . . . A Animal Oils . . . . . . . . . . . . . . . . . . . . . . . A Amyl Acetate . . . . . . . . . . . . . . . . . . . . . . C Aniline Oils . . . . . . . . . . . . . . . . . . . . . . . B Aromatic Hydrocarbons . . . . . . . . . . . . . C Asphalt . . . . . . . . . . . . . . . . . . . . . . . . . . C ASTM Fuel A. . . . . . . . . . . . . . . . . . . . . . B ASTM Fuel B . . . . . . . . . . . . . . . . . . . . . C ASTM #1 Oil . . . . . . . . . . . . . . . . . . . . . . A ASTM #3 Oil . . . . . . . . . . . . . . . . . . . . . . B Barium Chloride . . . . . . . . . . . . . . . . . . . A Barium Hydroxide . . . . . . . . . . . . . . . . . . A Barium Sulfide . . . . . . . . . . . . . . . . . . . . A Benzene . . . . . . . . . . . . . . . . . . . . . . . . . C Benzine . . . . . . . . . . . . . . . . . . . . . . . . . . B Bordeaux Mixture . . . . . . . . . . . . . . . . . . A Borax. . . . . . . . . . . . . . . . . . . . . . . . . . . . A Boric Acid . . . . . . . . . . . . . . . . . . . . . . . . A Brine . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Bromine Traces . . . . . . . . . . . . . . . . . . . . C Butyl Acetate . . . . . . . . . . . . . . . . . . . . . . C Calcium Hydroxide . . . . . . . . . . . . . . . . . A Calcium Hypochlorite . . . . . . . . . . . . . . . A Carbonic Acid . . . . . . . . . . . . . . . . . . . . . B Carbon Dioxide . . . . . . . . . . . . . . . . . . . . A Carbon Disulphite. . . . . . . . . . . . . . . . . . C Carbon Monoxide . . . . . . . . . . . . . . . . . . A Carbon Tetrachloride. . . . . . . . . . . . . . . . C Casein. . . . . . . . . . . . . . . . . . . . . . . . . . . A Chlorine (Dry). . . . . . . . . . . . . . . . . . . . . A Chlorine (Wet Gas) . . . . . . . . . . . . . . . . . B Chlorine (Water) . . . . . . . . . . . . . . . . . . . C Chlorobenzene . . . . . . . . . . . . . . . . . . . . C Chlorinated Hydrocarbons . . . . . . . . . . . C Chloroform . . . . . . . . . . . . . . . . . . . . . . . C Chromic Acid . . . . . . . . . . . . . . . . . . . . . A Citric Acid . . . . . . . . . . . . . . . . . . . . . . . . A Coal Tar . . . . . . . . . . . . . . . . . . . . . . . . . C Copper Chloride . . . . . . . . . . . . . . . . . . . A Copper Nitrate. . . . . . . . . . . . . . . . . . . . . A Copper Sulphate . . . . . . . . . . . . . . . . . . . A Cottonseed Oil . . . . . . . . . . . . . . . . . . . . . . . B Creosote . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Cresol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Cresylic Acid. . . . . . . . . . . . . . . . . . . . . . . . . C Cyclohexane . . . . . . . . . . . . . . . . . . . . . . . . . A Cyclohexanone . . . . . . . . . . . . . . . . . . . . . . . C DDT Weed Killer . . . . . . . . . . . . . . . . . . . . . . A Detergent Synthetic . . . . . . . . . . . . . . . . . . . . A Developers Photographic . . . . . . . . . . . . . . . A Dextrin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Dextrose . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Dibutyle Phthalate. . . . . . . . . . . . . . . . . . . . . C Dichlorobenzene . . . . . . . . . . . . . . . . . . . . . . C Diesel Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . B Diethylene Glycol . . . . . . . . . . . . . . . . . . . . . A Diethyl Ether . . . . . . . . . . . . . . . . . . . . . . . . . C Di-isodecyl Phthalate . . . . . . . . . . . . . . . . . . C Dioctyle Phthalate . . . . . . . . . . . . . . . . . . . . . C Emulsifiers . . . . . . . . . . . . . . . . . . . . . . . . . . A Emulsions Photographic . . . . . . . . . . . . . . . . A Ethyl Acetate . . . . . . . . . . . . . . . . . . . . . . . . . C Ethylene Dichloride. . . . . . . . . . . . . . . . . . . . C Ethylene Glycol . . . . . . . . . . . . . . . . . . . . . . . A Fatty Acid . . . . . . . . . . . . . . . . . . . . . . . . . . . A Ferric Chloride . . . . . . . . . . . . . . . . . . . . . . . A Ferric Sulphate . . . . . . . . . . . . . . . . . . . . . . . A Ferrous Chloride . . . . . . . . . . . . . . . . . . . . . . A Ferrous Sulphate. . . . . . . . . . . . . . . . . . . . . . A Fixing Solution, Photographic. . . . . . . . . . . . A Fluorine . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Formaldehyde (40%) . . . . . . . . . . . . . . . . . . C Formic Acid (40%) . . . . . . . . . . . . . . . . . . . . A Formic Acid (50%) . . . . . . . . . . . . . . . . . . . . B Formic Acid (100%) . . . . . . . . . . . . . . . . . . . C Fuel Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Glacial Acetic Acid . . . . . . . . . . . . . . . . . . . . B Glucose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Glycerine . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Grape Sugar . . . . . . . . . . . . . . . . . . . . . . . . . A Grease . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Heptane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Hexane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Hydrobromic Acid . . . . . . . . . . . . . . . . . . . . . A Hydrochloric Acid (10%) . . . . . . . . . . . . . . . A Hydrochloric Acid (40%) . . . . . . . . . . . . . . . A Hydrofluoric Acid (10%) . . . . . . . . . . . . . . . . A Hydrofluoric Acid (40%) . . . . . . . . . . . . . . . . B Hydrofluoboric Acid . . . . . . . . . . . . . . . . . . . A Hydrofluosilicic Acid. . . . . . . . . . . . . . . . . . . A Hydrogen Peroxide . . . . . . . . . . . . . . . . . . . . A Hydrogen Sulphide . . . . . . . . . . . . . . . . . . . . A Iso-octan . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Isopropyl Acetate . . . . . . . . . . . . . . . . . . . . . C Kerosene . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Ketones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Lactic Acid (10%) . . . . . . . . . . . . . . . . . . . . . A Lactic Acid (100%) . . . . . . . . . . . . . . . . . . . . C Lacquer Solvents. . . . . . . . . . . . . . . . . . . . . . B Linseed Oil . . . . . . . . . . . . . . . . . . . . . . . . . . A Lubricating Oils. . . . . . . . . . . . . . . . . . . . . . . A Magnesium Chloride. . . . . . . . . . . . . . . . . . . A Magnesium Hydroxide . . . . . . . . . . . . . . . . . A Magnesium Sulphate . . . . . . . . . . . . . . . . . . A Malic Acid. . . . . . . . . . . . . . . . . . . . . . . . . . . A Methyl Acetate . . . . . . . . . . . . . . . . . . . . . . . C Methyl Bromide . . . . . . . . . . . . . . . . . . . . . . C Methyl Ethyl Ketone . . . . . . . . . . . . . . . . . . . C Methylene Chloride. . . . . . . . . . . . . . . . . . . . C Mineral Oils . . . . . . . . . . . . . . . . . . . . . . . . . A Monochlorobenzene . . . . . . . . . . . . . . . . . . . C Naphtha. . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Naphthalene . . . . . . . . . . . . . . . . . . . . . . . . . C Nitric Acid (10%) . . . . . . . . . . . . . . . . . . . . . A Nitric Acid (40%) . . . . . . . . . . . . . . . . . . . . . A Nitric Acid (70%) . . . . . . . . . . . . . . . . . . . . . C Nitrobenzene . . . . . . . . . . . . . . . . . . . . . . . . . C Nitrogen Fertilizers . . . . . . . . . . . . . . . . . . . . A Oleic Acid . . . . . . . . . . . . . . . . . . . . . . . . . . . A Oxalic Acid . . . . . . . . . . . . . . . . . . . . . . . . . . A Palmitic Acid. . . . . . . . . . . . . . . . . . . . . . . . . A Paraffin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Pentane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Perchloroethylene . . . . . . . . . . . . . . . . . . . . . C Phenol. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B Phosphoric Acid . . . . . . . . . . . . . . . . . . . . . . A Pitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Potassium Hydroxide . . . . . . . . . . . . . . . . . . A Propane. . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Sea Water . . . . . . . . . . . . . . . . . . . . . . . . . . . A Sodium Hydroxide (10%) . . . . . . . . . . . . . . . A Sodium Hydroxide (50%) . . . . . . . . . . . . . . . A Sodium Cyanide . . . . . . . . . . . . . . . . . . . . . . A Soybean Oil. . . . . . . . . . . . . . . . . . . . . . . . . . A Stearic Acid. . . . . . . . . . . . . . . . . . . . . . . . . . A Styrene . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Sulphur Dioxide (Dry). . . . . . . . . . . . . . . . . . A Sulphur Dioxide (Moist) . . . . . . . . . . . . . . . . B Sulphur Dioxide (Liquid) . . . . . . . . . . . . . . . C Sulphuric Acid (45%) . . . . . . . . . . . . . . . . . . A Sulphuric Acid (60%) . . . . . . . . . . . . . . . . . . B Sulphuric Acid (98%) . . . . . . . . . . . . . . . . . . C Sulphurous Acid (30%) . . . . . . . . . . . . . . . . A Tannic Acid . . . . . . . . . . . . . . . . . . . . . . . . . . A Tartaric Acid . . . . . . . . . . . . . . . . . . . . . . . . . A Tetrahydrofuran . . . . . . . . . . . . . . . . . . . . . . . C Toluene . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Trichlorethylene. . . . . . . . . . . . . . . . . . . . . . . C Triethanolamine. . . . . . . . . . . . . . . . . . . . . . . A Tricresyl Phosphate. . . . . . . . . . . . . . . . . . . . C Turpentine . . . . . . . . . . . . . . . . . . . . . . . . . . . B Urea . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Vinegar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Vinyl Acetate . . . . . . . . . . . . . . . . . . . . . . . . . C Vinyl Chloride. . . . . . . . . . . . . . . . . . . . . . . . C Water. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A Xylene . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C Zinc Chloride . . . . . . . . . . . . . . . . . . . . . . . . A Zinc Sulphate . . . . . . . . . . . . . . . . . . . . . . . . A NOTE: These chemical resistance ratings are based upon information supplied by the raw material manufacturers. It is intended as a general guideline only. To determine specific suitability, samples should be tested by user under actual conditions. Operating Condition: 70 F. A-130 www.tnb.com United States Tel: 901.252.8000 800.816.7809 Fax: 901.252.1354 Canada Tel: 450.347.5318 Fax: 450.347.1976 Technical Services Tel: 888.862.3289