320 Watt Medical Grade Switching Power Supply with PFC PMMK320E series
WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
INPUT SPECIFICATIONS
Input Voltage Range 90-264 VAC; Nom: 100-240VAC
Frequency Range 47-63 Hz
Power Factor Correction 0.95, min. Nom I/P, FL
Inrush Current, typ: 30A @ 115VAC Cold Start, FL*
60A @ 230VAC Cold Start, FL*
Input Current 5.4 Amps max., 90V I/P
1.8 Amps max., 264V I/P
Leakage Current <0.3mA, 240Vin, 50Hz
OUTPUT SPECIFICATIONS
Voltage and Current See Selection Chart
Line Regulation (LL-HL) ±1%, max. (±1.5% 5 Vout)
Load Regulation 10%-FL ±1~1.5%, max.
Preset Accuracy (Note 3) ±1%, typ (±2% 5 Vout)
Ripple/Noise (Notes 1, & 4) See Selection Chart
Over Voltage Protection 130% max. Auto Recovery *
Over Current Protection 160% max. Auto Recovery *
Short Circuit Protection Auto Recover after fault
condition is removed *
Turn On Delay Time <4S
Rise Time <25mS, typ (Nom I/P, FL)
Hold Up Time 20mS, typ (Nom I/P, FL)
Over-Shoot/Under Shoot <10% of Nominal Output
Remote Sense Compensates for up to 0.5V drop
Remote Shutdown Open Collector, Logic “1” = ON
“0” = Off. No Termination necessary
to maintain constant “On” operation
PHYSICAL SPECIFICATIONS
Size 8.03”(L) x 3.86”(W) x 1.57”(H)
Construction Enclosed
Weight 1.75 lb, (794g)
GENERAL SPECIFICATIONS
Isolation (Note 2) I/P-O/P: 5656VDC
I/P-Ground: 2121VDC
O/P-Ground: 707VDC
Insulation Resistance ≥20MΩ
Efciency (FL. Nom I/P) See Selection Chart
Safety UL/cUL: ANSI/AAMI ES60601-1 3rd ed.
CSA C22.2 No. 60601-1 3rd ed.
UL-EU: EN60601-1 3rd ed.
CB: IEC60601-1 3rd ed.
CE: EN60601-1-2
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature -20 to +70°C (See Derate Curve)
Storage Temperature -25 to +85°C *
Relative Humidity 10% to +90%, *
Storage: 5-95%
EMS
Harmonics Class D, 61000-3-2
Fluctuations 61000-3-3
ESD 61000-4-2
RS 61000-4-3
EFT 61000-4-4
Surge 61000-4-5
CS 61000-4-6
MS 61000-4-8
DIPS 61000-4-11
EMI EN55022 Class B
MTBF Mil Std 217F, 25°C 65,000 Hrs, min.
Vibration 4G Peak, 50-500Hz, 3 Axes
Drop Test 70 CM
NOTES
1. All measurements should be made directly at the terminals of the
power supply
2. Isolation for up to 1 minute duration.
3. Preset Accuracy measured at nominal load, 120VAC input.
4. O/P Noise measured directly at the pins/terminals at nominal load,
0.1uF ceramic bypass and 47uF electrolytic, pk-pk @ 20MHz
bandwidth.
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.