CONSTANT CURRENT REGION
Note.4
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT Note.4
OVER VOLTAGE
OVER TEMPERATURE
2500ms, 200ms / 115VAC at full load 500ms, 200ms / 230VAC at full load
12ms at full load 115VAC/230VAC
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
1.7A / 115VAC 0.78A / 230VAC 0.7A / 277VAC
COLD START 65A(twidth=425 s measured at 50% Ipeak) at 230VACμ
<0.75mA / 277VAC
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
-40 ~ +60 (Refer to "Derating Curve")℃
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
252.3Khrs min. MIL-HDBK-217F (25 )℃
Refer to mechanical specification
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage, and the output power must be more than 60% rated output power.
This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8.To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
1.53Kg; 8pcs/13.8Kg/1.61CUFT
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
160W Single Output Switching Power Supply
MEAN WELL patented housing design
(Patent No.: )CN201220314551
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
High efficiency up to 93.5%
Protections: Short circuit / Over current / Over voltage / Over temperature
OCP point adjustable through internal potentiometer
IP67 / IP65 design for indoor or outdoor installations
Suitable for dry / damp / wet locations
5 years warranty, Tc70 40000hrs℃
â– Features :
HBG-160 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, recovers automatically after temperature goes down
UL8750,CSA C22.2 No.250.13-12,EN61347-1,EN61347-2-13 approved, esign refer to EN60950d
92%
±2.0%
±0.5%
±1.0%
24V
14.4 ~ 24V
6.5A
156W
200mVp-p
HBG-160-24
28 ~ 34V
EMC IMMUNITY
EMC EMISSION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
92%
36V
21.6 ~ 36V
4.4A
158.4W
300mVp-p
HBG-160-36
41 ~ 47V
93.5%
60V
36 ~ 60V
2.6A
156W
300mVp-p
HBG-160-60
65 ~ 75V
HBG-160-60 A
A : IP65 rated. Output constant current level can be adjusted through internal potentiometer.
Blank : IP67 rated. Cable for I/O connection.
E : IP67 rated. Can be fixed by steel support.(option)
B : IP67 rated. output constant current lever can be adjusted through output cable with 1-10V,PWM signal and Resistance
IP65 IP67
Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3≧
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547,light industry level (surge 4KV), criteria A
93%
48V
28.8 ~ 48V
3.3A
158.4W
300mVp-p
HBG-160-48
54 ~ 62V
CURRENT ADJ. RANGE 3.9 ~ 6.5A 2.6 ~ 4.4A 1.98 ~ 3.3A
Can be adjusted by internal potentiometer A type only
1.6 ~ 2.6A
110
SELV
FMM
Bauar
Sicherheit
egel gema
t gepruft
od
be
www.
ID 2000000000
tuv.com
wac g
os
TOTAL HARMONIC DISTORTION
THD< 20% when output loading 60% at 115VAC/230VAC input and output loading 75% at 277VAC input≧≧
MAX. No. of PSUs on 16A
CIRCUIT BREAKER 4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC
File Name:HBG-160-SPEC 2015-05-28