VDRT-240-24 Single Output DIN Rail Power Supply
DC output voltage 24V
Output rated current 10A
Output current range 0~10A
Rated output power 240W
Ripple & noise 80mVp-p
Voltage adj. range 24~28V
Voltage tolerance ±1.0%
Line regulation ±0.5%
Load regulation ±0.5%
Setup, rise, hold time 1200ms, 40ms, 20ms/400VAC 800ms, 40ms, 40ms/500VAC at full load
Input voltage range Three-Phase 340 ~ 550VAC 480 ~ 780VDC
Frequency range 47 ~ 63Hz
Efficiency 89%
AC current 0.95A/400VAC 0.75A/500VAC
Inrush current Cold start 50A
Leakage current <3.5mA / 530VAC
Overload protection 105 ~ 150% rated output power
type : Constant current limiting, recovers automatically after fault condition is removed
Over voltage protection 30~36V Protection type : Shut down o/p voltage, re-power on to recover
Over temp. protection 100°C ±5°C (TSW) Detect on heatsink of power switch
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
Working temperature -20 ~ +70°C (Refer to output load derating curve)
Working humidity 20 ~ 90% RH non-condensing
Storage temp., humidity -40 ~ +85°C , 10 ~ 95% RH
Temperature coefficient ±0.03%/°C (0 ~ 50°C)
Vibration 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
Safety standards UL508, TUV EN60950-1 Approved
Withstand voltage I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC for 1 min.
Isolation resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC min.
EMI conduction & radiation Compliance to EN55011 (CISPR11), EN55022 (CISPR22), EN61204-3 Class B
Harmonic current Compliance to EN61000-3-2,-3
EMS immunity Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN61204-3, EN61000-6-2 (EN50082-2)
Heavy industry level, criteria A
MTBF 114.6Khrs min. MIL-HDBK-217F (25°C)
Dimensions 4.94x4.93x3.94 inches (125.5x125.2x100mm)
Weight 2.87 lbs (1.3Kg Kgs)
Notes: 1. All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient
2. Tolerance includes set up tolerance, line regulation, load regulation
3. Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor
4. Dual phase operation; derating of 20% is required
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most
up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for customer ’s applications using V-Infinity products other than
repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of standard product warranty.
Features
·Three-Phase AC 340 ~ 550V wide range input
·High efficiency 89% and low dissipation
·Protections:Short circuit/Over load/Over voltage/Over
temperature
·Cooling by free air convection
·Built-in constant current limiting circuit
·Can be installed on DIN rail TS-35/7.5 or 15
·UL 508(industrial control equipment)approved
·EN61000-6-2(EN50082-2) industrial immunity level
·100% full load burn-in test
·3 years warranty