Surface Mount Detection Switch D3SH 63
Surface Mount Detection Switch
D3SH
The smallest detection switch in the
world. (OMRON’s data as of June 2006.)
Ultra small size and ultra low profile contributing to
down-sizing of sets devices.
(3.0 x 3.4 x 0.9 mm (W x D x H))
A unique mechanism enables high contact reliability and
high precision operation.
Horizontal 2-way detection and long stroke for easy
installation are available.
Meet a variety of applications by contact and lever
variations.
Ordering Information
Standard Lever Models
Note: Minimum packing unit is 1,000 pcs./reel.
Long Lever Models
Note: Minimum packing unit is 1,000 pcs./reel.
Model Number Legend
Contact
form
Direction of
Operation
Positioning
Boss
Model Packing
form
SPST-NO
Right With Boss D3SH-A1R Embossed
tape packing
(see note)
Without
Boss
D3SH-A0R
Left With Boss D3SH-A1L
Without
Boss
D3SH-A0L
SPST-NC
Right With Boss D3SH-B1R
Without
Boss
D3SH-B0R
Left With Boss D3SH-B1L
Without
Boss
D3SH-B0L
Contact
form
Direction of
Operation
Positioning
Boss
Model Packing
form
SPST-NO
Right With Boss D3SH-A1R1 Embossed
tape packing
(see note)
Without
Boss
D3SH-A0R1
Left With Boss D3SH-A1L1
Without
Boss
D3SH-A0L1
SPST-NC
Right With Boss D3SH-B1R1
Without
Boss
D3SH-B0R1
Left With Boss D3SH-B1L1
Without
Boss
D3SH-B0L1
D3SH -
1. Contact Form
A: SPST-NO
B: SPST-NC
2. Boss for PCB Positioning
0: without Boss
1: with Boss
3. Lever Length and Direction of Operation
R: Right Operating with standard lever
L: Left Operating with standard lever
R1: Right Operating with long lever
L1: Left Operating with long lever
2 31
64 Surface Mount Detection Switch D3SH
Specifications
Characteristics
Note: 1. The data given above are initial values.
2. The values apply at the total travel position. Contact opening or closing time is within 1ms.
3. The electrical rating applies under the following test conditions:
Ambient Temperature = 20±2°C, Ambient Humidity = 65±5%, Operating frequency = 30 operations/minute
Contact Specifications
Engineering Data
Contact form
SPST-NO
SPST-NC
Note: The cover connects with COM terminal inside.
Packaging Specifications
Electrical Rating (see note 3) 1 mA at 30 VDC (resistive)
Operating speed 1 mm to 300 mm/s
Operating frequency Mechanical: 20 operations/minute max.
Electrical: 20 operations/minute max.
Insulation resistance 100 MΩ min. (at 100 VDC)
Contact resistance 3Ω max.
Dielectric strength 100 VAC for 1 min between terminals of same polarity
Vibration resistance (see note 2) Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance (see note 2) Destruction: 1000 m/s2 (approx. 100 G) max.
Malfunction: 300 m/s2 (approx. 30 G) max.
Life expectancy Mechanical: 150,000 operations min. (20 operations/minute)
Electrical: 100,000 operations min. (20 operations/minute)
Ambient operating temperature –25°C to 85°C (at 60% RH max.) with no icing or condensation
Ambient operating humidity 85% max. (for 5°C to 35°C)
Weight Approx. 0.02 g
Contact Specification Slide
Minimum applicable load 15 μA at 3 VDC
COM N.O COM N.O
N.C COM N.CCOM
12
±0.30
Drawing direction
Standard package Qty 1,000 pcs/reel
Carrier tape (1.8)(18)
Reel
φ
13
φ
380±2
Label Feed direction
Standards Conforms to JEITA
Package Qty 1,000 pcs/reel
Surface Mount Detection Switch D3SH 65
Dimensions and Operating Characteristics
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.15 mm applies to all dimensions
2. The operating characteristics are for operation in the A direction () and B direction (, ).
Standard Lever Models
z
Model D3SH-@@R
D3SH-@@L
Operating force (OF) max. 31 gf
Free position (FP) 5.4 ± 0.2 mm
Operating position (OP) 5.0 ± 0.2 mm
Total travel position (TTP) 3.8 ± 0.15 mm
PCB mounting land Dimension (Reference)
(View from switch top)
4.4
2.2
1.1 (2.2)
A
B
2.3
0.68
0.9
±0.05
(0.9)
TTP
OP
FP
3
center of rotation
0.36
0.39
3.1 0.8
R0.2
0.4
1.65
0.25
0.4
0.55
1.65
1.1
0.5
Right operating – without Boss
D3SH-@0R
PCB mounting land Dimension (Reference)
(View from switch top)
(2.2) 1.1
4.4
2.2
0.68
0.9±0.05
(0.9)
0.39
0.36
2.3
3
TTP
OP
FP
center of rotation
0.8
R0.2
0.25
3.1
1.65
0.4
0.5
1.1 0.55
1.65
0.4
A
B
Left operating – without Boss
D3SH-@0L
PCB mounting hole and land dimensions (Reference)
(View from switch top)
1.1 (2.2)
2.3
4.4
2.2
2-φ0.7
C0.15
0.68
0.9±0.05
0.4
(0.9)
0.36
0.39
TTP
OP
FP
3
center of rotation
φ0.6±0.05
2±0.1
R0.2
3.1
2.8±0.07
0.8
0.25
0.4
1.65
2±0.05
+0.07
0
1.1 0.4
0.55
1.65
2.8
0.5
A
B
Right operating – with Boss
D3SH-@1R
66 Surface Mount Detection Switch D3SH
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.15 mm applies to all dimensions
2. The operating characteristics are for operation in the A direction () and B direction (, ).
Long Lever Models
Left operating – with Boss
D3SH-@1L
Model D3SH-@@R1
D3SH-@@L1
Operating force (OF) max. 24 gf
Free position (FP) 5.9 ± 0.3 mm
Operating position (OP) 5.4 ± 0.3 mm
Total travel position (TTP) 3.8 ± 0.2 mm
PCB mounting land Dimension (Reference)
(View from switch top)
1.1 (3.1)
3
4.4
2.2
0.36
0.39
0.68
0.9
±0.05
(0.9)
TTP
OP
FP
3
center of rotation
R0.2
0.8
3.1
1.65
0.4
0.25 1.1 0.4
0.55
1.65
0.5
A
B
Right operating – without Boss
D3SH-@0R1
PCB mounting land Dimension (Reference)
(View from switch top)
2.2
4.4
1.1
(3.1)
3
0.68
0.9±0.05
(0.9)
0.36
0.39
3
TTP
OP
FP
center of rotation
0.8
R0.2
0.25
0.4
1.65
3.1
1.1 0.4
0.55
1.65
0.5
A
B
Left operating – without Boss
D3SH-@0L1
Surface Mount Detection Switch D3SH 67
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.15 mm applies to all dimensions
2. The operating characteristics are for operation in the A direction () and B direction (, ).
PCB mounting hole and land dimensions (Reference)
(View from switch top)
1.1 (3.1)
3
4.4
2.2
0.36
0.39
TTP
OP
FP
3
center of rotation
C0.15
0.9±0.05
0.68
0.4
(0.9)
φ0.6±0.05
2±0.1 0.8
2.8±0.07
3.1
R0.2
0.25
0.4
1.65
2±0.05 1.1
2-φ0.7
+
0.05
0
0.4
0.55
1.65
2.8
0.5
A
B
Right operating – with Boss
D3SH-@1R1
PCB mounting hole and land dimensions (Reference)
(View from switch top)
1.1
(3.1)
3
2.2
4.4
0.36
0.39
3
TTP
OP
FP
center of rotation
C0.15
0.9
±0.05
0.68
0.4
(0.9)
φ0.6
±0.05
2
±0.1
0.8
R0.2
0.4
0.25
1.65
2.8
±0.07
3.1
0.5
2
±0.05
1.1
2-φ0.7
+0.05
0
0.4
0.55
1.65
2.8
A
B
Left operating – with Boss
D3SH-@1L1
68 Surface Mount Detection Switch D3SH
Precautions
Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User’s Guide,
“Snap Action Switches, Technical Information” for correct use.
Correct Use
Mounting
The cover has the same electrical potential as the COM terminal. Do not
short-circuit the cover with a NO or NC terminal when mounting the
cover.
Be careful of the following points. Incorrect handling may lead to
insufficient actuator return, Switch damage, or reduced durability.
Set the operating body in line with the direction of the actuator
movement, and make sure that the operating body is completely
separate from the actuator when the Switch is in the free posi-
tion (FP). When the actuator is operated from the crosswise
direction of the Switch, make sure that the corner of the operat-
ing body has a minimum radius of R1.
Set the Switch stroke to 70% to 100% of the overtravel (the differ-
ence between the operating position and the total travel position).
Do not subject the Switch to operations that involve strong impact.
Do not use the Switch as a stopper.
Do not apply excessive loads to the cover or operate the
actuator from a direction other than a specified operating
direction.
Do not use an adhesive to secure the Switch.
A lubricant is used in the Switch. Some of the lubricant may seep out
because the Switch does not have an airtight construction. Consider
this possibility with respect to the usage conditions when designing
or using the Switch.
Application Environment
Do not use the Switch in locations that are subject to toxic gas, sili-
con, excessive dust, excessive dirt, high temperatures, high humidity,
sudden temperature changes, water splashes, or oil splashes.
Otherwise, damage resulting by faulty contact of the Switch contacts,
corrosion, or other causes, or other functional faults may occur.
Insulation and Wiring
Be sure that the installation conditions provide a sufficient insulation
distance between Switch terminals and other metal parts, lands, etc.
Cleaning
The Switch does not have an airtight construction, and it must not be
cleaned with cleaning fluids. Malfunctions may occur if the cleaning
fluid penetrates the interior of the Switch together with flux or foreign
matter from the surface of the PCB.
Confirmation with Actual Equipment
Be sure to confirm the quality of the product under the load and
environmental conditions that will be used during actual applications.
Caution
Electrical Ratings
Confirm the contact load in order to select an appropriate switch rat-
ing.
Do not apply an excessive electrical load to the contacts, otherwise
the contacts may weld, resulting in a short circuit or burning.
Terminal Connection
Do not use flow soldering or hand soldering to solder terminals.
Conduct reflow soldering within the range shown in the terminal tem-
perature profile below. Some reflow soldering devices have
extremely high peak values. Do a test in advance to confirm proper
soldering conditions.
Do not conduct reflow soldering more than twice. Also provide a time
interval of at least five minutes between the first and second reflow
soldering processes to allow the Switch to return to room tempera-
ture. Heating the Switch continuously (without an interval) may cause
the edges of the Switch to melt and degrade the characteristics.
When printing for a screen solder process, a 0.13-mm screen thick-
ness is recommended.
Be sure to provide local ventilation.
Printed Circuit Boards
Special attention must be paid to the handling of printed circuit
boards after a Switch has been mounted onto them. Airborne PCB
particles may penetrate the interior of the Switch when printed circuit
boards are separated by cutting. Also, do not stack printed circuit
boards that have Switches mounted on them.
Product Specification Details
This document provides only a partial list of specifications. It is rec-
ommended that you request complete drawings and specifications
prior to purchasing or using the product.
RoHS Directive Compliance
Models that are indicated as being RoHS compliant are free of the
following six substances.
Lead: 1,000 ppm max.
Mercury: 1,000 ppm max.
Cadmium: 100 ppm max.
Hexavalent chromium: 1,000 ppm max.
PBB: 1,000 ppm max.
PBDE: 1,000 ppm max.
cover
Operating body
R1 min
255ഒ MAX
220
150
Preheating time:
60 to 120 s
Heating time:
40 s max.
Surface Mount Detection Switch D3SH
MEMO
Surface Mount Detection Switch D3SH
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
Cat. No. X303-E-1 Printed in USA
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
11/10 Specifications subject to change without notice
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.