TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 1|4
NI5-M12-Y1X-H1141 | 05/27/2020 11-55 | technical changes reserved
NI5-M12-Y1X-H1141
Inductive Sensor
Technical data
Type NI5-M12-Y1X-H1141
Ident. no. 40103
Rated switching distance 5mm
Mounting conditions Non-flush
Secured operating distance ≤(0.81×Sn)mm
Correction factors St37 = 1; Al = 0.3; stainless steel = 0.7; Ms = 0.4
Repeat accuracy ≤2% of full scale
Temperature drift ≤ ± 10 %
Hysteresis 1…10%
Ambient temperature -25…+70°C
Output function 2-wire, NAMUR
Switching frequency 2kHz
Voltage Nom.8.2VDC
Non-actuated current consumption ≥2.1mA
Actuated current consumption ≤1.2mA
Approval acc. to KEMA 02 ATEX 1090X
Internal capacitance (Ci)/inductance (Li) 150 nF/150 µH
Device marking É II 1 G Ex ia IIC T6 Ga/II 1 D Ex ia IIIC T115 °C
Da
(max. Ui = 20 V, Ii = 20 mA, Pi = 200 mW)
Design Threaded barrel,M12 × 1
Dimensions 52mm
Housing material Metal, CuZn, Chrome-plated
Active area material Plastic, PA12-GF30
Features
M12×1 threaded barrel
Chrome-plated brass
DC 2-wire, nom. 8.2 VDC
Output acc. to DIN EN 60947-5-6 (NAMUR)
M12 x 1 male connector
ATEX category II 1 G, Ex zone 0
ATEX category II 1 D, Ex zone 20
SIL2 (Low Demand Mode) acc. to IEC 61508, PL c
acc. to ISO 13849-1 at HFT0
SIL3 (All Demand Mode) acc. to IEC 61508,
PL e acc. to ISO 13849-1 with redundant
configuration HFT1
Wiring diagram
Functional principle
Inductive sensors detect metal objects contactless
and wear-free. For this, they use a high-frequency
electromagnetic AC field that interacts with the
target. Inductive sensors generate this field via an
RLC circuit with a ferrite coil.
ID Number: 40103
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 2|4
NI5-M12-Y1X-H1141 | 05/27/2020 11-55 | technical changes reserved
Technical data
Max. tightening torque housing nut 10Nm
Electrical connection Connector,M12 × 1
Vibration resistance 55Hz (1 mm)
Shock resistance 30g (11 ms)
Protection class IP67
MTTF 6198years acc. to SN 29500 (Ed. 99) 40 °C
Switching state LED,Yellow
Mounting instructions
Mounting instructions/Description
Distance D 3 x B
Distance W 3 x Sn
Distance T 3 x B
Distance S 1.5 x B
Distance G 6 x Sn
Distance N 2 x Sn
Diameter active area
B
Ø12mm
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 3|4
NI5-M12-Y1X-H1141 | 05/27/2020 11-55 | technical changes reserved
Accessories
IMC-DI-22EX-PNO/24VDC 7560003
2-channel isolating switching amplifier
with M12x1 males, for peripheral use,
IP67, zones 2/22, input circuits II(1)
Ex ia, PNP transistor output NO
IMX12-DI01-2S-2T-0/24VDC 7580020
Isolating switching amplifier, 2-
channel; SIL2 acc. to IEC 61508;
Ex-proof version; 2 transistor
outputs; input Namur signal; ON/OFF
switchable monitoring of wire-break
and short-circuit; toggle between NO/
NC mode; signal doubling; removable
screw terminals; 12.5 mm wide; 24
VDC power supply
QM-12 6945101
Quick-mount bracket with dead-stop;
material: Chrome-plated brass. Male
thread M16 × 1. Note: The switching
distance of the proximity switches
may change when using quick-mount
brackets.
BST-12B 6947212
Mounting clamp for threaded barrel
sensors, with dead-stop; material:
PA6
MW12 6945003
Mounting bracket for threaded barrel
sensors; material: Stainless steel A2
1.4301 (AISI 304)
BSS-12 6901321
Mounting clamp for smooth and
threaded barrel sensors; material:
Polypropylene
Wiring accessories
Dimension drawing Type Ident. no.
RKC4.221T-2/TEB 6628420 Connection cable, female M12, straight,
2-pin, cable length: 2 m, sheath
material: PVC, black; cULus approval;
other cable lengths and qualities
available, see www.turck.com
WKC4.221T-2/TEB 6628427 Connection cable, M12 female
connector, angled, 2-pin, cable length:
2m, jacket material: PVC, black; cULus
approval; other cable lengths and
qualities available, see www.turck.com
TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 4|4
NI5-M12-Y1X-H1141 | 05/27/2020 11-55 | technical changes reserved
Operating Instructions
Intended use
This device fulfills the directive 2014/34/EC and is suited for use in explosion hazardous areas according to EN
60079-0:2012 + A11 and EN 60079-11:2012.Further it is suited for use in safety-related systems, including SIL2 as per IEC
61508.In order to ensure correct operation to the intended purpose it is required to observe the national regulations and
directives.
For use in explosion hazardous areas conform to classification
II 1 G and II 1 D (Group II, Category 1 G, electrical equipment for gaseous atmospheres and category 1 D, electrical equipment for
dust atmospheres).
Marking (see device or technical data sheet)
É II 1 G and Ex ia IIC T6 Ga acc. to EN60079-0 and -26 and É II 1 D Ex ia IIIC T115°C Da acc. to EN60079-0
Local admissible ambient temperature
-25…+70 °C
Installation/Commissioning
These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have
knowledge of protection classes, directives and regulations concerning electrical equipment designed for use in
explosion hazardous areas.Please verify that the classification and the marking on the device comply with the actual
application conditions.
This device is only suited for connection to approved Exi circuits according to EN 60079-0 and EN 60079-11. Please
observe the maximum admissible electrical values.After connection to other circuits the sensor may no longer be
used in Exi installations. When interconnected to (associated) electrical equipment, it is required to perform the "Proof
of intrinsic safety" (EN60079-14).Attention! When used in safety systems, all content of the security manual must be
observed.
Installation and mounting instructions
Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the
device in a dust flow and avoid build-up of dust deposits on the device.If the devices and the cable could be subject to
mechanical damage, they must be protected accordingly. They must also be shielded against strong electro-magnetic
fields.The pin configuration and the electrical specifications can be taken from the device marking or the technical data
sheet.
Service/Maintenance
Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the
manufacturer. The most important data from the approval are listed.