Features Unregulated Converters * * * * * * * * Single output rail Industry standard pinout 1kVDC or 2kVDC/1s basic isolation High efficiency for low power applications UL94V-0 package material Optional continuous short circuit protection Fully encapsulated Efficiency up to 76% Description The RM series DC/DC converter has been designed for isolating or converting DC power rails with very light loads. Efficiencies are typically 10% higher than a comparable 0.5W or 1W converters run at the same low load. DC/DC Converter RM 0.25 Watt SIP4 Single Output Selection Guide Part Number nom. Input Voltage [VDC] Output Voltage [VDC] Output Current [mA] Efficiency typ. (1) [%] max. Capacitive Load (2) [F] RM-xx3.3S (3,4) 3.3, 5, 12, 15, 24 3.3 75 62-70 1000 RM-xx05S (3,4) 3.3, 5, 12, 15, 24 5 50 66-72 470 RM-xx09S (3,4) 3.3, 5, 12, 15, 24 9 28 70-72 470 RM-xx12S (3,4) 3.3, 5, 12, 15, 24 12 21 70-72 150 RM-xx15S (3,4) 3.3, 5, 12, 15, 24 15 17 70-76 150 Notes: Note1: Efficiency is tested at nominal input and full load at +25C ambient Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the capacitive load that will allow start up in under 1s without damage to the converter E358085 Model Numbering RM- __ __S/_ Input Voltage Output Voltage Protection (3) Isolation Option (4) Single Notes: Note3: Note4: UL60950-1 certified CAN/CSA-C22.2 No. 60950-1-03 certified IEC60950-1 certified EN60950-1 certified EN55032 compliant standard part is without continuous short circuit protection add suffix /P" for continuous short circuit protection add suffix /H" for 2kVDC isolation or add suffix /HP" for continuous short circuit protection and 2kVDC isolation Ordering Examples: RM-1205S/P: 12V Input Voltage, 5V Output Voltage, Single Output with continuous short circuit protection RM-0505S/HP: 5V Input Voltage, 5V Output Voltage, Single Output with 2kVDC Isolation and continuous short circuit protection www.recom-power.com REV.: 1/2018 ECO-1 RM DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Input Voltage Range Max. 10% 0% Minimum Load (5) Internal Operating Frequency 50kHz Output Ripple and Noise 90kHz 105kHz 20MHz BW 50mVp-p Notes: Note5: Operation below 10% load will not harm the converter, but specifications may not be met Efficiency vs. Load RM-xx12S 100 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] RM-xx05S 60 50 40 30 50 40 30 20 20 3.305 0505 1205 10 0 60 0 10 20 30 40 50 60 70 80 90 3.312 0512 1212 10 0 100 0 10 20 Output Load [%] 30 40 50 60 70 80 90 100 Output Load [%] RM-xx15S 100 90 Efficiency [%] 80 70 60 50 40 30 20 0515 1215 10 0 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] www.recom-power.com REV.: 1/2018 ECO-2 RM DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm up unless otherwise stated) REGULATIONS Parameter Condition Value Output Accuracy 5.0% max. Line Regulation low line to high line Load Regulation 10% to 100% load Deviation vs. Load 1.2% of 1.0% Vin typ. RM-xx05S RM-xx12S 25 25 3.305 0505 1205 20 15 Deviation [%] Deviation [%] 3.312 0512 1212 20 15 10 5 10 5 0 0 -5 -5 -10 20.0% max. 15.0% max. 10.0% max. 3.3Vout 5Vout 12, 15, 24Vout 0 10 20 30 40 50 60 70 80 90 -10 100 0 10 20 30 Output Load [%] 40 50 60 70 80 90 100 Output Load [%] RM-xx15S 25 0515 1215 20 Deviation [%] 15 10 5 0 -5 -10 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] PROTECTIONS Parameter Type Short Circuit Protection (SCP) Isolation Voltage (6) Value without suffix with suffix "/P" I/P to O/P 1 second continuous without suffix tested for 1 second rated for 1 minute 1kVDC 500VAC/60Hz with suffix "/H" tested for 1 second rated for 1 minute 2kVDC 1.4kVAC/60Hz 10G min. Isolation Resistance Isolation Capacitance 25pF min. / 82pF max. Insulation Grade basic Notes: Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note7: Refer to local wiring regulations if input over-current protection is also required. Recommended fuse: T0.5A slow blow type www.recom-power.com REV.: 1/2018 ECO-3 RM DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm up unless otherwise stated) ENVIRONMENTAL Parameter Condition Operating Temperature Range Value full load @ free air convection (see graph) -40C to +85C Operating Altitude 2000m Operating Humidity non-condensing 95% RH max. Pollution Degree PD2 MTBF according to MIL-HDBK-217F, G.B. Derating Graph 1327 x 103 hours 302 x 103 hours +25C +85C 100 (@ free air convection) 90 Output Load [%] 80 70 60 50 40 30 20 10 0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 85 Ambient Temperature [C] SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Information Technology Equipment, General Requirements for Safety 1602031 Information Technology Equipment, General Requirements for Safety E358085-A4-UL EAC RU-AT.49.09571 RoHs 2+ Standard IEC60950-1:2005, 2nd Edition + A2:2013 EN60950-1:2006 + A2:2013 UL60950-1, 2nd Edition:2007 CAN/CSA C22.2 No. 60950-1-03, 2nd Edition:2007 TP TC 004/2011 RoHS-2011/65/EU + AM-2015/863 EMC Compliance Condition Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement Standard / Criterion with external filter EN55032, Class B EMC Filtering Suggestions according to EN55032 C3 L1 +VIN +VOUT C1 C2 -VIN -VOUT C4 continued on next page www.recom-power.com REV.: 1/2018 ECO-4 RM DC/DC Converter Series Specifications (measured @ Ta= 25C, nom. Vin, full load and after warm up unless otherwise stated) Component List Class A Component List Class B Model C1 C2 3.3, 5Vin 10F 100V, MLCC N/A 12, 15, 24Vin C4 (safety) Model - all types 2.2nF, 5KV, Johanson L1 C1 C3 (safety) C4(safety) 22H choke 10F 1nF 2.2nF RP4532Z-220K MLCC, 100V 5KV, Johanson 5KV, Johanson DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Material case potting PCB non-conductive black plastic (UL94 V-0) epoxy, (UL94 V-0) FR4, (UL94 V-0) Dimension (LxWxH) 11.5 x 6.0 x 10.0mm Weight 1.4g typ. Dimension Drawing (mm) embossed logo 11.5 6.0 0.51+0.10/-0.05 1 2 3 4 Bottom View 2.54 7.62 Recommended Footprint Details 2.54 Pin # 1 2 3 4 Single -Vin +Vin -Vout +Vout Tolerance: xx.x= 0.5mm xx.xx= 0.25mm Top View 1 2 3 4 1.25 1.90 0.250.05 4.10 0.51 10.0 Pinning information Marking PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube 520.0 x 16.0 x 9.0mm Packaging Quantity tube 42pcs Storage Temperature Range -55C to + 125C Storage Humidity 95% RH max. The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM's explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 1/2018 ECO-5