SPECIFICATION CONTROL DRAWING
=
Tyco Electronics Corporation
300 Constitution Drive,
Menlo Park, CA. 94025, U.S.A. Raychem TITLE: SOLDERGRIP RING TERMINAL
Unless otherwise specified dimensions are in millimeters.
[Inches dimensions are shown in brackets] DOCUMENT NO.: SGRT-X-XX
TOLERANCES:
0.00 N/A
0.0 N/A
0 N/A
ANGLES: N/A
ROUGHNESS IN
MICRON
Tyco Electronics reserves the right to amend
this drawing at any time. Users should evaluate
the suitability of the product for their
application.
REV.: A DATE: 13-Nov-06
DRAWN BY:
P.TALLY CAGE CODE:
06090 REPLACES:
D040166 DCR NUMBER:
D060372 SCALE: NTS SIZE: A SHEET:
1 of 1
© 2006 Tyco Electronics Corporation. All rights reserved.
If this document is printed it becomes uncontrolled. Check for the latest revision
Product Dimensions Conductor Cross Section Bundle
Product
Name Marking* øA
øB
Nom øC
Nom L±3.5
(L±0.140)
E
Max. Min. mm2
(CMA) Max.
mm2 (CMA) øD
max Current
Rating
SGRT-2-03 2-3/6 3.8
(0.150) 7.3
(0.285) 37.0
(1.455)
SGRT-2-04 2-4/8 4.3
(0.170) 8.0
(0.315) 37.0
(1.455)
SGRT-2-05 2-5/10 5.5
(0.216) 10.0
(0.394) 39.0
(1.535)
SGRT-2-06 2-6/14 6.5
(0.255) 11.0
(0.435) 40.5
(1.595)
SGRT-2-08 2-8/516
3.9±0.3
(0.155±0.012)
8.4
(0.330) 14.0
(0.550) 45.0
(1.772)
12.8 1.2
(2400) 3.0 (6000) 5.0
(0.195) 15A
SGRT-3-06 3-6/14 6.5
(0.255) 11.0
(0.435) 47.2
(1.860)
SGRT-3-08 3-8/516
5.6±0.5
(0.220±0.020) 8.4
(0.330) 14.0
(0.550) 51.7
(2.035)
14.0 2.5 (5000) 6.6 (132000) 6.5
(0.255) 33A
SGRT-4-06 4-6/14 6.5
(0.255) 11.0
(0.435) 47.4
(1.865)
SGRT-4-08 4-8/516
8.2±0.5
(0.325±0.020) 8.4
(0.330) 14.0
(0.550) 50.9
(2.005)
16.0 6.0
(12000) 11.2 (22400) 9.0
(0.355) 56A
* Marking color: black. See marking code below.
MATERIALS
1. INSULATION SLEEVE: Heat-shrinkable, transparent blue, radiation cross-linked modified polyvinylidene fluoride.
2. SOLDER PREFORM WITH FLUX:
SOLDER: TYPE Sn60 per ANSI/J-STD-006.
FLUX: TYPE ROM1 per ANSI/J-STD-004.
3. OPEN CONICAL COIL: Tin-plated copper alloy.
4. RING TERMINAL: Tin-plated copper alloy.
APPLICATION
1. These controlled soldering devices are designed to terminate tin-plated copper stranded wires having an insulation rated for
85°C minimum, to a ring t e rminal.
2. Temperature range: -55°C to +150°C.
3. Parts conform to the performance requirements of SAE-AS 7928 Specification.
4. See RPIP-820-01 for installation procedure.
For best results, prepare the cable as shown:
Marking Code:
X - X / XXX
Stud Size in inches.
6 = #6
8 = #8
10 = #10
14 = 1/4
516 = 5/16
Stud Size in mm.
Product Size: 2 to 4