Rotary Switches AC09, 16 and 32 Digital code output type Description FUJI AC series rotary switches offer a wide choice of output codes. They feature sliding Au-flashed contacts for high contact reliability. Inhibitor and parity check circuits guard against switch malfunctions caused by error signals. With only seven connections to make, these switches are an economical solution to multiposition switching needs. * The protection of operator section meets the IP65 (IEC), so these switches can be used in oil-splash environments, such as on machine tool control panels. A wide choice of output codes fits a broad range of applications. Available step angles are 15, 30, and 360/26 (13.85). Real binary code, complementary binary code, and real gray code are available. Switches are available with connectors or with lock rings for easy handling. Stopper screw positions are user selectable. * * * Features Au-flashed contacts for high contact reliability. * Ratings Volts 50V AC 5V AC Operational current (A) (resistive load) 0.05 0.5 25V DC 5V DC 0.05 0.25 AC09 AC32 AC16 AF90-209, 210, 211 04 Performance Rated insulation voltage Operating temperature Humidity Service life Mechanical Electrical 60V -20 to +70C 45 to 85%RH (non condensation) 50,000 operations 50,000 operations Dielectric Between terminals strength Between terminals and ground Insulation Between terminals resistance Between terminals and ground Degree of protection (operator section) 250V AC, 1 minute 1500V AC, 1 minute 500M or more 5,000M or more IP65 (IEC) Type number nomenclature AC 09 - C Z 0 / 25 L1 E A01 / 0007 Basic type Mounting 09: M9 nut 16: M16 adapter 32: Adapter (32mm mounting pitch) Type of code R: Real binary code C: Complementary binary code G: Real gray code Angle of step Angle X: 30 W: 360/13 (27.69) Y: 15 Z: 360/26 (13.85) Setting position 0 to 11 0 to 12 0 to 23 0 to 25 Start position Available step angle 0 to 11: 30 0 to 12: 360/13 (27.69) 0 to 23: 15 0 to 25: 360/26 (13.85) End position Available step angle 0 to 11: 30 0 to 12: 360/13 (27.69) 0 to 23: 15 0 to 25: 360/26 (13.85) Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice With or without lock ring Blank: Without lock ring 0007: With lock ring 0009: With adhesive lock ring With or without connector Blank: 8-terminal, without connector A01: 8-terminal, with right-angle connector A02: 8-termianl, with straight connector B00: 7-terminal, without connector B01: 7-terminal, with right-angle connector B02: 7-terminal, with straight connector With or without stopper screw Blank: With stopper screw E: Without stopper screw Length of shaft (mm) AC09 AC16 L1: 16 -- L2: 18 -- L3: 20 -- L4: 22 19.5 Note: AC32 14.5 16.5 18.5 20.5 When shorter action than the maximum range of switch action is used, stopper screws are used. However, stopper screws are not used if the maximum action range is used when either 15 (symbol Y) or 360/26 (symbol Z) is specified. 04/207 Rotary Switches AC09, 16 and 32 * M9 nut mounting Angle of step Connector 30 Without connector 360/13 (27.69) 15 360/26 (13.85) Notes: *1 Replace the Type *1 *2 *3 Lock ring Real binary code Complementary binary code Real gray code Without lock ring With lock ring With adhesive lock ring AC09-RX / ( ) AC09-RX / ( )/0007 AC09-RX / ( )/0009 AC09-CX / ( ) AC09-CX / ( )/0007 AC09-CX / ( )/0009 AC09-GX / ( ) AC09-GX / ( )/0007 AC09-GX / ( )/0009 With right angle connector Without lock ring With lock ring With adhesive lock ring AC09-RX / ( )01 AC09-RX / ( )01/0007 AC09-RX / ( )01/0009 AC09-CX / ( )01 AC09-CX / ( )01/0007 AC09-CX / ( )01/0009 AC09-GX / ( )01 AC09-GX / ( )01/0007 AC09-GX / ( )01/0009 With straight connector Without lock ring With lock ring With adhesive lock ring AC09-RX / ( )02 AC09-RX / ( )02/0007 AC09-RX / ( )02/0009 AC09-CX / ( )02 AC09-CX / ( )02/0007 AC09-CX / ( )02/0009 AC09-GX / ( )02 AC09-GX / ( )02/0007 AC09-GX / ( )02/0009 Without connector Without lock ring With lock ring With adhesive lock ring AC09-RW / ( ) AC09-RW / ( )/0007 AC09-RW / ( )/0009 AC09-CW / ( ) AC09-CW / ( )/0007 AC09-CW / ( )/0009 With right angle connector Without lock ring With lock ring With adhesive lock ring AC09-RW / ( )01 AC09-RW / ( )01/0007 AC09-RW / ( )01/0009 AC09-CW / ( )01 AC09-CW / ( )01/0007 AC09-CW / ( )01/0009 With straight connector Without lock ring With lock ring With adhesive lock ring AC09-RW / ( )02 AC09-RW / ( )02/0007 AC09-RW / ( )02/0009 AC09-CW / ( )02 AC09-CW / ( )02/0007 AC09-CW / ( )02/0009 Without connector Without lock ring With lock ring With adhesive lock ring AC09-RY / ( ) AC09-RY / ( )/0007 AC09-RY / ( )/0009 AC09-CY / ( ) AC09-CY / ( )/0007 AC09-CY / ( )/0009 AC09-GY / ( ) AC09-GY / ( )/0007 AC09-GY / ( )/0009 With right angle connector Without lock ring With lock ring With adhesive lock ring AC09-RY / ( )01 AC09-RY / ( )01/0007 AC09-RY / ( )01/0009 AC09-CY / ( )01 AC09-CY / ( )01/0007 AC09-CY / ( )01/0009 AC09-GY / ( )01 AC09-GY / ( )01/0007 AC09-GY / ( )01/0009 With straight connector Without lock ring With lock ring With adhesive lock ring AC09-RY / ( )02 AC09-RY / ( )02/0007 AC09-RY / ( )02/0009 AC09-CY / ( )02 AC09-CY / ( )02/0007 AC09-CY / ( )02/0009 AC09-GY / ( )02 AC09-GY / ( )02/0007 AC09-GY / ( )02/0009 Without connector Without lock ring With lock ring With adhesive lock ring AC09-RZ / ( ) AC09-RZ / ( )/0007 AC09-RZ / ( )/0009 AC09-CZ / ( ) AC09-CZ / ( )/0007 AC09-CZ / ( )/0009 AC09-GZ / ( ) AC09-GZ / ( )/0007 AC09-GZ / ( )/0009 With right angle connector Without lock ring With lock ring With adhesive lock ring AC09-RZ / ( )01 AC09-RZ / ( )01/0007 AC09-RZ / ( )01/0009 AC09-CZ / ( )01 AC09-CZ / ( )01/0007 AC09-CZ / ( )01/0009 AC09-GZ / ( )01 AC09-GZ / ( )01/0007 AC09-GZ / ( )01/0009 With straight connector Without lock ring With lock ring With adhesive lock ring AC09-RZ / ( )02 AC09-RZ / ( )02/0007 AC09-RZ / ( )02/0009 AC09-CZ / ( )02 AC09-CZ / ( )02/0007 AC09-CZ / ( )02/0009 AC09-GZ / ( )02 AC09-GZ / ( )02/0007 AC09-GZ / ( )02/0009 marks by the Start and End positions Step angle 30 360/13 15 360/26 Start and End positions 0 to 11 0 to 12 0 to 23 0 to 25 *2 Replace the ( ) mark by the shaft length code L1: 16mm L2: 18mm L3: 20mm L4: 22mm 04/208 *3 Replace the mark by the connector Blank: 8-terminal, without connector A01: 8-terminal, with right angle connector A02: 8-terminal, with straight connector B00: 7-terminal, without connector B01: 7-terminal, with right angle connector B02: 7-terminal, with straight connector Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Rotary Switches AC09, 16 and 32 * M16 adapter mounting Angle of step Connector 30 Type*1 *2 Real binary code Complementary binary code Real gray code Without connector With right angle connector With straight connector AC16-RX / L4 AC16-RX / L401 AC16-RX / L402 AC16-CX / L4 AC16-CX / L401 AC16-CX / L402 AC16-GX / L4 AC16-GX / L401 AC16-GX / L402 360/13 (27.69) Without connector With right angle connector With straight connector AC16-RW / L4 AC16-RW / L401 AC16-RW / L402 AC16-CW / L4 AC16-CW / L401 AC16-CW / L402 15 Without connector With right angle connector With straight connector AC16-RY / L4 AC16-RY / L401 AC16-RY / L402 AC16-CY / L4 AC16-CY / L401 AC16-CY / L402 AC16-GY / L4 AC16-GY / L401 AC16-GY / L402 360/26 (13.85) Without connector With right angle connector With straight connector AC16-RZ / L4 AC16-RZ / L401 AC16-RZ / L402 AC16-CZ / L4 AC16-CZ / L401 AC16-CZ / L402 AC16-GZ / L4 AC16-GZ / L401 AC16-GZ / L402 Notes: *1 Replace the marks by the Start and End positions Step angle 30 360/13 15 360/26 Start and End positions 0 to 11 0 to 12 0 to 23 0 to 25 04 *2 Replace the mark by the connector Blank: 8-terminal, without connector A01: 8-terminal, with right angle connector A02: 8-terminal, with straight connector B00: 7-terminal, without connector B01: 7-terminal, with right angle connector B02: 7-terminal, with straight connector * Adaptor mounting (32mm mounting pitch) Angle of step Connector 30 Type*1 *2 *3 Real binary code Complementary binary code Real gray code Without connector With right angle connector With straight connector AC32-RX / ( ) AC32-RX / ( )01 AC32-RX / ( )02 AC32-CX / ( ) AC32-CX / ( )01 AC32-CX / ( )02 AC32-GX / ( ) AC32-GX / ( )01 AC32-GX / ( )02 360/13 (27.69) Without connector With right angle connector With straight connector AC32-RW / ( ) AC32-RW / ( )01 AC32-RW / ( )02 AC32-CW / ( ) AC32-CW / ( )01 AC32-CW / ( )02 15 Without connector With right angle connector With straight connector AC32-RY / ( ) AC32-RY / ( )01 AC32-RY / ( )02 AC32-CY / ( ) AC32-CY / ( )01 AC32-CY / ( )02 AC32-GY / ( ) AC32-GY / ( )01 AC32-GY / ( )02 360/26 (13.85) Without connector With right angle connector With straight connector AC32-RZ / ( ) AC32-RZ / ( )01 AC32-RZ / ( )02 AC32-CZ / ( ) AC32-CZ / ( )01 AC32-CZ / ( )02 AC32-GZ / ( ) AC32-GZ / ( )01 AC32-GZ / ( )02 Notes: *1 Replace the marks by the Start and End positions Step angle 30 360/13 15 360/26 Start and End positions 0 to 11 0 to 12 0 to 23 0 to 25 *2 Replace the ( ) mark by the shaft length L1: 14.5mm L2: 16.5mm L3: 18.5mm *3 Replace the mark by the connector Blank: 8-terminal, without connector A01: 8-terminal, with right angle connector A02: 8-terminal, with straight connector B00: 7-terminal, without connector B01: 7-terminal, with right angle connector B02: 7-terminal, with straight connector L4: 20.5mm Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 04/209 Rotary Switches AC09, 16 and 32 24-position R: Real binary code Terminal No. A F B E C G D Bit No. 1 2 4 8 16 INH C 12-position R: Real binary code Setting position 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Terminal No. A F B E C G D C: Complementary binary code Terminal No. A F B E C G D Bit No. 1 2 4 8 16 INH C C: Complementary binary code Setting position 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Terminal No. A F B E C G D G: Real gray code Terminal No. A F B E C G D Setting position 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Terminal No. A F B E C G D Bit No. 1 2 4 8 16 INH C Bit No. a b c d P Setting position 0 1 2 3 4 5 6 7 8 9 10 11 C 13-position R: Real binary code Setting position 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 C: Complementary binary code Terminal No. A F B E C G D Setting position 0 1 2 3 4 5 6 7 8 9 10 11 26-position R: Real binary code Bit No. 1 2 4 8 16 INH C Bit No. 1 2 4 8 P INH C G: Real gray code Bit No. a b c d e P C Terminal No. A F B E C G D Bit Setting position No. 0 1 2 3 4 5 6 7 8 9 10 11 1 2 4 8 P INH C Bit Setting position No. 0 1 2 3 4 5 6 7 8 9 10 1112 1 2 4 8 P INH C C: Complementary binary code Setting position 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Terminal No. A F B E C G D Terminal No. A F B E C G D Bit No. 1 2 4 8 P INH C Setting position 0 1 2 3 4 5 6 7 8 9 10 1112 G: Real gray code Terminal No. A F B E C G D 04/210 Bit No. a b c d e P C Setting position 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 INH : P: C: : Inhibit terminal Parity check terminal Common terminal Turned ON Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Rotary Switches AC 09, 16 and 32 Accessories Lead wire with connector (8-terminal) Lock ring AF91-675 AF91-710 Length of lead wire (m) Type 0.5 ACX011-805 Mass (g) 11 Lock ring (inserted) ACX001 2 1.0 (Standard) ACX011-810 19 Lock ring (sealed) ACX001A 5 2.0 ACX011-820 33 Type Mass (g) ACX001A o28 6 14 .1 L o9 1 1.2 04 1.9 o16 20.5 4.7 o9.1 o10 ACX001 8 1 1.5 L : 0.5, 1.0, 2.0m Dimensions, mm AC09 AC09 (with connector) Panel thickness Max. 4 40 8-terminal 25.5 8-terminal M9P=0.75 o6 28 22 30.5 23.4 22 20 28 o6 A BCDDE FG Panel thickness Max. 4 8 A BCDDE FG 8 2.54 *L 17.78 *L 25.5 15.8 15.8 M9P=0.75 20 22 Straight connector 30 Right-angle connector 32 2.54 17.78 22 30 31 44 45 In case of using lock ring (AC09- /0007) o2 .7 + -0 0.3 43 44 .1 42 43 o9 41 42 Panel cutting Panel cutting + -0 0.3 Mass (g) Without connector With connector 31 .1 L4 22 o9 L3 20 + -0 0.3 L2 18 .1 * L1 16 o9 Shaft length Panel thickness 1.2 to 3.2 AC32 38 32 28 M9P=0.75 28 20 o6 22 20 15.8 o20 o6 8-terminal 15.8 8-terminal M16P=1 A BCDDE FG 28 Mass: 47g 20 Panel thickness Max. 4 A BCDDE FG 2.54 11 19.5 22 AC16 Panel thickness Max. 4 17.78 M2.3x6 22 6.4 30 27 31 Panel cutting .3 +0 0 .1 - 6 o1 Shaft length * Mass (g) *L L1 L2 L3 L4 14.5 16.5 18.5 20.5 47 48 49 50 2.54 17.78 22 30 31 Panel cutting o320.2 7 o1 M2.3 (for flat head screw) Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 04/211 Rotary Switches AC09, 16 and 32 Installation Switch body O ring Panel Flat washer Toothed look washer M9 hexagonal nut Packing Panel M2.3 flat head screw Panel o16 mounting nut AC09 AC16 AC32 Pass the switch body through the hole from the back of the panel, and secure it by tightening the hexagonal nut with a flat washer and a toothed lock washer. The recommended tightening torque for the hexagonal nut is 1.5 to 2N*m. Insert the lock ring (ACX001) between the panel and the flat washer, and the adhesive lock ring (ACX001A) between the switch body and the panel. Pass the switch body with a bezel through the hole from the back of the panel, and secure it with a 16 mounting nut. The recommended tightening torque for the nut is 0.6 to 1N*m. Pass the switch body through the hole from the back of the panel, and secure it with two flat head screws from the face of the panel. The recommended tightening torque for the flat head screws is 0.3 to 0.5N*m. 4. Stopper screw positions Insert stopper screws into the switch body holes marked with letters, as shown in the insertion example on the right. These tables below show that the start position stopper screw is inserted in the hole on the left of the position setting and the end positions stopper screw is inserted in the hole on the right. Stopper screw holes (24) G H E F I J A B Y Z C X A B WX C V U P S T Q R 04/212 W 3. Number of stopper screws shipped AC09 and AC32 * Step angle: 30 (symbol X) Positions 0/11 (0 to 11): one screw. User-selectable start and stop positions: two screws (one for start position, one for end position). * Step angle: 15 (symbol Y) Positions 0/22 (0 to 22): one screw. User-selectable start and stop positions: two screws (one for start position, one for end position). * Step angle: 360/26 (symbol Z) Positions 0/24 (0 to 24): one screw. User-selectable start and stop positions: two screws (one for start position, one for end position). AC16 Customers can specify the stopper screw positions. The switch is then shipped with stopper screws already in the specified positions. If step angle X (30) or Y (15) is specified. F G H I L MN OP M N K L O Switch body E K J Do not disconnect this case linkage. D S T U V D Stopper screw holes (26) R 2. Note on the case linkage Q Notes on use 1. Connecting wires Note the following points when soldering: * The power of the soldering iron must not be over 30W. * Use solder with resin flux core. * Complete soldering within 5 seconds if using a 30W soldering iron, or within 10 seconds if using a 20W soldering iron. If step angle W (360/13) or Z (360/26) is specified. 5. Installing a stopper screw The maximum tightening torque for a stopper screw is 0.1N*m. Screw the stopper screw into position until it hits the body frame rib. Do not overtighten the screw. Stopper screw Frame rib Stopper screw Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice Rotary Switches AC 09, 16 and 32 Insertion example 1 AC09-C 0/7L1 Step angle With a stopper screw X: 30, W: 360/13, Y: 15, Z: 360/26 Start position setting: 0 Blank: With stopper screw E: No stopper screw End position setting: 7 * If symbol (step angle) is X-----type AC09-CX0/7L1: Insert the start side stopper screw in hole A and the end side screw in hole Q. Start position setting End position setting Range of switch action Setting 0 1 2 3 4 5 6 7 8 9 10 11 Stopper screw E G I S U W A A C K M O Q position Start side stopper screw position End side stopper screw position 04 * If symbol (step angle) is W-----type AC09-CW0/7L1: Insert the start side stopper screw in hole A and the end side screw in hole Q. Start position setting End position setting Range of switch action Setting 0 1 2 3 4 5 6 7 8 9 10 11 12 Stopper screw E G I S U W Y A A C K M O Q position Start side stopper screw position End side stopper screw position * If symbol (step angle) is Y-----type AC09-CY0/7L1: Insert the start side stopper screw in hole A and the end side screw in hole J. Start position setting End position setting Range of switch action Setting 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Stopper screw Start side A B C D E F G H I J K L M N O P Q R S T U V W X End side position C D E F G H I J K L M N O P Q R S T U V W X A B End side stopper screw position Start side stopper screw position Notes: 1. If the range of action is designated as 0/22 (0 to 22), insert a stopper screw into hole A only. 2. If the range of action is designated as 0/23 (0 to 23), no stopper screws are inserted (symbol is E). * If symbol (step angle) is Z-----type AC09-CZ0/7L1: Insert the start side stopper screw in hole A and the end side screw in hole J. Start position setting End position setting Range of switch action Setting 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Stopper screw Start side A B C D E F G H I J K L M N O P Q R S T U V W X Y Z End side position C D E F G H I J K L M N O P Q R S T U V W X Y Z A B Start side stopper screw position End side stopper screw position Notes: 1. If the range of action is designated as 0/24 (0 to 24), insert a stopper screw in hole A only. 2. If the range of action is designated as 0/25 (0 to 25), no stopper screws are inserted (symbol is E). Insertion example 2 AC09-RX2/11 Step angle Start position setting End position setting Start position setting End position setting Range of switch action Setting 0 1 2 3 4 5 6 7 8 9 10 11 Stopper screw position A C E G I S U W A K M O Q Start side stopper screw position End side stopper screw position Fuji Electric FA Components & Systems Co., Ltd./D & C Catalog Information subject to change without notice 04/213