Global Home Our Strengths Products Search Contact Technical Support Global Network About Us Home > Products > Product Category > Control Components > Timers > Analog Timers > H3DK-M / -S > Item list > H3DK-S1 AC/DC24-240 English Multi-range, Multi-mode Timer Series H3DK-S1 AC/DC24-240 Print Page Analog Timer, DC24 to 240V, AC24 to 240V 24 to 240VAC 50/60 Hz 24 to 240VDC ripple: 20% max. Relay output (SPDT) Rated supply voltage Control output Type Item list of H3DK-M / -S Multi-range, Multi-mode Timer H3DK-M / -S Catalog about this Product Inquiry of this Product Image Ratings/Performance Dimensions Block diagram Terminal arrangement Time ranges Operating chart As of November 11, 2015 Rated supply voltage Operating voltage range Minimum input signal width Power consumption ( Relay ON ) Power consumption ( Relay OFF ) Reset voltage Number of time ranges Time ranges Operating mode Control output Type Control output Contact output Ambient temperature Ambient humidity Accuracy of operating time Setting error Influence of voltage Influence of temperature Insulation resistance Dielectric strength Impulse withstand voltage Noise immunity Static immunity Vibration resistance (Destruction) Vibration resistance (Malfunction Shock resistance (Destruction Shock resistance (Malfunction Mechanical life expectancy (relayoutput) Electrical life expectancy (relay output) Degree of protection Weight (Main) 24 to 240VAC 50/60 Hz 24 to 240VDC ripple: 20% max. 85% to 110% of rated supply voltage 50 ms min. (Start input) 4.5VA(at 240 VAC) 1.1W(at 24 VDC) (at 240 VAC) (at 24 VDC) 10% max. of rated supply voltage 8 0.1s1.2s / 1s12s / 10s120s / 1min12min / 10min120min / 1h12h / 10h 120h / 100h1200h ON delay, Flicker ON start, Interval, One shot output Relay output (SPDT) Switching capacities (resistive load (cos (phi) = 1)): 250VAC 5A / 30VDC 5A Switching capacities (resistive load (cos (phi) = 1)): 250VAC 5A / 125VDC 0.15A Switching capacities (resistive load (cos (phi) = 1)): 250VAC 5A / 125VDC 0.1A Minimum applicable load: 10 mA at 5 VDC (failure level: P) Operating: -20 to 55 Storage: -40 to 70 : 2585% +/- 1% max.(FS) +/- 1% +/- 10 ms max. in a range of 1.2 s -10 to 10% +/- 0.05 s max. (FS) +/- 0.5% FS max. (+/- 0.5% +/- 10 ms max. in a range of 1.2 s) +/- 2% FS max. (+/- 2% +/- 10 ms max. in a range of 1.2 s) 100 M (at 500 VDC) between current carrying metal parts and non-current carrying metal parts: 2000 VAC, 50/60 Hz for 1 min between control output terminals and operating circuit: 2000 VAC, 50/60 Hz for 1 min between non-continuous contacts: 1000 VAC, 50/60 Hz for 1 min between power terminals: 5 kV between exposed non-current-carrying metal parts: 5 kV +/- 1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 us, 1-ns rise) Mulfunction: 4 kV Destruction: 8 kV 10 to 55 Hz, 0.75 mm single amplitude each in X, Y, and Z directions for 2 hours 10 to 55 Hz, 0.5 mm single amplitude each in X, Y, and Z directions for 10 min 1000 m/s**2, 3 times each 6 directions 100 m/s**2, 3 times each 6 directions 10000000 operations min. (under no load at 1800 operations/h) 100000 operations min. (5 A at 250 VAC, resistive load at 360 operations/h) IP30(Terminal Block: IP20) Approx. 120 g As of November 11, 2015 Top of page OMRON Corporation Sitemap Terms of Use Privacy Policy (c) Copyright OMRON Corporation 2007 - 2012. All Rights Reserved.