https://www.phoenixcontact.com/us/produkte/2835435 Signal isolator - PI-EX-ME-RPS-I/I - 2835435 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://download.phoenixcontact.com) Repeater power supply, (Analog IN), input: intrinsically safe, input signal: 0(4) ... 20 mA, output signal: 0(4) ... 20 mA The illustration shows version PI/ EX-ME-RPSS-I/I Key commercial data Packing unit 1 Minimum order quantity 1 Catalog page Page 401 (IF-2007) GTIN Custom tariff number 85043180 Country of origin GERMANY Technical data Input data Signal input Current input, intrinsically safe Available input sources 2-wire measuring transducers, 4...20 mA Current input signal 4 mA ... 20 mA Transmitter supply voltage 17 V (at 20 mA) Connection method 2, 3-wire Output data Signal output Current output Current output signal 0 mA ... 20 mA Current output signal 4 mA ... 20 mA Load/output load current output 1000 Power supply Supply voltage range 20 V DC ... 30 V DC Max. current consumption < 90 mA (at 24 V DC/20 mA) Power consumption 2.2 W 05.12.2012 Page 1 / 4 https://www.phoenixcontact.com/us/produkte/2835435 Signal isolator - PI-EX-ME-RPS-I/I - 2835435 Technical data Connection data Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 2.5 mm Conductor cross section stranded min. 0.2 mm Conductor cross section stranded max. 2.5 mm Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 14 Stripping length 8 mm Screw thread M3 Connection method Pluggable screw connection Tightening torque, min 0.5 Nm Tightening torque max 0.6 Nm General data No. of channels 1 Maximum transmission error 0.1 % (of final value) Maximum temperature coefficient < 0.01 %/K Ambient temperature (operation) -20 C ... 60 C Ambient temperature (storage/transport) -25 C ... 80 C Permissible relative humidity (operation) < 75 % (annual average) Permissible relative humidity (operation) < 95 % (30 days/year, no condensation) Step response (10-90%) 2.2 ms Status display Green LED (supply voltage) Width 22.5 mm Height 99 mm Depth 114.5 mm Inflammability class according to UL 94 V0 Standards/regulations NAMUR recommendation NE 21 Housing material Polyamide PA non-reinforced Color green Electrical isolation input / output / supply 375 V (Peak value, in acc. with EN 50020) Line monitoring NE 21 Conformance CE-compliant ATEX II (1)GD, [EEx ia] IIC, TUV 00 ATEX 1522 UL, USA / Canada cULus Classifications ETIM ETIM 2.0 EC001431 ETIM 3.0 EC001596 ETIM 4.0 EC001596 ETIM 5.0 EC001596 05.12.2012 Page 2 / 4 https://www.phoenixcontact.com/us/produkte/2835435 Signal isolator - PI-EX-ME-RPS-I/I - 2835435 Classifications UNSPSC UNSPSC 11 39121008 UNSPSC 13.2 39121008 UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 eCl@ss eCl@ss 4.0 27210121 eCl@ss 4.1 27210121 eCl@ss 5.0 27210121 eCl@ss 5.1 27210121 eCl@ss 6.0 27210121 Accessories Accessories Bridges Wire bridge - DB 50- 90 GY - 2820929 Wire bridge, Color: gray Wire bridge - DB 50- 90 BK - 2820916 Wire bridge, Color: black Wire bridge - DB 50- 90 BU - 2821180 Wire bridge, Color: blue Drawings 05.12.2012 Page 3 / 4 https://www.phoenixcontact.com/us/produkte/2835435 Signal isolator - PI-EX-ME-RPS-I/I - 2835435 Dimensioned drawing Block diagram Block diagram: PI-EX-ME-RPS-I/I (c) Phoenix Contact 2012 - all rights reserved http://www.phoenixcontact.com 05.12.2012 Page 4 / 4