Manual Switches Mounting Dimensions (For Reference Only) AML11/12 and 21/22 SWITCHES AML41C/D and AML42C INDICATORS Note: Top of full guard bezel housing .19/5,0 from panel. PUSHBUTTONS For terminal locations, see page 61. AML Series AML27 SWITCHES KEYLOCK For terminal locations, see page 62. AML13/15 and 23/25 SWITCHES ROCKERS PADDLES For terminal locations, see page 61, 62. For terminal locations, see page 61, 62. Manuals AML14/16 and AML24/26 SWITCHES AML41 INDICATOR AML42 INDICATOR LENS STYLE MINIATURE TERMINAL TYPES For terminal locations, see page 62. NOTE 1 Dimensions are mm or mm/IN IN Solder Hole will accept two #22 AWG Stranded Conductor (per NEMA publication DC-2 1976) Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada 59 Manual Switches Mounting Dimensions (For Reference Only) AML Series AML31/32 SWITCHES AML34/36 SWITCHES PUSHBUTTON ROCKER AML33/35 SWITCHES TERMINAL LOCATIONS PADDLE PUSHBUTTON ROCKER AND PADDLE PANEL CUTOUT FOR SINGLE-STATION FRONT-OF-PANEL MOUNTING Recommended panel thickness: .060-.187/1,52-4,75 NOTES 1 Dimensions are mm or mm/IN IN Manufacturers logo on this side of housing Solder Hole Will Accept One #14 AWG Stranded Conductor (Per NEMA Publication DC-2 1976) 60 PANEL PUNCH FOR AML SERIES A panel punch is manufactured by Greenlee-Textron Tool Co., Rockford, IL (815-926-3011). Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Manual Switches Mounting Dimensions (For Reference Only) AML Series TERMINAL LOCATIONS FOR AML10 SWITCHES PUSHBUTTONS Solder and Quick-Connect Printed Circuit Illuminated devices shown (non-illuminated devices do not have lamp terminals). ROCKERS AND PADDLES Solder and Quick-Connect Printed Circuit One Integrated Circuit Two Integrated Circuits One Integrated Circuit Two Integrated Circuits Illuminated devices shown (non-illuminated devices do not have lamp terminals) TERMINAL LOCATIONS FOR AML41 INDICATORS Solder and Quick-Connect Manuals 1 Incandescent Lamp Circuit 1 Incandescent Lamp Circuit 2 Incandescent Lamp Circuits 2 Incandescent Lamp Circuits 1-3 Incandescent Lamp Circuits Printed Circuit 1 Incandescent Lamp Circuit 1 Incandescent Lamp Circuit 2 Incandescent Lamp circuits 2 Incandescent Lamp Circuits 1-3 Incandescent Lamp Circuits TERMINAL LOCATIONS FOR AML42 INDICATORS Solder and Quick-Connect 1 LED Circuit Printed Circuit 1 LED Circuit 1 LED Circuit 1 LED Circuit NOTE 1 Dimensions are MM or MM/IN IN Manufacturer's logo on this side of housing 4 - Lamp terminals are not provided for non-illuminated devices positive terminal ident. (+) marked this side of housing 1 - lamp termination identified by ``B''. 2 - lamp termination identified by ``A'' and ``C''. Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada 61 Manual Switches Mounting Dimensions (For Reference Only) AML Series TERMINAL LOCATIONS FOR AML20 SWITCHES PUSHBUTTON SWITCHES Solder or Quick-Connect Terminal identification marked on each adjacent side of housing KEYLOCK SWITCHES Solder or Quick-Connect Printed Circuit 1 Pole 2 Pole 4 Pole PUSHBUTTON SWITCHES Printed Circuit 1 Pole 2 Pole ILLUMINATED ROCKERS AND PADDLES Solder or Quick-Connect 1 Pole Printed Circuit 2 Pole 1 Pole NON-ILLUMINATED ROCKERS AND PADDLES Solder or Quick-Connect 1 Pole 62 4 Pole 2 Pole 1 Pole 2 Pole 2 Pole Printed Circuit 4 Pole Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Manual Switches Mounting Dimensions (For Reference Only) AML Series ANNUNCIATORS AML45 SERIES Manuals Manufacturer's logo on this side of housing For panel punch manufacturer, see page 60. Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada 63 Manual Switches Mounting Dimensions (For Reference Only) AML Series MULTI-STATION FRONT-PANEL MOUNTING Panel cutouts (See page 61 for panel punch manufacturer.) Square Switches & Indicators Rect. Switches & Indicators Annunciator (.8) (No. of units) -- .045* (20,3) (No. of units) -- 1,14* (1.20) (No. of units) -- .045 * (30,5) (No. of units) -- 1,14 * (.40) (No. of units) -- .045 * (10,1) (No. of units) -- 1,14 * For each barrier, add .053/1,35 * Note: If barriers are used, do not subtract .045 in./1,14 mm from the panel cutout formula. (.045 in./1,14mm is the allowance for the width of the bezel.) AML61 MULTI-STATION SUBPANEL MOUNTING Panel cutouts for AML61 Mounting Bracket Orientation Width Length A* in. mm .810 20,57 (.810)(No. of units) B in. mm .810 20,57 (1.210)(No. of units) C or D* in. 1.210 mm 27,94 (.810)(No. of units) * More than two cans with mounting brackets required for strips of more than 10 units. AML61 MOUNTING CENTERS Mounting Bracket Orientation Mounting Centers/Number of Cans 1 2 3 4 5 6 7 8 9 10 11 12 7.765 197,23 8.575 217,81 9.385 238,38 10.195 258,95 6.456 163,98 7.263 184,48 8.070 204,98 8.877 225,48 ``A'' or ``C'' in. mm 1.285 32,64 2.095 53,21 2.905 73,79 3.715 94,36 4.525 114,94 5.335 135,51 6.145 156,08 6.955 176,66 ``B'' in. mm 1.685 42,80 2.895 73,53 4.105 104,27 5.315 135,00 6.525 165,74 7.735 196,48 8.945 227,20 10.155 257,94 ``D'' or ``E'' in. mm on CL on CL .807 20,50 1.614 41,00 2.421 61,49 3.228 81,99 4.035 102,49 4.842 122,99 5.649 143,48 Tolerance J .015 D B C A E 64 Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada Manual Switches Mounting Dimensions (For Reference Only) AML Series AML75 PANEL SEAL ACCESSORY Panel cutouts Multiple panel sealed units should not be mounted together in a single elongated slot, since this would create an unsealed space between each unit. Side-by-side mounting can be achieved, per the center-to-center dimensions shown in the drawing. (Dotted lines indicate the seal bases which are abutting at front of panel.) AML75 seals are not designed for use with the AML61 mounting system. NOTE: Suggested cutout dimensions are based on an .125N/3,18 mm panel thickness. Individual preferences for inpanel fit may require measurement of assemblies before panels are cut. AML76 SWITCH GUARD ACCESSORY Manuals PANEL CUTOUTS Honeywell 1 Sensing and Control 1 1-800-537-6945 USA 1 F1-815-235-6847 International 1 1-800-737-3360 Canada 65