First Edition Sep 5, 2005 LCD Module Technical Specification Final Revision RRRREE TypeXo. DMF -50840NB-FW-ASE-BFN Th, Abd Approved by (Quality Assurance Division) ar Checked by (ACI Engineering Division) T. Yuchi Prepared by (ACI Engineering Division) Table of Contents 1. General Specification 00... ccc cecsssessseesecsseeseesseessessnsssessnsssessesssecsussutsssessesseesereeseentseessesavessveraeasessses 2 2. Electrical Specifications o.oo ccccccsessessesseesessesssesessusssessssssssssasssesssesseuecessresecsecsreeevessaneususstanensuaseeasenas 3 3. Optical Specifications oo ecececcsecsesssessesssessessnessesssessescansansssesssecasessecesecsvensesseesseessesseesissseesesssesseeesecess 8 A. VO Terminal... ec ecccccecseseeseesesessesscensseesesscsesnssssncesessncnsatsarsacassssaseasesesssasesecsasesssesanseucsesessesaseseseesesessneersenss 10 D. TOSt i. eseceessessnecsesssessssssesssessnssnsssnsssucanecsuecsneausssssessssssessssssessseenseassesscesecssessenssesseesvenssessssusssutsussecssseeseeseveses 12 G. Appearance Standards cc eccececcscssesecseesssseesesensevesscssecsesssessesssasesseseansareaseessansasecseessasseusecesseesesseesesees 13 7. Code System of Production Lot... eccccccesssessssssssessssssssesssesssessssccssesesessssessusssecssesseacsaseessnesesecsaveseans 16 B. Type NUMBER... eee eecsesssscssssesnsessveastecsnsesssscasssessecssscssssessseassscsseseunsesavensesssesssustsseessseesunsessesseversevenness 16 9. Applying Precautions ..........ccccccecscssssssessssessssssssccssssssecsssecsusssnsesssrcssesssasescesssuessassssusssvesavsasevessecesussasecsuecstees 16 10. Precautions Relating Product Handling...0.......c..cccccsesssesssessssssesssssssseessecsssesssessssesssesssesssiesseeesseeess 17 11. Warranty Revision History Rev. Date Page Comment DMF-50840NB-FW-ASE-BFN (BF) No. 2005-0302 OPTREX CORPORATION Page 1/181.General Specifications Operating Temp. Storage Temp. Dot Pixels Dot Size Dot Pitch Viewing Area Outline Dimensions Weight LCD Type Viewing Angle Data Transfer Backlight Additional Spec. Drawings RoHS regulation min. 0C ~max. 60C min. -20C ~max. 60C 320 (W) X 240 (H) dots 0.33 (W) X 0.33 (H) mm 0.36 (W) X 0.36 (H) mm 120.0 (W) X 90.0 (H} mm 167.1 (W) X 109.0* (H) X 11.0max.* (D) mm Without Connector **Without CFL Cable 230g max. NTD-15885 ( STN / Blue-mode / Transmissive ) 6:00 4-bit parallel data transfer Cold Cathode Fluorescent Lamp (CFL) < 1 Electroplated Coating of Black-Zinc on Steel Holder Type Dimensional Outline UE-36988A To our best knowledge, this product satisfies material requirement of RoHS regulation. Our company is doing the best efforts to obtain the equivalent certificate from our suppliers. DMF-50840NB-FW-ASE-BEFN (BF) No. 2005-0302 OPTREX CORPORATION Page 2/182.Electrical cifications 2.1.Absolute Maximum Ratings Vss=0V Parameter Symbol Conditions Min. Max. Units Supply Voltage Vcc-Vss - -0.3 7.0 V (Logic) Supply Voltage Vcc-VEE - 0 35.0 Vv (LCD Drive) Input Voltage Vi - -0.3 Vcc+0.3 Vv 2.2.DC Characteristics Ta=25C, Vss=0V Parameter Symbol Conditions Min. Typ. Max. Units Supply Voltage Vcc-Vss - 4.5 - 5.5 Vv (Logic) Vec-Vee - 26.4 - 30.0 Vv Supply Voltage (LCD Drive) Vec-VabJ Shown in 3.1 V High Level VIH Vcc=5.0V+10% 0.8x Vcc - Vec V Input Voltage Low Level Vit Vcc=5.0V+10% 0 - 0.2xVcc Vv Input Voltage lec Vcc-Vss=5.0V - 5.5 15.0 mA Supply Current lee Vec-VabdJ=23.3V - 5.0 10.0 mA DMF-50840NB-FW-ASE-BFN (BF) No. 2005-0302 OPTREX CORPORATION Page 3/182.3.AC Characteristics Vec=5.0V+10% Parameter Symbol Min. Max. Units CP Frequency fcr - 6.0 MHz Clock Pulse Width twe 50 - ns Latch Pulse Width twe 63 - ns Data Setup Time tsetup 30 - ns Data Hold Time toto 30 - ns Clock Pulse Setup Time ter 80 - ns Clock Pulse Hold Time tic 0 - ns Rise/Fall Time tr, tf - Note 1 ns FLM Setup Time tros 100 - ns FLM Hold Time teow 100 - ns Note 1:The rise and fall times (tr, tf ) must satisfy the following relationships. tr, tf < 1 - twe 2fcp tr, ff < 50 ns LP cP tr two | I* tcl tf ; A twe SETUP. DO~D3 x FLM DS FDH This module contains these capacitors. Please be careful about timing characteristics. FLM I TT 4000pF LP [ ~T 470pF " 2 1000pF VSS DMF-50840NB-FW-ASE-BFN (BF) No. 2005-0302 OPTREX CORPORATION Page 4/182.4. Timing Chart > REREREXE toe KEE NENE) (Reduction) T (Reduction) : : 2.5.Comparison of Display and Data GEG1 -seestesssecsseese ceser se sues sees arene sees tres tetsavesaretis SEG320 #1 D3 | D2 } D1 | DO | crrrrrcrecececetnnnn nnn noee nee creencee D1 | DO TOP VIEW DO~D3 DMF-50840NB-FW-ASE-BFN (BF) No. 2005-0302 OPTREX CORPORATION Page 5/182.6.Power Supply ON/OFF Sequence 2.6.1.O0N Sequence SIGNAL _ LEVEL Vcc VOC oof port t ct re sence sees vss < ot VCC SIGNAL : VSS : Os t wecalene we eweceeeeeees vec VAD se vss VEE : : VADJ VEE << t m fo VCC DISPOFF : fcr mtecssseee vss 2.6.2.0FF Sequence LEVEL SIGNAL VCC } VES Potro t trotters cessed ---+ vec : < vec e2Et vss : SIGNAL : os t vec > ee wee ees mee VSS fort c ttt rts -f- vee. VADJ TY VEE : : st vcc : a VSS Frrcrctstees DISPOFF Please maintain the above sequence when turning on and off the power supply of the module. If DISPOFF is supplied to the module while internal alternate signal for LCD driving (M) is unstable, DC component will be supplied to the LCD panel. This may cause damage the LCD module. DMF-50840NB-FW-ASE-BFN (BF) No. 2005-0302 OPTREX CORPORATION Page 6/182.7.Lighting Specifications Ta=25C Parameter Symbol | Conditions Min. Typ. Max. Units |Notes Lamp Voltage Vt - - 340 - Vrms 1 Lamp Current IL - 3.0 4.0 5.0 mArms | 2 Starting Voltage Vs - 850 - - Vrms 3 Surface Luminance L L=4.0mA - 60 - cd/m? 4 Average Life TAL L=4.0mMA 20000 - - hrs 5 Brightne Ratio B IL=4.0mMA 70 - - % Note 1 :The voltage ( r.m.s. ) to maintain the electric discharge of the lamp. It is measured after lighting for 3 minutes . Note 2 :The current ( r.m.s. } to flow through the lamp with the electric discharge. It is measured after lighting for 3 minutes. Note 3 :The voltage at starting the electric discharge when the voltage is increased gradually from OV. Note 4 :Surface Luminance is specified by the average of 9 luminance values measured at each point shown above after 20 minutes power on with the all ON pattern adjusted to maximum contrast and the dimming control of 100%. ( maximum brightness ) Note 5 : CFL Life is defined as time period that the actual luminance becomes 50% or lower of its initial value. The Average life time of CFL is defined as the time when half or more of the testing CFLs have become less bright than 50% of the initial brightness at continuous operation. oO Y=60 Y=160 Y=260 \ c . PLO veeee! PRG. P36 vee wh. yap N r . Phe re Pag... Pg te x2420 A PTO are PR Gein PB Qe teohe yo199 CFL Testina Circuit Measurement Points Recommended Inverter : S-12561 ( Produced by ELEVAM ) CXA-L10L (DC 12.0V, Produced by TDK) DMF-50840NB-FW-ASE-BFN (BF) No. 2005-0302 OPTREX CORPORATION Page 7/183.Optical Specifications 3.1.LCD Driving Voltage Parameter Symbol Conditions Min. Typ. Max. Units Recommended Ta= C - - 26.4 Vv LCD Driving Voltage Vec-VapJ Ta=25C 21.7 23.3 24.9 Vv Note 1 Ta=60C 20.0 - - V Note 1 : Voltage (Applied actual waveform to LCD Module) for the best contrast. The range of minimum and maximum shows tolerance of the operating voltage. The specified contrast ratio and response time are not guaranteed over the entire range. 3.2.Optical Characteristics Ta=25C, 1/240 Duty, 1/14 Bias, Vop=22.7V (Note 4), 0= 0C, d=- Parameter Symbol Conditions Min. Typ. Max. Units Contrast Ratio Note 1 CR 8= 0C , g- - 5 - Viewing Angle Shown in 3.3 Response | Rise Note 2 Ton - - 250 380 ms Time | Decay Note 3 Torr - - 280 420 ms Note 1 :Contrast ratio is definded as follows. (CR = Lon / Lorr) Lon : Luminance of the ON segments Lorr: Luminance of the OFF segments Note 2 :The time that the luminance level reaches 90% of the saturation level from 0% when ON signal is applied. Note 3 :The time that the luminance level reaches 10% of the saturation level from 100% when OFF signal is applied. Note 4 :Definition of Driving Voltage Voo Vop=Vcc-VabJ-VBE Assuming that the typical driving waveforms shown below are applied to the LCD Panel at 1/A Duty - 1/B Bias (A: Duty Number, B: Bias Number). Driving voltage Von is definded as the voltage Vo-p when the contrast ratio (CR=Lon / Lorr) is at its maximum. Vo-p opr betes : 7 I; ( B-2 ) xVo-p/B Sd (fexA ) 1 fe ; (ON SIGNAL )} ( OFF SIGNAL ) DMF-50840NB-FW-ASE-BFN (BF) No. 2005-0302 OPTREX CORPORATION Page 8/183.3. Definition of Viewing Angle and Optimum Viewing Area *Point e shows the point where contrast ratio is measured. : 0= 0, - Driving condition : 1/240 Duty, 1/14 Bias, Voo=22.7V, fF=75Hz 90 180 180 270 270 *Area 2 shows typ. CR>2 3.4.System Block Diagram Temperature Chamber Rotation Table ( 8, ) Photometer #1980A WB <) LCD ] Optical Fiber 7) Computer Control Unit & cc Waveform Generator O Halogen bulb DMF-50840NB-FW-ASE-BEN (BF) No. 2005-0302 OPTREX CORPORATION Page 9/184.1/O Terminal 4.1.Pin Assignment CN1 No. Symbol Level Function 1 DO H/L Display Data 2 D1 H/L Display Data 3 D2 H/L Display Data 4 D3 H/L Display Data 5 DISPOFF H/L H : Display on L : Display off (Pull up Resister) 6 FLM H/L First Line Marker 7 NC - Non-connection 8 LP HL Data Latch Signal 9 CP HL Clock Signal for Shifting Data 10 Vec - Power Supply for Logic 11 Vss - Power Supply (OV, GND) 12 VEE - Power Supply for LCD Drive 13 Vaby - Voltage Level for LCD Contrast Adjustment 14 FG - Frame Ground CN2 No. Symbol Level Function 1 CFL HOT - Power Supply for CFL (HOT) 2 NC - Non-connection 3 NC - Non-connection 4 CFL GND - Power Supply for CFL (GND) 4.2.Example of Power Supply It is recommended to apply a potentiometer for the contrast adjust due to the tolerance of the driving voltage and its ternperature dependence. MODULE vec - VCC (+Voltage) R1 VADJ [> =vrR R2 VEE VEE (-Voltage) vss [7 vss (ov) R1+R2+VR=10~ 20KQ DMF-50840NB-FW-ASE-BFN (BF) No. 2005-0302 OPTREX CORPORATION Page 10/184.3.Block Diagram Row Driver 240 LCDP FLM > LC79430D = 3 7 or equivalent 320 x 240 dots 2 4 t A LP Sf J 320 DISPOFF . > 2 > Column Driver LC79401D x 4 cp or equivalent 4 A 4 DO~D3 A LP M Circuit VCC VSS | Bias Circuit - ToLS| VADJ VEE CFL HOT -_ CFL Backlight CFL GND DMF-50840NB-FW-ASE-BFN (BF) No. 2005-0302 OPTREX CORPORATION Page 11/185.Test No change on display and in operation under the following test condition. Conditions: | Unless otherwise specified, tests will be conducted under the following condition. Temperature: 20+5C Humidity : 65+5%RH tests will be not conducted under functioning state. No. Parameter Conditions Notes 1 High Temperature Operating 60C+2C, 96hrs (operation state) 2 Low Temperature Operating 0C+2C, 96hrs (operation state) 1 3 High Temperature Storage 60C+2C, 96hrs 2 4 Low Temperature Storage -20C+2C, 96hrs 1,2 5 Damp Proof Test 40C+2C,90~95%RH, 96hrs 1,2 6 Vibration Test Total fixed amplitude : 1.5mm 3 Vibration Frequency : 10~55Hz One cycle 60 seconds to 3 directions of X, Y, Z for each 15 minutes 7 Shock Test To be measured after dropping from 60cm high on the concrete surface in packing state. Dropping method corner dropping A comer : once Edge dropping B,C,0 edge : once Face dropping E,F,G face : once Note 1 :No dew condensation to be observed. Note 2 :The function test shall be conducted after 4 hours storage at the normal Temperature and humidity after removed from the test chamber. Note 3 :Vibration test will be conducted to the product itself without putting it in a container. DMF-50840NB-FW-ASE-BFN (BF) No. 2005-0302 OPTREX CORPORATION Page 12/186.Appearance Standards 6.1.Inspection conditions The LCD shall be inspected under 40W white fluorescent light. The distance between the eyes and the sample shall be more than 30cm. All directions for inspecting the sampie should be within 45against perpendicular line. TN 6.2. Definition of applicable Zones i x X=122.0mm Y ; ..AZone. } | Bezel F B Zone C Zone C Zone A Zone : Active display area B Zone : Area from outside of "A Zone" to validity viewing area C Zone : Rest parts A Zone + B Zone = Validity viewing area DMF-50840NB-FW-ASE-BFN (BF) No. 2005-0302 OPTREX CORPORATION Page 13/186.3.Standards No. Parameter Criteria 1 Black and (1) Round Shape White Spots, Zone Acceptable Number Foreign Substances Dimension (mm) A B Cc D <@.1 * * * 0.1 W * * * 2.02L 0.05 > W 3 3 * 1.02>L 0.1 >W 3 3 * - 0.1 As per the sketch of left hand. (2) Dot Shape (with Projection) Should not be connected to next dot. (3) Pin Hole Oey (X+Y)/2 < 0.2mm (Less than 0.1mm is no counted.) (4) Deformation 1 Ye. (X+Y) /2 < 0.2mm < xX Total acceptable number : 1/dot, 5/cell (Defect number of (4) : 1pc.) 4 Polarizer Scratches | Not to be conspicuous defects. Polarizer Dirts If the stains are removed easily from LCDP surface, the module is not defective. 6 Complex Foreign Black spots, line shaped foreign substances or air bubbles between Substance Defects | glass & polarizer should be 5pcs maximum in total. 7 Distance between D< 0.2: 20mm or more Different Foreign Substance Defects 0.2