3 Hz to > 3000 MHz in two overlapping ranges
High input sensitivity over the full frequency range
High impedance measurement up to 125 MHz
Reciprocal measurement technique gives superior resolution
Period measurement from 3 Hz to 125 MHz
Selectable measurement time; display hold function
Noise filter for low frequency measurements
Large 8.5 digit display with full range of annunciators
Battery operation; handheld format with tilt-stand
Push-to-measure function with auto power-down
Wide frequency range and high resolution
The PFM3000 offers high sensitivity frequency measurement from 3Hz to more
than 3GHz in two overlapping ranges. Period measurement is also provided
from 8ns to 330ms.
The PFM3000 uses a continuous reciprocal measurement technique to provide
high resolution at all frequencies with rapid update.
It offers high sensitivity across the whole frequency range. A low pass filter
can be selected to reduce high frequency signal noise at lower frequencies.
A Large and clear display
Despite its compact dimensions, the PFM3000 incorporates a large 8.5 digit
LCD. Annunciators are provided for measurement function, measurement
time, overflow, trigger activity, low battery, and measurement units.
INPUT SPECIFICATIONS
Input A
Input Coupling: AC or DC
Input Impedance: 1MW//25pF (DC or AC coupled), or 50W (AC coupled only)
Attenuation: 1:1 or 5:1
Active Edge: Rising or falling, or width high or low
Low Pass Filter: 50kHz cut-off, or None
Frequency Range: 0.001Hz to > 125MHz (1MW, DC coupled)
< 30Hz to > 125MHz (1MW, AC coupled)
< 500kHz to > 125MHz (50W, AC coupled).
Sensitivity: Sinewave - 15mVrms 30Hz to 100MHz,
25mV to 125MHz at optimum threshold adjustment.
Signal Range: 1MW, DC - 0 to 3.3V (1:1) or 1 to 12V (5:1),
1MW, AC - up to 1Vrms (3Vpp) (1:1) or up to 4Vrms (12Vpp) (5:1)
50W, AC - up to 1V rms above 300kHz
Trigger Threshold: DC coupled - 0 to 2V (1:1) or 0 to 10V (5:1)
AC coupled - Average ± 200mV (1:1) or ± 1V (5:1)
Input B
Input Impedance: 50W (AC coupled)
Frequency Range: <80MHz to >3000MHz
Sensitivity: Sinewave - 25mVrms 2GHz to 6GHz
Signal Range: <0dBm recommended, +13dBm (1Vrms) maximum
Input C (TF960 only)
Input Impedance: 50W (AC coupled)
Frequency Range: <1800MHz to >6000MHz
Sensitivity: Sinewave - 12mVrms 80MHz-2GHz,
25mV to 2.5GHz, 50mVrms to 3GHz
Signal Range: <0dBm recommended, +13dBm (1Vrms) maximum
External Reference
Input Impedance: >100kW, AC coupled
Frequency: 10MHz
Signal Level: TTL, 3Vpp to 5Vpp CMOS or 1 to 2Vrms sinewave
Maximum Input Voltage
Input A and Input B: 30Vdc; 30Vrms 50Hz/60Hz reducing to 1Vrms above 1MHz
Note that the inputs will not be damaged if subjected to an accidental short-term connection to a
50/60Hz line voltage not exceeding 250V rms.
MEASUREMENT FUNCTIONS
Frequency
A Input Range: 0.001Hz (DC coupled) to >125MHz
B Input Range: 80MHz to >3000MHz
Resolution: up to 10 digits (see Note) or 0.001Hz
Period
A Input Range: 8ns to 100s (DC coupled)
B Input Range: 333ps to 12.5ns
Resolution: up to 10 digits (see Note)
Pulse Width Mode (Input A only)
Functions: Width high, width low, ratio H:L (high time to low time) and duty cycle
Pulse Width Range: 40ns to 1000s
Averaging: Automatic within measurement time selected, up to 50 pulses
Resolution: 20ns for one pulse; up to 1ns or 10 digits with multiple pulse averaging
0.01% for Ratio H:L and Duty Cycle,
Total Count (Input A only)
Count Range: 1 to 9 999 999 999
Minimum Width: 8ns
Frequency Ratio B:A
Resolution: Equal to the resolution of the two frequency measurements,
If the ratio exceeds 10 digits, 6 digits and the exponent are displayed
Measurement Time
Selectable as 100s, 10s, 1s or 0.3s. The instrument displays the average value of the input
signal over the measurement time selected, updated every 2s, 1s, 0.5s or 0.3s respectively.
The hardware captures the count values and continues measuring without any dead time.
Resolution
The displayed resolution depends upon measurement time and input frequency. The basic
resolution of period is 8 digits for every 2 seconds of measurement time. Frequency resolu-
tion is the reciprocal of period resolution. Usable resolution can be reduced by noise at low
frequencies.
Accuracy
Measurement accuracy is timebase accuracy + measurement resolution + 2 counts.
TIMEBASE
Measurement Clock: 50MHz
Internal Reference: 10MHz TCXO with electronic calibration adjustment (> +/- 8ppm)
Temperature Stability: Better than ± 1ppm over rated temperature range
Initial Error: < ± 0.2ppm at 25ºC
Ageing Rate: <± 1ppm/year
OPERATING FACILITIES
Noise Filter
The Filter key controls a low pass filter, with a cut-off frequency of about 50kHz, to ensure
more stable readings at low frequencies.
Specifications - TF930/960
PFM3000 - low-cost 3GHz counter
Low power consumption and push-to-measure
Despite its wide frequency range the PFM3000 has a power consumption that
enables it to operate for many hours from a PP3 size battery.
A push-to-measure capability gives an instantaneous reading followed by
an automatic power down after 15 seconds. This provides greatly extended
battery life where continuous monitoring of the signal is not required.
Bench-top use
The PFM3000 has the performance needed for many bench-top applications,
and its built-in tilt stand sets the display at a convenient angle.