E IN G L LO N O TA A C SMA Series Subminiature RF Connectors Screw-on mating Frequency range DC-18 GHz High performance Rugged construction APPLIED ENGINEERING PRODUCTS 104 John W. Murphy Drive * P.O. Box 510 * New Haven, CT 06513 (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * e-mail: aepsales@aepconnectors.com SMA Subminiature Connectors Click on any line below to go directly to the appropriate page Contents Technical Information Interfaces and specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Cable attachment methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Cable Connectors Plugs for semi-rigid cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Plugs for flexible cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Jacks for semi-rigid cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Jacks for flexible cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Bulkhead jacks for semi-rigid cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Bulkhead jacks for flexible cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Panel jacks for semi-rigid cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Panel jacks for flexible cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Receptacles Panel jack receptacles . . . . . . . . Receptacles for .025" microstrip Receptacles for .010" microstrip Panel plug receptacles. . . . . . . . Bulkhead jack receptacles . . . . . Knurl mount receptacles . . . . . . P.C. board receptacles . . . . . . . . Stripline receptacles . . . . . . . . . Hermetic seal launchers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 21 22 23 26 28 29 30 31 Adapters Straight adapters within series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Right angle adapters within series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Tee adapters within series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Resistive Terminations Plug resistive termination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Cable Assembly Instructions Connectors for flexible cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Connectors for semi-rigid cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Assembly Tooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Mounting Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Index by AEP Part Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 About AEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Other AEP Product Lines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 APPLIED ENGINEERING PRODUCTS 104 John W. Murphy Drive * P.O. Box 510 * New Haven, CT 06513 (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * e-mail: aepsales@aepconnectors.com 2 SMA Connectors AEP SMA connectors are available with gold-plated bodies, or with passivated or nickel-plated bodies for greater economy. The coupling nuts of plug connectors are passivated in all cases. Our unique mechanical captivation method (see page 5) greatly reduces RF leakage by eliminating epoxy fill hoes in the connector body. Specifications (MIL-PRF-39012 as applicable) Materials: Body components: Stainless steel per ASTM-A-582, type 303. Contacts: Beryllium copper per ASTM-B-196, Condition HT. Insulators: Teflon TFE per ASTM-D-1710. Gaskets: Silicone rubber per ZZ-R-765, Class 2B, grade 65-75. Finish: Center contacts: Gold plated per current revision of MIL-PRF-39012* Other metal parts: Gold plated, passivated, or nickel plated to meet current MIL-PRF-39012 corrosion requirements.* Electrical: VSWR Straight cable plugs and jacks): Cable VSWR Frequency RG-178 1.20 + (.025 x F[GHz]) DC-12.4 GHz RG-316 1.15 + (.020 x F[GHz]) DC-12.4 GHz RG-142 1.15 + (.010 x F[GHz]) DC-12.4 GHz RG-402(1) 1.05 + (.008 x F[GHz]) DC-18 GHz RG-402(2) 1.05 + (.010 x F[GHz]) DC-18 GHz RG-405(1) 1.07 + (.008 x F[GHz]) DC-18 GHz RG-405(2) 1.07 + (.010 x F[GHz]) DC-18 GHz (1) Non-captive contact. (2) Captive contact. VSWR specifications not applicable to non-cabled connectors. Impedance: 50. Frequency range: DC-8, 12.4, or 18 GHz (varies with cable type). Insulation Resistance: 5,000 megohms minimum. Electrical (continued): Voltage Rating: 250VRMS @ sea level (RG-178 cable); 335VRMS @ sea level (RG-316 cable). Dielectric Withstanding Voltage: Per MIL-STD-202, Method 301. Contact Resistance: 3 milliohms maximum. RF highpot: 335-675 VRMS @ 5-7.5 MHz (varies with cable type). RF leakage: -60 dB min @ 2-3 GHz. Insertion loss: .44 dB max to 6 GHz. Mechanical: Force to engage/disengage: 2 pounds max. Force to engage/disengage (female contacts): (After 5 insertions of .375" diameter pin, .040" min depth) Insertion force for .037 min diameter pin, 2 pounds max. Withdrawal force for .0355" max diameter pin, 1 ounce min. Contact retention: 6 pounds min axial force (captive types). Durability: 500 mating cycles. Environmental (MIL-STD-202): Temperature range: -65 C to +165 C. Corrosion: Method 101, condition B, 5% salt solution. Vibration (Method 204): Condition B. Mechanical shock (Method 213): Condition B. Thermal shock (Method 107): Condition B. *These specifications change periodically with updates to MIL-PRF-39012 requirements. Contact factory for latest specifications. Interface Dimensions Plug APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 Jack www.aepconnectors.com * aepsales@aepconnectors.com 3 SMA Cable Attachment Methods Semi-Rigid Cable Direct Solder (cable center conductor used as contact): This type of cable attachment ensures the best possible electrical performance because there are no discontinuities introduced by contact geometry changes. It is best used in applications not requiring frequent mating and unmating, because the pointed center conductor and exposed cable jacket will shed metal chips when mated with SMA female connectors. Direct Solder (with contact and insulator): Although this cable attachment exhibits higher VSWR than types without contacts, it provides an outer conductor that does not have the copper cable jacket exposed to mating forces. This, along with the beryllium-copper contact, ensures clean interfaces through many mating cycles. Direct Solder (with captive contact): These connectors have electrical performance similar to types with non-captive contacts, but with faster and easier cable assembly. The cable is simply stripped and inserted into the connector, and the cable jacket soldered to the connector. The proper contact gap is automatically maintained, and no contact soldering is required. Solder-clamp: This attachment is most useful for right angle plugs and bulkhead jacks. After the connector is assembled to the cable jacket, it can be repositioned relative to the cable by loosening the clamp nut. Electrical performance is similar to direct-solder plugs with contacts. APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 4 SMA Cable Attachment Methods Flexible Cable Crimp (non-captive contact): This attachment method provides the best possible electrical performance, and the fastest assembly. Solder type connectors for flexible cable have the same construction, but add a hole in the side of the crimp sleeve for soldering the cable braid to the connector. We do not recommend the use of solder type connectors with flexible cable--the heat from soldering may damage the cable dielectric. Crimp (captive contact): This attachment method mechanically captivates the center contact to eliminate movement during cable flexure or thermal stress. Clamp (captive contact): These connectors can be assembled without special tooling, and are field replaceable. SMA Captivation All AEP SMA receptacles and adapters use our unique mechanical captivation for contacts and insulators. This method provides retention strength to meet MIL-PRF-39012 requirements, and eliminates RF leakage from epoxy fill holes. The contact barbs and body staking are designed and located to provide electrical performance that equals or exceeds epoxy-captivated types. APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 5 SMA Cable Plugs for Semi-Rigid Cable Click on part number to go directly to cable assembly instructions Straight Plugs Continued on next page APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 6 SMA Cable Plugs for Semi-Rigid Cable Click on part number to go directly to cable assembly instructions Straight Plugs Right Angle Plugs APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 7 SMA Cable Plugs for Flexible Cable Click on part number to go directly to cable assembly instructions Straight Plugs Substitute the appropriate cable group number for "XX" when ordering: GROUP 01 02 03 CABLE TYPES RG142, RG223, M17/60, M17/84, M17/158 RG178, RG196, M17/93, M17/169 RG174, RG179, RG316, M17/113, M17/119, M17/172, M17/189 APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 GROUP CABLE TYPES 04 RG180, RG195, M17/95 05 RG178DS, RG196DS GROUP 06 19 CABLE TYPES RG58, RG141, RG303, M17/111, M17/155 RG174DS, RG316DS, M17/151, M17/152, Times RD-316 www.aepconnectors.com * aepsales@aepconnectors.com 8 SMA Cable Plugs for Flexible Cable Click on part number to go directly to cable assembly instructions Right Angle Plugs Substitute the appropriate cable group number for "XX" when ordering: GROUP 01 02 03 CABLE TYPES RG142, RG223, M17/60, M17/84, M17/158 RG178, RG196, M17/93, M17/169 RG174, RG179, RG316, M17/113, M17/119, M17/172, M17/189 APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 GROUP CABLE TYPES 04 RG180, RG195, M17/95 05 RG178DS, RG196DS GROUP 06 19 CABLE TYPES RG58, RG141, RG303, M17/111, M17/155 RG174DS, RG316DS, M17/151, M17/152, Times RD-316 www.aepconnectors.com * aepsales@aepconnectors.com 9 SMA Cable Jacks for Semi-Rigid Cable Click on part number to go directly to cable assembly instructions Straight Jacks APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 10 SMA Cable Jacks for Flexible Cable Click on part number to go directly to cable assembly instructions Straight Jacks Substitute the appropriate cable group number for "XX" when ordering: GROUP 01 02 03 CABLE TYPES RG142, RG223, M17/60, M17/84, M17/158 RG178, RG196, M17/93, M17/169 RG174, RG179, RG316, M17/113, M17/119, M17/172, M17/189 APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 GROUP CABLE TYPES 04 RG180, RG195, M17/95 05 RG178DS, RG196DS GROUP 06 19 CABLE TYPES RG58, RG141, RG303, M17/111, M17/155 RG174DS, RG316DS, M17/151, M17/152, Times RD-316 www.aepconnectors.com * aepsales@aepconnectors.com 11 SMA Bulkhead Jacks for Semi-Rigid Cable Click on part number to go directly to cable assembly instructions Straight Jacks Right Angle Jack APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 12 SMA Bulkhead Jacks for Flexible Cable Click on part number to go directly to cable assembly instructions Straight Jacks Right Angle Jack Substitute the appropriate cable group number for "XX" when ordering: GROUP 01 02 03 CABLE TYPES RG142, RG223, M17/60, M17/84, M17/158 RG178, RG196, M17/93, M17/169 RG174, RG179, RG316, M17/113, M17/119, M17/172, M17/189 APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 GROUP CABLE TYPES 04 RG180, RG195, M17/95 05 RG178DS, RG196DS GROUP 06 19 CABLE TYPES RG58, RG141, RG303, M17/111, M17/155 RG174DS, RG316DS, M17/151, M17/152, Times RD-316 www.aepconnectors.com * aepsales@aepconnectors.com 13 SMA Panel Jacks for Semi-Rigid Cable Click on part number to go directly to cable assembly instructions Straight Jacks APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 14 SMA Panel Jacks for Flexible Cable Click on part number to go directly to cable assembly instructions Straight Jacks Substitute the appropriate cable group number for "XX" when ordering: GROUP 01 02 03 CABLE TYPES RG142, RG223, M17/60, M17/84, M17/158 RG178, RG196, M17/93, M17/169 RG174, RG179, RG316, M17/113, M17/119, M17/172, M17/189 APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 GROUP CABLE TYPES 04 RG180, RG195, M17/95 05 RG178DS, RG196DS GROUP 06 19 CABLE TYPES RG58, RG141, RG303, M17/111, M17/155 RG174DS, RG316DS, M17/151, M17/152, Times RD-316 www.aepconnectors.com * aepsales@aepconnectors.com 15 SMA Straight Panel Jack Receptacles Extended Contact and Insulator APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 16 SMA Straight Panel Jack Receptacles Solder Pot Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 17 SMA Straight Panel Jack Receptacles Tab Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 18 SMA Straight Panel Jack Receptacles Slotted Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 19 SMA Right Angle Panel Jack Receptacles Solder Pot Contact Tab Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 20 SMA Receptacles for .025" Microstrip Standard SMA receptacles with tab contacts have the tab milled from a .050" diameter round contact. This .050" diameter is flush with the rear insulator of the connector. When these connectors are used with .025" thick microstrip, a capacitive coupling can be introduced because of the close proximity of the microstrip ground plane to the outer diameter of the contact. These receptacles eliminate the coupling by reducing the contact rear diameter to .025". The insulator diameter at the rear of the connector is reduced to .083" to maintain 50 impedance. Tab Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 21 SMA Receptacles for .010" Microstrip These connectors have .010" diameter contact extensions for good electrical transition to narrow microstrip lines. The reduced-diameter insulators are extended beyond the flange to maintain 50 impedance through the microstrip package wall. All have captive contacts. Round Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 22 SMA Panel Plug Receptacles Straight--Extended Contact and Insulator APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 23 SMA Panel Plug Receptacles Straight--Solder Pot Contact Right Angle--Solder Pot Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 24 SMA Panel Plug Receptacles Straight--Tab Contact Right Angle--Tab Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 25 SMA Bulkhead Jack Receptacles Straight--Solder Pot Contact Right Angle--Solder Pot Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 26 SMA Bulkhead Jack Receptacles Straight--Extended Contact and Insulator Straight--Solder Pot Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 27 SMA Knurl Mount Receptacles These knurl mount receptacles can provide an economical alternative to flange mounted connectors, and are especially useful in dense packaging applications. They should be used in panels at least .100" thick. Straight Jack--Extended Contact and Insulator Straight Jack--Solder Pot Contact Straight Jack--Tab Contact Straight Plug--Tab Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 28 SMA P.C. Board Receptacles Straight Jack Right Angle Jack Straight Plug Right Angle Plug APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 29 SMA Stripline Receptacles Straight Jacks Right Angle Jack Straight Plug APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 30 SMA Hermetic Seal Launchers AEP SMA hermetic seal launchers are designed to fit hermetic seals with .012" to .036" pin diameters. Connectors for use with .012--.018" pins feature an internal body structure that compensates electrically for the stepdown in diameter from the connector interface to the seal outer diameter, as shown in the illustration. These units also incorporate a conductive-elastomer EMI gasket to prevent RF leakage at the interface between the connector flange and the MIC package. Connector / seal design--connectors for use with .012-.018" diameter pins Connectors for seals with .020" or .036" pin diameters have straight-though body geometry, and do not use EMI gaskets. Passivated stainless steel body finish is standard for this series; gold-plated bodies are available as an option. Electrical Performance Data Test setup: Two connectors (P/N 9044-9513-000) mounted back-to-back on fixture incorporating hermetic seal (P/N 920-55). Precision SMA plug termination used as load. The VSWR plot below is for the connector/fixture combination; data for a single connector can be extrapolated by taking the square root of the reading at a given frequency. Insertion loss readings should be divided by two to obtain performance for a single connector. Electrical performance in actual use may vary based on the characteristics of the pin-to-line transition. VSWR Insertion loss (dB) See next page for hermetic seal specifications and mounting dimensions. APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 31 Hermetic Seal Specifications Materials: All metal parts: Kovar. Glass: Corning glass as noted: P/N Glass type 920-55 7052 920-56 7070 920-69 7052 920-82 7070 920-92 7052 Temperature range: -65-250 C. Impedance: 50 1. Frequency range: DC-26 GHz. Insertion loss: .1 dB max. to 12.4 GHz; .2 dB max. to 18 GHz; .25 dB max. to 26 GHz. Finish: All metal parts: Gold plated per MIL-G-45204 type II, grade C, class 1, over nickel per MIL-C-26074, class 1, over copper per MIL-C-14550. VSWR: Dependent on application. Hermeticity: Greater than 1 x 10-8 cc/second @ 1 atmosphere. Voltage rating: 335 VRMS max. @ sea level. Solderability: Per MIL-Std-202, Method 209. Current: 500 mA. Meniscus: .005" max. Dielectric Withstanding Voltage: 1000 VRMS @ sea level. Pin concentricity: .003" T.I.R. Insulation resistance: 100K megohms (@25 C) Mounting Dimensions Notes: 1) Front of seal and solder should be flush to .005" above mounting surface. 2) Diameters ("D") in chart are for 50 impedance; Teflon dielectric diameters are for applications which use a support insulator for the hermetic seal pin (user option). APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 Pin Diameter .012 .015 .018 "D" (Air dielectric) .028 .035 .041 "D" (Teflon dielectric) .040 .050 .059 .020 .046 .066 www.aepconnectors.com * aepsales@aepconnectors.com 32 SMA Hermetic Seal Launchers For hermetic seals with .012" diameter pins Straight Jacks These units accept hermetic seal pin diameters .011-.015" Hermetic Seal and Accessory Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 33 SMA Hermetic Seal Launchers For hermetic seals with .012" diameter pins Straight Jacks These units accept hermetic seal pin diameters .011-.015" Hermetic Seal and Accessory Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 34 SMA Hermetic Seal Launchers For hermetic seals with .012" diameter pins Straight Plugs These units accept hermetic seal pin diameters .011-.015" Hermetic Seal and Accessory Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 35 SMA Hermetic Seal Launchers For hermetic seals with .015" diameter pins Straight Jacks These units accept hermetic seal pin diameters .014-.016" Hermetic Seal and Accessory Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 36 SMA Hermetic Seal Launchers For hermetic seals with .015" diameter pins Straight Jacks These units accept hermetic seal pin diameters .014-.016" Hermetic Seal and Accessory Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 37 SMA Hermetic Seal Launchers For hermetic seals with .015" diameter pins Straight Plugs These units accept hermetic seal pin diameters .014-.016" Hermetic Seal and Accessory Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 38 SMA Hermetic Seal Launchers For hermetic seals with .018" diameter pins Straight Jacks These units accept hermetic seal pin diameters .016-.020" Hermetic Seal and Accessory Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 39 SMA Hermetic Seal Launchers For hermetic seals with .018" diameter pins Straight Jacks These units accept hermetic seal pin diameters .016-.020" Hermetic Seal and Accessory Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 40 SMA Hermetic Seal Launchers For hermetic seals with .018" diameter pins Straight Plugs These units accept hermetic seal pin diameters .016-.020" Hermetic Seal and Accessory Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 41 SMA Hermetic Seal Launchers For hermetic seals with .020" diameter pins Straight Jacks Hermetic Seal and Accessory Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 42 SMA Hermetic Seal Launchers For hermetic seals with .020" diameter pins Straight Jacks Hermetic Seal and Accessory Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 43 SMA Hermetic Seal Launchers For hermetic seals with .036" diameter pins Straight Jacks Hermetic Seal and Accessory Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 44 SMA Hermetic Seal Launchers For hermetic seals with .036" diameter pins Straight Jacks Hermetic Seal and Accessory Contact APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 45 SMA Adapters Straight Adapters APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 46 SMA Adapters Right Angle Adapters APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 47 SMA Adapters Tee Adapters SMA Terminations Plug Termination APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 48 Cable Assembly Instructions Clamp type connectors for flexible cable Straight Connectors--Flexible Cable Right Angle Connectors--Flexible Cable Parts list Insulator Body assembly Insulator Ferrule Compression washer Cap Ferrule Compression washer Body assembly Parts list Backnut Backnut Contact (male or female) 1 1 --Trim cable per trim code below; tin end of center conductor. --Slide backnut onto cable. Slide compression washer onto cable in the orientation shown until it stops against cable jacket. --Flare cable braid by rotating dielectric and slide ferrule under braid. --Trim cable per trim code below; tin end of center conductor. --Slide backnut onto cable. Slide compression washer onto cable in the orientation shown until it stops against cable jacket. --Flare cable braid by rotating dielectric and slide ferrule under braid. 2 2 --Press ferrule against compression washer. --Trim excess braid flush with outer diameter of compression washer and ferrule. --Assemble insulator over cable center conductor and dielectric. 3 --Press ferrule against compression washer. --Trim excess braid flush with outer diameter of compression washer and ferrule. --Assemble insulator over cable center conductor and dielectric. 3 Solder --Assemble contact onto cable center conductor. --Solder contact to center conductor by heating rear of contact (do not feed additional solder through inspection hole in contact). 4 --Insert cable assembly into body assembly. Tighten to 140-150 inch-ounces torque. (Hold cable/hardware assembly stationary and rotate body when tightening.) --Solder center conductor into notch in rear of contact with .025-.032" diameter chisel-tip soldering iron. --Solder should cover center conductor, but not extend over top of notch in contact, or exceed contact diameter. --Insert cable assembly into body assembly. Tighten to 140-150 inch-ounces torque. (Hold cable/hardware assembly stationary and rotate body when tightening.) Cable Trim Dimensions Dielectric 4 Braid Center conductor Jacket A B C CONNECTOR TYPE STRAIGHT CONNECTORS A .100 B .100 C .230 RIGHT ANGLE CONNECTORS .100 .275 .400 APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 --Place insulator in body cavity, and press cap into place. Properly assembled cap will be slightly below end of body assembly. www.aepconnectors.com * aepsales@aepconnectors.com 49 Cable Assembly Instructions Crimp type connectors for flexible cable Straight Connectors--Captive Contact Straight Connectors--Non-captive Contact Body assembly Parts list Backnut/crimp tail Body assembly Insulator Heat-shrink tubing Heat-shrink tubing (optional) Contact (male or female) Contact Crimp sleeve 1 Parts list .015" gap 1 --Trim cable per trim code below; tin end of center conductor. --Slide heat-shrink tubing and crimp sleeve over cable. --Flare cable braid by rotating dielectric and slide cable into crimp tail. 2 --Position cable so braid touches rear of back nut. --Slide crimp sleeve forward to touch rear of back nut. --Crimp braid with appropriate die size from chart below. Crimp sleeve --Trim cable per trim code below; tin end of center conductor. --Slide heat-shrink tubing and crimp sleeve over cable. --Assemble contact onto center conductor, shim to maintain .015" gap between rear of contact and cable dielectric. --Solder contact to center conductor by heating rear of contact (do not feed additional solder through inspection hole in contact). 2 3 --Assemble insulator and contact onto cable dielectric and center conductor. --Solder contact to center conductor by heating rear of contact (do not feed additional solder through inspection hole in contact). --Flare cable braid by rotating dielectric and slide cable into tail of body assembly. --Position cable so braid touches rear step of body assembly. --Slide crimp sleeve forward to touch rear of body assembly. --Crimp braid with appropriate die size from chart below. 3 4 --Insert cable assembly into body assembly. Tighten to 140-150 inch-ounces torque. (Hold cable/hardware assembly stationary and rotate body when tightening.) --Slide shrink tubing over crimp sleeve and shrink to fit. --Slide shrink tubing over crimp sleeve and shrink to fit. Cable Trim Dimensions Crimp Die Sizes CABLE GROUP 01 02 HEX DIE SIZE .213 .128 03 .128 04 .156 05 .128 06 19 Dielectric Braid Center conductor Jacket A B C .213 CONNECTOR TYPE Captive contact A .100 B .470 C .720 .156 Non-captive contact .100 .160 .390 APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 50 Cable Assembly Instructions Crimp type connectors for flexible cable Right Angle Connectors--Flexible Cable Heat-shrink tubing Cap (optional) Insulator Cable Trim Dimensions Dielectric Braid Center conductor Jacket Body assembly A B Parts list C Crimp sleeve CONNECTOR TYPE RIGHT ANGLE CONNECTORS 1 A .100 B .230 C .500 Crimp Die Sizes --Trim cable per trim code below; tin end of center conductor. --Slide heat-shrink tubing and crimp sleeve over cable. --Flare cable braid by rotating dielectric and slide cable into crimp tail. 2 --Position cable so braid touches rear of body assembly. --Slide crimp sleeve forward to touch rear of body assembly. --Crimp braid with appropriate die size from chart below. 3 CABLE GROUP 01 02 HEX DIE SIZE .213 .128 03 .128 04 .156 05 .128 06 .213 19 .156 Solder --Solder center conductor into notch in rear of contact with .025-.032" diameter chisel-tip soldering iron. --Solder should cover center conductor, but not extend over top of notch in contact, or exceed contact diameter. 4 --Place insulator in body cavity, and press cap into place. Properly assembled cap will be slightly below end of body assembly. --Slide shrink tubing over crimp sleeve and shrink to fit. APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 51 Cable Assembly Instructions Solder-clamp connectors for semi-rigid cable Straight Connectors--Semi-Rigid Cable Parts list Solder Ferrule Insulator Body assembly Right Angle Connectors--Semi-Rigid Cable Solder Ferrule Cap Backnut Insulator Backnut Body assembly Parts list Contact (male or female) 1 1 Solder Solder --Trim cable per trim code below; tin end of center conductor. --Slide backnut over cable. Slide solder ferrule over cable until it stops against cable jacket. --Solder cable jacket to ferrule. 2 --Trim cable per trim code below; tin end of center conductor. --Slide backnut over cable. Slide solder ferrule over cable until it stops against cable jacket. --Solder cable jacket to ferrule. 2 --Assemble insulator and contact onto cable dielectric and center conductor. If insulator is not flush against solder ferrule due to dielectric extrusion, retrim dielectric. --Solder contact to center conductor by heating rear of contact (do not feed additional solder through inspection hole in contact). 3 --Insert cable assembly into body assembly. Tighten to 90-100 inch-ounces torque. (Hold cable/hardware assembly stationary and rotate body when tightening.) Solder --Insert cable assembly into body assembly. Tighten to 90-100 inch-ounces torque. (Hold cable/hardware assembly stationary and rotate body when tightening.) --Solder center conductor into notch in rear of contact with .025-.032" diameter chisel-tip soldering iron. --Solder should cover center conductor, but not extend over top of notch in contact, or exceed contact diameter. 3 Cable Trim Dimensions Center conductor --Place insulator in body cavity, and press cap into place. Properly assembled cap will be slightly below end of body assembly. Jacket Dielectric A B CONNECTOR TYPE Straight connectors A .100 B .135 Right angle connectors-.085" cable .080 .170 Right angle connectors-.141" cable .125 .290 APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 52 Cable Assembly Instructions Direct solder connectors for semi-rigid cable Straight Connectors--Non-captive Contact Parts list Body assembly Straight Connectors--Captive Contact 1 --Trim cable per trim code below; chamfer end of center conductor 70-90. 2 --Insert cable into body assembly until it stops. --Solder cable jacket to connector body. Contact 1 .015" gap (for .085" diameter cable) .010" gap (for .141" diameter cable) --Trim cable per trim code below; tin end of center conductor. --Shim to maintain proper gap between rear of contact and cable dielectric. --Solder contact to center conductor by heating rear of contact (do not feed additional solder through inspection hole in contact). Right Angle Connectors Insulator Cap Body assembly 2 Parts list Solder --Slide cable into connector until it stops. --Solder cable jacket to connector body. 1 --Trim cable per trim code below; tin end of center conductor. --Insert trimmed cable into body until jacket bottoms on step inside body and center conductor is in contact slot. --Solder cable jacket to body assembly. Cable Trim Dimensions Center conductor Jacket Dielectric Solder Solder A B 2 CONNECTOR TYPE Straight connectors A .090 B .090 Right angle connectors .080 .170 --Solder center conductor into notch in rear of contact with .025-.032" diameter chisel-tip soldering iron. --Solder should cover center conductor, but not extend over top of notch in contact, or exceed contact diameter. 3 --Place insulator in body cavity, and press cap into place. Properly assembled cap will be slightly below end of body assembly. APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 53 Cable Assembly Instructions Direct solder connectors for semi-rigid cable P/N 9301-1063-009 Parts list P/N 9301-1063-109 Parts list Coupling nut "C" ring Gasket Body 1 Coupling nut "C" ring Gasket Body 1 Solder Gasket Gasket --Trim cable per trim code below; point end of center conductor to 45 as shown. --Slide backnut over cable. Slide body over cable until trimmed end of cable is flush with front of body. --Solder cable jacket to body. Retrim cable dielectric flush with body if it has extruded due to heat from soldering. --Assemble gasket into groove on body. 2 --Trim cable per trim code below; point end of center conductor to 45 as shown. --Slide backnut over cable. Slide body over cable until trimmed end of cable jacket stops against step in body. --Solder cable jacket to body. Retrim cable dielectric flush with body if it has extruded due to heat from soldering. --Assemble gasket into groove on body. 2 "C" ring --Slide coupling nut forward until it stops and assemble "C" ring into groove. Solder "C" ring --Slide coupling nut forward until it stops and assemble "C" ring into groove. Cable Trim Dimensions Dielectric Jacket Center conductor A B CONNECTOR TYPE 9301-1063-009 A .090 B .090 9301-1063-109 .090 .180 APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 54 Assembly Tooling Crimp tools DESCRIPTION Crimp tool with Crimp tool with Crimp tool with Crimp tool with Crimp tool with TA-0105 .128" .156" .105" .255" .255" and .213" hex dies hex die and .128" hex dies and .068" hex dies hex die AEP P/N TA-0007 TA-0071 TA-0105 TA-0190 TA-0234 Torque Wrench DESCRIPTION Torque wrench with 5/16" jaw for SMA coupling nuts; 8 inch-pounds torque TA-0436 AEP P/N TA-0397 Capping Press CP-1 DESCRIPTION AEP P/N Capping tool (arbor press) with base for SMA right angle plugs Contact Factory Capping tool (arbor press) with base for SMA right angle jacks Contact Factory Mounting Dimensions Bulkhead Receptacles P.C. Board Receptacles .257 dia. .100 typ. .238 .063 dia. .200 typ. .067 dia. min. (typ.) APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 55 Index by Part Number P/N 5903-1503-000 . 5903-9503-000 . 5905-1503-000 . 5905-9503-000 . 5909-1103-000 . 5909-9103-000 . 5916-1103-603 . 5916-9103-603 . 5917-1103-000 . 5917-9103-000 . 5918-1103-000 . 5918-9103-000 . 5919-1503-000 . 5919-1503-001 . 5919-1503-003 . 5919-9503-000 . 5919-9503-001 . 5919-9503-003 . 9001-1023-0XX 9001-1033-0XX 9001-9023-0XX 9002-1023-0XX . 9002-1033-0XX . 9002-9023-0XX . 9003-1213-0XX . 9003-9213-0XX . 9004-1113-000 . 9004-1213-000 . 9004-9113-000 . 9004-9213-000 . 9007-1113-000 . 9007-1213-000 . 9007-9113-000 . 9007-9213-000 . 9008-1113-000 . 9008-1213-000 . 9008-9113-000 . 9008-9213-000 . 9009-1113-000 . 9009-1213-000 . 9009-9113-000 . 9009-9213-000 . 9013-1113-000 . 9013-9113-000 . 9030-1023-0XX . 9030-1033-0XX . 9030-9023-0XX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page . 48 . 48 . 48 . 48 . 46 . 46 . 46 . 46 . 46 . 46 . 46 . 46 . 47 . 47 . 47 . 47 . 47 . 47 . . 8 . . 8 . . 8 . 11 . 11 . 11 . 30 . 30 . 16 . 16 . 16 . 16 . 16 . 16 . 16 . 16 . 16 . 16 . 16 . 16 . 23 . 23 . 23 . 23 . 27 . 27 . 13 . 13 . 13 P/N 9031-1023-0XX . 9031-1033-0XX . 9031-9023-0XX . 9033-1113-000 . 9033-1213-000 . 9033-9113-000 . 9033-9213-000 . 9034-1213-0XX . 9034-9213-0XX . 9035-1513-0XX . 9035-9513-0XX . 9043-1523-0XX 9043-1533-0XX 9043-9523-0XX 9044-9513-000 . 9044-9513-001 . 9045-9513-000 . 9045-9513-001 . 9046-9513-000 . 9046-9513-001 . 9047-9513-000 . 9047-9513-001 . 9048-9513-000 . 9049-9513-000 . 9050-9513-000 . 9051-9513-000 . 9055-1113-000 . 9055-1213-000 . 9055-9113-000 . 9055-9213-000 . 9056-1113-000 . 9056-9113-000 . 9062-9513-000 . 9062-9513-001 . 9068-9513-000 . 9074-9513-000 . 9076-1113-000 . 9076-1213-000 . 9076-9113-000 . 9076-9213-000 . 9079-9513-000 . 9079-9513-001 . 9080-9513-000 . 9080-9513-001 . 9081-9513-000 . 9101-1573-0XX 9101-9573-0XX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page . 15 . 15 . 15 . 28 . 28 . 28 . 28 . 30 . 30 . 30 . 30 . . 9 . . 9 . . 9 . 34 . 37 . 33 . 36 . 35 . 38 . 35 . 38 . 40 . 39 . 41 . 41 . 23 . 23 . 23 . 23 . 27 . 27 . 33 . 36 . 39 . 39 . 16 . 16 . 16 . 16 . 33 . 36 . 34 . 37 . 40 . . 8 . . 8 P/N 9102-1573-0XX . 9102-9573-0XX . 9104-1113-000 . 9104-1213-000 . 9104-9113-000 . 9104-9213-000 . 9107-1113-000 . 9107-1213-000 . 9107-9113-000 . 9107-9213-000 . 9108-1113-000 . 9108-1213-000 . 9108-9113-000 . 9108-9213-000 . 9109-1113-000 . 9109-1213-000 . 9109-9113-000 . 9109-9213-000 . 9114-1113-000 . 9114-9113-000 . 9117-1113-000 . 9117-9113-000 . 9118-1113-000 . 9118-9113-000 . 9124-1513-000 . 9124-9513-000 . 9126-1513-000 . 9126-9513-000 . 9130-1573-0XX . 9130-9573-0XX . 9131-1573-0XX . 9131-9573-0XX . 9133-1113-000 . 9133-1213-000 . 9133-9113-000 . 9133-9213-000 . 9139-1113-000 . 9139-1213-000 . 9139-9113-000 . 9139-9213-000 . 9144-9513-000 . 9144-9513-001 . 9145-9513-000 . 9145-9513-001 . 9146-9513-000 . 9146-9513-001 . 9147-9513-000 . Numbers ending with -0XX indicate connectors with various types on specified page. APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page . 11 . 11 . 18 . 18 . 18 . 18 . 18 . 18 . 18 . 18 . 18 . 18 . 18 . 18 . 25 . 25 . 25 . 25 . 21 . 21 . 21 . 21 . 21 . 21 . 20 . 20 . 20 . 20 . 13 . 13 . 15 . 15 . 28 . 28 . 28 . 28 . 28 . 28 . 28 . 28 . 34 . 37 . 33 . 36 . 35 . 38 . 35 Continued on next page www.aepconnectors.com * aepsales@aepconnectors.com 56 Index by Part Number P/N 9147-9513-001 . 9148-9513-000 . 9149-9513-000 . 9150-9513-000 . 9151-9513-000 . 9154-1513-000 . 9154-9513-000 . 9155-1113-000 . 9155-1213-000 . 9155-9113-000 . 9155-9213-000 . 9162-9513-000 . 9162-9513-001 . 9163-1113-000 . 9163-9113-000 . 9168-9513-000 . 9174-9513-000 . 9176-1113-000 . 9176-1213-000 . 9176-9113-000 . 9176-9213-000 . 9179-9513-000 . 9179-9513-001 . 9180-9513-000 . 9180-9513-001 . 9181-9513-000 . 920-55 . . . . . . 920-56 . . . . . . 920-69 . . . . . . 920-82 . . . . . . 920-92 . . . . . . 9201-1553-0XX 9201-9553-0XX 9202-1553-0XX . 9202-9553-0XX . 9204-1113-0XX . 9204-1213-0XX . 9204-9113-0XX . 9204-9213-0XX . 9208-1113-0XX . 9208-1213-0XX . 9208-9113-0XX . 9208-9213-0XX . 9230-1553-0XX . 9230-9553-0XX . 9231-1553-0XX . 9231-9553-0XX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page . 38 . 40 . 39 . 41 . 41 . 25 . 25 . 25 . 25 . 25 . 25 . 33 . 36 . 21 . 21 . 39 . 39 . 18 . 18 . 18 . 18 . 33 . 36 . 34 . 37 . 40 . 33 . 39 . 42 . 36 . 44 . . 8 . . 8 . 11 . 11 . 19 . 19 . 19 . 19 . 19 . 19 . 19 . 19 . 13 . 13 . 15 . 15 P/N 9243-1553-0XX 9243-9553-0XX 9244-9513-000 . 9244-9513-001 . 9245-9513-000 . 9245-9513-001 . 9246-9513-000 . 9246-9513-001 . 9247-9513-000 . 9247-9513-001 . 9248-9513-000 . 9249-9513-000 . 9250-9513-000 . 9251-9513-000 . 9262-9513-000 . 9262-9513-001 . 9268-9513-000 . 9274-9513-000 . 9279-9513-000 . 9279-9513-001 . 9280-9513-000 . 9280-9513-001 . 9281-9513-000 . 9301-1063-009 . 9301-1063-109 . 9301-7063-009 . 9301-7063-109 . 9304-1113-013 . 9304-1113-014 . 9304-9113-013 . 9304-9113-014 . 9307-1113-001 . 9307-1113-002 . 9307-9113-001 . 9307-9113-002 . 9308-1113-001 . 9308-1113-003 . 9308-9113-001 . 9308-9113-003 . 9344-9513-000 . 9344-9513-000 . 9344-9513-001 . 9345-9513-000 . 9345-9513-001 . 9346-9513-000 . 9346-9513-001 . 9347-9513-000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page . . 9 . . 9 . 34 . 37 . 33 . 36 . 35 . 38 . 35 . 38 . 40 . 39 . 41 . 41 . 33 . 36 . 39 . 39 . 33 . 36 . 34 . 37 . 40 . . 6 . . 6 . . 6 . . 6 . 22 . 22 . 22 . 22 . 22 . 22 . 22 . 22 . 22 . 22 . 22 . 22 . 34 . 39 . 37 . 33 . 36 . 35 . 38 . 35 P/N 9347-9513-001 9348-9513-000 9350-9513-000 9351-9513-000 9362-9513-000 9362-9513-001 9368-9513-000 9374-9513-000 9376-1113-001 9376-1113-002 9376-9113-001 9376-9113-002 9379-9513-000 9379-9513-001 9380-9513-000 9380-9513-001 9381-9513-000 9401-1083-010 9401-1083-109 9401-1083-210 9401-1583-010 9401-1583-109 9401-7083-010 9401-7083-109 9401-7083-210 9401-7583-010 9401-7583-109 9402-1083-009 9402-1083-010 9402-1583-009 9402-1583-010 9402-7083-009 9402-7083-010 9402-7583-009 9402-7583-010 9404-1113-000 9404-9113-000 9407-1113-000 9407-9113-000 9408-1113-000 9408-1113-002 9408-9113-000 9408-9113-002 9409-1113-000 9409-9113-000 9412-1113-000 9412-9113-000 Numbers ending with -0XX indicate connectors with various types on specified page. APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page . 38 . 40 . 41 . 41 . 33 . 36 . 39 . 39 . 22 . 22 . 22 . 22 . 33 . 36 . 34 . 37 . 40 . . 6 . . 6 . . 7 . . 6 . . 6 . . 6 . . 6 . . 7 . . 6 . . 6 . 10 . 10 . 10 . 10 . 10 . 10 . 10 . 10 . 17 . 17 . 17 . 17 . 17 . 17 . 17 . 17 . 24 . 24 . 26 . 26 Continued on next page www.aepconnectors.com * aepsales@aepconnectors.com 57 Index by Part Number P/N 9413-1113-000 9413-9113-000 9422-1113-000 9422-9113-000 9424-1513-000 9424-9513-000 9425-1513-000 9425-9513-000 9431-1083-009 9431-1083-010 9431-1583-009 9431-1583-010 9431-7083-009 9431-7083-010 9431-7583-009 9431-7583-010 9432-1113-000 9432-9113-000 9433-1113-000 9433-9113-000 9441-1083-009 9441-1083-010 9441-1583-009 9441-1583-010 9441-7083-009 9441-7083-010 9441-7583-009 9441-7583-010 9443-1563-009 9443-1563-010 9443-7563-009 9443-7563-010 9453-1083-009 9453-1083-010 9453-1583-009 9453-1583-010 9453-7083-009 9453-7083-010 9453-7583-009 9453-7583-010 9454-1513-000 9454-9513-000 9455-1113-000 9455-9113-000 9456-1113-002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page . 27 . 27 . 26 . 26 . 20 . 20 . 20 . 20 . 14 . 14 . 14 . 14 . 14 . 14 . 14 . 14 . 26 . 26 . 28 . 28 . 14 . 14 . 14 . 14 . 14 . 14 . 14 . 14 . . 7 . . 7 . . 7 . . 7 . 12 . 12 . 12 . 12 . 12 . 12 . 12 . 12 . 24 . 24 . 24 . 24 . 27 P/N 9456-9113-002 9476-1113-000 9476-9113-000 9501-1593-009 9501-1593-010 9501-9593-009 9501-9593-010 9502-1593-009 9502-1593-010 9502-9593-009 9502-9593-010 9504-9113-009 9504-9113-031 9504-9113-034 9504-9113-035 9507-9113-003 9507-9113-004 9507-9113-005 9507-9113-006 9508-9113-001 9508-9113-002 9508-9113-003 9508-9113-011 9513-9113-008 9513-9113-009 9513-9113-012 9513-9113-013 9530-1593-009 9530-1593-010 9530-9593-009 9530-9593-010 9533-9113-001 9533-9113-002 9533-9113-003 9533-9113-004 9543-1593-009 9543-1593-010 9543-9593-009 9543-9593-010 9576-9113-001 9576-9113-002 9576-9113-003 9576-9113-004 9609-1513-000 9609-9513-000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page . 27 . 17 . 17 . . 7 . . 7 . . 7 . . 7 . . 7 . . 7 . . 7 . . 7 . 44 . 42 . 42 . 44 . 42 . 42 . 44 . 44 . 45 . 43 . 43 . 45 . 45 . 43 . 43 . 45 . 12 . 12 . 12 . 12 . 45 . 43 . 43 . 45 . . 7 . . 7 . . 7 . . 7 . 42 . 42 . 44 . 44 . 26 . 26 P/N 9610-1213-0XX . 9610-9213-0XX . 9613-1523-0XX . 9613-1563-009 . 9613-1563-010 . 9613-7563-009 . 9613-7563-010 . 9613-9523-0XX . 9620-9003-151 . 9646-1513-000 . 9647-1513-000 . 9649-1113-000 . 9650-1113-000 . TA - 0 0 0 7 . . . . . TA - 0 0 7 1 . . . . . TA - 0 1 0 5 . . . . . TA - 0 1 9 0 . . . . . TA - 0 2 3 4 . . . . . TA - 0 3 9 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page . 30 . 30 . 13 . 12 . 12 . 12 . 12 . 13 . 48 . 29 . 29 . 29 . 29 . 55 . 55 . 55 . 55 . 55 . 55 Numbers ending with -0XX indicate connectors with various types on specified page. APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 58 About Applied Engineering Products Since our foundation in 1973, we have always believed that having our customers take a look "inside AEP" is important in fostering strong vendor/customer relationships. We are proud of our physical plant and equipment, but even more so of our dedicated staff. When customers see first-hand how AEP's people keep a constant focus on maintaining and improving customer service and satisfaction, the reason for our consistently strong on-time delivery and quality records becomes clear. We invite you to see for yourself. Call us to arrange a plant tour--or, if you can't make a visit, ask for your copy of INSIDE AEP, our facilities and capabilities brochure. APPLIED ENGINEERING PRODUCTS (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * aepsales@aepconnectors.com 59 The SMA connectors in this brochure are only part of our complete line of subminiature and microminiature coaxial connectors and cable assemblies, including: * SMA * SMB * SMC * SSMB * SSMC * SLB (Slide-on version of SMB) * SSLB (Slide-on version of SSMB) * 75 Snap-on mating * 75 Screw-on mating * Adapters within and between series * Flexible cable assemblies * Semi-rigid cable assemblies * And over 100 styles of MIL-PRF-39012 QPL connectors in series SMA, SMB, and SMC Call for your copy of our 184-page full catalog to see them all. APPLIED ENGINEERING PRODUCTS 104 John W. Murphy Drive * P.O. Box 510 * New Haven, CT 06513 (203) 776-2813 * FAX (203) 776-8294 www.aepconnectors.com * e-mail: aepsales@aepconnectors.com 60