cui.com
date 12/09/2020 │ page 2 of 5CUI Inc │ SERIES: SWI3-E │ DESCRIPTION: AC-DC POWER SUPPLY
INPUT
parameter conditions/description min typ max units
voltage 90 264 Vac
frequency 47 63 Hz
current at nominal input voltage 0.2 A
leakage current at nominal input voltage & frequency 0.25 mA
no load power consumption at 115/230 Vac, 60/50 Hz 0.075 W
OUTPUT
parameter conditions/description min typ max units
line regulation 4.9 5.4 Vdc
load regulation 4.9 5.4 Vdc
start-up time at 115 Vac 3 s
PROTECTIONS
parameter conditions/description min typ max units
over current protection auto recovery 1 A
short circuit protection
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage input to output at 10 mA for 1 minute 3,000
4,242
Vac
Vdc
safety approvals GS (EN 62368)
EMI/EMC CE (EN 55032, CISPR 32, EN 61000-3-2, EN
61000-3-3, EN 55024, CISPR 24)
MTBF as per Telcordia SR-332 (Issue 2), at 115/230 Vac,
full load, 0°C~40°C 50,000 hours
RoHS 2011/65/EU
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature 0 40 °C
storage temperature -20 60 °C
operating humidity non-condensing 20 85 %
storage humidity non-condensing 5 95 %
Additional Resources: Product Page | 3D Model