TAMURA CORPORATION
43352 Business Park Drive. | P.O. Box 892230 Temecula, CA 92589-2230 | www.tamuracorp.com
87
Current Sense Transformers
USA
Tel: 800-872-6624
Fax: 909-676-9482
Japan
Tel: 81 (0)3 3978-2111
Fax: 81 (0)3 3923-0230
United Kingdom
Tel: 44 (0) 1380 731 700
Fax: 44 (0) 1380 731 702
Hong Kong
Tel: 852-2389-4321
Fax: 852-2341-9689
Up to 6 Amp Primary Current for High Frequency Applications
Surface mount and low profile design.
Pick and place compatible.
Designed to operate at 250kHz and above.
Hipot 500Vrms between primary and secondary.
Operating temperature: -40˚C to +85˚C.
www.tamuracorp.com
Current Sense Products
Specifications Measured at 25˚C
Package & Weight Information
CALL CALL
QTY/Tape & Reel Weight/each(g)
TCS-01 1:20 80 6 0.55 20
TCS-02 1:30 180 6 0.87 30
TCS-03 1:40 320 6 1.14 40
TCS-04 1:50 500 6 1.50 50
TCS-05 1:60 720 6 1.75 60
TCS-06 1:70 980 6 4.75 70
TCS-07 1:100 2000 6 5.90 100
TCS-08 1:125 3000 6 7.70 125
Part # Turns Ration
Pri:Sec
DCR
Inductance (µH) MIN
@ 10kHz, 0.1V Secondary Primary mMAX Secondary mMAX
Terminating Resistor () MAX
Secondary
1AboveTerminating Resistor Calculation based on 1 Volt/Ampere
2 To calculate terminating resistor (RL)
RL= (V*N)/I
Where V - Output Voltage
I - Input Current
N - Number of Secondary turns
Mechanical Dimensions
All dimensions are typical, please contact Tamura for tolerances and suggested layout information.