Midi Industrial Relay Type RMI. 2-10 10A Monostable * * * * * * * * * * * * High switching power Small size Wide range of application 12 A switching capacity (5 x 104 cycles) 2 poles configuration AC coils 6 to 230 VAC DC coils 5 to 110 VDC 3750 VAC dielectric coil to contacts Standard with LED, Push with arm and Flag IP 40 Conform to the CE low voltage directive IMQ, UL, TUV, CSA approved RMI. 2-10 10A Product Description Ordering Key The RMI relay (relay miniindustrial) can be used for a wide range of industrial applications. Type Terminal version Contact code Rated coil voltage DC / AC Available in 2 change-over contact configuration. PCB, solder and plug-in terminals. Terminal version: RMI A 2-10 012 DC A = Soldering terminals B = PCB terminals Type Selection Contact configuration 2 change over contacts (DPDT {2-form C}) Contact rating Contact code 10 A 2-10 Coil Characteristics, DC At 20C At 40C Nominal voltage VDC Pick-up voltage VDC Drop-out voltage VDC 5 6 12 24 48 60 110 4.0 4.8 9.6 19.2 38.4 48.0 88.0 0.5 0.6 1.2 2.4 4.8 6.0 11.0 Pick-up voltage VDC Drop-out voltage VDC 4.3 5.2 10.32 20.7 41.5 51.8 95.0 0.5 0.6 1.3 2.6 5.1 6.5 11.8 Coil resistance 27.5 40.0 160.0 650.0 2600.0 11000.0 11000.0 10% 10% 10% 10% 15% 15% 15% Coil Characteristics, AC At 20C Nominal voltage VAC 6 12 24 48 115/120 230 At 40C Pick-up voltage VAC Drop-out voltage VAC Pick-up voltage VAC Drop-out voltage VAC 4.8 9.6 19.2 38.4 96.0 176.0 1.8 3.6 7.2 14.4 36.0 66.0 5.2 10.3 20.7 41.4 103.6 190.0 2.0 3.8 7.7 15.5 38.8 71.2 Coil resistance 40.0 160.0 650.0 2600.0 11000.0 11000.0 10% 10% 10% 15% 15% 15% Coil operating range: see diagram n 1 pag. 12 10 Specifications are subject to change without notice Midi Industrial Relay Type RMI. 2-10 10A Monostable Contact Characteristics Contact rating (with resistive load) UL rating Usually rating (1x105 ops) Max. rating (5x104 ops) Material Current Max. switching current 10 A - 250 VAC 10 A - 250 VAC/30VDC 1/3 HP at 240 VAC 10 A - 250 VAC / 30 VDC 12 A - 250 VAC / 30 VDC Silver alloy Min. applicable load Initial contact resistance Max. switch. voltage Max. switch. power Life Electrical life Mechanical life 100 mA at 5 VDC/12 VAC 50 m (at 1 A 6 VDC) 250 VAC / 30 VDC at 10 A 2500 VA / 300 W at 10 A 1x105 cycles (1800 ops/h) 1x107 cycles (18000 ops/h) Insulation according to EN61810-5 Rated insulation voltage Impulsive insulation voltage Pollution degree Overvoltage category 250 V 3.6 KV 2 III Shock resistance Funktional Destructive Humidity Termination Construction Weight 100 m/s2 /10 g 1000 m/s2 /100 g 35% to 95% PCB and AMP Dust cover ~ 37 g 10 A Insulation Test Voltage (1 min.) Between coil and contacts Between open contacts Contact/Contact Initial insulation resistance 3750 VAC Vr.m.s 750 VAC Vr.m.s 1250 VA Vr.m.s 1.000 M - 500 VAC General Data Nominal coil power Operating time (At nominal voltage) Release time (At nominal voltage) Ambient temperature Vibration resistance 0.9 W DC / 1.2 VA AC 25 ms max. 25 ms max. -55 C to +70 C 10 to 55 Hz 1.5 mm Dimensions Pin View RMI . 2-10 . . . RMI . 2-10 . . . 4.5 O 1.3 3.5 2.2 x 0.5 5.3 Soldering Terminals 1 x 0.5 36 21.5 28 16.8 13.2 6.3 4 PCB Terminals 6.4 12.7 Only for PCB terminals Wiring Diagram RMI . 2-10 . . . Specifications are subject to change without notice 13 A1 9 11 5 14 1 12 14 A2 12 41 8 44 4 42 11 Midi Industrial Relay Type RMI. 2-10 10A Monostable Diagrams 2.2 1 Coil Operating Range 2.0 UB / UN 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0 +20 +40 +60 +80 +100 Ambient temperature (C) Number of operations (X 104 ops) Number of operations (X 104 ops) 2 Electrical life 500 DC inductive load L 30 VDC -- = 7ms R AC inductive load 250 VAC COS = 0,4 100 50 10 500 AC resistive load 250 VAC 100 50 DC resistive load 30 VDC 10 0 0 0 1 2 3 4 0 Switching Current (A) 2 4 6 8 10 Switching Current (A) 300 3 Max. DC load breaking capacity DC voltage (VDC) 200 100 60 50 40 30 20 10 0.1 0.2 0.3 1 2 10 20 DC Current (A) Approvals U.S.A. 12 CANADA GERMANY ITALY Specifications are subject to change without notice