POWERLOCK Applications
Reliable connections for field
installable power distribution
systems such as mobile generators.
Industrial power distribution boxes are
often equipped with Powerlock connectors.
The Veam POWERLOCK connector series for field installable power distribution systems offers the ultimate in
safety and reliability under the most severe operating conditions.
POWERLOCK is available in four standard formats which allow complete hook up through the standard daisy
chain principle. There are two Source connectors, one for panel mounting and one for cable attachment. These
are identified as Panel Source and Line Source. The other two types are Drain connectors. These connectors
are identified as Panel Drain and Line Drain.
Typical applications for POWERLOCK include three phase motors, generators, load banks, lighting distribution
panels and in-house supplies. POWERLOCK connectors serve a very diverse industry base which includes
outdoor concerts, carnivals, sporting events, television outdoor broadcast, theatres, electricity supply companies
and many heavy industrial environments such as construction.
The ITT “Engineered Blocks” symbol and the composite ITT INDUSTRIES
logo are registered trademarks of ITT Industries. © 2006
www.ittcannon.com/powerlock
3
www.ittcannon.com/powerlock
POWERLOCK Applications
We offer a wide variety of devices
for electricity supply companies.
Fuse carriers with integrated
Powerlock connectors provide a safe
and efficient connection to a power
distribution board.
Insulated rotary clamps provide
a compact connection to a
slotted busbar.
Insulated G-Style clamps for direct
connection to a live low voltage busbar.
4
In addition to our POWERLOCK series, we also
offer these connectivity solutions:
VSC
Heavy duty ribbed
coupling ring.
Extended female
ground contacts for
first mate, last break.
Threaded circular 19-
pin connector with
replaceable crimp or
solder contacts.
Harsh environments
Entertainment & Lighting
TOURLOCK
Intermateable connectors with CIR-LK series,
higher resistance to the physical shocks and
tearings. IP67 protection.
CIR-LK
Quick coupling and uncoupling.
High impact heavy duty coupling
mechanism. Bayonet connector for
audio applications, 4 to 53 channels.
CA-Bayonet
Signal and power connectors with exceptional
sealing against the ingress of fluids and will
withstand the effects of high vibrations.
APD
In-line and bulkhead connectors resistant
to harsh environmental conditions
(contaminants, vibration and shock).
Audio
5
www.ittcannon.com/powerlock
Table of Contents
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Additional ITT Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Powerlock Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-10
Powerlock Finger Test & Secondary Lock Assembly Instructions . . . . . . .11
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Special Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Insulator Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14-15
Snaplock Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16-18
NRG Sequential Mating System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Powerlock NRG Cabinet Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Insulated G Style Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
- Short Length Extension Arm
- Long Extension Arm
- Right Angle Extension Arm
Insulated Horizontal Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
- Short Length Extension Arm
- Long Extension Arm
- Right Angle Extension Arm
Insulated Dual G Style Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Rotary Clamp / Generator Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Insulated Overhead Line Clamp / Generator Connector . . . . . . . . . . . . .24
Insulated T-Piece Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Insulated Underground Cable Generator Connector . . . . . . . . . . . . . . . .25
Fault Re-energising Fuse Way Connector . . . . . . . . . . . . . . . . . . . . . . . .25
JW4ST Fuse Carrier with Integral Generator Input . . . . . . . . . . . . . . . . . .26
JW4ST82 Fuse Carrier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Cable Multi-Converter Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Screw In End Cap Fuse / Pole Mounted . . . . . . . . . . . . . . . . . . . . . . . . . .27
Fully Inserted Cable Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Powerlock Application Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Product Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
6
www.ittcannon.com/powerlock
Product Overview
Number of Contacts 1 1
Max. Current Rating 660A 250A
AWG 4 - 6/0 4 - 0/0
Contact Termination 25-300mm225-70mm2
Contact Type Crimp, set screw Crimp, threaded post M12
Threaded post M12
Contact Retention Systems Nylon pin Retention clip
Contact Extraction System Nylon pin Extraction tool
Mating Method Bayonet Bayonet
Operating Voltage 1000Vac 415Vac
Signal / Power Layouts Power only Power only
Operating Temperature -30 to 125C˚ -30 to 125C˚
-22 to 257F˚ -22 to 257F˚
Environmental Resistance up to IP67 up to IP67
Sealing when mated when mated
Protection against electric shock IP2X IP2X (male connectors only)
Mating Cycle 500 500
Shell Material Finish High temperature High temperature
thermoplastic thermoplastic
Flammability UL94-V0 UL94-V0
Shell Color green, black, red green, black, red
blue, yellow, brown blue, yellow, brown
grey, white grey, white
NRG Box - sequential mating
system for Powerlock
connectors, comes in a 19”
rack
Powerlock MultiConverter - to
convert lugged cable to Powerlock
Insulated Underground Cable
Connector - to convert solid alloy
cable cores to Powerlock
Insulated G-Style Clamps - for
direct connection to a live low
voltage busbar. Long and right
angle extension arms available
Insulated Horizontal Clamps -
for direct connection to a live low
voltage busbar. Long and right
angle extension arms available
Rotary Clamp - to provide a
compact connection to a slotted
busbar
Insulated Overhead Line Clamp
/ Generator Connectors - to
connect directly to low voltage
overhead line system
Insulated T-Piece Connector - to
split or to combine phases by the
quickest and safest possible
means
Fuse Carrier with Integrated
Generator Input Connector - to
provide a safe and efficient connection
to a power distribution board
Screw In End Cap Fuse / Pole
Mounted - to allow for direct
connection of a generator cable to a
pole mounted fuse unit.
Insulated Dual G Style Clamp -
for direct connection of 2 cables to
a live low voltage busbar
POWERLOCK SNAPLOCK
POWERLOCK Order Codes
www.ittcannon.com/powerlock
Harmonised Colour Coding
On March 31st 2004, the IEE published Amendment No. 2 to BS7671:2001 (the IEE Wiring Regulations). This amendment specifies
new cable core colours for electrical installations in the UK. These colours harmonise Europe to one specification for colour coding.
Electrical installation work commencing after March 31st 2004 may use the new harmonised colours or the pre-existing colours, but
not both. Work commencing on site after March 31st 2006 will be required to comply with the harmonised cable core colours and
must not use the old colours.
The new Harmonised Colours are as follows:
To comply with these new regulations we have a
wide range of insulator kits available. See page 14 for more information. These will enable you to replace the powerlock insulator
with the new Harmonised Colour version while retaining the original contact assembly.
7
Accessories
Reduction sleeves are used with the standard double set screw 120mm2contacts to facilitate smaller
cable cross sections. The sleeves are telescopic and are used in conjunction with each other.
Reduction sleeve kits are also available.
ITT Part Number
LL0023N Secondary Locking Release Key AN389900010
R95 Reduction Sleeve A3099000100
R95 -R70 Reduction Sleeve Kit A00602825
R95 to R50 Reduction Sleeve Kit A00602831
R95 to R35 Reduction Sleeve Kit A00602840
R95 to R25 Reduction Sleeve Kit A00602830
PCLD-5-M40A/S Protective cap for Line Drain plug with M40A or M40S gland 024-7592-000
PCLD-6-M40B Protective cap for Line Drain plug with M40B gland 024-7592-100
PCLS-5-M40A/S Protective cap for Line Source plug with M40A or M40S gland 024-7593-000
PCLS-5-M40B Protective cap for Line Source plug with M40B gland 024-7593-100
PCPS-5-M40A/S Protective cap for Panel Source receptacle AN0800150
PCPD-5-M40A/S Protective cap for Panel Drain receptacle AN0800160
Environmental locking cap for Line Drain with M40A or M40S gland PCS-NLD-*-**-M40A/S
Environmental locking cap for Line Source with M40A or M40S gland PCS-NLS-*-**-M40A/S
Environmental locking cap for Line Drain with M40B gland PCS-NLD-*-**-M40B
Environmental locking cap for Line Source with M40B gland PCS-NLS-*-**-M40B
Environmental locking cap for Panel Source PCS-NPS-*-**
Environmental locking cap for Panel Drain PCS-NPD-*-**
*-** specify the phase and color (E-GN, N-BL, 1-BN, 2-BK or 3-GY)
Example:
NLDFT-1-BK-L-C240-M40A
8
www.ittcannon.com/powerlock
There are two Line Source connectors for cable attachment, normally referred to as
a 400A and 660A version. Both are supplied with a male contact incorporating a
rigid IP2X finger proof nose, a slot for the secondary locking pin and a cable gland.
The contacts are secured in the housing by using a nylon cotter pin.
The 400A version has a set screw termination where two threaded set screws are
tightened to compress a reduction sleeve which has been fitted to the conductor
stranding. The set screw contact is normally used in combination with 120mm2
cable. Smaller cable sections can be terminated by selecting the appropriate
reduction sleeves and sliding them on in sequence over the exposed conductor
stranding. In combination with these sleeves set screw contacts can handle cables
from 25mm2to 120mm2.
The 660A version has a crimp termination for cable cross sections from 35 mm2to
300mm2cable. The 660A contact is normally used in combination with 240mm2
cable. It is essential to use the recommended crimp tool and die to ensure a
satisfactory crimp. Consult Customer Service for details on pull off loads and mV
drop values expected.
There are a wide range of cables used in the market to ensure that a
satisfactory result is obtained when POWERLOCK connectors are
terminated onto to the end of cables, the type and method needs to be
evaluated. For more details around termination, please refer to the
POWERLOCK Termination Guide which is available on
www.ittcannon.com.
The POWERLOCK Termination Guide provides guidelines on:
how to perform a crimped termination
what type of crimp tools and dies to use with recommendations
how to perform a set screw termination
terminating a threaded post panel type connector
typical test results obtained when terminating connectors onto a
range of cables
Line Source
400A, Earth Green
Line Source
660A, Earth Green
Line Source
Reliable connections for field installable
power distribution systems such as mobile
generators.
9
www.ittcannon.com/powerlock
Line Drain
Line Drain
400A, Earth Green
Line Drain
660A, Earth Green
There are two Line Drain connectors for cable attachment, normally referred to as a 400A and 660A version. Both are
supplied with a female contact incorporating a rigid IP2X spring loaded finger proof nose, an O-ring and a cable gland to
guarantee the IP67 rating when the connectors are mated.
The insulator is fitted with a spring loaded secondary locking pin which engages
when insulators are mated, preventing unintentional uncoupling through cable
torsion or inquisitive hands. The locking pin is disengaged by means of a remote
secondary locking release key.
The contacts are secured in the housing by using a nylon cotter pin.
10
www.ittcannon.com/powerlock
Panel Source & Panel Drain
Panel Source
400A, Earth Green Panel Drain
400A, Earth Green
There are four connectors for panel mounting, a Panel Source and Panel Drain in both 400A and 660A version.
The Panel Source connectors are supplied with a male contact incorporating a rigid IP2X finger proof
nose and a slot for the secondary locking pin. The Panel Drain connectors are supplied
with a female contact incorporating a rigid IP2X spring loaded finger proof nose
and an O-ring to guarantee the IP67 rating when the connectors are mated.
The insulator is fitted with a spring loaded secondary locking pin which engages
when the insulators are mated, preventing unintentional uncoupling through cable
torsion or inquisitive hands. The locking pin is disengaged by means of a remote
secondary locking release key.
Panel receptacles are supplied fully assembled with contacts. An M12 nut and spring washer are also supplied
loosely fitting onto the contact. Termination to the panel connector is made by fitting the cable lug or other
accessory using the nut and washer.
For further details on cable termination, please refer to the POWERLOCK Termination Guide.
Powerlock Termination Guide is available on www.ittcannon.com.
Industrial power distribution boxes are often
equipped with Powerlock panel connectors.
11
www.ittcannon.com/powerlock
Powerlock Finger Test and Secondary Lock Assembly Instructions
Secondary Locking Release Key
The Secondary Locking Release Key is used to push the secondary locking pin back, which then enables the
connectors to be rotated and uncoupled. The visuals below show the sequence for using the key for unmating
the connectors.
Secondary Locking Release Key
Secondary locking pin in locked position
Locked condition
1. Push key in this direction
2. Key tab fitted into slot in the insulator
3. Slot in insulator
4. Secondary locking pin
Key fitted into slot in insulator
Key fitted into slot, which depresses pin
Key fully fitted
Connector rotated to unlatch
Connector rotated
Connectors unlatched and key removed
Connector unmated
SQ
57.00
ø
42.65
12.70
24.60
31.00
38.00
ø
43.71
68.30
59.30
ø
46.90
12.70
24.60
31.00
68.30
ø
37.84
11.25
SQ
57.00
180.00 (M40S and M40A)
190.00 (M40B)
160.00 (M40S and M40A)
170.00 (M40B)
52.50 (M40S and M40A)
60.00 (M40B)
12
www.ittcannon.com/powerlock
Technical Data
120mm2Set Screw 300mm2Crimp
Maximum current rating: 400A 660A
Maximum rated voltage to earth: 2KVac / 3KVdc 2KVac / 3KVdc
Minimum flashover: 9.5K Vdc or Ac peak 9.5K Vdc or Ac peak
Operating temperature range: -30˚C to +125˚C -30˚C to +125˚C
Insulation resistance: >5 M ohms @500Vdc >5 M ohms @500Vdc
Ingress protection (mated): IP67 IP67
Protection against electrical shock: IP2X IP2X
Flammability: UL94-V0 UL94-V0
PANEL CUT-OUT DIMENSIONS
CONNECTOR DIMENSIONS
Panel Drain Line Source
Panel Source Line Drain
4 HOLES ø 5.50mm 4 HOLES ø 5.50mm
42.50 42.50
42.50
42.50
44.00
47.00
Cut-out for Panel Source Cut-out for Panel Drain
13
www.ittcannon.com/powerlock
Special Products
Powerlock Lug Connector
These devices allow for the conversion of Powerlock plug and socket system
to a standard nut and bolt fixing.
The units are simply connected to the Powerlock line connectors and locked
to avoid accidental disconnection.
Twin Busbar Adaptor
The twin busbar adaptor allows the user to connect two 660A Powerlock connectors
to a single connection point on a low voltage busbar.
DIN Fuse Carrier Adaptor
This fuse carrier adaptor was developed to provide a safe and
efficient Powerlock connection to DIN fuse carrier racks which
are mounted on most of the European power distribution
boards. There are Full Blade and Half Blade versions
available which gives the user an option to select what side
needs to be fed.
Sliding Collar Design
This new design eliminates the need for separate secondary locking key while still
having a secondary locking protection. A patented sliding collar mechanism
permanently fitted on the Line Source or Panel Source connector compresses the
spring loaded secondary locking pin and releases the connector.
Receptacle with Backshell
Powerlock receptacles are also available with backshells instead of threaded post
termination. The backshell offers the possibility to have a sealed IP67 termination
on the back of the receptacle.
14
www.ittcannon.com/powerlock
Insulator Kit
NLD-1-BN (brown) 320-7720-031
Insulator Kit
NLD-2-BK (black) 320-7720-032
Insulator Kit
NLD-3-GY (grey) 320-7720-033
Insulator Kit
NLD-N-BL (blue) 320-7720-030
Insulator Kit
NLD-E-GN (green) 320-7720-034
Description
L2
L3
N
E
L1
Insulator Kit
NLS-1-BN (brown) 320-7721-031
Insulator Kit
NLS-2-BK (black) 320-7721-032
Insulator Kit
NLS-3-GY (grey) 320-7721-033
Insulator Kit
NLS-N-BL (blue) 320-7721-030
Insulator Kit
NLS-E-GN (green) 320-7721-034
Description
L2
L3
N
E
L1
Insulator Kit
NPD-1-BN (brown) 078214-7030 078214-7060
Insulator Kit
NPD-2-BK (black) 078214-7031 078214-7061
Insulator Kit
NPD-3-GY (grey) 078214-7034 078214-7064
Insulator Kit
NPD-N-BL (blue) 078214-7033 078214-7063
Insulator Kit
NPD-E-GN (green) 078214-7035 078214-7065
Description 400A 660A
L2
L3
N
E
L1
LINE DRAIN
Line Drain insulator kit consists of a marked and labelled insulator, O-ring on the nose, secondary locking pin, and
nylon pin. M40 cable glands are ordered separately.
Powerlock Insulator Kits
LINE SOURCE
Line Source insulator kit consists of a marked and labelled insulator and nylon pin. M40 cable glands are ordered
separately.
PANEL DRAIN
Panel Drain insulator kit consists of a marked and labelled insulator, O-ring on the nose, secondary locking pin and
nylon pin.
NOTE: Insulator kits are used to convert old UK colour coded powerlock connectors to new harmonised colours as
explained on page 7.
400A or 660A Kit Cable Glands
400A or 660A Kit Cable Glands
M40S 15-23mm
368-7514-000
or
M40A 19-28mm
368-7514-001
or
M40B 22-32mm
368-7514-002
M40S 15-23mm
368-7514-000
or
M40A 19-28mm
368-7514-001
or
M40B 22-32mm
368-7514-002
15
www.ittcannon.com/powerlock
Insulator Kit
NPS-1-BN (brown) 078214-7020 078214-7010
Insulator Kit
NPS-2-BK (black) 078214-7021 078214-7011
Insulator Kit
NPS-3-GY (grey) 078214-7024 078214-7014
Insulator Kit
NPS-N-BL (blue) 078214-7023 078214-7013
Insulator Kit
NPS-E-GN (green) 078214-7025 078214-7015
Description 400A 660A
L2
L3
N
E
L1
Description Order Code
Panel Drain Insulator for use with Application Device Clamps
Panel Drain insulator kit for use with Application Device Clamps consist of a marked and labelled insulator, O-ring on
the nose, secondary locking pin and a nylon pin.
Insulator Kit
NPDFT-1-BN-L-T6-NF 078214-7050
Insulator Kit
NPDFT-2-BK-L-T6-NF 078214-7051
Insulator Kit
NPDFT-3-GY-L-T6-NF 078214-7054
Insulator Kit
NPDFT-N-BL-L-T6-NF 078214-7053
L2
L3
N
L1
Description Order Code
Panel Source Insulator for use with Application Device Clamps
Panel Source Insulator for use with Application Device Clamps consist of a marked and labelled insulator and a
nylon pin.
Insulator Kit
NPS-1-BN-T6-NF 078214-7040
Insulator Kit
NPS-2-BK-T6-NF 078214-7041
Insulator Kit
NPS-3-GY-T6-NF 078214-7044
Insulator Kit
NPS-N-BL-T6-NF 078214-7043
L2
L3
N
L1
Powerlock Insulator Kits
PANEL SOURCE
Panel Source insulator kit consists of a marked and labelled insulator and a nylon pin.
Description Order Code
Insulators for use with JW4ST & JW4ST82 Fuse Carriers
(cotter pin is ordered as a separate part)
Insulator Kit
LVD400/401-1-BN 135-7501-000
Insulator Kit
LVD400/401-2-BK 135-7501-001
Insulator Kit
LVD400/401-3-GY 135-7501-002
Insulator Kit
LVD400/401-N-BL 135-7501-003
L2
L3
N
L1
cotter pin for above A3299000100
NOTE:
To exchange insulators on application
devices, please contact your local
sales office for instructions.
16
www.ittcannon.com/powerlock
The Snaplock connector series is a miniature power cable hook up system offering high current capability while
maintaining minimal physical dimensions.
Snaplock offers a commercially viable option to historical hard wiring techniques. In addition, Snaplock offers
improved safety characteristics through utilization of insulated bodies, sealing mechanisms, locking
mechanisms and protected current carrying elements.
The speed of connection and disconnection offers great savings in equipment down time, servicing and
maintenance procedures. The security of the connection is maintained by a simple but very effective locking
mechanism which can be utilized as a temporary or permanent lock.
The contact elements are based on our proven multi-lam band technology which ensures low contact
resistance thus minimizing power loss, low physical insertion forces with a self wiping action, and high number
of mating cycles. The male contact elements are protected by a non-conductive tip which makes physical
contact with the current carrying element impossible.
The contacts are held in the insulators via a clip retention system. This allows for fast, simple assembly and
good retention of the contact sets, especially where vibration is an environmental concern. Contact termination
to the cable conductor is by standard compression crimp or threaded M12 post (panel connectors).
Connectors for panel mounting and cable mounting are available. All connectors are IP67 sealed when mated
through utilization of integral sealing rings and cable strain relief.
Snaplock Connector Series
TECHNICAL DATA
Rated voltage: 415Vac
Rated current: 250A continuous
400A 1 sec peak
(dependant on cable CSA used)
Ingress protection: IP67 when mated
Operating temperature range: -30˚C to +125˚C
Protecting against electric shock: IP2X (male connectors)
Flammability: UL94-V0
17
www.ittcannon.com/powerlock
Snaplock Order Code
Example: SNLM-P-C35-25L-BK
18
www.ittcannon.com/powerlock
Snaplock Connector Series
4 HOLES ø 5.00mm
Cutout for Panel Connectors
ø
33.50
30.00
30.00
PAN EL MALE
PAN EL FEMALE
CABLE MALE
CABLE FEMALE
26.00
48.00
27.00
5.00
ø
33.00
5.00
ø
33.00
27.00
18.00
47.00
26.00
106.00
76.50
186.00
OVERALL ASSEMBLED LENGTH
PANEL CUT-OUT DIMENSIONS
CONNECTOR DIMENSIONS
19
www.ittcannon.com/powerlock
The NRG Sequential mating system comes in a 19” rack format and guarantees the proper sequence of mating
and un-mating a set of POWERLOCK connectors.
The patented cam operated covers on each of the panel connectors ensure that the correct sequence of
Ground, Neutral, Phase 1, Phase 2 and Phase 3 is adhered too.
Once connected, the system can be locked by a key to prevent un-mating of the system by unauthorized
people. For further safety, the unit also features a micro-switch connection on the keylock that can be hooked
up to a circuit breaker. When the keylock is disabled the circuit breaker will trip and isolate the panel from the
main power, thus preventing the disconnection of the unit while under load.
A primary keylock can also be used when the system is idle to prevent unauthorized connection of the power
cables.
With two current rating options of 400A and 600A, the NRG box is available as either a Panel Source or Panel
Drain unit, each having an IP65 rating when mated. The NRG system is completely compatible and
intermateable with all original POWERLOCK connectors. European, USA, UK and Australian colour code
versions are available.
NRG Sequential Mating System
NRG Box 3 Phase, Neutral and Earth for connection
with 400A Line Drain Connectors NRG-5-PS-E-400 A00045006
NRG Box 3 Phase, Neutral and Earth for connection
with 400A Line Source Connectors NRG-5-PD-E-400 A00045007
NRG Box 3 Phase, Neutral and Earth for connection
with 660A Line Drain Connectors NRG-5-PS-E-600 A00045008
NRG Box 3 Phase, Neutral and Earth for connection
with 660A Line Source Connectors NRG-5-PD-E-600 A00045009
Description Description Code ITT Part Number
Mechanical Safety
Plug connectors locked
when underload.
Electrical Safety
Connectors / Switch for
remote control.
20
www.ittcannon.com/powerlock
The Powerlock Power Distribution Cabinet has been designed and tested to conform to the requirements for
CE marking by implementing the requirements of the Low Voltage Directive (LVD) 73/23/EEC which is
implemented as the Electrical Equipment (Safety) Regulations 1994.
It complies with the following specifications:
BS EN 60439-1:1999, BS EN 60439-5:1996 and IEC 60529:1992
The cabinet is fitted with either 1 or 2 NRG sequential units rated at 400A or 600A. These units allow safe
connection in the correct sequence of Powerlock connectors (Ground, Neutral, Phase 1, Phase 2, Phase 3).
The unit incorporates a key lockable switch which can be connected to auxiliary safety circuits. Once locked, it
prevents unmating of the system by unauthorized personnel.
The cabinet is fitted with external access and blanking panels which are designed to aid in the routing of cables
both into and out of of the cabinet. An information plate is fitted onto the side of the cabinet incorporating data
for traceability. The cabinet door incorporates 2 door locks (triangular key type) for security. When latched, the
cabinet has an IP34D environmental rating. For additional security, a padlock can also be fitted. Fixing plates
are provided to enable the unit to be be securely fixed during installation, prior to electrical operation.
The cabinet is fitted with generic safety signs. These signs give warning of the potential electrical hazard,
together with mandatory signs regarding cabinet security and isolation. All signs supplied conform to the
current requirements of the Health and Safety (Safety Signs and Signals) Regulations.
Part Number Structure
078214-XXXX
0= NRG fitted with Panel Source Connector
1= NRG fitted with Panel Drain Connector
0= No busbars fitted
1= Bottom cable entry, busbars fitted
2= Top cable entry, busbars fitted
4= 400A rating
6= 600A rating
1= NRG enclosure with 1x NRG box (UK colour code)
2= NRG enclosure with 2x NRG box (UK colour code)
3= NRG enclosure with 1x NRG box (EU colour code)
4= NRG enclosure with 2x NRG box (EU colour code)
Powerlock NRG Cabinet Assembly
21
www.ittcannon.com/powerlock
Completely insulated which allows for direct connection of a generator cable to a live low voltage busbar.
The clamp is fixed to the busbar by means of an insulated box spanner which meets the requirements of
IEC 60900 (live working, hand tools for use up to 1000Vac and 1500Vdc).
APOWERLOCK generator input connection point is incorporated within the clamp to allow for direct connection
of the generator cable end.
These devices are rated at 660A continuous. The clamps are also keyed to distinguish between phases and
prevent connection errors.
Insulated G Style Clamp
Insulated G Style Clamp,
Neutral Key Position / Blue LVB200-N-BL-S A00045S2N
Insulated G Style Clamp
Line 1 Key Position / Brown LVB200-1-BN-S A00045S21
Insulated G Style Clamp
Line 2 Key Position / Black LVB200-2-BK-S A00045S22
Insulated G Style Clamp
Line 3 Key Position / Grey LVB200-3-GY-S 078214-6000
Insulated Handle LVL200H A00044027
Short Length Extension Arm
Long Extension Arm
Insulated G Style Clamp,
Neutral Key Position / Blue LVB200-N-BL-E A00044E3N
Insulated G Style Clamp
Line 1 Key Position / Brown LVB200-1-BN-E A00044E31
Insulated G Style Clamp
Line 2 Key Position / Black LVB200-2-BK-E A00044E32
Insulated G Style Clamp
Line 3 Key Position / Grey LVB200-3-GY-E A00044E43
Insulated Handle LVL200H A00044027
Insulated G Style Clamp,
Neutral Key Position / Blue LVB200-N-BL-R 078214-6023
Insulated G Style Clamp
Line 1 Key Position / Brown LVB200-1-BN-R 078214-6020
Insulated G Style Clamp
Line 2 Key Position / Black LVB200-2-BK-R 078214-6021
Insulated G Style Clamp
Line 3 Key Position / Grey LVB200-3-GY-R 078214-6022
Insulated Handle LVL200H A00044027
Right Angle Extension Arm Description Description Code ITT Part Number
Description Description Code ITT Part Number
Description Description Code ITT Part Number
22
www.ittcannon.com/powerlock
Completely insulated which allows for direct connection of a generator cable to a live low voltage busbar.
The clamp is fixed to the busbar by means of an insulated box spanner which meets the requirements of
IEC 60900 (live working, hand tools for use up to 1000Vac and 1500Vdc).
A POWERLOCK generator input connection point is incorporated within the clamp to allow for direct
connection of the generator cable end.
These devices are rated at 660A continuous. The clamps are also keyed to distinguish between phases and
prevent connection errors.
Insulated Horizontal Clamp,
Neutral Key Position / Blue LVK600-N-BL-S 078214-6213
Insulated Horizontal Clamp
Line 1 Key Position / Brown LVK600-1-BN-S 078214-6210
Insulated Horizontal Clamp
Line 2 Key Position / Black LVK600-2-BK-S 078214-6211
Insulated Horizontal Clamp
Line 3 Key Position / Grey LVK600-3-GY-S 078214-6212
Insulated Handle LVK60LH A00044L8H
Short Length
Extension Arm
Description Description Code ITT Part Number
Insulated Horizontal Clamp,
Neutral Key Position / Blue LVK600-N-BL-E 078214-6203
Insulated Horizontal Clamp
Line 1 Key Position / Brown LVK600-1-BN-E 078214-6200
Insulated Horizontal Clamp
Line 2 Key Position / Black LVK600-2-BK-E 078214-6201
Insulated Horizontal Clamp
Line 3 Key Position / Grey LVK600-3-GY-E 078214-6202
Insulated Handle LVK60LH A00044L8H
Long Extension Arm Description Description Code ITT Part Number
Right Angled
Extension Arm
Insulated Horizontal Clamp,
Neutral Key Position / Blue LVK600-N-BL-R A00044R9N
Insulated Horizontal Clamp
Line 1 Key Position / Brown LVK600-1-BN-R A00044R91
Insulated Horizontal Clamp
Line 2 Key Position / Black LVK600-2-BK-R A00044R92
Insulated Horizontal Clamp
Line 3 Key Position / Grey LVK600-3-GY-R A00044R95
Insulated Handle LVK60LH A00044L8H
Description Description Code ITT Part Number
Insulated Horizontal Clamp
23
www.ittcannon.com/powerlock
Completely insulated which allows for direct connection of a generator cable to a live low voltage busbar.
The clamp is fixed to the busbar by means of an insulated box spanner which meets the requirements of
IEC 60900 (live working, hand tools for use up to 1000Vac and 1500Vdc).
A POWERLOCK generator input connection point is incorporated within the clamp to allow for direct connection of the
generator cable end.
These devices are rated at 660A continuous. The clamps are also keyed to distinguish between phases and prevent
connection errors.
Insulated Dual G Style Clamp
Insulated Dual G Style Clamp,
Neutral Key Position / Blue LVB1200-N-BL 078214-6113
Insulated Dual G Style Clamp
Line 1 Key Position / Brown LVB1200-1-BN 078214-6110
Insulated Dual G Style Clamp
Line 2 Key Position / Black LVB1200-2-BK 078214-6111
Insulated Dual G Style Clamp
Line 3 Key Position / Grey LVB1200-3-GY 078214-6112
Insulated Handle LVL200H A00044027
Compact unit incorporates a Line Source Finger Proof connector with a rotary type clamp, suitable for use on slotted
Bus-bars. The handle meets the requirements of IEC 60900 (live working, hand tools for use up to 1000Vac
and 1500Vdc).
The clamp is manufactured in high conductivity material and is suitable for 660A continuous operation.
The rotary wheel is manufactured from hardened steel which eliminates problems associated with hole elongation.
An ergonomic fully insulated handle is available for fixing the clamp to a slotted bus-bar.
Rotary Clamp / Generator Connector
Rotary Style Clamp,
Neutral Position / Color Coded and Keyed LVE500-N-BL 078214-6103
Rotary Style Clamp,
Line 1 Position / Color Coded and Keyed LVE500-1-BN 078214-6100
Rotary Style Clamp,
Line 2 Position / Color Coded and Keyed LVE500-2-BK 078214-6101
Rotary Style Clamp,
Line 3 Position / Color Coded and Keyed LVE500-3-GY 078214-6102
Insulated Handle LVE500H A00044054
Description Description Code ITT Part Number
Description Description Code ITT Part Number
24
www.ittcannon.com/powerlock
Insulated Overhead Line Clamp / Generator Connector
This device allows for direct connection of a generator unit to Low Voltage overhead line systems.
The unit consists of an insulated Line Clamp, 3 metres of 50mm2 flexible copper cable and a POWERLOCK
generator input cable.
The methods of connection is:
1. The copper or alloy overhead wire is cleaned to ensure good connection points.
2. The clamp is hooked onto the wire and tightened via the insulated clamp body.
3. The flexible cable is then strapped to the pole.
4. At the cable end, a POWERLOCK generator connection point is provided for connection of the generator cable.
The generator connection point offers all standard safety features associated with the POWERLOCK range,
such as keys to distinguish phases, IP67 sealing and individual phase color coding.
Insulated Overhead Line Clamp,
Neutral Key Position / Blue LVF600-N-BL 078214-6303
Insulated Overhead Line Clamp
Line 1 Key Position / Brown LVF600-1-BN 078214-6300
Insulated Overhead Line Clamp
Line 2 Key Position / Black LVF600-2-BK 078214-6301
Insulated Overhead Line Clamp
Line 3 Key Position / Grey LVF600-3-GY 078214-6302
Description Description Code ITT Part Number
The insulated T-Piece connector allows the user the option to split one phase into two or combine two phases
into one by the quickest and safest possible means.
The Input and Output connectors are color coded and mechanically keyed the same to prevent connection
errors.
All connectors are IPX2 rated when mated and come with the Secondary Locking as standard.
Insulated T-Piece Connector
Order Information
Position A (x1): Panel Drain Finger Proof (PDFT) or Panel Source (PS)
Position B (x2): Panel Drain Finger Proof (PDFT) or Panel Source (PS)
Phase: 1, 2, 3, N, E
Color: Red (R), Yellow (Y), Blue (BL), Black (BK), Green (GN)
Brown (BN), Grey (GY), White (W)
Amperage: 400 Amps (T4), 660 Amps (T6)
Version shown: APDFT-BPS-3-BL-T4
Position A
Position B
25
www.ittcannon.com/powerlock
The two way JP and JS carriers offer a safe and reliable means of connecting Fault Re-energising equipment to
feeder cabinet bus-bars.
These units consist of:
1. One outlet connector (RED), which is connected to the LV side of the fuse way. This is the supply to the
Fault Re-energising equipment.
2. One inlet connector (BLACK), which is connected to the outgoing Feeder side. This is the return from the
Fault Re-energising equipment.
3. A dummy isolating fuse ensures mechanical alignment of the wedge clamping system and electrical
separation of the LV and Feeder circuits.
These carriers are available in both JS (92mm) and JP (82mm) centers.
Fault Re-energising Fuse Way Connector
JP Carrier 82mm center LVD402-82 A00044241
JS Carrier 92mm center LVD402-92 A00044242
Description Description Code ITT Part Number
This compact unit incorporates a POWERLOCK generator input connection point with a rear termination area to
accept solid alloy cable cores.
This enables a temporary mobile generator to be connected to an underground cable when repair work is
undertaken.
The cable is excavated, cut and the POWERLOCK connector then fitted to the cable cores via 2 set screws. The
generator cable end can then directly link into the underground cable.
After completion of the repair, the POWERLOCK fittings are simply removed and the main cable spliced using
existing methods.
Insulated Underground Cable Generator Connector
Insulated Underground Cable Generator Connector
Neutral Key Postion/ Blue LVJ900-N-BL 078214-9033
Insulated Underground Cable Generator Connector
Line 1 Key Postion/ Brown LVJ900-1-BN 078214-9030
Insulated Underground Cable Generator Connector
Line 2 Key Postion/ Black LVJ900-2-BK 078214-9031
Insulated Underground Cable Generator Connector
Line 3 Key Postion/ Grey LVJ900-3-GY 078214-9032
Insulated Ratchet Tightening Tool LVJ900H A0004406H
Description Description Code ITT Part Number
26
www.ittcannon.com/powerlock
JW4ST Fuse Carrier with Integral Generator Input Connector
JW4ST82 Fuse Carrier with Integral Generator Input Connector
JW4ST82 (31/4 inch pitch) fuse carrier was developed to provide a safe and efficient means of connecting a mobile
generator supply cable to fully shrouded or non-shrouded distribution boards. The unit complies with the
requirements of EATS 37.2.
The unit accept standard BS88-5 fuses (not supplied).
The JW4ST82 fuse unit also offers the ability to make a direct connection to many pole mounted transformer
fuse units.
JW4ST82 fuse unit with integral generator connection point,
Neutral Key Postion/ Blue LVD401-N-BL 078214-9023
JW4ST82 fuse unit with integral generator connection point,
Line 1 Key Postion/ Brown LVD401-1-BN 078214-9020
JW4ST82 fuse unit with integral generator connection point,
Line 2 Key Postion/ Black LVD401-2-BK 078214-9021
JW4ST82 fuse unit with integral generator connection point,
Line 3 Key Postion/ Grey LVD401-3-GY 078214-9022
Description Description Code ITT Part Number
JW4ST (35/8 inch pitch) fuse carrier was developed to provide a safe and efficient means of connecting a mobile
generator supply cable to fully shrouded or non-shrouded distribution boards. The unit complies with the
requirements of EATS 37.2.
The generator cable (when fitted with POWERLOCK Line Drain cable coupler) can be plugged directly into
the Fuse Carrier and used to feed either the Low Voltage bus-bar or feeder circuit.
The fuse generator connector is finger proof to avoid accidental touching of live elements.
The input connectors are color coded and mechanically keyed to prevent connection errors. Line 1 units
will only accept a Line 1 generator connector.
The integral generator connector also accepts generator connectors with the patented secondary locking device
which eliminates the potential of accidental disconnection under load conditions.
Because this unit is direct replacement for the existing standard JW4ST fuse unit, it offers a safe, fast and cost
effective method of upgrading existing distribution boards to have generator input points. It is not
necessary to make any modifications to the cabinet other than remove an existing fuse way and replace
with the JW4ST system
JW4ST fuse unit with integral generator
connection point, Neutral Key Postion/Blue LVD400-N-BL 078214-9013
JW4ST fuse unit with integral generator
connection point, Line 1 Key Postion/Brown LVD400-1-BN 078214-9010
JW4ST fuse unit with integral generator
connection point, Line 2 Key Postion/Black LVD400-2-BK 078214-9011
JW4ST fuse unit with integral generator
connection point, Line 3 Key Postion/Grey LVD400-3-GY 078214-9012
Description Description Code ITT Part Number
27
www.ittcannon.com/powerlock
Cable Multi-Converter
The Multi-Converter enables any user to easily convert lugged cable to
POWERLOCK within minutes ensuring all safety and security of basic
POWERLOCK connector series. A POWERLOCK connection point is
incorporated within the unit to allow for direct connection of the generator
cable end.
Color coding appears on both POWERLOCK and main body of the
device for easy recognition of Phases to prevent connection
errors. Available in both Source and Drain formats, this device
assures the correct connection whether it be POWERLOCK or
Lug to maximize cable management.
Multi-Converter Source
Neutral, Blue 078214-9053
Multi-Converter Source
Earth, Green 078214-9055
Multi-Converter Source
Brown PH1 078214-9050
Multi-Converter Source
Black PH2 078214-9051
Multi-Converter Source
Grey PH3 078214-9052
SOURCE Part Code
Multi-Converter Drain
Neutral, Blue 078214-9063
Multi-Converter Drain
Earth, Green 078214-9065
Multi-Converter Drain
Brown PH1 078214-9060
Multi-Converter Drain
Black PH2 078214-9061
Multi-Converter Drain
Grey PH3 078214-9062
Multi-Converter Tightening Tool
for Source and Drain 274-7630-000
DRAIN Part Code
Screw In End Cap Fuse / Pole Mounted
This device allows for direct connection of a generator cable to a
200A transformer pole mounted fuse unit. The existing fuse unit is
unscrewed from the holder and replaced with the POWERLOCK
unit, which incorporates a dummy fuse to allow for the outgoing
circuit only. This enables the generator feed cable to be directly
plugged into the pole mounted unit in order to feed the overhead
Low Voltage transmission lines.
Screw in end cap fuse
Neutral Key Position / Blue LVC300-N-BL 078214-9043
Screw in end cap fuse
Line 1 Key Postion / Brown LVC300-1-BN 078214-9040
Screw in end cap fuse
Line 2 Key Postion / Black LVC300-2-BK 078214-9041
Screw in end cap fuse
Line 3 Key Postion / Grey LVC300-3-GY 078214-9042
Description Description Code ITT Part Number
28
www.ittcannon.com/powerlock
Fully Insulated Cable Support
The insulated cable support will handle 25mm2- 300mm2cables at LV pillar level, or higher to
accomodate substation LV boards and / or customer switchgear. The support is easily transportable due to
the removable base. It is fully insulated and complements our range of mobile generator accessories.
Insulated Cable Support LVCS100 078214-9910
Description Description Code ITT Part Number
29
www.ittcannon.com/powerlock
POWERLOCK Application Kits
Different variations available, please contact Customer Service
3 Phase and Neutral G-Clamp Kit
ITT Part # 078214-9900
3 Phase and Neutral
Underground Connector Kit
ITT Part # 078214-9903
3 Phase Rotary Clamp Kit
ITT Part # 078214-9901
3 Phase JP Fuse Carrier Kit - ITT Part # 078214-9905
JS Fuse Carrier Kit - ITT Part # 078214-9906
3 Phase and Neutral Overhead Line Kit
ITT Part # 078214-9904
3 Phase and Neutral Rotary Clamp Kit
ITT Part # 078214-9902
Consists of:
LVS200-1-BN
LVS200-2-BK
LVS200-3-GY
LVS200-N-BL
LVL200H
Watertight Protective Case
Consists of:
LVD400-1-BN LVD401-1-BN
LVD400-2-BK LVD401-2-BK
LVD400-3-GY LVD401-3-GY
(fuses available by request)
Watertight Protective Case
Consists of:
LVJ900-1-BN
LVJ900-2-BK
LVJ900-3-GY
LVJ900-N-BL
LVJ900H
Watertight Protective Case
Consists of:
LVF600-1-BN (3M)
LVF600-2-BK (3M)
LVF600-3-GY (3M)
LVF600-N-BL (3M)
Watertight Protective Case
Consists of:
LVE500-1-BN
LVE500-2-BK
LVE500-3-GY
LVE500H
Watertight Protective Case
Consists of:
LVE500-1-BN
LVE500-2-BK
LVE500-3-GY
LVE500-N-BL
LVE500H
Watertight Protective Case
30
www.ittcannon.com/powerlock
Electronic Components
Product Safety Information
THIS NOTE MUST BE READ IN CONJUNC-
TION WITH THE PRODUCT DATA
SHEET/CATALOG. FAILURE TO OBSERVE
THE ADVICE IN THIS INFORMATION
SHEET AND THE OPERATING CONDI-
TIONS SPECIFIED IN THE PRODUCT DATA
SHEET/ CATALOG COULD RESULT IN
HAZARDOUS SITUATIONS.
1. MATERIAL CONTENT AND PHYSICAL
FORM
Electrical connectors do not usually contain
hazardous materials. They contain conduct-
ing and non-conducting materials and can be
divided into two groups.
a) Printed circuit types and low cost audio
types which employ all plastic insulators and
casings.
b) Rugged, Fire Barrier and High Reliability
types with metal casings and either natural
rubber, synthetic rubber, plastic or glass insu-
lating materials. Contact materials vary with
type of connector and also application and
are usually manufactured from either:
Copper, copper alloys, nickel, alumel,
chromel or steel. In special applications, other
alloys may be specified.
2. FIRE CHARACTERISTICS AND ELECTRIC
SHOCK HAZARD
There is no fire hazard when the
connector is correctly wired and used within
the specified parameters. Incorrect wiring or
assembly of the connector or careless use of
metal tools or conductive fluids, or transit
damage to any of the component parts may
cause electric shock or burns. Live circuits
must not be broken by separating mated con-
nectors as this may cause arcing, ionization
and burning. Heat dissipation is greater at
maximum resistance in a circuit. Hot spots
may occur when resistance is raised locally
by damage, e.g. cracked or deformed con-
tacts, broken strands of wire. Local overheat-
ing may also result from the use of the incor-
rect application tools or from poor quality sol-
dering or slack screw terminals. Overheating
may occur if the ratings in the product Data
Sheet/Catalog are exceeded and can cause
breakdown of insulation and hence electric
shock. If heating is allowed to continue it
intensifies by further increasing the local
resistance through loss of temper of spring
contacts, formation of oxide film on contacts
and wires and leakage currents through car-
bonization of insulation and tracking paths.
Fire can then result in the presence of com-
bustible materials and this may release nox-
ious fumes. Overheating may not be visually
apparent. Burns may result from touching
overheated components.
3. HANDLING
Care must be taken to avoid damage
to any component parts of electrical connec-
tors during installation and use. Although
there are normally no sharp edges, care must
be taken when handling certain components
to avoid injury to
fingers. Electrical connectors may be dam-
aged in transit to the customers, and damage
may result in creation of
hazards. Products should therefore be exam-
ined prior to installation/use and rejected if
found to be damaged.
4. DISPOSAL
Incineration of certain materials may release
noxious or even toxic fumes.
5. APPLICATION
Connectors with exposed contacts should not
be selected for use on the current supply side
of an electrical circuit, because an electric
shock could result from touching exposed
contacts on an unmated connector. Voltages
in excess of 30 V ac or 42.5 V dc are poten-
tially
hazardous and care should be taken to
ensure that such voltages cannot be transmit-
ted in any way to exposed metal parts of the
connector body. The
connector and wiring should be checked,
before making live, to have no damage to
metal parts or insulators, no solder blobs,
loose strands, conducting lubricants, swarf,
or any other undesired conducting particles.
Circuit resistance and continuity check should
be made to make certain that there are no
high resistance joints or
spurious conducting paths. Always use the
correct application tools as specified in the
Data Sheet/Catalog. Do not permit untrained
personnel to wire, assemble or tamper with
connectors. For operation voltage please see
appropriate national regulations.
IMPORTANT GENERAL INFORMATION
(i) Air and creepage paths/Operating voltage.
The admissible operating voltages depend on
the individual applications and the valid
national and other applicable safety regula-
tions.
For this reason the air and creepage path
data are only reference values. Observe
reduction of air and creepage paths due to
PC board and/or harnessing.
(ii) Temperature
All information given are temperature limits.
The operation temperature depends on the
individual application.
(iii) Other important information
Cannon continuously endeavors to improve
their products. Therefore, Cannon products
may deviate from the description, technical
data and shape as shown in this catalog and
data sheets.
“Engineered for life” is a registered trademark
of ITT Industries, © 2005. All other trade-
marks or registered trademarks are property
of their respective owners. All data subject to
change without notice.
Product Warranty
ITT Industries, Cannon manufactures the
highest quality products available in the
marketplace; however these products are
intended to be used in accordance with the
specifications in this publication. Any use
or application that deviates from the stated
operating specifications is not recommend-
ed and may be unsafe. No information and
data contained in this publication shall be
construed to create any liability on the part
of Cannon. Any new issue of this publica-
tion shall automatically invalidate and
supersede any and all previous issues. A
limited warranty applies to Cannon prod-
ucts. Except for obligations assumed by
Cannon under this warranty, Cannon shall
not be liable for any loss, damage, cost of
repairs, incidental or consequential dam-
ages of any kind, whether or not based on
express or implied warranty, contract, neg-
ligence or strict liability arising in connec-
tion with the design, manufacture, sale,
use or repair of the products. Product avail-
ability, prices and delivery dates are exclu-
sively subject to our respective order con-
firmation form; the same applies to orders
based on development samples delivered.
This publication is not to be construed as
an offer. It is intended merely as an invita-
tion to make an offer. By this publication,
Cannon does not assume responsibility or
any liability for any patent infringements or
other rights of third parties which may
result from its use. Reprinting this publica-
tion is generally permitted, indicating the
source. However, Cannon's prior consent
must be obtained in all cases.