AC Line Filters SU Coils, SU 16VD High Frequency Type Overview Applications The KEMET SU Coils, SU 16VD High Frequency Type AC line filters are offered in a wide variety of sizes and specifications. * Consumer Electronics * Common mode choke Benefits * * * * Wide variety of sizes and specifications Inductances up to 50 H Rated Currents up to 4 A DC Resistances as low as 0.04 Part Number System SU 16 VD- 30 040 Series Core Size (mm) Core Orientation Rated Current (A) Minimum Inductance (H) SU 16 = 16.0 VD- = Vertical x0 = x.0 A (e.g., 30 = 3.0 A) 0xx = xx H (e.g., 040 = 40 H) One world. One KEMET (c) KEMET Electronics Corporation * P.O. Box 5928 * Greenville, SC 29606 * 864-963-6300 * www.kemet.com LF0021_SU16VD * 3/27/2017 1 AC Line Filters - SU Coils, SU 16VD High Frequency Type Dimensions - Millimeters 19 Maximum 10 27.5 Maximum 23 Maximum 130.5 4.0 Minimum o0.7 100.5 13 Environmental Compliance All KEMET AC Line Filters are RoHS Compliant. RoHS Compliant Table 1 - Ratings & Part Number Reference Part Number Rated Current AC (A) Inductance (H) Minimum DC Resistance/ Line () Maximum Temperature Rise (K) Maximum Marking Weight (g) Approximate SU16VD-30050 SU16VD-30040 SU16VD-30030 SU16VD-40020 SU16VD-40010 3.0 3.0 3.0 4.0 4.0 50 40 30 20 10 0.08 0.07 0.07 0.05 0.04 45 45 45 45 45 D30050 D30040 D30030 D40020 D40010 12.0 11.9 11.9 11.8 11.6 (c) KEMET Electronics Corporation * P.O. Box 5928 * Greenville, SC 29606 * 864-963-6300 * www.kemet.com LF0021_SU16VD * 3/27/2017 2 o0.7 4.0 min. 130.5 13 100.5 [mm] AC Line Filters - SU Coils, SU 16VD High Frequency Type umbering System Specifications Series Core size; shape (V: vertical) Ni-Zn ferrite core SU 16VD Rated current (30 stands for 3.0A) 250 VAC Inductance (050 stands for 50H) U 16V D - 30 050 Item Rated Voltage Withstanding Voltage 2,400 VAC (2 seconds, between lines) Insulation Resistance > 100 M at 500 VDC (between lines) Thermal Class E (120C) Operating Temperature Range -25C to T (T = 120 - temperature rise) Inductance Measurement Condition 1 kHz, 1 V, KC530 Frequency characteristic Frequency Characteristics 1M 1 6 3 Impedance () 100K 1 6 3 10K 1 30050 6 3 30040 1K 1 30030 6 3 40020 100 1 6 3 40010 10 1 6 3 1 1K 3 6 1 10K 3 6 1 100K 3 6 1 1M Frequency (Hz) 3 6 1 10M 3 30M Notes on Use C Line Filters 2 Shelf Life * Use within 6 months. If the product is used after a storage period of 6 months or longer, confirm its solderability before use. Storage Condition * Avoid storage in high temperature and high humidity environment, as such condition may deteriorate the solderability of external electrode. * Avoid storage in atmosphere containing toxic gases or acid (e.g., sulphur and chlorine), as such gas may deteriorate the solderability of external electrode. * Avoid storage near strong magnetic field, as such condition may magnetize the product. (c) KEMET Electronics Corporation * P.O. Box 5928 * Greenville, SC 29606 * 864-963-6300 * www.kemet.com LF0021_SU16VD * 3/27/2017 3 AC Line Filters - SU Coils, SU 16VD High Frequency Type KEMET Electronic Corporation Sales Offices For a complete list of our global sales offices, please visit www.kemet.com/sales. Disclaimer All product specifications, statements, information and data (collectively, the "Information") in this datasheet are subject to change. The customer is responsible for checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based on KEMET Electronics Corporation's ("KEMET") knowledge of typical operating conditions for such applications, but are not intended to constitute - and KEMET specifically disclaims - any warranty concerning suitability for a specific customer application or use. The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET's products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained. Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product-related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not be required. KEMET is a registered trademark of KEMET Electronics Corporation. (c) KEMET Electronics Corporation * P.O. Box 5928 * Greenville, SC 29606 * 864-963-6300 * www.kemet.com LF0021_SU16VD * 3/27/2017 4