IS61LV256
Integrated Circuit Solution Inc. 3
SR004-0D
DC ELECTRICAL CHARACTERISTICS (Over Operating Range)
Symbol Parameter Test Conditions Min. Max. Unit
VOH Output HIGH Voltage VCC = Min., IOH = 4.0 mA 2.4 V
VOL Output LOW Voltage VCC = Min., IOL = 8.0 mA 0.4 V
VIH Input HIGH Voltage 2.2 VCC + 0.3 V
VIL Input LOW Voltage 0.3 0.8 V
ILI Input Leakage GND ≤ VIN ≤ VCC Com. 1 1 µA
Ind. 5 5
ILO Output Leakage GND ≤ VOUT ≤ VCC, Outputs Disabled Com. 1 1 µA
Ind. 5 5
Notes:
1. VIL (min.) = 0.3V (DC); VIL (min.) = 2.0V (pulse width ≤ 2.0 ns).
VIH (max.) = VCC + 0.5V (DC); VIH (max.) = Vcc + 2.0V (pulse width ≤ 2.0 ns).
2. Not more than one output should be shorted at one time. Duration of the short circuit should not exceed 30 seconds.
CAPACITANCE(1,2)
Symbol Parameter Conditions Max. Unit
CIN Input Capacitance VIN = 0V 6 pF
COUT Output Capacitance VOUT = 0V 5 pF
Notes:
1. Tested initially and after any design or process changes that may affect these parameters.
2. Test conditions: TA = 25°C, f = 1 MHz, Vcc = 3.3V.
OPERATING RANGE
Range Ambient Temperature Speed VCC
Commercial 0°C to +70°C 8, 10, 12 3.3V, +10%, 5%
15, 20 3.3V ± 10%
Industrial 40°C to +85°C All 3.3V + 10%, 5%
POWER SUPPLY CHARACTERISTICS(1) (Over Operating Range)
-8 ns -10 ns -12 ns -15 ns -20 ns
Sym. Parameter Test Conditions
Min. Max. Min. Max. Min. Max. Min. Max. Min. Max. Unit
ICC Vcc Dynamic Operating VCC = Max., CE = VIL Com. 120 110 100 90 80 mA
Supply Current IOUT = 0 mA, f = fMAX Ind. 130 120 110 100 90
ISBTTL Standby Current VCC = Max., Com. 25 25 25 25 25 mA
(TTL Inputs) VIN = VIH or VIL Ind. 30 30 30 30 30
CE
≥
VIH, f = 0
ISB CMOS Standby VCC = Max., Com. 2 2 2 2 2 mA
Current (CMOS Inputs) CE
≤
VCC 0.2V, Ind. 5 5 5 5 5
VIN > VCC 0.2V, or
VIN
≤
0.2V, f = 0
Notes:
1. At f = fMAX, address and data inputs are cycling at the maximum frequency, f = 0 means no input lines change.