Notices N2PowerTM, a division of Qualstar Corporation. N2Power and the N2Power logo are registered trademarks of Qualstar Corporation. Copyright(c) 2014 - 2017 by Qualstar Corporation -- All Rights Reserved For warranty information refer to www.n2power.com Information contained in this document is copyrighted by Qualstar Corporation and is intended for use by customers and prospective customers to evaluate and integrate our power supplies. Customers and prospective customers may reproduce this document as needed for these purposes. Reproduction in whole or in part for any other purpose or by any other party is prohibited without prior written permission from Qualstar Corporation. Every effort has been made to keep the information contained in this document current and accurate as of the date of publication or revision. However, no guarantee is given or implied that the document is error-free or that it is accurate with regard to any specification. N2Power reserves the right to modify the design or specification without notice. This specification may not be construed as a contractual obligation except as specifically agreed to by N2Power in writing at the time of order. For information about this product specification, please write or call N2Power at: N2Power 130 W. Cochran St., Suite C Simi Valley, CA 93065 FAX: (805) 583-7749 Phone: (805) 583-7744 E-Mail: sales@n2power.com www.n2power.com 707151 Rev 08-28-17 i Table of Contents 1. Introduction ................................................................................................................... 1-1 1.1 Introduction .................................................................................................................... 1-1 1.2 Agency Compliance ........................................................................................................ 1-2 2. AC Input .......................................................................................................................... 2-1 2.1 Input Line Requirements .............................................................................................. 2-1 2.2 Input Over Current Protection...................................................................................... 2-1 2.3 Inrush Current Limiting ............................................................................................... 2-1 2.4 Low Input Voltage .......................................................................................................... 2-1 2.5 Leakage Current ............................................................................................................ 2-1 3. DC Outputs ..................................................................................................................... 3-1 3.1 Output Voltage Regulation ............................................................................................ 3-1 3.2 No Load Operation ......................................................................................................... 3-2 3.3 Output Ripple/Noise ...................................................................................................... 3-5 3.4 Redundant Operation: DLRDM20 ............................................................................... 3-7 3.5 Output Protection .......................................................................................................... 3-7 3.6 Output Rise Time ........................................................................................................... 3-9 3.7 Overshoot at Turn On/Turn Off .................................................................................... 3-9 4. General Specifications ................................................................................................ 4-1 4.1 Environmental................................................................................................................ 4-1 4.2 Mean Time Between Failures ....................................................................................... 4-1 4.3 Labeling/Marking ........................................................................................................... 4-2 4.4 Net Weight ...................................................................................................................... 4-2 4.5 Mounting......................................................................................................................... 4-3 4.6 Physical Dimensions ...................................................................................................... 4-3 4.7 Wiring Terminals ........................................................................................................... 4-4 4.8 Output Grounding .......................................................................................................... 4-4 4.9 Signal Pin Definitions .................................................................................................... 4-5 5. Efficiency ........................................................................................................................ 5-1 6. Signals ............................................................................................................................. 6-1 7. 6.1 DC_OK ............................................................................................................................ 6-1 6.2 DC OK LED .................................................................................................................... 6-1 6.3 Voltage Hold-Up Time ................................................................................................... 6-1 Ordering Information .................................................................................................. 7-1 707151 Rev 08-28-17 ii DL Series Product Specification 1.2 Agency Compliance Safety Complies with Standard Remarks United States and Canada UL 508 (Industrial Control Equipment) listed United States UL 1310 Class 2 Power Supply European EN 60950-1:2006+A11 Dielectric Withstand Voltage I/P-O/P: 4242Vdc; I/P-GND: 2121Vdc 1 minute Isolation Resistance I/P-O/P, I/P-FG, O/P-FG: > 100M/500Vdc EMC Complies with Standard Remarks RFI Emission EN 55022: 2006 Class B Emission Standard DL10 ~ DL100 series (10W ~ 100W Din Rail Power Supply) EN 61204-3: 2000 EN 61000-6-3: 2007 Immunity: EN 61000-3-2: 2006 Class A Limits for harmonic current emission EN 61000-3-3: 1995+A1:2001+A2: 2005 Limitation of voltage fluctuations and flicker in low-voltage supply system Immunity standard EN 55024: 1998+A1:2001_A2:2003 EN 61204-3: 2000 EN 61000-6-1: 2007 IEC 610000-4-2 Electrostatic discharge immunity IEC 610000-4-3 Radio frequency immunity IEC 610000-4-4 Electrical fast transient burst immunity IEC 610000-4-5 Power line surge immunity IEC 610000-4-6 RF common mode immunity IEC 610000-4-8 Power frequency magnetic field immunity IEC 610000-4-11 Voltage dips and short interruptions immunity Reduction of Hazardous Substances (RoHS) Complies with Standard Remarks EU Council 2002/95/EC RoHS Directive 2011/65/EU RoHS 2 Directive Marks of Conformance United States & Canada LISTED 39UZ IND. CONT. EQ. Underwriters Laboratories File E469384 (E469382 Class 2) TUV EU Council Table 1-1 Agency Compliance 707151 Rev 08-28-17 Introduction 1-2 2. AC Input 2.1 Input Line Requirements The following table defines the voltage and frequency requirements for the AC line inputs to the DIN Rail models which are capable of supplying full rated power in continuous operation throughout the specified ranges of voltages and frequencies. The power supply will automatically recover from AC power loss and is capable of starting under maximum load at the minimum AC input voltage described below. Parameter Minimum Nominal Maximum RMS Input Voltage 88VAC 100-240VAC 264VAC RMS Input Current - - 1.8A @ 100V 0.8A @ 240V Input Frequency 47Hz 50/60Hz 63Hz Table 2-1 DIN Rail Input Parameters 2.2 Input Over Current Protection The DIN Rail series incorporates a primary AC line fuse for input over current protection to prevent damage to the power supply and meet product safety requirements as outlined in Section 1.2. 2.3 Inrush Current Limiting The cold start inrush current is limited to 30A peak at 115VAC and 60A at 230VAC. Repetitive ON/OFF cycling of the AC input voltage shall not damage the power supply or cause the input fuse to fail. 2.4 Low Input Voltage The application of an input voltage below the minimums specified in Table 2-1 shall not cause damage to the power supply. 2.5 Leakage Current The leakage current from AC line or AC Neutral inputs to Earth Ground is <1Ma/230Vac. 707151 Rev 08-28-17 AC Input 2-1 3. DC Outputs 3.1 Output Voltage Regulation The DC output voltages shall remain within the Minimum and Maximum limits of Table 3-1 when measured at the power supply connector under all specified line, load and environmental conditions contained herein. The main output (V1) in the single output models (-12 thru -48V). Model Output Rated Voltage Regulation Minimum Nominal Maximum (VDC) (VDC) (VDC) DL10-12 V1 12 1% 11.88 12.00 12.12 DL10-15 V1 15 1% 13.85 15.00 15.15 DL10-24 V1 24 1% 23.76 24.00 24.24 DL20-12 V1 12 1% 11.88 12.00 12.12 DL20-15 V1 15 1% 13.85 15.00 15.15 DL20-24 V1 24 1% 23.76 24.00 24.24 DL40-12 V1 12 1% 11.88 12.00 12.12 DL40-15 V1 15 1% 13.85 15.00 15.15 DL40-24 V1 24 1% 23.76 24.00 24.24 DL40-48 V1 48 1% 47.52 48.00 48.48 DL60-12 V1 12 1% 11.88 12.00 12.12 DL60-15 V1 15 1% 13.85 15.00 15.15 DL60-24 V1 24 1% 23.76 24.00 24.24 DL60-48 V1 48 1% 47.52 48.00 48.48 DL100-12 V1 12 1% 11.88 12.00 12.12 DL100-15 V1 15 1% 13.85 15.00 15.15 DL100-24 V1 24 1% 23.76 24.00 24.24 DL100-48 V1 48 1% 47.52 48.00 48.48 DL150-24 V1 24 1% 23.76 24.00 24.24 DL150-48 V1 48 1% 47.52 48.00 48.48 DL240-24 V1 24 1% 23.76 24.00 24.24 DL240-48 V1 48 1% 47.52 48.00 48.48 DL480-24 V1 24 1% 23.76 24.00 24.24 DL480-48 V1 48 1% 47.52 48.00 48.48 Table 3-1 DL Output Voltage Specifications 707151 Rev 08-28-17 DC Outputs 3-1 DL Series Product Specification 3.2 No Load Operation The power supply will operate under a no load condition and will not result in damage to the supply. The power supply will remain stable and operate normally after application of loads. 3.2.1 Output Loading for Single Output Models The output currents listed in Table 3-2 require natural convection cooling at no more than 50C. Model DL10-12 Rated V1 Output Maximum Convection Load 12V 0.84A DL10-15 15V 0.67A DL10-24 24V 0.42A DL20-12 12V 1.7A DL20-15 15V 1.4A DL20-24 24V 1.0A DL40-12 12V 3.4A DL40-15 15V 2.7A DL40-24 24V 1.7A DL40-48 48V 0.85A DL60-12 12V 5.0A DL60-15 15V 4.0A DL60-24 24V 2.5A DL60-48 48V 1.25A DL100-12 12V 7.5A DL100-15 15V 6.4A DL100-24 24V 4.0A DL100-48 48V 2.0A DL150-24 24V 6.3A DL150-48 48V 3.2A DL240-24 24V 10.0A DL240-48 48V 5.0A DL480-24 24V 20.0A DL480-48 48V 10.0A DLRDM20 24V 20.0V Table 3-2 Max Load Currents Single Output Models 3.2.2 High Temperature Derating The DL series can be operated at elevated temperatures by derating the total maximum output power (or current) by 2.5%/C from 50C to 70C. 707151 Rev 08-28-17 DC Outputs 3-2 DL Series Product Specification Load vs. Temp. 100 Load (%) 80 60 40 20 -20 0 10 20 30 40 50 60 70 Ambient Temperature (C) Figure 3-1 Derating Curve: Models DL10 thru DL100 Series Load vs. I/P Voltage Ta = 25C 100 Load (%) 90 80 70 60 50 40 85 100 110 120 264Vac Input Voltage (Vac) 60Hz Figure 3-2 Load vs. Input Voltage: DL10 thru DL100 Series 707151 Rev 08-28-17 DC Outputs 3-3 DL Series Product Specification 150 Load (%) 112.5 For typical 3 seconds 100 60 Continuous 40 -10 0 10 30 20 40 50 60 70 Ambient Temperature (C) AC=230VAC and 115VAC Figure 3-3 Derating Curve: Models DL150, DL240 and DL480 Series Load vs. I/P Voltage Ta = 25C 100 Load (%) 90 80 70 60 50 40 85 100 110 120 264Vac Input Voltage (Vac) 60Hz Figure 3-4 Load vs. Input Voltage: Models DL150, DL240 and DL480 Series 707151 Rev 08-28-17 DC Outputs 3-4 DL Series Product Specification 100 Load (%) 80 60 40 20 -20 0 10 20 30 40 50 60 70 Ambient Temperature (C) Figure 3-5 DLRDM20 Derating Curve 3.3 Output Ripple/Noise Output ripple voltage and noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel. The ripple noise is measured from the output pin connectors (V+ and V-). 3.3.1 Ripple/Noise Limits: DIN Rail Models (DL10 through DL480) The ripple voltage of the outputs is measured at the pins of the mating connector. Ripple and noise shall not exceed the limits specified in Table 3-3 under any condition of line voltage and frequency specified in Section 2.1 and DC loading specified in Section 3.2.1. Model Output Voltage Maximum Ripple+Noise (peak-to-peak) DL10-12 V1 12V 100mV DL10-15 V1 15V 100mV DL10-24 V1 24V 120mV DL20-12 V1 12V 100mV DL20-15 V1 15V 100mV DL20-24 V1 24V 120mV DL40-12 V1 12V 100mV DL40-15 V1 15V 100mV DL40-24 V1 24V 120mV 707151 Rev 08-28-17 DC Outputs 3-5 DL Series Product Specification Model Output Voltage Maximum Ripple+Noise (peak-to-peak) DL40-48 V1 48V 180mV DL60-12 V1 12V 100mV DL60-15 V1 15V 100mV DL60-24 V1 24V 120mV DL60-48 V1 48V 180mV DL100-12 V1 12V 180mV DL100-15 V1 15V 180mV DL100-24 V1 24V 180mV DL100-48 V1 48V 250mV DL150-24 V1 24V 240mV DL150-48 V1 48V 480mV DL240-24 V1 24V 150mV DL240-48 V1 48V 300mV DL480-24 V1 24V 240mV DL480-48 V1 48V 480mV Table 3-3 Ripple Voltage: DL Output Models (DL10 through DL480) 3.3.2 Ripple/Noise Test Setup V Out Power Supply AC Line Load AC Neutral 47uf 0.1uf Load must be isolated from the earth ground of the power supply. DC Return Earth Ground Notes: 1. Load the output with its minimal load current. 2. Connect the probes as shown but keep them as close as possible to the output terminals. 3. Differential Oscilloscope Repeat the measurement with maximum load on the output. Figure 3-6 Ripple Noise Measurement Setup 707151 Rev 08-28-17 DC Outputs 3-6 DL Series Product Specification 3.4 Redundant Operation: DLRDM20 Three of the DLRDM20 accessories may be connected in parallel to provide higher output power and greater reliability for redundant or N+1 configurations. 1+1 Redundancy: 1+N Redundancy: Using 1 more PSU as the redundant unit PSU Using more PSUs as the redundant units to increase the reliability PSU PSU PSU PSU PSU PSU PSU Vin Vin Vin Vin Vin Vin DLRDM2 DLRDM2 Vout Vou Vout DLRDM2 Vou Vout DLRDM2 Vout Load Load Single Use: Connecting only one PSU to one DLRDM20 to reduce the stress of the diodes and increase the reliability PSU Vin PSU Vin Vin DLRDM2 Vin DLRDM2 Vout Vout Load Figure 3-7 DLRDM20 Typical Applications Terminal Pin # Assignment (TB1) 6 4 3 2 5 4 TB2 TB1 3 1 2 1 Pin # 1 2 3,4 5 6 Assignment Vout+ VoutVinVin B+ Vin A+ Terminal Pin # Assignment (TB2) Pin # 1 2 3 4 Assignment Alarm B1 Alarm B2 Alarm A1 Alarm A2 Figure 3-8 DLRDM20 Terminal Block Pin Assignments 3.5 Output Protection There are three different output protection schemes designed to protect the load and the DL Series from component failures and extraordinary circumstances. 3.5.1 Over Temperature Protection (OTP) If the DL Series is operated without adequate cooling, it will sense an overtemperature condition 95C +/- 5C and shut itself down. It will not restart until it 707151 Rev 08-28-17 DC Outputs 3-7 DL Series Product Specification has cooled down to below its maximum operating temperature and the AC power is turned off and back on. The DLRDM20 does not have over temperature protection and this redundancy module will become defective in over temperature condition. 3.5.2 Over Voltage Protection (OVP) No single fault is able to cause a sustained over voltage condition on any output. When an over-voltage condition occurs, the power supply will shut down and will not restart until AC power is turned off and back on. The DIN Rail supply will latch -off under the following over voltage conditions: Model Minimum Nominal Maximum DL10-12 13.80V 15.90V 18.00V DL10-15 17.25V 19.75V 22.50V DL10-24 27.60V 31.80V 36.00V DL20-12 13.80V 15.90V 18.00V DL20-15 17.25V 19.75V 18.00V DL20-24 27.60V 31.80V 36.00V DL40-12 13.80V 15.90V 18.00V DL40-15 17.25V 19.75V 22.50V DL40-24 27.60V 31.80V 36.00V DL40-48 55.20V 63.60V 72.00V DL60-12 13.80V 15.90V 18.00V DL60-15 17.25V 19.75V 22.50V DL60-24 27.60V 31.80V 36.00V DL60-48 55.20V 63.80V 72.00V DL100-12 13.80V 15.90V 18.00V DL100-15 17.25V 19.75V 22.50V DL100-24 27.60V 31.80V 36.00V DL100-48 55.20V 63.60V 72.00V DL150-24 29.00V 31.00V 33.00V DL150-48 56.00V 60.50V 65.00V DL240-24 28.00V 30.50V 33.00V DL240-48 56.00V 60.50V 65.00V DL480-24 29.00V 31.00V 33.00V DL480-48 56.00V 60.50V 65.00V Table 3-4 Over Voltage Protection Limits 3.5.3 Over Current Protection (OCP) For model DL150: works within 105~150% rated output power for more than three seconds and then shutdown o/p voltage with auto-recovery, >150% rated power or short circuit is constant current limiting. If o/p drops to 40% rating output voltage the 707151 Rev 08-28-17 DC Outputs 3-8 DL Series Product Specification supply will shut down and auto recover five times. If fault condition is not removed within these five times, the supply will latch off and requires a power cycle to recover. For model DL240: >150%, rated power or short circuit is constant current limiting, If o/p drops to 40% rating output voltage the supply will shut down and auto recover five (5) times. If fault condition is not removed within these five (5) times, the supply will latch off and requires a power cycle to recover. For model DL480: Hiccup mode: when the rated output power is within 105~150% for more than three seconds. Constant limit >150% rated power or short circuit. If o/p drops to 40% rating output voltage the supply will shut down and auto recover five times. If fault condition is not removed within these five times, the supply will latch off and requires a power cycle to recover. 3.5.4 Short Circuit Protection A short circuit is defined as an impedance of less than 0.1 ohms placed between DC RETURN and any output. A short circuit will cause no damage to the power supply, but will cause it to shutdown. The power supply will periodically attempt a restart until the short circuit condition is removed. After successfully restarting, the power supply will operate normally. 3.6 Output Rise Time All output voltages shall rise from 10% to 90% of nominal output voltage (as specified in Table 3-1) within 30ms to 100ms. The output voltages waveform must be a monotonic ramp from 10% to 90% of final setpoint within the regulation band under any loading conditions specified in the respective load current tables in Table 3-2. For the purposes of this specification, a monotonic ramp is defined as always having a positive slope of from zero to 10*Vout volts/millisecond. During any 5-millisecond portion of the ramp, its slope must be greater than 5% of its rated voltage per millisecond. 3.7 Overshoot at Turn On/Turn Off The DL10 through DL100 series do not support the overshoot feature. The DL150, DL240 and DL480 series support over and under overshoot <+/-5%. 707151 Rev 08-28-17 DC Outputs 3-9 4. General Specifications 4.1 Environmental The DL Series meets or exceeds the following environmental specifications: Parameter Conditions Specification Remarks Temperature Operating -20C to 70C DL10-100 Series, DLRDM20 10C to 70C DL150 -25C to 70C DL240, DL480 Non-Operating -40C to 85C Operating 90% Maximum Non-Condensing Non-Operating 95% Maximum Non-Condensing Altitude Operating 6,561 feet MSL Max. 2,000 meters Vibration No damage 2.0 G RMS Maximum 10-500Hz, 10-min/1cycle,60 min each along x, y, z axis. Mounting: Compliance to IEC60068-2-6 Relative Humidity Table 4-1 Environmental Specifications 4.2 Mean Time Between Failures The calculated MTBF of all models is equal to or greater than the specified hours of continuous operation at maximum output loading and worst-case input line voltage with convection cooling at 25C. N2Power does not warrant the MTBF to be representative of any particular unit. The MTBF of the power supply is calculated with an 80% confidence level in accordance with (MIL-HDBK-217F). Actual failure rates vary from unit to unit. Model MTBF DL10-12, -15 & -24 562.7K HRS DL20-12 120.4K HRS DL20-15 131.3K HRS DL20-24 125.9K HRS DL40-12, -15, 24 & -48 947.2K HRS DL60-12, -15, 24 & -48 944.6K HRS DL100-12, -15, 24 & -48 120.4K HRS DL150-24 & -48 62.7K HRS DL240-24 & -48 56.7K HRS DL480-24 & -48 65.9K HRS DLRDM20 TBD Table 4-2 MTBF by Model 707151 Rev 08-28-17 General Specifications 4-1 DL Series Product Specification 4.3 Labeling/Marking The power supply is marked and labeled with the N2Power logo and part number, model number, input and output specifications, production code, appropriate safety agency logos and CE mark. Typical labels are pictured below. DL150-24 +V ADJ. INPUT : 100 - 240VAC 2.0A 50 / 60Hz DC ON OUTPUT : 24V 6.25A (MAX. 150W) ON OFF SW1 LISTED 39UZ IND. CONT. EQ. SW2 DL100-12 *Maximum surrounding air temperature : 50C(full load). *Instructions for installation in a pollution degree 2 environment. *Suitable electric wire : 26~10 AWG (IEC 0.13~5.26mm). *Use Copper Conductors Only, Tighten To 4.4 (Lb-in) for 3 pin, Tighten To 7.0 (Lb-in) for 6 pin. L N Figure 4-1 Sample DL Label 4.4 Model: Net Weight DL40 DL60 DL100 DL150/240 DL480 DLRDM20 DL10 DL20 Pounds 0.34 0.36 0.72 0.76 0.99 2.35 3.30 1.21 Ounces 5.46 5.82 11.40 12.10 15.90 37.60 11.40 19.40 Kilograms 0.15 0.17 0.32 0.34 0.45 1.07 1.50 0.55 Table 4-3 DL Net Weights 707151 Rev 08-28-17 General Specifications 4-2 DL Series Product Specification 4.5 Mounting The DL power supplies may be mounted on DIN rail TS35/ 7.5 or 15. 4.6 Physical Dimensions Figure 4-2 DL Dimensions 707151 Rev 08-28-17 General Specifications 4-3 DL Series Product Specification 4.7 Wiring Terminals The user must furnish all connectors. The DIN Rail input and output connectors use screw terminals. Models Wire Gauge for Terminals DL10 thru DL100 12~24 AWG ( IEC 0.5~2.5mm) DL150 thru DL450 10~26 AWG ( IEC 0.13~5.26mm) Table 4-4 Wire Gauge for Terminals by Model 4.8 Output Grounding The DC RETURN signal may be connected to the power supply chassis ground (safety earth) DIN Terminal next to the neutral AC line. See Figure 4-3. DL100-12 Figure 4-3 DL Ground Location 707151 Rev 08-28-17 General Specifications 4-4 DL Series Product Specification 4.9 Signal Pin Definitions * Signal pin definitions reside on the product labels on the front of the power supplies by the screw terminal connectors. * Identical signal names are connected together on all connectors TB2 4 5 6 Terminal Pin # Assignment (TB1) P in # 1 2 3 Assignment FG AC/N AC/L Terminal Pin # Assignment (TB2) P in # 4 5 6 1 2 Assignment +DC -DC DC OK 3 TB1 Table 4-5 DL10 & DL20 Signal Pin Definitions TB2 4 5 6 7 8 9 Terminal Pin # Assignment (TB1) P in # 1 2 3 Assignment FG AC/N AC/L Terminal Pin # Assignment (TB2) P in # 4,5 6,7 8,9 1 2 Assignment +DC -DC DC OK 3 TB1 Table 4-6 DL40, DL60 & DL100 Signal Pin Definitions 707151 Rev 08-28-17 General Specifications 4-5 DL Series Product Specification TB2 4 5 6 Terminal Pin # Assignment (TB1) 7 8 9 P in # 1 2 3 Assignment FG AC/L AC/N Terminal Pin # Assignment (TB2) P in # 1 2 3 4 5,6 Assignment +DC -DC INH+ INHRelay Contact Switch # Assignment SW # SW1 SW2 1 Assignment Peak Load Setting Remote ON/OFF Setting 3 2 TB1 Table 4-7 DL150 & DL240 Signal Pin Definition TB2 1 2 3 4 5 6 Terminal Pin # Assignment (TB1) 7 8 9 10 P in # 1 2 3 Assignment FG AC/L AC/N Terminal Pin # Assignment (TB2) P in # 1,2,3 4,5,6 7 8 9,10 Assignment +DC -DC INH+ INHDC OK Switch # Assignment SW # SW1 SW2 1 2 Assignment Peak Load Setting Remote ON/OFF Setting 3 TB1 Table 4-8 DL480 Signal Pin Definitions 707151 Rev 08-28-17 General Specifications 4-6 DL Series Product Specification 6 5 4 3 2 Terminal Pin # Assignment (TB1) 1 P in # 1 2 3,4 5 6 TB1 Assignment Vout+ VoutVinVin B+ Vin A+ Terminal Pin # Assignment (TB2) P in # 1 2 3 4 TB2 4 3 2 1 Assignment Alarm B1 Alarm B2 Alarm A1 Alarm A2 Table 4-9 DLRDM20 Signal Pin Definitions 707151 Rev 08-28-17 General Specifications 4-7 5. Efficiency The efficiencies for the DIN Rail power supplies are listed below. They were measured at full load, 25C, at 230AC. DL: Output Load AC Efficiency DL10 12V 0.84A 230VAC 81% DL10 15V 0.67A 230VAC 81% DL10 24V 0.42A 230VAC 81% DL20 12V 1.7A 230VAC 83% DL20 15V 1.4A 230VAC 85% DL20 24V 1.0A 230VAC 86% DL40 12V 3.4A 230VAC 84% DL40 15V 2.7A 230VAC 84% DL40 24V 1.7A 230VAC 84% DL40 48V 0.85A 230VAC 85% DL60 12V 5.0A 230VAC 86% DL60 15V 4.0A 230VAC 87% DL60 24V 2.5A 230VAC 87% DL60 48V 1.25A 230VAC 88% DL100 12V 7.5A 230VAC 87% DL100 15V 6.4A 230VAC 87% DL100 24V 4.0A 230VAC 88% DL100 48V 2.0A 230VAC 87% DL150 24V 6.3A 230VAC 87% DL150 48V 3.2A 230VAC 87% DL240 24V 10.0A 230VAC 91% DL240 48V 5.0A 230VAC 92% DL480 24V 20.0A 230VAC 93% DL480 48V 10.0A 230VAC 94% Table 5-1 DL Output Currents at Rated Efficiency 707151 Rev 08-28-17 Efficiency 5-1 6. Signals 6.1 DC_OK The DC_OK signal is the signal that is driven by an open-collector transistor. The electrical specifications for the DC_OK outputs are described in Table 6-1. Signal Type Power On Delay Models DL10 thru 100 <800ms Models DL150 and 240 <700ms Model DL480 <800ms Rise Time Models DL10 and 20 <100ms/230VAC at full load Models DL40 and 60 <50ms/230VAC at full load Model DL100 <40ms/230Vac at full load Models DL150 and 240 <30ms/230VAC/115VAC at full load Model DL480 <100ms/230VAC/115VAC at full load PS DC _OK Output Models DL10 and DL20 Open collector. Max:40mA. Model DL40 Relay contact (30VDC/1A,120VAC/1A) Models DL60 and DL100 Relay contact (24VDC/1A,120/1A) Models DL150 and DL240, 60Vdc/0.3A, 30VDC/1A, 30VAC/0.5A resistive load Model DL480, open collector signal Table 6-1 DL Status and Control Signal Specifications 6.2 DC OK LED A green LED on DL10-DL480 illuminates when DC-OK signal is true (high). 6.3 Voltage Hold-Up Time The power supply will maintain output regulation per Table 3-1 despite a loss of input power. The Hold-Up Time is as follows: Models Hold-Up Time DL10 thru DL100 16ms /115VAC at full load and >32ms/230VAC DL150 16ms/115VAC at full load and 32ms/230VAC DL240 22ms/115VAC at full load and 32ms/230VAC DL480 16ms/115VAC at full load and 16ms/230V Table 6-2 Hold-Up Time by Model 707151 Rev 08-28-17 Signals 6-1 7. Ordering Information The following table provides the N2Power part numbers that should appear on your purchase order and will appear on any N2Power correspondence: Model Number V1 N2Power Part Number DL10-12 12V 400300-01-8 DL10-15 15V 400300-02-6 DL10-24 24V 400300-03-4 DL20-12 12V 400301-01-6 DL20-15 15V 400301-02-4 DL20-24 24V 400301-03-2 DL40-12 12V 400302-01-4 DL40-15 15V 400302-02-2 DL40-24 24V 400302-03-0 DL40-48 48V 400302-04-8 DL60-12 12V 400303-01-2 DL60-15 15V 400303-02-0 DL60-24 24V 400303-03-8 DL60-48 48V 400303-04-6 DL100-12 12V 400304-01-0 DL100-15 15V 400304-02-8 DL100-24 24V 400304-03-6 DL100-48 48V 400304-04-4 DL150-24 24V 400305-01-7 DL150-48 48V 400305-02-5 DL240-24 24V 400306-01-5 DL240-48 48V 400306-02-3 DL480-24 24V 400307-01-3 DL480-48 48V 400307-02-1 DLRDM20 24V 400308-01-1 Table 7-1 DL Part Numbers All DL power supplies are RoHS compliant For warranty information refer to www.n2power.com. Direct all questions, orders or requests for quotation as follows: N2Power Order Desk: orders@n2power.com Fax (Attention N2Power): 805-583-7749 Sales: sales@n2power.com 805-583-7744 x122 Technical Support: techsupport@n2power.com 805-583-7744 x119 Address: 130 W. Cochran St., Suite C, Simi Valley CA 93065 707151 Rev 08-28-17 Powered by TCPDF (www.tcpdf.org) Ordering Information 805-583-7744 x112 7-1