SUPER-LOW CURRENT CONSUMPTION 150 mA VOLTAGE REGULATOR WITH BUILT-IN HIGH-ACCURACY VOLTAGE DETECTOR AND RESET INPUT FUNCTION
Rev.2.1_00 S-1702 Series
Seiko Instruments Inc. 11
2. Discharge shunt circuit (discharge shunt function) (S-1702Axx, Bxx, Cxx, Exx, Fxx, Gxx, Jxx, Lxx, Nxx)
Table 8
(Ta = +25°C unless otherwise specified)
Item Symbol Condition Min. Typ. Max. Unit
Test
Circuit
“L” output, Nch on resistor RLOW V
DS = 0.5 V, VGS = 6.5 V – 100 – Ω 3
3. Detector output circuit (VDOUT pin)
Table 9
Nch open drain output (S-1702xAx, xDx, xGx) (Ta = +25°C unless otherwise specified)
Item Symbol Condition Min. Typ. Max. Unit
Test
Circuit
Output current IDOUT1 Output transistor: Nch,
VDS = 0.5 V, VDD = 1.2 V 1.36 2.55 – mA 7
Leakage current ILEAK Output transistor: Nch,
VDS = 5.5 V, VDD = 5.5 V – – 100 nA 7
CMOS output (S-1702xBx, xCx, xEx, xFx, xHx, xJx)
Item Symbol Condition Min. Typ. Max. Unit
Test
Circuit
IDOUT2 Output transistor: Nch,
VDS = 0.5 V, VIN = 1.2 V 1.36 2.55 – mA 7
Output current
IDOUT3 Output transistor: Pch,
VDS = 0.5 V, VIN = 5.5 V 1.71 2.76 – mA 8
4. RESX pin (S-1702Axx, Bxx, Cxx, Dxx, Exx, Fxx, Gxx, Hxx)
Table 10
(Ta = +25°C unless otherwise specified)
Item Symbol Condition Min. Typ. Max. Unit
Test
Circuit
RESX pin input voltage “H”*1 VSH2 V
IN = VOUT(S) + 1.0 V, RL = 1.0 kΩ 1.2 – – V 4
RESX pin input voltage “L” VSL2 V
IN = VOUT(S) + 1.0 V, RL = 1.0 kΩ – – 0.3 V 4
S-1702xxA −0.1 – 0.1 μA 4
S-1702xxB −0.1 – 0.1 μA 4
RESX pin input current “H” ISH2 V
IN = 6.5 V, VRESX = 6.5 V
S-1702xxC −0.1 – 0.1 μA 4
S-1702xxA −0.1 – 0.1 μA 4
S-1702xxB −0.1 – 0.1 μA 4
RESX pin input current “L” ISL2 V
IN = 6.5 V, VRESX = 0 V
S-1702xxC −0.1 – 0.1 μA 4
*1. VOUT(S): specified output voltage value
5. Pull-up / pull-down resistor value of ON / OFF pin and RESX pin (S-1702
xx
B,
xx
C,
xx
D,
xx
E,
xx
F
xx
G,
xx
H,
xx
J)
Table 11
(Ta = +25°C unless otherwise specified)
Item Symbol Condition Min. Typ. Max. Unit
Test
Circuit
Pull-up / pull-down resistor RPULL – – 2.0 – MΩ 4