DC Input Modules FEATURES * Fast Switching Polarized Input Types * UL, CSA, CE, TUV Certified (TUV not available on OpenLine (R)) * Optical Isolation * OpenLine(R) and G5 Modules have Built-in Status LED 70L-IDC 70G-IDC 70-IDC 70M-IDC CIRCUITRY OpenLine(R) Standard, Mini, G5 + I/O MODULE PIN # Rx 1 TYPICAL WIRING FOR MODULE 0 VDC 2 INPUT DEVICE 1 1 FILTER OPTICAL ISOLATION FILTER OPTICAL ISOLATION - +VCC 3 INPUT VOLTAGE HYST. CIRC. CURRENT REGULATING OUTPUT INPUT DEVICE + 2 2 3 3 + DC SUPPLY 4 - GROUND 5 4 4 TERMINAL BLOCK # Status LED in G5 modules only. 6 Vcc A + HYSTERESIS B 7 CH. A STATUS 5 GND 8 CH. B STATUS 9 MODULE ID HYSTERESIS - BASE OR RACK 0 MODULE SPECIFICATIONS: By Package Style Package Style I/O Modules 1 2 3 Specifications Units Output Current Range Minimum Output Breakdown Voltage Isolation Voltage1 Vibration2 Mechanical Shock3 Storage Temp. Range Operating Temp. Range Warranty mA Vdc Vrms C C Std (70-) Mini (70M-) G5 (70G-) OL (70L-) 1-50 50 4000 MIL-STD-202 MIL-STD-202 -40 to 125 -40 to 100 Lifetime 1-50 50 4000 MIL-STD-202 MIL-STD-202 -40 to 125 -40 to 100 Lifetime 1-50 50 4000 MIL-STD-202 MIL-STD-202 -40 to 125 -40 to 100 Lifetime 1-50 50 2500 IEC68-2-6 IEC68-2-27 -40 to 100 -40 to 85 Lifetime Field to logic and channel-to-channel if Grayhill racks are used. MIL-STD-202, Method 204, 20G, 10-2000 Hz or IEC68-2-6, 0.15 mm/sec2, 10-150 Hz. MIL-STD-202, Method 213, Condition F, 1500G or IEC68-2-27, 11 mS, 15g. I/O 18 Grayhill, Inc. * 561 Hillgrove Avenue * LaGrange, Illinois 60525-5997 * USA * Phone: 708-354-1040 * Fax: 708-354-2820 * www.grayhill.com DC Input Modules SPECIFICATIONS: By Part Number Standard and Miniature Modules Type/Function Grayhill Part Number Miniature, Polarized Standard, Non-Polarized Specifications Units Maximum Input Voltage Input Voltage Range1 Input Current @ Maximum Input Voltage Maximum Turn-On Time Maximum Turn-Off Time Nominal Input Resistance (Rx) Maximum Pick-Up Voltage (Output Low) Minimum Drop-Out Voltage (Output High) Nominal Logic Voltage (Vcc) Logic Voltage Range Max. Logic Supply Current @ Nominal Vcc Vdc Vdc mA mSec mSec Vdc Vdc Vdc Vdc mA 70M-IDC5 70-IDC5 70-IDC5B 32 3-32 18 0.20 0.40 1.8K 3 1 5 3-6 10 32 3-32 18 0.050 0.075 1.8K 3 1 5 3-6 18 70-IDC5K 16 2.5-16 30 0.025 0.030 500 2.5 1 5 3.5-6 18 70M-IDC15 70-IDC15 32 3-32 18 0.20 0.40 1.8K 3 1 15 8-18 10 70M-IDC24 70-IDC24 32 3-32 18 0.20 0.40 1.8K 3 1 24 15-30 10 G5 Modules Type/Function Grayhill Part Number G5, Polarized, Status LED 70G-IDC5 Specifications Units Maximum Input Voltage Input Voltage Range1 Input Current @ Maximum Input Voltage Maximum Turn-On Time Maximum Turn-Off Time Nominal Input Resistance (Rx) Maximum Pick-Up Voltage (Output Low) Minimum Drop-Out Voltage (Output High) Nominal Logic Voltage (Vcc) Logic Voltage Range Max. Logic Supply Current @ Nominal Vcc Vdc Vdc mA mSec mSec Vdc Vdc Vdc Vdc mA 32 3-32 18 0.20 0.40 1.8K 3 1 5 4.5-6 10 70G-IDC5B 70G-IDC5D 70G-IDC5K 32 3-32 18 0.050 0.075 1.8K 3 1 5 4.5-6 18 28 2.5-28 23 0.050 0.075 1.2K 2.5 1 5 4.5-6 10 16 2.5-16 30 0.025 0.030 500 2.5 1 5 4.5-6 18 70G-IDC15 70G-IDC24 32 3-32 18 0.20 0.40 1.8K 3 1 15 10-18 10 32 3-32 18 0.20 0.40 1.8K 3 1 24 17-30 10 OpenLine(R) Modules Type/Function Grayhill Part Number Dual, Polarized 70L-IDCB Specifications Units Maximum Input Voltage Input Voltage Range1 Input Current @ Max. Input Voltage Maximum Turn-on Time Maximum Turn-off Time Nominal Input Resistance (Rx) Maximum Pick-Up Voltage (Output Low) Minimum Drop-Out Voltage (Output High) Nominal Logic Voltage (Vcc) Logic Voltage Range Max. Logic Supply Current @ Nominal Vcc Module ID Resistance to Logic Ground Vdc Vdc mA mSec mSec Vdc Vdc Vdc Vdc 32 0-32 18 0.20 0.40 1800 3 0.9 5 4.5-28 32 0-32 18 0.05 0.075 900 3 0.9 5 4.5-28 mA 6/CH 0 6/CH 0 I/O Modules 1 70L-IDC Available from your local Grayhill Distributor. For prices and discounts, contact a local Sales Office, an authorized local Distributor or Grayhill. For input voltages in the range of 90 to 140 Vdc, use AC input modules 70-IAC5, 70M-IAC5, 70G-IAC5 or 70L-IAC. For input voltages in the range of 180 to 280 Vdc, use AC input modules 70-IAC5A, 70M-IAC5A, 70G-IAC5A or 70L-IACA. Grayhill, Inc. * 561 Hillgrove Avenue * LaGrange, Illinois 60525-5997 * USA * Phone: 708-354-1040 * Fax: 708-354-2820 * www.grayhill.com I/O 19