Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Lxx06xx & Qxx06xx & Qxx06xHx Series (R) Description Sensitive type devices guarantee gate control in Quadrants I & IV needed for digital control circuitry. Standard type devices normally operate in Quadrants I & III triggered from AC line. Alternistor type devices only operate in quadrants I, II, & III and are used in circuits requiring high dv/dt capability. Features & Benefits contact bounce that create voltage transients t3P)4DPNQMJBOU Agency Approval Agency t(MBTToQBTTJWBUFE junctions Agency File Number t7PMUBHFDBQBCJMJUZVQ to 1000 V L Package: E71639 (R) t4VSHFDBQBCJMJUZVQ to 85 A Main Features Symbol IT(RMS) VDRM /VRRM IGT (Q1) Value Unit 6 A 400 to 1000 V 5 to 50 mA t&MFDUSJDBMMZJTPMBUFE "L - Package" is UL recognized for 2500Vrms t4PMJETUBUFTXJUDIJOH eliminates arcing or t/PDPOUBDUTUPXFBSPVU from reaction of switching events t3FTUSJDUFE PSMJNJUFE 3'* generation, depending on activation point of sine wave t3FRVJSFTPOMZBTNBMMHBUF activation pulse in each half-cycle Applications Excellent for AC switching and phase control applications such as heating, lighting, and motor speed controls. Schematic Symbol Typical applications are AC solid-state switches, light dimmers, power tools, home/brown goods and white goods appliances. MT2 Alternistor Triacs (no snubber required) are used in applications with extremely inductive loads requiring highest commutation performance. MT1 Internally constructed isolated packages are offered for ease of heat sinking with highest isolation voltage. G Absolute Maximum Ratings -- Sensitive Triac (4 Quadrants) Symbol IT(RMS) ITSM I2t Parameter RMS on-state current (full sine wave) Non repetitive surge peak on-state current (full cycle, TJ initial = 25C) IGTM I2t Value for fusing Critical rate of rise of on-state current IG = 50mA with 0.1s rise time Peak gate trigger current PG(AV) Average gate power dissipation di/dt Tstg TJ Lxx06Ly Lxx06Vy / Lxx06Dy/ Lxx06Ry f = 50 Hz f = 60 Hz tp = 8.3 ms TC = 80C TC = 85C t = 20 ms t = 16.7 ms f = 120 Hz TJ = 110C tp c 10 s Storage temperature range Operating junction temperature range Value Unit 6 A 50 60 15 A2s 70 A/s A TJ = 110C 1.6 A TJ = 110C 0.4 W -40 to 150 -40 to 110 C C Note: xx = voltage, y = sensitivity (c)2008 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. 61 Revised: July 9, 2008 Lxx06xx & Qxx06xx & Qxx06xHx Series 6.0A TRIACs 6 Amp bi-directional solid state switch series is designed for AC switching and phase control applications such as motor speed and temperature modulation controls, lighting controls, and static switching relays. Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Absolute Maximum Ratings -- Standard Triac Symbol IT(RMS) Parameter Non repetitive surge peak on-state current (full cycle, TJ initial = 25C) I2t I2t Value for fusing Unit 6 A Qxx06Ry / Qxx06Ny TC = 95C Qxx06Ly TC = 90C f = 50 Hz t = 20 ms 65 f = 60 Hz t = 16.7 ms 80 RMS on-state current (full sine wave) ITSM Value tp = 8.3 ms A 26.5 A2s di/dt Critical rate of rise of on-state current IG = 200mA with 0.1s rise time f = 120 Hz TJ = 125C 70 A/s IGTM Peak gate trigger current tp c 10 s; IGT c IGTM TJ = 125C 1.6 A PG(AV) Average gate power dissipation TJ = 125C 0.5 W Storage temperature range -40 to 150 C Operating junction temperature range -40 to 125 C Tstg TJ Note: xx = voltage, y = sensitivity Absolute Maximum Ratings -- Alternistor Triac (3 Quadrants) Symbol IT(RMS) Parameter RMS on-state current (full sine wave) Qxx06LHy TC = 95C Qxx06RHy / Qxx06NHy Qxx06VHy / Qxx06DHy TC = 100C f = 50 Hz ITSM t = 20 ms Non repetitive surge peak on-state current (full cycle, TJ initial = 25C) f = 60 Hz I2t I2t Value for fusing t = 16.7 ms tp = 8.3 ms Qxx06VHy Qxx06DHy Qxx06LHy Qxx06RHy Qxx06NHy Qxx06VHy Qxx06DHy Qxx06LHy Qxx06RHy Qxx06NHy Qxx06VHy Qxx06DHy Qxx06LHy Qxx06RHy Qxx06NHy Value Unit 6 A 55 80 A 65 85 17.5 A2s 30 di/dt Critical rate of rise of on-state current f = 120 Hz TJ = 125C 70 A/s IGTM Peak gate trigger current tp c 10 s; IGT c IGTM TJ = 125C 1.6 A PG(AV) Average gate power dissipation TJ = 125C 0.5 W Storage temperature range -40 to 150 C Operating junction temperature range -40 to 125 C Tstg TJ Note: xx = voltage, y = sensitivity Lxx06xx & Qxx06xx & Qxx06xHx Series 62 Revised: July 9, 2008 (c)2008 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to http://www.littelfuse.com/series/triac.html Please refer to http://www.littelfuse.com for current information. Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Electrical Characteristics (TJ = 25C, unless otherwise specified) -- Sensitive Triac (4 Quadrants) IGT Test Conditions VD = 12V RL = 60 8 VGT VGD VD = VDRM RL = 3.3 k8 TJ = 110C IH IT = 100mA dv/dt VD = VDRM Gate Open TJ = 100C Value Quadrant I - II - III IV MAX. ALL MAX. ALL Lxx06x5 Lxx06x6 Lxx06x8 5 5 5 10 10 20 1.3 MIN. Unit mA V 0.2 V MAX. 10 10 20 mA TYP. 30 20 30 20 40 30 V/s 400V 600V (dv/dt)c (di/dt)c = 3.2 A/ms TJ = 110C TYP. 1 2 2 V/s tgt IG = 2 x IGT PW = 15s IT = 8.5 A(pk) TYP. 3.0 3.0 3.2 s Electrical Characteristics (TJ = 25C, unless otherwise specified) -- Standard Triac Symbol IGT VGT Test Conditions VD = 12V RL = 60 8 VGD VD = VDRM RL = 3.3 k8 TJ = 125C IH IT = 200mA Value Quadrant Qxx06x4 25 50 dv/dt MAX. TYP. I - II - III MAX. 1.3 V ALL MIN. 0.2 V MAX. 50 50 mA mA 120 600V 100 MIN. 800V VD = VDRM Gate Open TJ = 100C Unit I - II - III IV 400V VD = VDRM Gate Open TJ = 125C Qxx06x5 50 75 V/s 85 1000V 100 (dv/dt)c (di/dt)c = 3.2 A/ms TJ = 125C TYP. 4 4 V/s tgt IG = 2 x IGT PW = 15s IT = 8.5 A(pk) TYP. 3.0 3.0 s Electrical Characteristics (TJ = 25C, unless otherwise specified) -- Alternistor Triac (3 Quadrants) Symbol IGT VGT Test Conditions VD = 12V RL = 60 VGD VD = VDRM RL = 3.3 k TJ = 125C IH IT = 100mA I - II - III MAX. I - II - III MAX. I - II - III MIN. ALL Unit mA V 0.2 V 15 35 400V 75 400 600V 50 300 800V Qxx06LHy / Qxx06RHy / Qxx06NHy 35 1.3 MIN. VD = VDRM Gate Open TJ = 125C VD = VDRM Gate Open TJ = 100C 10 MAX. Qxx06VHy / Qxx06DHy dv/dt Value Qxx06xH3 Qxx06xH4 Quadrant mA 200 400V 75 450 600V 50 350 800V 250 1000V 150 V/s (dv/dt)c (di/dt)c = 3.2 A/ms TJ = 125C MIN. 20 25 V/s tgt IG = 2 x IGT PW = 15s IT = 8.5 A(pk) TYP. 4.0 4.0 s Note: xx = voltage, x = package, y = sensitivity (c)2008 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. 63 Revised: July 9, 2008 Lxx06xx & Qxx06xx & Qxx06xHx Series 6.0A TRIACs Symbol Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Static Characteristics Symbol Test Conditions VTM ITM = 11.3A tp = 380 s Lxx06xy Qxx06xy IDRM / IRRM VDRM = VRRM MAX. Unit 1.60 V TJ = 25C 400 - 600V 20 A TJ = 110C 400 - 600V 0.5 mA TJ = 25C 400 - 1000V 50 A TJ = 125C 400 - 800V 2 TJ = 100C 1000V MAX. mA 3 400 - 800V 10 1000V 20 TJ = 125C 400 - 800V 3 TJ = 100C 1000V 2 TJ = 25C Qxx06xHy Value A mA Thermal Resistances Symbol Parameter Value L/Qxx06Ryy / L/Qxx06Nyy 1.8 L/Qxx06Lyy 3.3 L/Qxx06Vyy / L/Qxx06Dyy 3.2 L/Qxx06Ryy 45 L/Qxx06Lyy 50 L/Qxx06Vyy 70 Junction to case (AC) RR(J-C) Junction to ambient RR(J-A) Unit C/W C/W Note: xx = voltage, x = package, y = sensitivity, yy = type & sensitivity Figure 2: Normalized DC Gate Trigger Current for All Quadrants vs. Junction Temperature Figure 1: Definition of Quadrants ALL POLARITIES ARE REFERENCED TO MT1 + (+) I GT GATE MT1 I GT REF (-) MT1 I GT GATE (+) MT1 REF REF QII QI QIII QIV MT2 IGT I GT GATE 4.0 MT2 - + IGT IGT (TJ = 25C) (-) MT2 POSITIVE (Positive Half Cycle) Ratio of MT2 MT2 3.0 2.0 1.0 I GT GATE MT2 NEGATIVE (Negative Half Cycle) 0.0 MT1 -65 REF -40 -15 10 35 60 85 110 125 Junction Temperature (TJ)- C NOTE: Alternistors will not operate in QIV Note: Alternistors will not operate in QIV Lxx06xx & Qxx06xx & Qxx06xHx Series 64 Revised: July 9, 2008 (c)2008 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to http://www.littelfuse.com/series/triac.html Please refer to http://www.littelfuse.com for current information. Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Figure 4: Normalized DC Gate Trigger Voltage for All Quadrants vs. Junction Temperature 3.0 3.0 2.0 2.0 1.0 1.0 0.0 0.0 -65 -40 -15 10 35 60 85 110 125 -65 -40 -15 Junction Temperature (TJ)- C Figure 5: Power Dissipation (Typical) vs. RMS On-State Current 60 85 110 125 120 Maximum Allowable Case Temperature (TC) - C Average On-State Power Dissipation (PD(AV)) - Watts 35 Figure 6: Maximum Allowable Case Temperature vs. On-State Current (Sensitive Triac) 18 16 14 110 Lxx06Vy Lxx06Dy Lxx06Ry 100 12 10 8 6 CURRENT WAVEFORM: Sinusoidal LOAD: Resistive or Inductive CONDUCTION ANGLE: 360 4 2 0 90 Lxx06Ly 80 CURRENT WAVEFORM: Sinusoidal LOAD: Resistive or Inductive CONDUCTION ANGLE: 360 CASE TEMPERATURE: Measured as shown on Dimensional Drawings 70 60 0 2 4 6 8 10 12 14 16 0 1 RMS On-State Current (IT(RMS)) - Amps 2 3 4 5 6 7 RMS On-State Current (IT(RMS)) - Amps Figure 7: Maximum Allowable Case Temperature vs. On-State Current (Standard Triac) Figure 8: Maximum Allowable Case Temperature vs. On-State Current (Alternistor Triac) 130 Maximum Allowable Case Temperature (TC) - C 130 Maximum Allowable Case Temperature (TC) - C 10 Junction Temperature (TJ)- C 120 Qxx06Ry Qxx06Ny 110 100 Qxx06Ly 90 80 CURRENT WAVEFORM: Sinusoidal LOAD: Resistive or Inductive CONDUCTION ANGLE: 360 CASE TEMPERATURE: Measured as shown on Dimensional Drawings 70 Qxx06RHy Qxx06NHy Qxx06VHy Qxx06DHy 120 110 100 Qxx06LHy 90 80 CURRENT WAVEFORM: Sinusoidal LOAD: Resistive or Inductive CONDUCTION ANGLE: 360 CASE TEMPERATURE: Measured as shown on Dimensional Drawings 70 60 60 0 1 2 3 4 5 6 0 7 RMS On-State Current (IT(RMS)) - Amps (c)2008 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. 1 2 3 4 5 6 7 RMS On-State Current (IT(RMS)) - Amps 65 Revised: July 9, 2008 Lxx06xx & Qxx06xx & Qxx06xHx Series 6.0A TRIACs IH 4.0 IH (TJ = 25C) 4.0 Ratio of IH Ratio of IH (TJ = 25C) Figure 3: Normalized DC Holding Current vs. Junction Temperature Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Figure 9: Maximum Allowable Ambient Temperature vs. On-State Current (Sensitive / Standard Triac) Figure 10: Maximum Allowable Ambient Temperature vs. On-State Current (Alternistor Triac) 120 Maximum Allowable Ambient Temperature (TA) - C Maximum Allowable Ambient Temperature (TA) - C 120 100 Lxx06Ly Lxx06Ry 80 Qxx06Ly Qxx06Ry Qxx06Ny L/Qxx06Vy 60 CURRENT WAVEFORM: Sinusoidal LOAD: Resistive or Inductive CONDUCTION ANGLE: 360 FREE AIR RATING - NO HEATSINK 40 20 100 Qxx06LHy Qxx06RHy Qxx06NHy 80 Qxx06VHy 60 CURRENT WAVEFORM: Sinusoidal LOAD: Resistive or Inductive CONDUCTION ANGLE: 360 CASE TEMPERATURE: Measured as shown on Dimensional Drawing 40 20 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 0.0 RMS On-State Current (IT(RMS)) - Amps 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RMS On-State Current [IT(RMS)] - Amps Figure 11: On-State Current vs. On-State Voltage (Typical) Postitive or Negative Instantaneous On-State Current (iT) - Amps 20 TC = 25C 18 16 14 12 10 8 6 4 2 0 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 Postitive or Negative Instantaneous On-State Voltage (vT) - Volts Lxx06xx & Qxx06xx & Qxx06xHx Series 66 Revised: July 9, 2008 (c)2008 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to http://www.littelfuse.com/series/triac.html Please refer to http://www.littelfuse.com for current information. Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Figure 12: Surge Peak On-State Current vs. Number of Cycles (Sensitive / Standard Triac) 100 Peak Surge (Non-Repetitive) On-State Current (ITSM) - Amps Notes: 1. Gate control may be lost during and immediately following surge current interval. 2. Overload may not be repeated until junction temperature has returned to steady-state rated value. Lxx06Ly Lxx06Ry Lxx06Vy Lxx06Dy 10 1 1 10 100 1000 Surge Current Duration- Full Cycles Figure 13: Surge Peak On-State Current vs. Number of Cycles (Alternistor Triac) 100 SUPPLY FREQUENCY: 60 Hz Sinusoidal LOAD: Resistive RMS On-State Current: [IT(RMS)]: Maximum Rated Value at Specified Case Temperature Peak Surge (Non-Repetitive) On-State Current (ITSM) - Amps Qxx06LHy Qxx06RHy Qxx06NHy Notes: 1. Gate control may be lost during and immediately following surge current interval. 2. Overload may not be repeated until junction temperature has returned to steady-state rated value. Qxx06VHy Qxx06DHy 10 1 1 10 100 1000 Surge Current Duration- Full Cycles Note: xx = voltage, x = package, y = sensitivity, yy = type & sensitivity (c)2008 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. 67 Revised: July 9, 2008 Lxx06xx & Qxx06xx & Qxx06xHx Series 6.0A TRIACs SUPPLY FREQUENCY: 60 Hz Sinusoidal LOAD: Resistive RMS On-State Current: [IT(RMS)]: Maximum Rated Value at Specified Case Temperature Qxx06Ly Qxx06Ry Qxx06Ny Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Soldering Parameters Reflow Condition Pb - Free assembly tP TP Pre Heat 150C - Temperature Max (Ts(max)) 200C - Time (min to max) (ts) 60 - 190 secs Average ramp up rate (Liquidus Temp) (TL) to peak 5C/second max TS(max) to TL - Ramp-up Rate 5C/second max Reflow Temperature - Temperature Min (Ts(min)) - Temperature (TL) (Liquidus) 217C - Temperature (tL) 60 - 150 seconds Peak Temperature (TP) 260+0/-5 C Time within 5C of actual peak Temperature (tp) 20 - 40 seconds Ramp-down Rate 5C/second max Time 25C to peak Temperature (TP) 8 minutes Max. Do not exceed 280C tL TS(max) Ramp-do Ramp-down Preheat TS(min) tS 25 time to peak temperature Physical Specifications Terminal Finish Ramp-up TL Environmental Specifications Test 100% Matte Tin-plated AC Blocking (VDRM) Body Material Terminal Material UL recognized epoxy meeting flammability classification 94V-0 Temperature Cycling Copper Alloy Temperature/ Humidity Design Considerations High Temp Storage Careful selection of the correct device for the application's operating parameters and environment will go a long way toward extending the operating life of the Thyristor. Good design practice should limit the maximum continuous current through the main terminals to 75% of the device rating. Other ways to ensure long life for a power discrete semiconductor are proper heat sinking and selection of voltage ratings for worst case conditions. Overheating, overvoltage (including dv/dt), and surge currents are the main killers of semiconductors. Correct mounting, soldering, and forming of the leads also help protect against component damage. Low-Temp Storage Lxx06xx & Qxx06xx & Qxx06xHx Series Time Thermal Shock Autoclave Specifications and Conditions MIL-STD-750, M-1040, Cond A Applied Peak AC voltage @ 125C for 1008 hours MIL-STD-750, M-1051, 100 cycles; -40C to +150C; 15-min dwell-time EIA / JEDEC, JESD22-A101 1008 hours; 320V - DC: 85C; 85% rel humidity MIL-STD-750, M-1031, 1008 hours; 150C 1008 hours; -40C MIL-STD-750, M-1056 10 cycles; 0C to 100C; 5-min dwelltime at each temperature; 10 sec (max) transfer time between temperature EIA / JEDEC, JESD22-A102 168 hours (121C at 2 ATMs) and 100% R/H Resistance to Solder Heat MIL-STD-750 Method 2031 Solderability ANSI/J-STD-002, category 3, Test A Lead Bend MIL-STD-750, M-2036 Cond E 68 Revised: July 9, 2008 (c)2008 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to http://www.littelfuse.com/series/triac.html Please refer to http://www.littelfuse.com for current information. Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Dimensions -- TO-220AB (R-Package) -- Non-Isolated Mounting Tab Common with Center Lead O A O E AREA (REF.) 0.17 IN2 Dimension 8.13 .320 P MT2 B C 13.36 .526 D 7.01 .276 NOTCH IN GATE LEAD TO ID. NON-ISOLATED TAB F R G L H N K J Note: Maximum torque to be applied to mounting tab is 8 in-lbs, (0.904 Nm). M MT1 MT2 GATE Inches Millimeters Min Max Min Max A 0.380 0.420 9.65 10.67 B 0.105 0.115 2.67 2.92 C 0.230 0.250 5.84 6.35 D 0.590 0.620 14.99 15.75 E 0.142 0.147 3.61 3.73 F 0.110 0.130 2.79 3.30 G 0.540 0.575 13.72 14.61 H 0.025 0.035 0.64 0.89 J 0.195 0.205 4.95 5.21 K 0.095 0.105 2.41 2.67 L 0.060 0.075 1.52 1.91 M 0.085 0.095 2.16 2.41 N 0.018 0.024 0.46 0.61 O 0.178 0.188 4.52 4.78 P 0.045 0.060 1.14 1.52 R 0.038 0.048 0.97 1.22 Min Max Min Max A 0.380 0.420 9.65 10.67 B 0.105 0.115 2.67 2.92 Dimensions -- TO-220AB (L-Package) -- Isolated Mounting Tab TC MEASURING POINT O A O E AREA (REF.) 0.17 IN2 Dimension 8.13 .320 P B 13.36 .526 C D 7.01 .276 F R G L H K N J MT1 MT2 GATE M Note: Maximum torque to be applied to mounting tab is 8 in-lbs, (0.904 Nm). (c)2008 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. 69 Revised: July 9, 2008 Inches Millimeters C 0.230 0.250 5.84 6.35 D 0.590 0.620 14.99 15.75 E 0.142 0.147 3.61 3.73 F 0.110 0.130 2.79 3.30 G 0.540 0.575 13.72 14.61 H 0.025 0.035 0.64 0.89 J 0.195 0.205 4.95 5.21 K 0.095 0.105 2.41 2.67 L 0.060 0.075 1.52 1.91 M 0.085 0.095 2.16 2.41 N 0.018 0.024 0.46 0.61 O 0.178 0.188 4.52 4.78 P 0.045 0.060 1.14 1.52 R 0.038 0.048 0.97 1.22 Lxx06xx & Qxx06xx & Qxx06xHx Series 6.0A TRIACs TC MEASURING POINT Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Dimensions -- TO-263AB (N-Package) -- D2-PAK Surface Mount TC MEASURING POINT B AREA: 0.11 IN2 C V Dimension E MT2 7.01 .276 A 8.41 .331 S W U J K GATE MT1 G 8.13 .320 H F D 11.68 .460 2.16 .085 7.01 .276 7.01 .276 16.89 .665 8.89 .350 1.40 .055 3.81 .150 Inches Millimeters Min Max Min Max A 0.360 0.370 9.14 9.40 B 0.380 0.420 9.65 10.67 C 0.178 0.188 4.52 4.78 D 0.025 0.035 0.64 0.89 E 0.045 0.060 1.14 1.52 F 0.060 0.075 1.52 1.91 G 0.095 0.105 2.41 2.67 H 0.092 0.102 2.34 2.59 J 0.018 0.024 0.46 0.61 K 0.090 0.110 2.29 2.79 S 0.590 0.625 14.99 15.88 V 0.035 0.045 0.89 1.14 U 0.002 0.010 0.05 0.25 W 0.040 0.070 1.02 1.78 2.03 .080 6.60 .260 Dimensions -- TO-251AA (V-Package) -- V-PAK Through Hole TC MEASURING POINT E H D AREA: 0.040 IN2 Dimension 5.28 .208 J MT2 A 5.34 .210 B K C MT1 MT2 GATE F L G I Lxx06xx & Qxx06xx & Qxx06xHx Series 70 Revised: July 9, 2008 Inches Millimeters Min Max Min Max A 0.040 0.050 1.02 1.27 B 0.235 0.245 5.97 6.22 C 0.350 0.375 8.89 9.53 D 0.205 0.213 5.21 5.41 E 0.255 0.265 6.48 6.73 F 0.027 0.033 0.69 0.84 G 0.087 0.093 2.21 2.36 H 0.085 0.095 2.16 2.41 I 0.176 0.184 4.47 4.67 J 0.018 0.023 0.46 0.58 K 0.038 0.044 0.97 1.12 L 0.018 0.023 0.46 0.58 (c)2008 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to http://www.littelfuse.com/series/triac.html Please refer to http://www.littelfuse.com for current information. Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Dimensions -- TO-252AA (D-Package) -- D-PAK Surface mount E D TC MEASURING POINT MT2 5.28 .208 A 5.34 .210 B L O K J H M GATE F MT1 AREA : 0.040 IN2 G Dimension I Pad Layout for TO-252AA (D-Package) 6.71 .264 6.71 .264 1.60 .063 1.80 .071 3 .118 4.60 .181 (c)2008 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. 71 Revised: July 9, 2008 Inches Millimeters Min Max Min Max A 0.040 0.050 1.02 1.27 B 0.235 0.245 5.97 6.22 C 0.106 0.113 2.69 2.87 D 0.205 0.213 5.21 5.41 E 0.255 0.265 6.48 6.73 F 0.027 0.033 0.69 0.84 G 0.087 0.093 2.21 2.36 H 0.085 0.095 2.16 2.41 I 0.176 0.184 4.47 4.67 J 0.018 0.023 0.46 0.58 K 0.038 0.044 0.97 1.12 L 0.018 0.023 0.46 0.58 M 0.000 0.004 0.00 0.10 N 0.021 0.027 0.53 0.69 O 0 5 0 5 Lxx06xx & Qxx06xx & Qxx06xHx Series 6.0A TRIACs N MT2 C Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Product Selector Part Number Voltage Gate Sensitivity Quadrants Type Package Sensitive Triac TO-220L 5 mA Sensitive Triac TO-252 D-PAK 5mA Sensitive Triac TO-220R 5 mA Sensitive Triac TO-251 V-PAK 10 mA Sensitive Triac TO-220L 10 mA Sensitive Triac TO-252 D-PAK 10mA Sensitive Triac TO-220R 5 mA 10 mA Sensitive Triac TO-251 V-PAK 10 mA 20 mA Sensitive Triac TO-220L 10 mA 20 mA Sensitive Triac TO-252 D-PAK 10mA 20mA Sensitive Triac TO-220R X 10 mA 20 mA Sensitive Triac TO-251 V-PAK X 10 mA Alternistor Triac TO-251 V-PAK 10 mA Alternistor Triac TO-252 D-PAK 25 mA Standard Triac TO-220L 400V 600V Lxx06L5 X Lxx06D5 Lxx06R5 800V 1000V I - II - III IV X 5 mA 5 mA X X 5 mA X X 5mA Lxx06V5 X X 5 mA Lxx06L6 X X 5 mA Lxx06D6 X X 5 mA Lxx06R6 X X 5mA Lxx06V6 X X Lxx06L8 X X Lxx06D8 X X Lxx06R8 X X Lxx06V8 X Qxx06VH3 X Qxx06DH3 X X Qxx06L4 X Qxx06R4 X 25 mA Standard Triac TO-220R Qxx06N4 X 25 mA Standard Triac TO-263 D-PAK Qxx06RH3 X X 10mA Alternistor Triac TO-220R Qxx06LH4 X X X X 35 mA Alternistor Triac TO-220L Qxx06RH4 X X X X 35 mA Alternistor Triac TO-220R Qxx06VH4 X X X X 35 mA Alternistor Triac TO-251 V-PAK Qxx06DH4 X X X X 35 mA Alternistor Triac TO-252 D-PAK Qxx06NH4 X X X X 35 mA Alternistor Triac TO-263 D-PAK Qxx06L5 X X X 50 mA Standard Triac TO-220L Qxx06R5 X X X 50 mA Standard Triac TO-220R Qxx06N5 X X X 50 mA Standard Triac TO-263 D-PAK Packing Options Part Number Marking Weight Packing Mode Base Quantity Lxx06L/Ry Lxx06L/Ry 2.2 g Bulk 500 Lxx06L/RyTP Lxx06L/Ry 2.2 g Tube Pack 500 Lxx06DyTP Lxx06Dy 0.3 g Tube 750 Lxx06DyRP Lxx06Dy 0.3 g Embossed Carrier 2500 Lxx06VyTP Lxx06Vy 0.4 g Tube 750 Qxx06L/Ryy Qxx06L/Ryy 2.2 g Bulk 500 Qxx06L/RyyTP Qxx06L/Ryy 2.2 g Tube Pack 500 Qxx06NyyTP Qxx06Nyy 1.6 g Tube 500 Qxx06NyyRP Qxx06Nyy 1.6 g Embossed Carrier 500 Qxx06DyyTP Qxx06Dyy 0.3 g Tube 750 Qxx06DyyRP Qxx06Dyy 0.3 g Embossed Carrier 2500 Qxx06VyyTP Qxx06Vyy 0.4 g Tube 750 Note: xx = voltage; yy = sensitivity Lxx06xx & Qxx06xx & Qxx06xHx Series 72 Revised: July 9, 2008 (c)2008 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to http://www.littelfuse.com/series/triac.html Please refer to http://www.littelfuse.com for current information. Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs TO-252 Embossed Carrier Reel Pack (RP) Specifications Meets all EIA-481-2 Standards 0.059 DIA (1.5) * Cover tape 0.315 (8.0) MT1 / Cathode XXXXXX * DC 0.524 (13.3) DC 0.63 (16.0) DC Gate 6.0A TRIACs 0.157 (4.0) MT2 / Anode 12.99 (330.0) 0.512 (13.0) Arbor Hole Dia. Dimensions are in inches (and millimeters). 0.64 (16.3) Direction of Feed TO-263 Embossed Carrier Reel Pack (RP) Specifications Meets all EIA-481-2 Standards 0.63 (16.0) 0.157 (4.0) Gate 0.059 DIA (1.5) MT1 / Cathode 0.945 (24.0) 0.827 (21.0) * * Cover tape MT2 / Anode 0.512 (13.0) Arbor Hole Dia. 12.99 (330.0) Dimensions are in inches (and millimeters). 1.01 (25.7) Direction of Feed (c)2008 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to http://www.littelfuse.com for current information. 73 Revised: July 9, 2008 Lxx06xx & Qxx06xx & Qxx06xHx Series Teccor(R) brand Thyristors 6 Amp Sensitive, Standard & Alternistor (High Commutation) Triacs Part Numbering System Part Marking System Q 60 06 L H4 56 TO-252AA - (D Package) TO-251AA - (V Package) LEAD FORM DIMENSIONS xx : Lead Form Option (R) CURRENT 06: 6A PACKAGE TYPE L : TO-220 Isolated R : TO-220 Non-Isolated N : TO-263 (D2PAK) V : TO-251 (VPAK) D : TO-252 (DPAK) Lxx06xx & Qxx06xx & Qxx06xHx Series SENSITIVITY & TYPE Sensitive Triac: 3 : 3 mA (QI, II, III, IV) 5 : 5 mA (QI, II, III, IV) 6 : 5 mA (QI, II, III) 10 mA (QIV) 8 : 10 mA (QI, II, III) 20 mA (QIV) Standard Triac: 4 : 25 mA (QI, II, III) 5 : 50 mA (QI, II, III) Alternistor Triac: H3 : 10 mA (QI, II, III) H4 : 35 mA (QI, II, III) yxxxx VOLTAGE RATING 40 : 400V 60 : 600V 80 : 800V K0 : 1000V L6006V5 DEVICE TYPE L : Sensitive Triac Q : Triac or Alternistor (R) 74 Revised: July 9, 2008 (c)2008 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to http://www.littelfuse.com/series/triac.html Please refer to http://www.littelfuse.com for current information.