Digital Panel Meter K3TF CSM_K3TF_DS_E_4_1 Easy-to-use, Low-cost Digital Panel Meter that Accepts AC Input * Compact DIN-size (96 x 48 (W x H)) body. * Mounting thickness of only 3.5 mm required. * Highly visible display with 14.2-mm-high LEDs. * Detects and displays root-mean-square value of half-wave rectified current. * Confirms to EMC standards EN61010-1 (IEC61010-1). For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Note: This Panel Meter does not support scaling. Model Number Structure Model Number Legend K3TF 1 2 3 4 1, 2. Input Code V5: 0 to 199.9 mV V6: 0 to 1.999 V V7: 0 to 19.99 V V8: 0 to 199.9 V V9: 0 to 400 V A6: 0 to 1.999 mA A7: 0 to 19.99 mA A8: 0 to 199.9 mA A9: 0 to 1.999 A 3. Series No. 1: Current series 4. Supply Voltage 4: 100 to 120 VAC 5: 200 to 240 VAC Ordering Information List of Models Models with Line Monitor Range Measuring ranges Supply voltage 100 to 120 VAC AC voltage 200 to 240 VAC 0 to 199.9 V K3TF-V814 K3TF-V815 0 to 400 V K3TF-V914 K3TF-V915 1 K3TF Models with Signal Monitor Range Measuring ranges Supply voltage 100 to 120 VAC AC voltage AC current 200 to 240 VAC 0 to 199.9 mV K3TF-V514 K3TF-V515 0 to 1.999 V K3TF-V614 K3TF-V615 0 to 19.99 V K3TF-V714 K3TF-V715 0 to 1.999 mA K3TF-A614 K3TF-A615 0 to 19.99 mA K3TF-A714 K3TF-A715 0 to 199.9 mA K3TF-A814 K3TF-A815 0 to 1.999 A K3TF-A914 K3TF-A915 Note: The K3TF-V8@@ and K3TF-V9@@ do not conform to CE marking standards. Accessories (Order Separately) Name Appearance Model Water-resistive Soft Front Cover K32-L49SC Terminal Cover K32-L49TC Watertight Cover Y92A-49N Note: 1. Use the Mounting Bracket included with the K3TF for mounting. 2. The Terminal Cover is used for finger protection. It has no relation to water resistance. 2 K3TF Specifications Ratings Supply voltage 100 to 120 VAC (50/60 Hz); 200 to 240 VAC (50/60 Hz) Operating voltage range -15% to +10% of supply voltage Power consumption 4 VA (at max. load) Insulation resistance 10 M min. (at 500 VDC) between external terminal and case Dielectric strength 2,000 VAC min. for 1 min between input terminal and power supply 2,000 VAC min. for 1 min between external terminal and case Noise immunity 1,500 V on power supply terminals in normal or common mode Vibration resistance Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 10 min each in X, Y, and Z directions Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y, and Z directions Shock resistance Malfunction: 98 m/s2 for 3 times each in 6 directions Destruction: 294 m/s2 for 3 times each in 6 directions Ambient temperature Operating: -10 to 55C (with no icing) Storage: -20 to 65C (with no icing) Ambient humidity Operating: 35% to 85% (with no condensation) Ambient operating atmosphere No corrosive gas EMC (EMI) Emission Enclosure: Emission AC Mains: (EMS) Immunity ESD: Approved standard Conforms to EN61326+A1, EN61010-1 (IEC61010-1) Conforms to VDE0106/P100 (finger protection) when the terminal cover is mounted. EN61326+A1 Industry CISPR 11 Group 1 class A: CISRP16-1/-2 CISPR 11 Group 1 class A: CISRP16-1/-2 EN61326+A1 Industry EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference: EN61000-4-3: 10 V/m (amplitude-modulated, 80 MHz to 1 GHz) (level 3) Immunity Fast Transient Noise: EN61000-4-4: 2 kV (power line) (level 3) Immunity Burst Noise: 1 kV line to line (I/O signal line) Immunity Surge: EN61000-4-5: 1 kV line to line 2 kV line to ground (power line) Immunity Conducted Disturbance EN61000-4-6: 3 V (0.15 to 80 MHz) (level 2) Immunity Voltage Dip/Interrupting EN61000-4-11: 0.5 cycles, 0, 180, 100% (rated voltage) Note: The K3TF-V8@@ and K3TF-V9@@ do not conform to CE marking standards. Characteristics Input signal AC voltage/current A/D conversion method Double integral method Root-mean-square value indication Root-mean-square value of half-wave rectified current detected Sampling period 2.5 times/s Display refresh period 2.5 times/s Max. displayed digits 3 1/2 digits (1999) Display 7-segment red LED Decimal point display position Selected with slide switch (see note 1) Overflow display Overflow: 1@@@ Zero suppression Not supported. External control Process value hold (terminals on rear panel short-circuited) Degree of protection Front panel: IEC IP51 (see note 2) Case: IEC IP20 Terminals: IEC IP00 Note: 1. Only for models with signal monitor. 2. IP51 is maintained when the water-resistive soft cover and bracket are used. IP50 will be, however, maintained without these water-resistive accessories. 3 K3TF Measuring Ranges Monitor Input range Line monitor AC voltage Signal monitor AC voltage Measuring range AC current Max. resolution Input impedance Accuracy 0.3%rdg 1 digit (see note 1) 10 M Max. permissible load 0 to 199.9 V 100 mV 500 V 0 to 400 V 1V 10 M 0.3%rdg 1 digit 500 V 0 to 199.9 mV 100 V 10 M 0.3%rdg 1 digit 250 V 0 to 1.999 V 1 mV 10 M 0.3%rdg 1 digit 250 V 0 to 19.99 V 10 mV 1 M 0.3%rdg 1 digit 250 V 0 to 1.999 mA 1 A 100 0.5%rdg 1 digit 50 mA 0 to 19.99 mA 10 A 10 0.5%rdg 1 digit 150 mA 0 to 199.9 mA 100 A 1 0.5%rdg 1 digit 500 mA 0 to 1.999 A 1 mA 0.1 0.5%rdg 1 digit 3A Note: 1. With 100% input. 0.3% FS1 digit when the input is less than 35% FS. 2. The above accuracy is at an input frequency range of 40 Hz to 1 kHz and an ambient temperature of 235C. 3. A large error will result if a signal that is not a sine wave is used (e.g., a signal from thyristor control). Connections External Connections 1 2 AC signal input 3 4 GND HOLD 5 6 Unused 7 8 9 AC power supply Note: Terminals 2 and 3 of the models are not internally insulated. Connect a relay with high contact reliability and insulation (with a minimum load current of 0.3 mA) or a photocoupler with high insulation (with a residual voltage of 1 V max. and a current leakage of 0.1 mA max.) to these terminals for external control. Nomenclature Display Unit name 103 102 101 No decimal point Select the decimal position with the slide switch under the cover on the front panel (signal monitor only). Remove the front panel by using a flat-blade screwdriver or your fingernail in the two notches at the bottom. Note: The decimal position cannot be changed for the K3TF-V81@ or K3TF-V91@. 4 K3TF Dimensions Note: All units are in millimeters unless otherwise indicated. Panel Cutouts 92+0.8 -0 98 92 45+0.6 -0 75 min. 120 min. Note: The values above are recommended values. Do not group-mount the meters at intervals less than the recommended ones. 48 43 LED Indicator Size 14.2 mm 96 3.5 66 The K3TF uses M3.5 terminals. 7.8 mm Application Examples High AC Voltage Measurement Large AC Current Measurement When voltage exceeding the maximum voltage in the standard range is measured (for example: more than 400 V), a divider or potential transformer (PT) is connected externally. When AC current exceeding 2 A is measured, a current transformer (CT) is connected externally. Hi Hi Hi Digital panel meter Input Lo Lo PT Hi Digital panel meter Input Lo Lo CT 5 K3TF Safety Precautions Refer to Safety Precautions for All Digital Panel Meters. Precautions for Safe Use Calibration The front panel cover is removed when setting the decimal point position or performing calibration. Do not, however, touch any parts other than the slide switches or adjustment knob or come close to any metal parts. Calibrate the Digital Panel Meter regularly so that the Digital Panel Meter can maintain processing accuracy. Use a standard signal generator with an accuracy of 99.99% min. for calibration. For the precise calibration methods, refer to the Instruction Sheet for the Digital Panel Meter. After the front panel cover is removed to calibrate the K3TF or set the decimal position, do not touch components other than the slide switch and calibration adjustor. Keep metal objects off the K3TF after the cover is removed, especially when power is turned on. Precautions for Correct Use Accessories (Order Separately) Mounting Water-resistive Soft Front Cover Recommended panel thickness is 1 to 3.2 mm. Mount the Digital Panel Meter by attaching the mounting bracket supplied as an accessory from the rear of the Digital Panel Meter, hook the mounting bracket to the Digital Panel Meter securely, and tighten the mounting screws by turning them clockwise with a tightening torque of 5 kgf*cm (0.49 N*m). For dismounting, loosen the screws and widen the hooks. Before mounting the Digital Panel Meter to a panel, attach the waterresistive soft front cover and mounting bracket to the Digital Panel Meter properly so that the Digital Panel Meter will maintain IP51 water-resistive standards. Before you calibrate Digital Panel Meters, remove the water-resistive soft front cover. Refer to the operation manual included with the Digital Panel Meter for the calibration procedure. Always attach the Mounting Bracket before wiring the terminals. Also, always remove the wiring before removing the Mounting Bracket. Mounting Bracket Mount the Digital Panel Meter as horizontally as possible. Never use the Digital Panel Meter in locations where corrosive gas (particularly sulfide or ammonia gas) is generated. As much as possible avoid use of the Digital Panel Meter in a location subject to severe shock or vibration, excessive dust, or excessive moisture. Select a mounting location where the Digital Panel Meter can be used at an ambient operating temperature -10 to 55C. Soft Cover Note: Be sure to use the Water-resistive Soft Front Cover and mounting bracket together. No product is shipped with the unit label attached. Select a unit label from the sheet provided, and attach it to the Digital Panel Meter. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 6 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2014.2 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2014 All Right Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: K32 -L49TC K3TF-A914 K32-L49TC K3TF-V914 K3TF-V814 K3TF-V514